首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE) and tert-amyl methyl ether (TAME) are oxygenated compounds added to gasoline to enhance octane rating and to improve combustion. They may be found as pollutants of living and working environments. In this work a robotized method for the quantification of low level MTBE, ETBE and TAME in human urine was developed and validated. The analytes were sampled in the headspace of urine by SPME in the presence of MTBE-d12 as internal standard. Different fibers were compared for their linearity and extraction efficiency: carboxen/polydimethylsiloxane, polydimethylsiloxane/divinylbenzene, and polydimethylsiloxane. The first, although highly efficient, was discarded due to deviation of linearity for competitive displacement, and the polydimethylsiloxane/divinylbenzene fiber was chosen instead. The analysis was performed by GC/MS operating in the electron impact mode. The method is very specific, with range of linearity 30-4600 ng L−1, within- and between-run precision, as coefficient of variation, <22 and <16%, accuracy within 20% the theoretical level, and limit of detection of 6 ng L−1 for all the analytes. The influence of the matrix on the quantification of these ethers was evaluated analysing the specimens of seven traffic policemen exposed to autovehicular emissions: using the calibration curve and the method of standard additions comparable levels of MTBE (68-528 ng L−1), ETBE (<6 ng L−1), and TAME (<6 ng L−1) were obtained.  相似文献   

2.
A novel microextraction technique, air-assisted liquid–liquid microextraction (AALLME), which is a new version of dispersive liquid–liquid microextraction (DLLME) method has been developed for extraction and preconcentration of phthalate esters, dimethyl phthalate (DMP), diethyl phthalate (DEP), di-iso-butyl phthalate (DIBP), di-n-butyl phthalate (DNBP), and di-2-ethylhexyl phthalate (DEHP), from aqueous samples prior to gas chromatography–flame ionization detection (GC–FID) analysis. In this method, much less volume of an organic solvent is used as extraction solvent in the absence of a disperser solvent. Fine organic droplets were formed by sucking and injecting of the mixture of aqueous sample solution and extraction solvent with a syringe for several times in a conical test tube. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by GC–FID. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 0.12–1.15 and 0.85–4 ng mL−1, respectively. Enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 889–1022 and 89–102%, respectively. The relative standard deviations (RSDs) for the extraction of 100 ng mL−1 and 500 ng mL−1 of each phthalate ester were less than 4% for intra-day (n = 6) and inter-days (n = 4) precision. Finally some aqueous samples were successfully analyzed using the proposed method and three analytes, DIBP, DNBP and DEHP, were determined in them at ng mL−1 level.  相似文献   

3.
Dispersive liquid–liquid microextraction with solidification of floating organic drop (DLLME-SFO) is one of the most interesting sample preparation techniques developed in recent years. Although several applications have been reported, the potentiality and limitations of this simple and rapid extraction technique have not been made sufficiently explicit. In this work, the extraction efficiency of DLLME-SFO for pollutants from different chemical families was determined. Studied compounds include: 10 polycyclic aromatic hydrocarbons, 5 pesticides (chlorophenoxy herbicides and DDT), 8 phenols and 6 sulfonamides, thus, covering a large range of polarity and hydrophobicity (Log Kow 0–7, overall). After optimization of extraction conditions using 1-dodecanol as extractant, the procedure was applied for extraction of each family from 10-mL spiked water samples, only adjusting sample pH as required. Absolute recoveries for pollutants with Log Kow 3–7 were >70% and recovery values within this group (18 compounds) were independent of structure or hydrophobicity; the precision of recovery was very acceptable (RSD < 12%) and linear behavior was observed in the studied concentration range (r2 > 0.995). Extraction recoveries for pollutants with Log Kow 1.46–2.8 were in the range 13–62%, directly depending on individual Log Kow values; however, good linearity (r2 > 0.993) and precision (RSD < 6.5%) were also demonstrated for these polar solutes, despite recovery level. DLLME-SFO with 1-dodecanol completely failed for extraction of compounds with Log Kow ≤ 1 (sulfa drugs), other more polar extraction solvents (ionic liquids) should be explored for highly hydrophilic pollutants.  相似文献   

