首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Disposable amperometric magnetosensors, involving a mixture of modified-magnetic beads (MBs), for the multiplex screening of cephalosporins (CPHs), sulfonamides (SAs) and tetracyclines (TCs) antibiotic residues in milk are reported for the first time in this work. The multiplexed detection relies on the use of a mixture of target specific modified magnetic beads (MBs) and application of direct competitive assays using horseradish peroxidase (HRP)-labeled tracers. The amperometric responses measured at −0.20 V vs. the Ag pseudo-reference electrode of screen-printed carbon electrodes (SPCE) upon the addition of H2O2 in the presence of hydroquinone (HQ) as redox mediator, were used to monitor the extent of the different affinity reactions. The developed methodology, involving a simple and short pretreatment, allowed discrimination between no contaminated UHT and raw milk samples and samples containing antibiotic residues at the maximum residue limits (MRLs). The usefulness of the multiplexed magnetosensor was demonstrated by analyzing spiked milk samples in only 5 min. The results demonstrated that a clear discrimination of milk samples contaminated with antibiotics at their MRL level or their mixtures, allowing the identification of milk not complying with current legislation. These features make the developed methodology a promising alternative in the development of user-friendly devices for on-site analysis to ensure quality control for dairy products.  相似文献   

2.
The determination of tetracycline by fluorescence spectrophotometry in complex matrices has some difficulties, because the presence of other compounds in the matrix affects the analytical signal. In this work, the effect of some inorganic species that are present in whey milk on the fluorescence signal of tetracycline is studied using a D-optimal experimental design. Next, an experimental strategy is proposed in conjunction with Parallel Factor Analysis, PARAFAC, modeling that leads to suitably modeling the severe matrix effect in the determination of tetracycline in whey milk. A specific design is performed in such a way that the lack of trilinearity due to the effect of the presence of interferents on the signal is obviated. Then, ten test samples from three brands of milk, spiked with different quantities of tetracycline and measured in 2 days were analysed using this methodology (mean of the absolute value of the relative errors: 5.1%). The developed analytical method fulfils the property of trueness, the relative errors being, both in calibration and prediction, inside the interval set by Commission Decision 2002/657/EC at these concentration levels. Decision limits (CCα) at x0 = 0 μg L−1 and at x0 = 100 μg L−1 were 13.2 and 112.4 μg L−1 respectively, for α = 0.05; whereas detection capabilities (CCβ) were 25.9 μg L−1 and 124.4 μg L−1 respectively for α = β = 0.05.  相似文献   

3.
A high-performance liquid chromatography-fluorescence detection method was optimized and validated to determine tetracyclines residues in bovine milk. Post-column derivatization using metal complexation in non-aqueous reagent increased the fluorescence of chelates by a factor up to 2.54 compared to water (signal-to-noise ratio enhancement). Overall recoveries ranged from 61 to 115%, with RSDr from 5 to 15% (n = 54). Detection limits ranged from 5 to 35 μg kg−1. Limits of quantification were established at 50 μg kg−1. Decision limits (CCα) were 109, 108 and 124 μg kg−1 and detection capabilities (CCβ) 119, 117 and 161 μg kg−1 for oxytetracycline, tetracycline and chlortetracycline, respectively. The method was applied successfully in a national monitoring program.  相似文献   

4.
Tetracycline (TC) antibiotics are widely used for prevention and control of disease because they inhibit the growth of bacteria. However, the presence of TC antibiotics residues in food causes harmful effects on consumer's health such as allergic reactions, liver damage and gastrointestinal disturbance, so that many countries have set MRLs (maximum residue levels). Therefore, it is necessary to detect tetracycline residues, to develop suitable analytical techniques to be used as routine screens and field detection.A new approach to the biotin-avidin mediated competitive ELISA is developed to determine tetracycline residues in milk. After optimization, the LOD and LOQ were 1.0 × 10− 10 M (0.048 μg/L) and 1.0 × 10− 9 M, respectively, and the working range from 3.16 × 10− 10 M to 3.16 × 10− 7 M toward TC in milk. No cross-reactivity was observed with the structurally similar compounds; chlortetracycline (13.7%), oxytetracycline (10%) and doxytetracycline (< 1%). Additionally percent recoveries of TC spiked in milk were quite satisfactory (∼ 90%). Comparing our results obtained in this work with others, it shows with the capability to detect TC ranging in MRLs (100 μg/L in milk) sufficiently with highly sensitivity in milk, and with simple pre-treatment. In addition, this method can apply to developing useful ELISA test kit for determination of TCs in milk.  相似文献   

