1.
Four different organic solvents: dimethylformamide, 1,4-dioxane, n-propanol and ethanol were evaluated as alternative organic modifiers to acetonitrile for liquid chromatography (LC) separations. The aim was to establish common sets of chromatographic conditions that could be applied for LC hyphenation to inductively coupled plasma mass spectrometry (ICPMS) as well as to electrospray ionization MS (ESIMS). The approach was to evaluate candidate solvents that, compared to acetonitrile, potentially could give improved analytical performance (low solvent vapor loading, maximized analyte sensitivity and minimized carbon depositions on instrumental parts) in ICPMS analysis while retaining chromatographic and ESIMS performances. The study showed that dimethylformamide, 1,4-dioxane, n-propanol and ethanol all can be advantageous chromatographic modifiers for LC–ICPMS analysis, giving superior performance compared to acetonitrile. For the combined use of LC–ICPMS and LC–ESIMS with a common set of chromatographic conditions, n-propanol gave the best overall performance. The 195Pt+ signal in ICPMS was continuously monitored during a 0–60% organic solvent gradient and at 25% of organic modifier, 100% of the signal obtained at the gradient start was preserved for n-propanol compared to only 35% of the signal when using acetonitrile. Platinum detection limits were 5–8 times lower using n-propanol compared with acetonitrile. Signal-to-noise ratio in continuous ESIMS signal measurements was 100, 90 and 110 for a 100 μg/ml solution of leucine–enkephaline using acetonitrile, ethanol and n-propanol, respectively. Chromatographic efficiency in reversed phase separations was preserved for n-propanol compared to acetonitrile for the analysis of the whole protein cytochrome C and the peptide bacitracin on a column with particle and pore sizes of 5 μm and 300 Å, but slightly deteriorated for the separation of the peptides leucine–enkephaline and bacitracin on a 3 μm and 90 Å column as the peak width at half height for both peptides increased by a factor of two. The performance on the smaller dimensioned column could however be improved by running the separations at 40 °C.  相似文献   

2.
The Corona CAD (charged aerosol detection) is a new type of detector introduced for LC applications that has recently become widely applied in pharmaceutical analysis. The Corona CAD measures a physical property of analyte and responds to almost all non-volatile species, independently of their nature and spectral or physicochemical properties. The LC method with charged aerosol detection was developed for the determination of three isomers of atracurium, cisatracurium and also three isomers of mivacurium with their impurities. The limit of quantitation for laudanosine was 1 μg ml−1. The elaborate method for the analysis of those active substances and laudanosine proved to be fast, precise, accurate and sensitive. All other impurities were identified using time-of-flight mass spectrometry with electrospray ionization.  相似文献   

3.
Dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography with fluorescence detector was applied for the determination of alkylphenols and their short-chained ethoxylates in water samples. Development of DLLME procedure included optimisation of some important parameters such as kind and volume of extracting and dispersing solvents. Under optimised conditions 50 μL of trichloroethylene in 1.5 mL of acetone were rapidly injected into 5 mL of a water sample. After centrifuging the organic phase containing the analytes was taken for evaporation with a gentle nitrogen purge and reconstituted to 50 μL of acetonitrile. The aliquot of this solution was analysed with the use of HPLC. For octylphenol (OP) and octylphenol ethoxylates (OPEOs) linearity was satisfactory in the range 8–1000 μg L−1 and for nonylphenol (NP) and nonylphenol ethoxylates (NPEOs) linearity was in the range from 50 to about 3000 μg L−1. Limit of quantitation was 0.1 μg L−1 for OP and OPEOs and 0.3 μg L−1 for NP and NPEOs. Satisfactory recoveries between 66 and 79% were obtained for environmental samples. The results showed that DLLME is a simple, rapid and sensitive analytical method for the preconcentration of trace amounts of alkylphenols and their ethoxylates in environmental water samples.  相似文献   