4.
The fate and persistence of microcystin cyanotoxins in aquatic ecosystems remains poorly understood in part due to the lack of analytical methods for microcystins in sediments. Existing methods have been limited to the extraction of a few extracellular microcystins of similar chemistry. We developed a single analytical method, consisting of accelerated solvent extraction, hydrophilic–lipophilic balance solid phase extraction, and reversed phase high performance liquid chromatography-tandem mass spectrometry, suitable for the extraction and quantitation of both intracellular and extracellular cyanotoxins in sediments as well as pore waters. Recoveries of nine microcystins, representing the chemical diversity of microcystins, and nodularin (a marine analogue) ranged between 75 and 98% with one, microcystin-RR (MC-RR), at 50%. Chromatographic separation of these analytes was achieved within 7.5 min and the method detection limits were between 1.1 and 2.5 ng g−1 dry weight (dw). The robustness of the method was demonstrated on sediment cores collected from seven Canadian lakes of diverse geography and trophic states. Individual microcystin variants reached a maximum concentration of 829 ng g−1 dw on sediment particles and 132 ng mL−1 in pore waters and could be detected in sediments as deep as 41 cm (>100 years in age). MC-LR, -RR, and -LA were more often detected while MC-YR, -LY, -LF, and -LW were less common. The analytical method enabled us to estimate sediment-pore water distribution coefficients (Kd), MC-RR had the highest affinity for sediment particles (log Kd = 1.3) while MC-LA had the lowest affinity (log Kd = −0.4), partitioning mainly into pore waters. Our findings confirm that sediments serve as a reservoir for microcystins but suggest that some variants may diffuse into overlying water thereby constituting a new route of exposure following the dissipation of toxic blooms. The method is well suited to determine the fate and persistence of different microcystins in aquatic systems.  相似文献   

5.
A new generation polymeric ionic liquid (PIL), poly(1-4-vinylbenzyl)-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide (poly(VBHDIm+ NTf2)), was synthesized and is shown to exhibit impressive selectivity towards the extraction of 12 polycyclic aromatic hydrocarbons (PAHs) from aqueous samples when used as a sorbent coating in direct-immersion solid-phase microextraction (SPME) coupled to gas chromatography (GC). The PIL was imparted with aromatic character to enhance π–π interactions between the analytes and the sorbent coating. For comparison purposes, a PIL with similar structure but lacking the π–π interaction capability, poly(1-vinyl-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide) (poly(HDIm+ NTf2)), as well as a commercial polydimethylsiloxane (PDMS) sorbent coating were evaluated and exhibited much lower extraction efficiencies. Extraction parameters, including stir rate and extraction time, were studied and optimized. The detection limits of poly(VBHDIm+ NTf2), poly(HDIm+ NTf2), and PDMS coatings varied between 0.003–0.07 μg L−1, 0.02–0.6 μg L−1, and 0.1–6 μg L−1, respectively. The partition coefficients (log Kfs) of eight PAHs to the three studied fiber coatings were estimated using a static SPME approach. This study represents the first report of analyte partition coefficients to any PIL-based material.  相似文献   

6.
A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100–200 nm for polyamide nanofibers with a homogeneous and porous surface structure. The extraction efficiency of new coating was investigated for headspace solid-phase microextraction (HS-SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography–mass spectrometry (GC–MS) analysis. Effect of different parameters influencing the extraction efficiency including extraction temperature, extraction time, ionic strength and polyamide amount were investigated and optimized. In order to improve the chromatographic behavior of phenolic compounds, all the analytes were derivatized prior to the extraction process using basic acetic anhydride. The detection limits of the method under optimized conditions were in the range of 2–10 ng L−1. The relative standard deviations (RSD) (n = 3) at the concentration level of 1.7–6.7 ng mL−1 were obtained between 1 and 7.4%. The calibration curves of chlorophenols showed linearity in the range of 27–1330 ng L−1 for phenol and monochlorophenols and 7–1000 ng L−1 for dichloro and trichlorophenols. Also, the proposed method was successfully applied to the extraction of phenol and chlorophenols from real water samples and relative recoveries were between 84 and 98% for all the selected analytes except for 2,4,6 tricholophenol which was between 72 and 74%.  相似文献   