5.
A one-step immunochromatographic assay (ICA) was developed for the detection of seven kinds of cephems in milk. Polyclonal antibodies (PcAb) with group-specific to cephems were raised in rabbits after immunization with cephalexin-keyhole limpet hemocyanin (KLH) conjugate. The specificity of anti-sera was determined by indirect competitive enzyme-linked immunosorbent assay (icELISA), and the 50% inhibitions (IC50) of cephalexin and cefadroxil were obtained at 1.5 ng mL−1; IC50 of cefatiofur, cefapirin, cefazolin, cefalothin and cefotaxine were 4, 3.7, 3.2, 4.5 and 5 ng mL−1, respectively. The PcAb against cephems were conjugated to colloidal gold particles as the detection reagent for ICA strips to test for cephems. This method achieved semi-quantitative detection of cephems in <5 min, with high sensitivity to cephalexin and cefadroxil (both 0.5 ng mL−1). At the same time, cefatiofur, cefapirin, cefazolin, cefalothin and cefotaxine were detected at <100 ng mL−1 in spiked processed-milk samples. This method was compared with an enzyme-linked immunosorbent assay by testing 40 milk samples, and the positive samples were validated by a high-performance liquid chromatographic method, with an agreement rate of 100% for both comparisons. In conclusion, the method was rapid and accurate for the multi-residue detection of cephems in milk.  相似文献   

6.
A novel, simple, sensitive and precise spectrofluorimetric method was developed for measuring the melamine concentration in different milk batch samples. The method was based upon measuring the quenching of the luminescence intensity of the produced yellow colored ruthenium(II) carbonyl complex of the general formula [Ru(CO)2(L)] (where L = anion of tetradentate Schiff base). The Ru(II) complex exhibited characteristic luminescence band in the visible region. The remarkable quenching of the luminescence intensity of [Ru(CO)2(L)] complex by various concentrations of melamine was successfully used as a chemosensor for the assessment of melamine in different milk samples at λex = 400 nm and pH 7.4 in DMSO with a linear dynamic range 1.0 × 10−6 to 3.0 × 10−9 mol L−1 and lower detection limit (LOD) and quantification detection limit (QOD) of 3.3 × 10−10 and 1.0 × 10−9 mol L−1, respectively.  相似文献   

7.
A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.  相似文献   

8.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) with photometric detection of horseradish peroxidase (HRP) activity, was developed in plate to detect oxytetracycline (OTC) in Gilthead sea bream (Sparus aurata) samples. The results were compared to those obtained by time-resolved fluoroimmunoassay (TR-FIA) using a secondary antibody with coproporphyrin of platinum (II) (PtCP) as marker. The limits of detection obtained in fish extract were 16 and 0.08 μg kg−1 for photometric and fluorometric detections, respectively; therefore, they were suitable for fish quality control according to the maximum residue level established by the European Union.An extraction procedure using methanol:water 70:30 (v/v) + 1 mL EDTA 0.1 M, and different clean-up procedures based on solid-phase extraction (C18, polymeric reversed phase, SCX, Si) was assayed. The matrix effects were overcome by means of an average tetracycline-free fish extract calibration curve used for quantification.The OTC optimized ELISA can also be applied to determine tetracycline and chlortetracycline residues with good results. Thus, the developed immunoassay could be considered as a generic assay for the most used tetracyclines in aquaculture antibiotic treatments.In order to confirm the utility of the developed immunoassay as a semi-quantitative methodology, fish samples obtained from different supermarkets were analyzed. Results correlate well with those obtained with a reference HPLC method.  相似文献   

