首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report on the utilization of gold nanorods to create a highly responsive glucose biosensor. The feasibility of an amperometric glucose biosensor based on immobilization of glucose oxidase (GOx) in gold nanorod is investigated. GOx is simply mixed with gold nanorods and cross-linked with a cellulose acetate (CA) medium by glutaraldehyde. The adsorption of GOx on the gold nanorods is confirmed by X-ray photoelectron spectroscopy (XPS) measurements. Circular dichroism (CD) and UV-spectrum results show that the activity of GOx was preserved after conjugating with gold nanorods. The current response of modified electrode is 10 times higher than that of without gold nanorods. Under optimal conditions, the biosensor shows high sensitivity (8.4 μA cm−2 mM−1), low detection limit (2 × 10−5 M), good storage stability and high affinity to glucose (). A linear calibration plot is obtained in the wide concentration range from 3 × 10−5 to 2.2 × 10−3 M.  相似文献   

2.
The bionanocomposite film consisting of glucose oxidase/Pt/functional graphene sheets/chitosan (GOD/Pt/FGS/chitosan) for glucose sensing is described. With the electrocatalytic synergy of FGS and Pt nanoparticles to hydrogen peroxide, a sensitive biosensor with a detection limit of 0.6 μM glucose was achieved. The biosensor also has good reproducibility, long-term stability and negligible interfering signals from ascorbic acid and uric acid comparing with the response to glucose. The large surface area and good electrical conductivity of graphene suggests that graphene is a potential candidate as a sensor material. The hybrid nanocomposite glucose sensor provides new opportunity for clinical diagnosis and point-of-care applications.  相似文献   

3.
Li C  Liu Y  Li L  Du Z  Xu S  Zhang M  Yin X  Wang T 《Talanta》2008,77(1):455-459
NiO hollow nanospheres were synthesized by controlled precipitation of metal ions with urea using carbon microspheres as templates, which were for the first time adopted to construct a novel amperometric glucose biosensor. Glucose oxidase was immobilized on the surface of hollow nanospheres through chitosan-assisted cross-linking technique. Due to the high specific active sites and high electrocatalytic activity of NiO hollow nanospheres, the constructed glucose biosensors exhibited a high sensitivity of 3.43 μA/mM. The low detection limit was estimated to be 47 μM (S/N = 3), and the Michaelis-Menten constant was found to be 7.76 mM, indicating the high affinity of enzyme on NiO hollow nanospheres to glucose. These results show that the NiO hollow nanospheres are a promising material to construct enzyme biosensors.  相似文献   

4.
Colloid Au (Au(nano)) with a diameter of about 10 nm was prepared and used in combination with dihexadecylphosphate (DHP) to immobilize glucose oxidase (GOD) onto the surface of a graphite electrode (GE). The direct electrochemistry of GOD confined in the composite film was investigated. The immobilized GOD displayed a pair of redox peaks with a formal potential of -0.475 mV in pH 7.0 O(2)-free phosphate buffers at scan rate of 150 mV s(-1). The GOD in the composite film retained its bioactivity and could catalyze the reduction of dissolved oxygen. Upon the addition of glucose, the reduction peak current of dissolved oxygen decreased, which could be developed for glucose determination. A calibration linear range of glucose was 0.5-9.3 mM with a detection limit of 0.1 mM and a sensitivity of 1.14 microA mM(-1). The glucose biosensor showed good reproducibility and stability. The general interferences that coexisted in human serum sample such as ascorbic acid and uric acid did not affect glucose determination.  相似文献   

5.
A novel amperometric biosensor utilizing two enzymes, glucose oxidase (GOD) and horseradish peroxidase (HRP), was developed for the cathodic detection of glucose. The glucose biosensor was constructed by electrochemical formation of a polypyrrole (PPy) membrane in the presence of GOD on the surface of a HRP-modified sol-gel derived-mediated ceramic carbon electrode. Ferrocenecarboxylic acid (FCA) was used as mediator to transfer electron between enzyme and electrode. In the hetero-bilayer configuration of electrode, all enzymes were well immobilized in electrode matrices and showed favorable enzymatic activities. The amperometric detection of glucose was carried out at +0.16 V (versus saturated calomel reference electrode (SCE)) in 0.1 M phosphate buffer solution (pH 6.9) with a linear response range between 8.0×10−5 and 1.3×10−3 M glucose. The biosensor showed a good suppression of interference in the amperometric detection.  相似文献   