7.
The development and performance evaluation of an analytical method dedicated to the comprehensive determination of the most relevant antioxidants and their metabolites in aqueous environmental samples is presented. This was achieved by a miniaturised solid-phase extraction (SPE) with 10 mg Oasis HLB cartridges, which allow to achieve a concentration factor of 200, reducing organic solvent wastes (1 mL of ethyl acetate suffices for complete elution) and SPE costs and eliminating the need for solvent evaporation that otherwise compromises the recoveries of butylated hydroxytoluene (BHT) and 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q). Analytes were then determined by gas chromatography–mass spectrometry (GC–MS) after derivatisation with N-methyl-N-(tert-butyldimethylsilyl)-trifluoroacetamide (MTBSTFA) in a single run. BHT-d7 and n-propyl-paraben-d4 (PrP-d4) were used as surrogate internal standards. These surrogates allowed obtaining relative recoveries in the 80–110% range for all analytes even with complex wastewater samples and LODs at the 2–44 ng L−1 level taking into account blank issues often associated to antioxidants analysis. The method was applied to sewage and river waters, showing that the seven analytes could be detected in raw wastewater. BHT and BHT-Q were the most concentrated species in that type of sample (in the 275–871 ng L−1 range). On the other hand two metabolites of BHT, 3,5-di-tert-butyl-4-hydroxybenzaldehyde (BHT-CHO) and 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) appeared to be the most ubiquitous species, being found in all samples in the 10–150 ng L−1 concentration range.  相似文献   

8.
The hollow fiber-based stirring extraction bar liquid–liquid microextraction was applied to the extraction of hormones, including 17-α-ethinylestradiol, 17-α-estradiol, estriol, 17-β-estradiol, estrone, 17-α-hydroxyprogesterone, medroxyprogesterone, progesterone and norethisterone acetate, in milk. The present method has the advantages of both hollow fiber-liquid phase microextraction and stirring bar sorptive extraction. The stirring extraction bar was used as both the stirring bar of microextraction, and extractor of the analytes, which can make extraction, clean-up and concentration be carried out in one step. When the extraction was completed, the stirring extraction bar was easy isolated from the extraction system with the magnet. Several experimental parameters, including the type of extraction solvent, the number of hollow stirring extraction bar, extraction time, stirring speed, ionic strength, and desorption conditions were investigated and optimized. The analytes in the extract were derived and determined by gas chromatography mass spectrometry. Under optimal experimental conditions, good linearity was observed in the range of 0.20–20.00 ng mL−1. The limits of detection and quantification were in the range of 0.02–0.06 ng mL−1 and 0.07–0.19 ng mL−1, respectively. The present method was applied to the analysis of milk samples, and the recoveries of analytes were in the range of 93.6–104.6% with the relative standard deviations ranging from 1.6% to 6.2% (n = 5). The results showed that the present method was a rapid and feasible method for the determination of hormones in milk samples.  相似文献   

9.
In this work, an isotope dilution method for the determination, in agricultural and industrial soil samples, of tetrabromobisphenol-A, tetrachlorobisphenol-A and bisphenol-A by gas chromatography–mass spectrometry was developed. The compounds were extracted from soil by sonication assisted extraction in small columns (SAESC) with a low volume of ethyl acetate as extraction solvent. For dirty soil samples, such as industrial soils, a simultaneous clean-up on an acidified Florisil–anhydrous sodium sulfate mixture was carried out to remove interferences. After extraction, solvent was evaporated and analytes were derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and determined by isotope dilution gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC–MS–SIM), using 13C12 labeled compounds as internal standards. Recoveries from spiked samples were between 88% and 108% and the estimated limits of detection (S/N = 3) varied from 30 pg g−1 to 90 pg g−1. The response obtained with this method was linear over the range assayed, 5–300 ng ml−1, with correlation coefficients equal or higher than 0.999. The validated method was used to investigate the levels of these phenolic compounds in soil samples collected from different locations in Spain. Bisphenol-A was detected in all samples at concentrations from 0.7 ng g−1 to 4.6 ng g−1 in agricultural soils and from 1.1 ng g−1 to 44.5 ng g−1 in industrial soils. Tetrabromobisphenol-A was found in various soil samples at levels in the range of 3.4–32.2 ng g−1 in industrial soils and at 0.3 ng g−1 in one agricultural soil, whereas tetrachlorobisphenol-A was not detected.  相似文献   