9.
A surface plasmon resonance (SPR) biosensor screening assay was developed and validated to detect 11 benzimidazole carbamate (BZT) veterinary drug residues in milk. The polyclonal antibody used was raised in sheep against a methyl 5(6)-[(carboxypentyl)-thio]-2-benzimidazole carbamate protein conjugate. A sample preparation procedure was developed using a modified QuEChERS method. BZT residues were extracted from milk using liquid extraction/partition with a dispersive solid phase extraction clean-up step. The assay was validated in accordance with the performance criteria described in 2002/657/EC. The limit of detection of the assay was calculated from the analysis of 20 known negative milk samples to be 2.7 μg kg−1. The detection capability (CCβ) of the assay was determined to be 5 μg kg−1 for 11 benzimidazole residues and the mean recovery of analytes was in the range 81-116%. A comparison was made between the SPR-biosensor and UPLC-MS/MS analyses of milk samples (n = 26) taken from cows treated different benzimidazole products, demonstrating the SPR-biosensor assay to be fit for purpose.  相似文献   

10.
Sérgio M. Santos 《Talanta》2007,71(2):731-737
An easy to use and low time consuming capillary electrophoresis (CE) method was developed and applied to the simultaneous determination of six antibiotics (ampicillin, amoxicillin, cloxacillin, penicillin, tetracycline and chloramphenicol) in spiked milk samples. Samples of milk were cleaned up by solid-phase extraction (with a C18 cartridge) after protein precipitation. Analysis was performed by CE and results compared with the obtained via HPLC, both coupled to a UV-vis detector (210 nm). CE employed a 58.5 cm long fused-silica capillary (50 cm to detector), 75 μm i.d., a 2.7 × 10−2 M KH2PO4, 4.3 × 10−2 M Na2B4O7 separation buffer, pH 8; an applied voltage of 18 kV; a hydrostatic injection of 0.5 psi during 3 s; and a run temperature of 25 °C. Under the described conditions, amoxicillin was not separated by HPLC, while CE was able to separate, and, therefore, allow detection. Regardless of amoxicillin, comparable results were obtained by HPLC and CE. The average recoveries of antibiotics, from milk fortified at 2.5 and 5 μg/mL, was over 72% with R.S.D.s within 5%. Recovery levels were essentially dictated by the used SPE cartridge.  相似文献   

11.
Three-layer structure graphene/mesoporous silica composites incorporated with C8-modified interior pore-walls (graphene@mSiO2-C8) were prepared and applied for efficient extraction of glucocorticoid residuals in milk followed by liquid chromatography-tandem mass spectrometry (LC–MS/MS) analysis. The graphene@mSiO2-C8 nanocomposites were synthesized by coating C8-modified mesoporous silica onto hydrophilic graphene nanosheets through a simple surfactant-mediated co-condensation sol–gel process. The obtained nanosheets possess unique properties of large surface area (632 m2/g), extended plate-like morphology in the exterior surface, highly open pore structure with uniform pore size (2.8 nm), numerous C8-modified interior pore-walls, as well as good water dispersibility. The performance of the prepared graphene@mSiO2-C8 materials for extracting small hydrophobic molecules directly from complex protein-rich samples was evaluated by analysis of glucocorticoids in milk. Extraction conditions such as sorbents amount, type and volume of eluting solvent, time of adsorption and desorption were investigated and optimized to achieve the best efficiency. Method validations including linearity, recovery, repeatability, and limit of detection (LOD) were also studied. The results indicated that this methodology provided low LOD (S/N = 3, 0.0075–0.03 ng mL−1) and good linearity (0.03–60 ng mL−1, R2 > 0.996) for glucocorticoids. Satisfactory reusability and stability were also obtained during the extraction. Finally, the graphene@mSiO2-C8 composites were successfully applied to the extraction and residue analysis of glucocorticoids in real milk samples. The experimental results showed that this novel approach offered an attractive choice for convenient, efficient and rapid solid-phase extraction of targeted hydrophobic compounds in biological samples.  相似文献   