4.
Beauvericin (BEA), a supercritical fluid extraction with supercritical carbon dioxide from maize was investigated. Extraction efficiencies under several different extraction conditions were examined. Pressure, temperature, extraction time, organic modifier and water matrix content (10%) were investigated. The best extraction conditions were at a temperature of 60 °C, 3200 psi, for 30 min static extraction time and methanol as modifier solvent. Extraction recovery of 36% without modifier by adding water to the matrix in the extraction vessel (reproducibility relative standard deviations (R.S.D.)=3-5%) were recorded. Extraction recovery of 76.9% with methanol as co-solvent (reproducibility R.S.D.=3-5%) was obtained. Data shows that SFE gives a lower BEA recovery compared to conventional extraction protocol with organic solvents while SFE with modifier and conventional extraction yields are comparable. BEA extract contents were determined by high pressure liquid chromatography (HPLC) with a diode array detector (DAD) at 205 nm and BEA peak confirmed by LC-MS. Acetonitrile-water as mobile phase and column C-18 were both tested. Instrumental and analytical parameters were optimized in the range linear interval from 1 to 500 mg kg−1 and reached a detection limit of 2 ng.  相似文献   

5.
Hydrophilic interaction liquid chromatography (HILIC) is a fast growing separation technique for hydrophilic and polar analytes. In this work, we combine the unique selectivity of carbon surfaces with the high efficiency of core–shell silica. First, 5 μm core–shell silica is electrostatically coated with 105 nm cationic latex bearing quaternary ammonium groups. Then 50 nm anionic carbon nanoparticles are anchored onto the surface of the latex coated core–shell silica particles to produce a hybrid carbon–silica phase. The hybrid phase shows different selectivity than ten previously classified HILIC column chemistries and 36 stationary phases. The hybrid HILIC phase has shape selectivity for positional isomeric pairs (phthalic/isophthalic and 1-naphthoic/2-naphthoic acids). Fast and high efficiency HILIC separations of biologically important carboxylates, phenols and pharmaceuticals are reported with efficiencies up to 85,000 plates m−1. Reduced plate height of 1.9 (95,000 plates m−1) can be achieved. The hybrid phase is stable for at least 3 months of usage and storage under typical HILIC eluents.  相似文献   

6.
Strongly polar phenolic acids are weakly retained and often poorly separated in reversed-phase (RP) liquid chromatography. We prepared zwitterionic polymethacrylate monolithic columns for micro-HPLC by in situ co-polymerization in fused-silica capillaries. The capillary monolithic columns prepared under optimized polymerization conditions show some similarities with the conventional particulate commercial ZIC-HILIC silica-based columns, however have higher retention and better separation selectivity under reversed-phase conditions, so that they can be employed for dual-mode HILIC-RP separations of phenolic acids on a single column. The capillary polymethacrylate monolithic sulfobetaine columns show excellent thermal stability and improved performance at temperatures 60–80 °C. The effects of the operation conditions on separation were investigated, including the type and the concentration of the organic solvent in the aqueous-organic mobile phase (acetonitrile and methanol), the ionic strength of the acetate buffer and temperature. While the retention in the RP mode decreases at higher temperatures in mobile phases with relatively low concentrations of acetonitrile, it is almost independent of temperature at HILIC conditions in highly organic mobile phases. The best separation efficiency can be achieved using relatively high acetate buffer ionic strength (20–30 mmol L−1) and gradient elution with alternately increasing (HILIC mode) and decreasing (RP mode) concentration of aqueous buffer in aqueous acetonitrile. Applications of the monolithic sulfobetaine capillary columns in alternating HILIC-RP modes are demonstrated on the analysis of phenolic acids in a beer sample.  相似文献   