6.
Thin films and the corresponding xerogels were prepared from nickel acetate precursor using the sol–gel dip-coating technique. The differences in thermal stability of the two forms of samples were studied by dynamic and isothermal thermogravimetry. For thin films, the onset decomposition temperature of acetate groups was 230 °C and for the xerogel 250 °C. During thermal decomposition, the formation of nanosized nickel oxide took place. Carbonate ions, which were formed during thermal decompostion of acetate groups, remained either free or bidentately coordinated to nickel. In situ monochromatic optical transmittance changes showed that an optical stability up to the 100th cycle was already achieved for films heated for 15 min at the isothermal temperature (thermal decompositon 25%). Comparison of the results obtained for nickel sulfate (Part I) and nickel acetate precursors shows that at least two parameters, the precursor used and the degree of thermal treatment, have considerable influence on the thermal stability of the thin film and also on its electrochromic response during the cycling process.  相似文献   

7.
通过交联法和自组装法制备了一种双酶型葡萄糖生物传感器.首先以牛血清白蛋白-戊二醛为交联剂以实现对辣根过氧化物酶(HRP)的固载,再利用凝集素-糖蛋白的识别作用将葡萄糖氧化酶(GOD)分子组装到电极表面,制得双酶型的葡萄糖生物传感器.采用原子力显微镜(AFM)考察了复合膜的性质,同时采用循环伏安法和计时电流法考察了该传感...  相似文献   

8.
Cu thin films were deposited on Si(111), glass, and quartz substrates by magnetron sputtering. X‐ray diffraction, SEM, and photoemission electron microscope studies were carried out to characterize the films. An influence of the nature of substrate on the Cu2O and CuO phases formed was observed. Copper silicide formation in case of silicon substrates aided in formation of Cu2O rather than CuO unlike glass and quartz substrates. Formation of nanocrystallites was observed by SEM and X‐ray diffraction. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
In this paper, a three dimensional ordered macroporous self-doped polyaniline/Prussian blue (3DOM SPAN/PB) bicomponent film was fabricated via the inverted crystal template technique using step-by-step electrodeposition. In this bicomponent film, PB not only acted as a redox mediator, but also presented increased stability in neutral or weak alkaline solution by the protection of SPAN layer on the top. A novel glucose biosensor was fabricated based on the large active surface area and excellent conductivity possessed by the 3DOM SPAN/PB film. The applying experimental conditions of the glucose biosensor have been optimized. Under the optimal conditions, the biosensor showed a wide linear range over three orders of magnitude in glucose concentrations (from 2 to 1600 μM) and a low detection limit of 0.4 μM. Moreover, the biosensor exhibited short response time, high selectivity and excellent operation stability, which can be applied to detect the blood sugar in real samples without any pretreatment.  相似文献   

10.
A new amperometric biosensor for hydrogen peroxide was developed based on adsorption of horseradish peroxidase at the glassy carbon electrode modified with zinc oxide nanoflowers produced by electrodeposition onto multi-walled carbon nanotubes (MWNTs) film. The morphology of the MWNTs/nano-ZnO electrode has been investigated by scanning electron microscopy (SEM), and the electrochemical performance of the electrode has also been studied by amperometric method. The resulting electrode offered an excellent detection for hydrogen peroxide at -0.11 V with a linear response range of 9.9×10^-7 to 2.9×10^-3 mol/L with a correlation coefficient of 0.991, and response time 〈5 s. The biosensor displays rapid response and expanded linear response range, and excellent stability.  相似文献   

11.
《Mendeleev Communications》2022,32(4):520-522
Investigations of nanocomposite thin films based on polyarylene- phthalide, single-walled carbon nanotubes and graphene oxide have been carried out. Using these films as a transport layer, field-effect transistors were assembled and their output and transfer characteristics were measured. The mobility of charge carriers was estimated and the obtained values are as follows: μPAP/GO = 0.020 cm2 V?1 s?1 and μPAP/SWCNT = 0.071 cm2 V?1 s?1.  相似文献   