12.
The development of an electrochemical immunosensor incorporated in a micro fluidic cell for quantification of citrinin (CIT) mycotoxin in rice samples is described for the first time. Both CIT present in rice samples and immobilized on a gold surface electrodeposited on a glassy carbon (GC) electrode modified with a cysteamine self-assembled monolayer were allowed to compete for the monoclonal mouse anti-CIT IgG antibody (mAb-CIT) present in solution. Then, an excess of rabbit anti mouse IgG (H + L) labelled with the horseradish peroxidase (secAb-HRP) was added, which reacts with the mAb-CIT which is in the immuno-complex formed with the immobilized CIT on the electrode surface. The HPR, in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of catechol (H2Q) whose back electrochemical reduction was detected on a GC electrode at −0.15 V vs Ag/AgCl by amperometric measurements. The current measured is proportional to the enzymatic activity and inversely proportional to the amount of CIT present in the rice samples. This immunosensor for CIT showed a range of work between 0.5 and 50 ng mL−1. The detection (LOD) and the quantification (LOQ) limits were 0.1 and 0.5 ng mL−1, respectively. The coefficients of variation intra- and inter-assays were less than 6%. The electrochemical detection could be done within 2 min and the assay total time was 45 min. The immunosensor was provided to undertake at least 80 determinations for different samples with a minimum previous pre-treatment. Our electrochemical immunosensor showed a higher sensitivity and reduced analysis time compared to other analytical methods such as chromatographic methods. This methodology is fast, selective and very sensitive. Thus, the immunosensor showed to be a very useful tool to determine CIT in samples of cereals, mainly rice samples.  相似文献   

13.
An amperometric immunoassay for the determination of tumor necrosis factor alpha (TNFα) protein biomarker in human serum based on the use of magnetic microbeads (MBs) and disposable screen-printed carbon electrodes (SPCEs) has been developed. The specifically modified microbeads were magnetically captured on the working electrode surface and the amperometric responses were measured at −0.20 V (vs. Ag pseudo-reference electrode), upon addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate. After a thorough optimization of the assay, extremely low limits of detection were achieved: 2.0 pg mL−1 (36 fM) and 5.8 pg mL−1 (105 fM) for standard solutions and spiked human serum, respectively. The simplicity, robustness and this clinically interesting LOD proved the developed TNFα immunoassay as a good contender for real clinical application.  相似文献   

14.
The development and validation of a multidimensional HPLC method using an on-line clean-up column coupled with amperometric detection employing a boron-doped diamond (BDD) electrode for the simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) in bovine milk are presented. Aliquots of pre-prepared skim-milk samples were directly injected into a RAM octyl-BSA column in order to remove proteins that otherwise would interfere with milk analysis. After exclusion of the milk proteins, SMX and TMP were transferred to the analytical column (an octyl column) and the separation of the compounds from one another and from other endogenous milk components was achieved. SMX and TMP were detected amperometrically at 1.25 V vs. Ag/AgCl (3.0 mol L−1 KCl). Results with good linearity in the concentration ranges 50-800 and 25-400 μg L−1 for SMX and TMP, respectively, were obtained and no fouling of the BDD electrode was observed within the experimental period of several hours. The intra- and inter-assay coefficients of variation were less than 10% for both drugs and the obtained LOD values for SMX and TMP were 25.0 and 15.0 μg L−1, respectively.  相似文献   