7.
Ascorbic acid (AA) and dehydroascorbic acid (DHA) are small polar molecules difficult to be retained in conventional chromatographic RP systems. Hydrophilic interaction liquid chromatography (HILIC) using Obelisk R (100 × 3.2 mm, 5 μm, Sielc) analytical column and isocratic elution by ammonium acetate buffer pH 4.2 was found to be successful at this task, while other tested HILIC columns – Obelisk N (100 × 3.2 mm, 5 μm, Sielc) and Luna HILIC (100 × 3.0 mm, 3 μm, Phenomenex) were unsuccessful for the purposes of analysis. Charged aerosol detection (CAD) has recently become a new alternative universal detection system in HPLC, and was extremely convenient for the simultaneous analysis of AA and DHA without the need of subtraction approach and oxidation/reduction step. CAD response was found linear in defined range in spite of the fact that CAD is designated as non-linear detection method. A simple and fast HILIC-CAD method was applied for the analysis of pharmaceutical preparations containing AA. Method validation was performed including parameters of precision, accuracy, linearity, limit of detection and limit of quantitation (LOQ). The method was fast, accurate and precise for both detectors with LOQAA 5 μg/ml for UV detection and 10 μg/ml for CAD, respectively. DHA was detected only by CAD within tested concentration range with LOQDHA 1 μg/ml.  相似文献   

8.
Sub‐2‐µm particle size hydrophilic interaction liquid chromatography [HILIC] combined with mass spectrometry has been increasing in popularity as a complementary technique to reversed‐phase LC for the analysis of polar analytes. The organic‐rich mobile phase associated with HILIC techniques provides increases in compound ionization, due to increased desolvation efficiency during electrospray ionisation mass spectrometric (ESI‐MS) analysis. Although recent publications illustrated selectivity and response comparisons between reversed‐phase LC/MS and HILIC LC/MS, there are limited discussions evaluating the optimisation of the mass spectrometry parameters regarding analytes and alternative mobile phases. The use of acetone as an alternative organic modifier in HILIC has been investigated with respect to signal‐to‐noise in ESI‐MS for a variety of polar analytes. Analyte reponses were measured based on a variety of cone and capillary voltages at low and high pH in both acetone and acetonitrile. In order to visualise compound behaviour in the ESI source, surface plots were constructed to assist in interpreting the observed results. The use of acetone in ESI is complicated at low m/z due to the formation of condensation products. Favourable responses were observed for certain analytes and we envisage offering an insight into the use of acetone as an alternative to acetonitrile under certain analytical conditions for particular compound classifications for small molecule analysis. We also highlight the importance of optimising source voltages in order to obtain the maximum signal stability and sensitivity, which are invariably, highly solvent composition dependent parameters. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
A new concept of liquid–liquid–liquid microextraction (LLLME) was introduced based on applying two immiscible organic solvents in lumen and wall pores of hollow fiber (HF). With this methodology, analytes of interest can be extracted from aqueous sample, into a thin layer of organic solvent (dodecane) sustained in the pores of a porous hollow fiber, and further into a μL volume of organic acceptor (acetonitrile or methanol) located inside the lumen of the hollow fiber. Some chlorophenols (CPs) were selected as model compounds for developing and evaluating of the method performance. The analysis was performed by gas chromatography–electron capture detection (GC–ECD) without derivatization. The factors affecting the HF-LLLME of target compounds were investigated and the optimal extraction conditions were established. Under the optimum conditions, preconcentration factors in a range of 208–895 were obtained. The performance of the proposed method was studied in terms of linear dynamic ranges (LDRs from 0.02 to 100 ng mL−1), linearity (R2 ≥ 0.995), precision (RSD % ≤ 8.1) and limits of detection (LODs in the range of 0.006–0.2 ng mL−1). In addition to preconcentration, HF-LLLME also served as a technique for sample clean-up.  相似文献   