12.
Dai Z  Fang M  Bao J  Wang H  Lu T 《Analytica chimica acta》2007,591(2):195-199
We have constructed a glucose biosensor by immobilizing glucose oxidase (GOD) on titanium-containing MCM-41 (Ti-MCM-41) modified screen-printed electrodes. The strategy of the sensing method is to monitor the extent of the decrease of the reduction current of O2 upon adding glucose at a selected potential. The detection can be done at the applied potential of −0.50 V and can efficiently exclude the interference from commonly coexisted substances. The constructed sensor has a high sensitivity to glucose (5.4 mAM−1 cm−2) and a linear response range of 0.10-10.0 mM. The detection limit is 0.04 mM at a signal-to-noise ratio of 3. The sensor also shows high stability and remains its catalytic activity up to 60 °C. The biocompatibility of Ti-MCM-41 means that this immobilization matrix not only can be used for immobilizing GOD but also can be extended to other enzymes and bioactive molecules, thus providing a promising platform for the development of biosensors.  相似文献   

13.
Thin film polymer multilayers were prepared by spin coating alternating layers of polystyrene and polyvinylpyrrolidone. Samples with 10, 20, 30, 40, and 50 layers were prepared with individual layer thickness values in the range 223–508 nm. These samples were measured using a Fourier transform infrared spectrometer and were found to display narrow photonic band gaps (~ 0.04 to 0.06 μm wide) in their spectral response over the wavelength range 1.6 ? 2.6 μm. The position of the photonic band gaps was controlled by varying the thickness of the individual layers within the multilayer structures. This was achieved by varying the spin speed used during the deposition of the polymer layers. The peak reflectance of the multilayers was controlled by varying the number of layers within the multilayer samples giving values in the range 20–80% (corresponding to transmittances of 80–20%). Calculated transmittance spectra were also obtained using an optical transfer matrix method. These calculated spectra were shown to be in good agreement with the experimental data obtained. These experiments demonstrate a facile approach to the production of low cost dielectric mirrors that have tailored photonic properties over a range of wavelengths that are currently important for applications in fibre optic based telecommunications. © 2011 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys, 2011  相似文献   

14.
Well-crystallized flower-shaped copper oxide nanostructures composed of thin nanosheets has been synthesized by simple low-temperature hydrothermal process and used to fabricate highly sensitive amperometric glucose biosensor which exhibited a high and reproducible sensitivity of 47.19 μA mM?1 cm?2, response time less than 5 s, linear dynamic range from 0.01 to 10.0 mM, correlation coefficient of R = 0.9986, and limit of detection (LOD), based on S/N ratio (S/N = 3) of 1.37 μM. This work opens a way to utilize simply-grown CuO nanostructures as an efficient electron mediator to fabricate efficient glucose biosensors.  相似文献   

15.
The use of biotinylated alginate as an immobilization matrix of enzymes on the surface of the amperometric transducer is described herein. The model used is that of the well-established glucose detection. Several types of immobilization protocols were tested. In the exception of one protocol, biotin labeled glucose oxidase was shown to first require conjugation with avidin, before its immobilization onto a biotin-alginate gel matrix. The response of the biosensors to incremental additions of glucose, was measured by potentiostating the modified electrodes at 0.6 V/SCE. The permeability of the modified electrodes was thereafter measured by using rotating disk electrode (RDE) voltammetry with ferrocenemonocarboxylic acid as the electroactive probe.  相似文献   

16.
A mediator-free glucose biosensor, termed a “third-generation biosensor,” was fabricated by immobilizing glucose oxidase (GOD) directly onto an oxidized boron-doped diamond (BDD) electrode. The surface of the oxidized BDD electrode possesses carboxyl groups (as shown by Raman spectra) which covalently cross-link with GOD through glutaraldehyde. Glucose was determined in the absence of a mediator used to transfer electrons between the electrode and enzyme. O2 has no effect on the electron transfer. The effects of experimental variables (applied potential, pH and cross-link time) were investigated in order to optimize the analytical performance of the amperometric detection method. The resulting biosensor exhibited fast amperometric response (less than 5 s) to glucose. The biosensor provided a linear response to glucose over the range 6.67×10−5 to 2×10−3 mol/L, with a detection limit of 2.31×10−5 mol/L. The lifetime, reproducibility and measurement repeatability were evaluated and satisfactory results were obtained.  相似文献   