10.
A method for the determination of nine UV filter compounds [benzophenone-3 (BP-3), isoamyl methoxycinnamate, 4-methylbenzylidene camphor, octocrylene (OC), butyl methoxydibenzoylmethane, ethylhexyl dimethyl p-aminobenzoate (OD-PABA), ethylhexyl methoxycinnamate (EHMC), ethylhexyl salicylate and homosalate] in water samples was developed and evaluated. The procedure includes non-porous membrane-assisted liquid–liquid extraction (MALLE) and LC–atmospheric pressure photoionisation (APPI)–MS/MS. Membrane bags made of different polymeric materials were examined to enable a fast and simple extraction of the target analytes. Among the polymeric materials tested, low- and high-density polyethylene membranes proved to be well suited to adsorb the analytes from water samples. Finally, 2 cm length tailor-made membrane bags were prepared from low-density polyethylene in order to accommodate 100 μL of propanol. The fully optimised protocol provides recoveries from 76% to 101% and limits of detection (LOD) between 0.4 ng L−1 (OD-PABA) and 16 ng L−1 (EHMC). The interday repeatability of the whole protocol was below 18%. The effective separation of matrix molecules was proved by only marginal matrix influence during the APPI-MS analysis since no ion suppression effects were observed. During the extraction step, the influence of the matrix was only significant when non-treated wastewater was analysed. The analysis of lake water indicated the presence of seven UV filter compounds included in this study at concentrations between 40 ng L−1 (BP-3) and 4381 ng L−1 (OC). In non-treated wastewater several UV filters were also detected at concentration levels as high as 5322 ng L−1 (OC).  相似文献   

11.
A simple, sensitive and selective method for the simultaneous determination of five ultraviolet (UV) filters: benzophenone, octyl salicylate, homosalate, 3-(4-methylbenzylidene) camphor, 2-hydroxy-4-methoxybenzophenone in aqueous samples was developed. The analytes were extracted by plunger-in-needle solid-phase microextraction with graphene as sorbent, then silylated on-fiber with N-methyl-N-(trimethylsilyl)trifluoroacetamide, and analyzed by gas chromatography–mass spectrometry. Factors affecting the performance of extraction and derivatization steps were thoroughly evaluated. For the optimization of extraction conditions, six relevant factors (parameters) were investigated, including sample pH, salt concentration, extraction time, extraction temperature, stirring speed and sampling mode. In the first stage, a two-level orthogonal array design OA8 (27) matrix was employed to study the effect of six factors. Based on the results of the first stage, three factors were selected for further optimization with a univariant approach during the second stage. Under the final optimized conditions, the method limits of detection for the five UV filters were determined to be in the range of 0.5 and 6.8 ng L−1 (at a signal/noise ratio of 3) and the precision (% relative standard deviation, n = 5) was 0.8–5.6% at a concentration level of 1 μg L−1. The linearities for different analytes were 10–10,000 or 1–5000 ng L−1. The coefficients of determination for the calibration curves were all greater than 0.994. Finally, the proposed method was successfully applied to the extraction and determination of the UV filters in river water samples.  相似文献   