10.
In this study, a sample pretreatment method was developed for the determination of 13 endocrine disrupting chemicals (EDCs) in sediment samples based on the combination of subcritical water extraction (SWE) and dispersed liquid–liquid microextraction (DLLME). The subcritical water that provided by accelerated solvent extractor (ASE) was the sample solution (water) for the following DLLME and the soluble organic modifier that spiked in the subcritical water was also used as the disperser solvent for DLLME in succession. Thus, several important parameters that affected both SWE and DLLME were investigated, such as the extraction solvent for DLLME (chlorobenzene), extraction time for DLLME (30 s), selection of organic modifier for SWE (acetone), volume of organic modifier (10%) and extraction temperature for SWE (150 °C). In addition, good chromatographic behavior was achieved for GC–MS after derivatisation by using N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA). As a result, proposed method sensitive and reliable with the limits of detection (LODs) ranging from 0.006 ng g−1 (BPA) to 0.639 ng g−1 (19-norethisterone) and the relative standard deviations (RSDs) between 1.5% (E2) and 15.0% (DES). Moreover, the proposed method was compared with direct ASE extraction that reported previously, and the results showed that SWE–DLLME was more promising with recoveries ranging from 42.3% (dienestrol) to 131.3% (4,5α-dihydrotestosterone), except for diethylstilbestrol (15.0%) and nonylphenols (29.8%). The proposed method was then successfully applied to determine 13 EDCs sediment of Humen outlet of the Pearl River, 12 of target compounds could be detected, and 10 could be quantitative analysis with the total concentration being 39.6 ng g−1, and which indicated that the sediment of Humen outlet was heavily contaminated by EDCs.  相似文献   

11.
Quantitative screening for a broad range of drugs in blood is regularly required to assess drug abuse and poisoning within analytical toxicology. Mass spectrometry-based procedures suffer from the large amount of work required to maintain quantitative calibration in extensive multi-compound methods. In this study, a quantitative drug screening method for blood samples was developed based on ultra-high performance liquid chromatography with two consecutive detectors: a photodiode array detector and a corona charged aerosol detector (UHPLC–DAD–CAD). The 2.1 mm × 150 mm UHPLC column contained a high-strength silica C18 bonded phase material with a particle size of 1.8 μm, and the mobile phase consisted of methanol/0.1% trifluoroacetic acid in gradient mode. Identification was based on retention time, UV spectrum and the response ratio from the two detectors. Using historic calibration over a one-month period, the median precision (RSD) of retention times was 0.04% and the median accuracy (bias) of quantification 6.75%. The median precision of the detector response ratio over two orders of magnitude was 12%. The applicable linear ranges were generally 0.05–5 mg L−1. The method was validated for 161 compounds, including antipsychotics, antidepressants, antihistamines, opioid analgesics, and adrenergic beta blocking drugs, among others. The main novelty of the method was the proven utility of the response ratio of DAD to CAD, which provided the additional identification efficiency required. Unlike with mass spectrometry, the high stability of identification and quantification allowed the use of facile historic calibration.  相似文献   

12.
Hydrophilic interaction liquid chromatography (HILIC) can be performed on titania. To better understand the retention mechanisms on titania, a series of model carboxylates were used. Increasing acetonitrile above 60% dramatically increased the retention and efficiency for carboxylates. The effect of buffer type, buffer concentration, buffer pH and column temperature were also studied. Multiple retention mechanisms are operative on titania, and whether electrostatic repulsion, ligand exchange or HILIC dominates retention and separation depends on the eluent conditions. Guidelines for separations on titania are: (1) higher %ACN most improves retention and efficiency; (2) higher salt concentration increases retention; (3) elution strength is in the order acetate ? malate < methyl phosphonate ? phosphate; (4) electrostatic repulsion (ERLIC) is more operative at low %ACN than high %ACN. A bare titania column (150 mm × 4.6 mm I.D., 5 μm) was used for the separation of diphenylacetate, 4-nitrobenzoate, benzoate, 4-aminobenzoate, 4-hydroxybenzoate, phthalate, 3-aminophthalate, 1,3,5-benzenetricarboxylate, 1,2,4-benzenetricarboxylate, 1,2,4,5-benzenetetracarboxylate, benzenepentabenzoate and mellitate under HILIC conditions based on these guidelines, with efficiencies of 2800–55,000 plates/m.  相似文献   