17.
In this study, we present a novel approach to prepare of a colorimetric chemical sensor for H2O2 and a glucose biosensor basing on the use of peroxidase-like activity of silver nanoparticles decorated on reduced graphene oxide sheets (AgNPs@rGO) nanocomposite. Herein, AgNPs@rGO nanocomposite was synthesized by a one-step hydrothermal reducing method and its physico-chemical properties were characterized by X-ray diffraction (XRD), Transmission Electron Microscopy (TEM), Ultraviolet–visible spectroscopy (UV–Vis), Fourier-Transform Infrared spectroscopy (FT-IR) and Energy Dispersive X-ray spectroscopy (EDX). Obtained evaluation results shown that the synthesized AgNPs/rGO nanocomposite has performed an efficient peroxidase-like activity for the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMBred) by H2O2, leading to the oxidized form (TMBox) which presents a typical blue color (maximum of absorbance at λmax = 655 nm). A colorimetric assay for H2O2 detection was designed and fabricated with a limit of detection of 20 μM. Moreover, we have used of AgNPs/rGO nanocomposite combining with glucose oxidase (GOx) to develop of a colorimetric glucose biosensor with a low limit of detection of 40 μM and a linear dynamic range from 125 μM to 1 mM. This glucose test was applied to the detection of glucose in human serum samples.  相似文献   

18.
We report on a novel glucose biosensor based on the immobilization of glucose oxidase (GOx) on a Prussian blue modified nanoporous gold surface. The amperometric glucose biosensor fabricated in this study exhibits a fast response and the very low detection limit of 2.5 μM glucose. The sensitivity of the biosensor was found to be very high, 177 μA/mM; the apparent Michaelis–Menten constant is calculated to be 2.1 mM. In addition, the biosensor has good reproducibility and remains stable over 60 days. The anti-interference ability of the biosensor was also assessed, showing little interference from possible interferents such as ascorbic acid (AA), acetaminophen (AP) and uric acid (UA).  相似文献   

19.
Calixarenes and their derivatives may be a promising material for enzyme immobilization owing to their particular configuration, unique molecule recognition function and aggregation properties. In this paper, p-tert-butylthiacalix[4]arene tetra-amine (TC4TA) was first used as enzyme immobilization material. This attractive material was exploited for the mild immobilization of glucose oxidase (GOD) to develop glucose amperometric biosensor. GOD was strongly adsorbed on the TC4TA modified electrode to form TC4TA/GOD composite membrane. The adsorption mechanism was driven from the covalent bond between amino-group of TC4TA and carboxyl group of GOD and molecule recognition function of TC4TA. Amperometric detection of glucose was evaluated by holding the modified electrode at 0.60 V (versus SCE) to oxidize the hydrogen peroxide generated by the enzymatic reaction. The sensor (TC4TA/GOD) showed a relative fast response (response time was about 5 s), low detection limit (20 μM, S/N = 3), and high sensitivity (ca. 10.2 mA M−1 cm−2) with a linear range of 0.08–10 mM of glucose, as well as a good operational and storage stability. In addition, optimization of the biosensor construction, the effects of the applied potential as well as common interfering compounds on the amperometric response of the sensor were investigated and discussed herein.  相似文献   

20.
Metal oxide nanoparticles prepared by pulsed laser deposition (PLD) were applied to nonenzymatic glucose detection. NiO nanoparticles with size of 3 nm were deposited on glassy carbon (GC) and silicon substrates at room temperature in an oxygen atmosphere. Transmission electron microscope (TEM) image showed nanoparticles with the size of 3 nm uniformly scattered on the Si(0 0 1) substrate. Unlike co-sputtering nanoparticle and carbon simultaneously, the PLD method can easily control the surface coverage of nanoparticles on the surface of substrate by deposition time. Cyclic voltammetry was performed on the samples deposited on the GC substrates for electrochemical detection of glucose. The differences between peak currents with and without glucose was used to optimize the coverage of nanoparticles on carbon electrode. The results indicated that optimal coverage of nanoparticles on carbon electrode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号