12.
In this work the development and validation of a new procedure for the simultaneous determination of 9 nitro and polycyclic musk compounds: musk ambrette (MA), musk ketone (MK), musk mosken (MM), celestolide (ADBI), phantolide (AHMI), tonalide (AHTN), traseolide (ATII), cashmeran (DPMI) and galaxolide (HHCB) in environmental water samples (estuarine and wastewater) using microextraction by packed sorbent (MEPS) followed by large volume injection-gas chromatography–mass spectrometry (LVI-GC–MS) was carried out. Apart from the optimization of the different variables affecting MEPS (i.e., nature of the sorbent, nature of the solvent elution, sample load, and elution/injection volume) extraction recovery was also evaluated, not only for water samples but also for environmental water matrices such as estuarine and waste water. The use of two deuterated analogs ([2H3]-AHTN and [2H15]-MX) was successfully evaluated in order to correct matrix effect in complex environmental matrices such as influent samples from wastewater treatment plants. Method detection limits (MDLs) ranged from 5 to 25 ng L−1, 7 to 39 ng L−1 and 8 to 84 ng L−1 for influent, effluent and estuarine samples, respectively. Apparent recoveries were higher than 75% for all target compounds in all the matrices studied (estuarine water and wastewater) and the precision of the method, calculated as relative standard deviation (RSD), was below 13.2% at 200 ng L−1 concentration level and below 14.9% at low level (20 ng L−1 for all the target analytes, except for AHTN which was set at 40 ng L−1 and HHCB at 90 ng L−1, due to the higher MDL values presented by those target compounds). Finally, this MEPS procedure was applied to the determination of the target analytes in water samples, including estuarine and wastewater, from two estuaries, Urdaibai (Spain) and Adour (France) and an established stir-bar sorptive extraction-liquid desorption/large volume injection-gas chromatography–mass spectrometry (SBSE-LD/LVI-GC–MS) method was performed in parallel for comparison. Results were in good agreement for all the analytes determined, except for DPMI.  相似文献   

13.
A multi-class, multi-residue method for the analysis of 13 novel flame retardants, 18 representative pesticides, 14 polychlorinated biphenyl (PCB) congeners, 16 polycyclic aromatic hydrocarbons (PAHs), and 7 polybrominated diphenyl ether (PBDE) congeners in catfish muscle was developed and evaluated using fast low pressure gas chromatography triple quadrupole tandem mass spectrometry (LP-GC/MS–MS). The method was based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction with acetonitrile and dispersive solid-phase extraction (d-SPE) clean-up with zirconium-based sorbent prior to LP-GC/MS–MS analysis. The developed method was evaluated at 4 spiking levels and further validated by analysis of NIST Standard Reference Materials (SRMs) 1974B and 1947. Sample preparation for a batch of 10 homogenized samples took about 1 h/analyst, and LP-GC/MS–MS analysis provided fast separation of multiple analytes within 9 min achieving high throughput. With the use of isotopically labeled internal standards, recoveries of all but one analyte were between 70 and 120% with relative standard deviations less than 20% (n = 5). The measured values for both SRMs agreed with certified/reference values (72–119% accuracy) for the majority of analytes. The detection limits were 0.1–0.5 ng g−1 for PCBs, 0.5–10 ng g−1 for PBDEs, 0.5–5 ng g−1 for select pesticides and PAHs and 1–10 ng g−1 for flame retardants. The developed method was successfully applied for analysis of catfish samples from the market.  相似文献   