13.
The responses of four different types of aerosol detectors have been evaluated and compared to establish their potential use as a universal detector in conjunction with ultra high pressure liquid chromatography (UHPLC). Two charged-aerosol detectors, namely Corona CAD and Corona Ultra, and also two different types of light-scattering detectors (an evaporative light scattering detector, and a nano-quantity analyte detector [NQAD]) were evaluated. The responses of these detectors were systematically investigated under changing experimental and instrumental parameters, such as the mobile phase flow-rate, analyte concentration, mobile phase composition, nebulizer temperature, evaporator temperature, evaporator gas flow-rate and instrumental signal filtering after detection. It was found that these parameters exerted non-linear effects on the responses of the aerosol detectors and must therefore be considered when designing analytical separation conditions, particularly when gradient elution is performed. Identical reversed-phase gradient separations were compared on all four aerosol detectors and further compared with UV detection at 200 nm. The aerosol detectors were able to detect all 11 analytes in a test set comprising species having a variety of physicochemical properties, whilst UV detection was applicable only to those analytes containing chromophores. The reproducibility of the detector response for 11 analytes over 10 consecutive separations was found to be approximately 5% for the charged-aerosol detectors and approximately 11% for the light-scattering detectors. The tested analytes included semi-volatile species which exhibited a more variable response on the aerosol detectors. Peak efficiencies were generally better on the aerosol detectors in comparison to UV detection and particularly so for the light-scattering detectors which exhibited efficiencies of around 110,000 plates per metre. Limits of detection were calculated using different mobile phase compositions and the NQAD detector was found to be the most sensitive (LOD of 10 ng/mL), followed by the Corona CAD (76 ng/mL), then UV detection at 200 nm (178 ng/mL) using an injection volume of 25 μL.  相似文献   

14.
The application of sulfur microparticles as efficient adsorbents for the solid-phase extraction (SPE) and determination of trace amounts of 10 polycyclic aromatic hydrocarbons (PAHs) was investigated in sea water and wastewater samples using high performance liquid chromatography coupled with an ultraviolet detector (HPLC–UV). Parameters influencing the preconcentration of PAHs such as the amount of sulfur, solution flow rate and volume, elution solvent, type and concentration of organic modifier, and salt effect were examined. The results showed that at a flow rate of 10 mL min−1 for the sample solutions (100 mL), the PAHs could be adsorbed on the sulfur microparticles and then eluted by 2.0 mL of acetonitrile. For HPLC–UV analysis of extracted PAHs, the calibration curves were linear in the range of 0.05–80.0 μg L−1; the coefficients of determinations (r2) were between 0.9934 and 0.9995. The relative standard deviations (RSDs) for eight replicates at two concentration levels (0.5 and 4.0 μg L−1) of PAHs were lower than 7.3%, under optimized conditions. The limits of detection (LODs, <!-- no-mfc -->S/N<!-- /no-mfc --> = 3) of the proposed method for the studied PAHs were 0.007–0.048 μg L−1. The recoveries of spiked PAHs (0.5 and 4 μg L−1) in the wastewater and sea water samples ranged from 78% to 108%. The simplicity of experimental procedure, high extraction efficiency, short sample analysis, and using of low cost sorbent demonstrate the potential of this approach for routine trace PAH analysis in water and wastewater samples.  相似文献   

15.
Sun M  Du WB  Fang Q 《Talanta》2006,70(2):392-396
In this work, a miniaturized liquid-liquid extraction system under stopped-flow manipulation mode with spectrometric detection was developed. A Teflon AF liquid-core waveguide (LCW) capillary was used to serve as both extraction channel for organic solvent flow and adsorption detection flow cell. Gravity induced hydrostatic pressure was used to drive the organic and aqueous phases through the extraction channels. During extraction process, a stable organic and aqueous phase interface was formed at the outlet of the capillary, through which the analyte in the flowing aqueous stream was extracted into the stationary organic solvent in capillary. The absorbance of the analyte extracted into the organic solvent was measured in situ by a spectrometric detection system with light emitting diode (LED) as light source and photodiode as absorbance detector. The performance of the system was demonstrated in the determination of sodium dodecyl sulfate (SDS) extracted as an ion pair with methylene blue into chloroform. The precision of the measured absorbance for a 5 mg L−1 SDS standard was 6.1% R.S.D. (n = 5). A linear response range of 1-10 mg L−1 SDS was obtained with 5 min extraction period. The limit of detection (LOD) for SDS based on three times standard deviation of the blank response was 0.25 mg L−1.  相似文献   