15.
《Analytica chimica acta》2004,501(2):193-203
According to the committee decision of 12 August 2002 (2002/657/EC) the capability of detection, CCβ, must be set in all analytical methods not only at concentration levels close to zero but also at the maximum permitted limit (PL). In this work we describe a methodology which evaluates the capability of detection of a fluorescence technique with soft calibration models (bilinear and trilinear PLS) to determine tetracyclines (group B1 substances from annex 1 of Directive 96/23/EC). Its estimation is based on the generalisation of the procedure described in International Union of Pure and Applied Chemistry and in the ISO standard 11843 for univariate signals which evaluates the probabilities of false positive (α) and false negative (β). The capability of detection, CCβ, estimated from the second-order signal and the trilinear PLS model is 9.93 μg l−1 of tetracycline, 17.75 μg l−1 of oxytetracycline and 26.31 μg l−1 of chlortetracycline, setting α and β at 0.05. The capability of detection, CCβ, determined around the PL (100 μg kg−1 in milk and muscle) with the second-order signal is 109.4 μg l−1 of tetracycline, 117.0 μg l−1 of oxytetracycline and 124.9 μg l−1 of chlortetracycline, setting α and β at 0.05. The results were compared with those obtained with zero and first-order signals. The effect of the interferences on the capability of detection was also analysed as well as the number of standards used to build the models and their calibration range.When a tetracycline is quantified in presence of uncalibrated ones by means of the trilinear PLS model the errors oscillate between 14.70% for TC and 9.57% for OTC.  相似文献   

16.
A novel amperometric magnetoimmunosensor using an indirect competitive format is developed for the sensitive detection of the amino-terminal pro-B-type natriuretic peptide (NT-proBNP). The immunosensor design involves the covalent immobilization of the antigen onto carboxylic-modified magnetic beads (HOOC-MBs) activated with N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide (EDC) and N-hydroxysulfosuccinimide (sulfo-NHS), and further incubation in a mixture solution containing variable concentrations of the antigen and a fixed concentration of an HRP-labeled detection antibody. Accordingly, the target NT-proBNP in the sample and that immobilized on the MBs compete for binding to a fixed amount of the specific HRP-labeled secondary antibody. The immunoconjugate-bearing MBs are captured by a magnet placed under the surface of a disposable gold screen-printed electrode (Au/SPE). The amperometric responses measured at –0.10 V (vs. a Ag pseudo-reference electrode), upon addition of 3,3′,5,5′-tetramethylbenzidine (TMB) as electron transfer mediator and H2O2 as the enzyme substrate, are used to monitor the affinity reaction. The developed magnetoimmunosensor provides attractive analytical characteristics in 10-times diluted human serum samples, exhibiting a linear range of clinical usefulness (0.12–42.9 ng mL−1) and a detection limit of 0.02 ng mL−1, which can be used in clinical diagnosis of chronic heart failure in the elderly and for classifying patients at risk of death after heart transplantation. The magnetoimmunosensor was successfully applied to the analysis of spiked human serum samples.  相似文献   

17.
A capillary zone electrophoresis method with UV detection was developed for the simultaneous detection and quantification of three tetracyclines in chicken meat samples: tetracycline (TC), oxytetracycline (OTC) and doxycycline (DOC). The separation conditions were: a running buffer containing 30 mM sodium phosphate, 2 mM EDTA disodium salt and 2.5% 2-propanol, pH 12.0, a 5 s hydrodynamic injection and a 14 kV separation voltage. Two different clean-up methodologies were employed: solid-phase extraction with C18 cartridges and ion exchange with Amberlite XAD7 resin. Analytes were detected at 360 nm in less than 12 min. LODs ranged from 61 μg kg−1 for OTC to 68 μg kg−1 for DOC with C18 cartridges, and 81 μg kg−1 for DOC to 89 μg kg−1 for TC with Amberlite XAD7 resin. The recoveries for TC, OTC and DOC obtained by both methods were between 85 and 95%, and the peak area repeatability for all of the samples was below 5% in all cases. Twenty-four samples of commercial chicken drumsticks were examined with both clean-up methodologies. In nine cases (37.5%) TC was detected, in a range from 197.8 to 2564.3 μg kg−1, and in seven cases (29.2%) OTC was detected in a range from 83.0 to 2049.3 μg kg−1. DOC was not detected in any of the tested samples. This method would be useful for the routine monitoring of TCs residues in poultry muscle.  相似文献   