14.
Coacervative microextraction ultrasound-assisted back-extraction technique (CME-UABE) is proposed for the first time for extracting and preconcentrating organophosphates pesticides (OPPs) from honey samples prior to gas chromatography–mass spectrometry (GC–MS) analysis. The extraction/preconcentration technique is supported on the micellar organized medium based on non-ionic surfactant. To enable coupling the proposed technique with GC, it was required to back extract the analytes into hexane. Several variables including, surfactant type and concentration, equilibration temperature and time, matrix modifiers, pH and buffers nature were studied and optimized over the relative response of the analytes. The best working conditions were as follows: an aliquot of 10 mL 50 g L−1 honey blend solution was conditioned by adding 100 μL 0.1 mol L−1 hydrochloric acid (pH 2) and finally extracted with 100 μL Triton X-114 100 g L−1 at 85 °C for 5 min using CME technique. Under optimal experimental conditions, the enrichment factor (EF) was 167 and limits of detection (LODs), calculated as three times the signal-to-noise ratio (S/N = 3), ranged between 0.03 and 0.47 ng g−1. The method precision was evaluated over five replicates at 1 ng g−1 with RSDs ≤9.5%. The calibration graphs were linear within the concentration range of 0.3–1000 ng g−1 for chlorpirifos; and 1–1000 ng g−1 for fenitrothion, parathion and methidathion, respectively. The coefficients of correlation were ≥0.9992. Validation of the methodology was performed by standard addition method at two concentration levels (2 and 20 ng g−1). The recoveries were ≥90%, indicating satisfactory robustness of the methodology, which could be successfully applied for determination of OPPs in honey samples of different Argentinean regions. Two of the analyzed samples showed levels of methidathion ranged between 1.2 and 2.3 ng g−1.  相似文献   

15.
A new method for the determination of aflatoxins B1, B2, G1, and G2 (AFB1, AFB2, AFG1, AFG2) in cereal flours based on solid-phase microextraction (SPME) coupled with high performance liquid chromatography with post-column photochemical derivatization and fluorescence detection (SPME–HPLC–PD–FD) has been developed. Aflatoxins were extracted from cereal flour samples by a methanol:phosphate buffer (pH 5.8, I = 0.1) (80:20, v/v) solution, followed by a SPME step. Different SPME and HPLC–PD–FD parameters (fiber polarity, temperature, pH, ionic strength, adsorption and desorption time, mobile phase) have been investigated and optimized. This method, which was assessed for the analysis of different cereal flours, showed interesting results in terms of LOD (from 0.035 to 0.2 ng g−1), LOQ (from 0.1 to 0.63 ng g−1, respectively), within and inter-day repeatability (2.27% and 5.38%, respectively) linear ranges (up to 20 ng g−1 for AFB1 and AFG1 and 6 ng g−1 for AFB2 and AFG2), and total raw extraction efficiency (in the range 55–59% at concentrations in the range 0.3–1 ng g−1 and 49–52% at concentrations in the range 1–10 ng g−1). The results were also compared with the purification step carried out by conventional immunoaffinity columns.  相似文献   

16.
We describe a simple and sensitive porous polypropylene membrane-protected micro-solid-phase extraction (μ-SPE) approach for the sample preparation and determination of carbamate pesticides in soil samples by high-performance liquid chromatography. The μ-SPE device consisted of C18 sorbent held within a porous polypropylene envelope. In order to achieve optimum performance, several extraction parameters were optimized. Under the most favorable conditions, the extraction efficiency of the μ-SPE was very high, with detection limits in the range of 0.01–0.40 ng g−1. This is more than two orders of magnitude lower than the limits obtained by the United States Environmental Protection Agency Methods 8321A and 8318. A linear relationship was obtained for each analyte in the range of 2 and 200 ng g−1. The relative standard deviation for the analysis of aged soil samples spiked at 5 ng g−1 was ≤11%. The reproducibility of separate μ-SPE device used for experiments was satisfactory (relative standard deviations ranged from 4 to 11%), indicating that the method is reliable for routine environmental analysis.  相似文献   

17.
A novel method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD), has been developed for the determination of three phthalate esters (dimethyl phthalate (DMP), diethyl phthalate (DEP), and di-n-butyl phthalate (DnBP)) in water samples. A mixture of extraction solvent (41 μL carbon tetrachloride) and dispersive solvent (0.75 mL acetonitrile) were rapidly injected into 5.0 mL aqueous sample for the formation of cloudy solution, the analytes in the sample were extracted into the fine droplets of CCl4. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 5 to 5000 ng mL−1 for target analytes. The enrichment factors for DMP, DEP and DnBP were 45, 92 and 196, respectively, and the limits of detection were 1.8, 0.88 and 0.64 ng mL−1, respectively. The relative standard deviations (R.S.D.) for the extraction of 10 ng mL−1 of phthalate esters were in the range of 4.3-5.9% (n = 7). Lake water, tap water and bottled mineral water samples were successfully analyzed using the proposed method.  相似文献   

18.
A novel sample preparation method, vial wall sorptive extraction (VWSE), which uses a vial whose internal wall is coated with polydimethylsiloxane (PDMS), was developed. The method was applied to the determination of progesterone in human serum sample. Human serum sample (0.5 mL) spiked with progesterone-13C2 was pipetted into the VWSE device and vortex mixing was performed for 30 min. Then, the serum sample was removed and the vial rinsed with purified water. Fifty microliter of methanol as liquid desorption (LD) solvent was pipetted into the VWSE device and vortex mixing was performed for 10 min. Then, the extract was analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The correlation coefficient (r) of the calibration curve over the concentration range of 0.5–200 ng mL−1 was 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.1 and 0.5 ng mL−1, respectively. The relative recoveries were 97.9% (RSD: 4.4%, n = 6) and 102.8% (RSD: 1.1%, n = 6) for progesterone spiked at 5 and 50 ng mL−1, respectively. This simple, accurate, sensitive, and selective analytical method is applicable to the trace analysis of a minute amount of sample.  相似文献   

19.
Mesoporous TiO2 nanoparticles were synthesized with the hydrothermal method and characterized by powder X-ray diffraction (PXRD) and transmission electron microscope (TEM). Then a superior solid-phase microextraction (SPME) fiber was fabricated by sequentially coating the stainless steel fiber with silicone sealant film and mesoporous TiO2 powder. The developed fiber possessed a homogeneous surface and a long life-span up to 100 times at direct immersing (DI) extraction mode. Under the optimized conditions, the extraction efficiencies of the self-made 17 μm TiO2 fiber for six organochlorine pesticides (OCPs) were higher than those of the two commercial fibers (65 μm PDMS/DVB and 85 μm PA fibers) which were much thicker than the former. As for analytical performance, low detection limits (0.08–0.60 ng L−1) and wide linearity (5–5000 ng L−1) were achieved under the optimal conditions. The repeatabilities (n = 5) for single fiber were between 2.8 and 12.3%, while the reproducibilities (n = 3) of fiber-to-fiber were in the range of 3.7–15.7%. The proposed fiber was successfully applied to the sensitive analysis of OCPs in real water samples and four of the six analytes were detected from the rainwater and the lake water samples.  相似文献   

20.
In this study, a convenient and extensible automated ionic liquid-based in situ dispersive liquid–liquid microextraction (automated IL-based in situ DLLME) was developed. 1-Octyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]imide ([C8MIM]NTf2) is formed through the reaction between [C8MIM]Cl and lithium bis[(trifluoromethane)sulfonyl]imide (LiNTf2) to extract the analytes. Using a fully automatic SPE workstation, special SPE columns packed with nonwoven polypropylene (NWPP) fiber, and a modified operation program, the procedures of the IL-based in situ DLLME, including the collection of a water sample, injection of an ion exchange solvent, phase separation of the emulsified solution, elution of the retained extraction phase, and collection of the eluent into vials, can be performed automatically. The developed approach, coupled with high-performance liquid chromatography–diode array detection (HPLC–DAD), was successfully applied to the detection and concentration determination of benzoylurea (BU) insecticides in water samples. Parameters affecting the extraction performance were investigated and optimized. Under the optimized conditions, the proposed method achieved extraction recoveries of 80% to 89% for water samples. The limits of detection (LODs) of the method were in the range of 0.16–0.45 ng mL−1. The intra-column and inter-column relative standard deviations (RSDs) were <8.6%. Good linearity (r > 0.9986) was obtained over the calibration range from 2 to 500 ng mL−1. The proposed method opens a new avenue for automated DLLME that not only greatly expands the range of viable extractants, especially functional ILs but also enhances its application for various detection methods. Furthermore, multiple samples can be processed simultaneously, which accelerates the sample preparation and allows the examination of a large number of samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号