18.
Zhang J  Zhang Z  Xiang Y  Dai Y  Harrington Pde B 《Talanta》2011,84(5):1401-1409
A sequential injection analysis (SIA) spectrophotometric method for determining tetracycline (TC), chlortetracycline (CTC) and oxytetracycline (OTC) in different sample matrices were described. The method was based on the reaction between tetracyclines and yttrium (III) in weak basic micellar medium, yielding the light yellow complexes, which were monitored at 390, 392 and 395 nm, respectively. A cationic surfactant, cetyltrimethylammonium bromide (CTAB) was used to obtain the micellar system. The linear ranges of calibration graphs were between 1.0 × 10−5 and 4 × 10−4 mol L−1, respectively. The molar absorptivities were 5.24 × 105, 4.98 × 104 and 4.78 × 104 L mol−1 cm−1. The detection limits (3σ) were between 4.9 × 10−6 and 7.8 × 10−6 mol L−1 whereas the limit of quantitations (10σ) were between 1.63 × 10−5 and 2.60 × 10−5 mol L−1 the interday and intraday precisions within a weak revealed as the relative standard deviations (R.S.D., n = 11) were less than 4%. The method was rapid with a sampling rate of over 60 samples h−1 for the three drugs. The proposed method has been satisfactorily applied for the determination of tetracycline and its derivatives in pharmaceutical preparations together with their residues in milk and honey samples collected in Chiang Mai Province. The accuracy was found to be high as the Student's t-values were found to be less than the theoretical ones. The results were compared favorably with those obtained by the conventional spectrophotometric method.  相似文献   

19.
A novel approach was developed for nitrate analysis in a FIA configuration with amperometric detection (E = −0.48 V). Sensitive and reproducible current measurements were achieved by using a copper electrode activated with a controlled potential protocol. The response of the FIA amperometric method was linear over the range from 0.1 to 2.5 mmol L−1 nitrate with a detection limit of 4.2 μmol L−1 (S/N = 3). The repeatability of measurements was determined as 4.7% (n = 9) at the best conditions (flow rate: 3.0 mL min−1, sample volume: 150 μL and nitrate concentration: 0.5 mmol L−1) with a sampling rate of 60 samples h−1. The method was employed for the determination of nitrate in mineral water and soft drink samples and the results were in agreement with those obtained by using a recommended procedure. Studies towards a selective monitoring of nitrite were also performed in samples containing nitrate by carrying out measurements at a less negative potential (−0.20 V).  相似文献   

20.
Shi H  Yang Y  Huang J  Zhao Z  Xu X  Anzai J  Osa T  Chen Q 《Talanta》2006,70(4):852-858
An amperometric choline biosensor was developed by immobilizing choline oxidase (ChOx) in a layer-by-layer (LBL) multilayer film on a platinum (Pt) electrode modified with Prussian blue (PB). 6-O-Ethoxytrimethylammoniochitosan chloride (EACC) was used to prepare the ChOx LBL films. The choline biosensor was used at 0.0 V versus Ag/AgCl to detect choline and exhibited good characteristics such as relative low detection limit (5 × 10−7 M), short response time (within 10 s), high sensitivity (88.6 μA mM−1 cm−2) and a good selectivity. The results were explained based on the ultrathin nature of the LBL films and the low operating potential that could be due to the efficient catalytic reduction of H2O2 by PB. In addition, the effects of pH, temperature and applied potential on the amperometric response of choline biosensor were evaluated. The apparent Michaelis-Menten constant was found to be (0.083 ± 0.001) ×10−3 M. The biosensor showed excellent long-term storage stability, which originates from a strong adsorption of ChOx in the EACC multilayer film. When the present choline biosensor was applied to the analysis of phosphatidylcholine in serum samples, the measurement values agreed satisfactorily with those by a hospital method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号