16.
In this work a LC–MS/MS method for the determination of two quaternary ammonium growth regulators (chlormequat and mepiquat) in food is reported. The separation was based on hydrophilic interaction liquid chromatography (HILIC) without the use of ion-pair reagents. A gradient elution of acetonitrile and formic acid/ammonium formate buffer from 60 to 40% acetonitrile was enough to achieve a resolution >1.5 in less than 4.0 min. The HILIC system was coupled to a triple quadrupole mass spectrometer equipped with a heated electrospray probe (H-ESI) providing sub-pg LODs in SRM mode. A straightforward sample treatment (SPE C18 clean-up) was enough to provide MLODs at low ppb levels when analysing a range of food samples that covered different kinds of matrices such as fresh fruit, vegetables, fruit juices, baby food, bread, coffee and beer. Chlormequat was found in seven samples (0.8–126 ng/g) but mepiquat was only detected in bread and coffee samples (0.9–166 ng/g).  相似文献   

17.
Jin J  Zhang Z  Li Y  Qi P  Lu X  Wang J  Chen J  Su F 《Analytica chimica acta》2010,678(2):183-188
The enrichment of polycyclic aromatic hydrocarbons (PAHs) in water samples with magnesium oxide (MgO) microspheres was evaluated, and four 3-5-ring PAHs were used as probes to validate the adsorption capacity of the material. Factors affecting the recovery of PAHs were investigated in detail, including the type and concentration of organic modifiers, elution solvents, particle size of the adsorbent, volume and flow rate of the samples, and the lifetime of MgO cartridges. The recoveries of four PAHs extracted from 20 mL of seawater spiked with standard PAHs ranged from 85.8% to 102.0% under the optimised conditions. The limits of detection varied from 1.83 ng L−1 to 16.03 ng L−1, indicating that the analytical method was highly sensitive. Additionally, the proposed method was successfully used to enrich PAHs in seawater. Compared to conventional methods, the proposed method consumed less organic modifier (5% acetone), and cheaper sorbents with comparable extraction efficiency were employed.  相似文献   

18.
The occurrence of various regions of phase equilibrium in three-component systems of water–alcohol (ketone)–sodium chloride was studied. As for methanol and ethanol there are two regions: the liquid single-phase region and the two-phase region of liquid + solid. For propanol and acetone (of a complete miscibility with water) there also occurs, however, the two-phase region of liquid + liquid, and the three-phase region of liquid + liquid + solid. Both phenomena occur while salting-out the organic solvents from the water solution by sodium chloride. The systems containing butanol, pentanol, methylethyl- and diethylketone (of an incomplete miscibility with water) confirm the occurrence of the system regions, similar to those for propanol or acetone. The results of the experiments were explained by considering competive molecular interactions between: water and sodium chloride; water and organic solvent; organic solvent and sodium chloride.  相似文献   

19.
A simple, precise, and accurate hydrophilic interaction liquid chromatographic (HILIC) method has been developed for the determination of five aromatic amines in environmental water samples. Chromatography was carried out on a bare silica column, using a mixture of acetonitrile and a buffer of NaH2PO4–H3PO4 (pH 1.5, containing 10 mM NaH2PO4) (85:15, v/v) as a mobile phase at a flow rate of 1 mL min−1. Aromatic amines were detected by UV absorbance at 254 nm. The linear range of amines was good (r2 > 0.998) and limit of detection (LOD) within 0.02–0.2 mg L−1 (S/N = 3). The retention mechanism for the analytes under the optimum conditions was determined to be a combination of adsorption, partition and ionic interactions. The proposed method was applied to the environmental water samples. Aromatic amines were isolated from aqueous samples using solid-phase extraction (SPE) with Oasis HLB cartridges. Recoveries of greater than 75% with precision (RSD) less than 12% were obtained at amine concentrations of 5–50 μg L−1 from 100 mL river water and influents from a wastewater treatment plant (WWTP). The present HILIC technique proved to be a viable method for the analysis of aromatic amines in the environmental water samples.  相似文献   

20.
CAD (charged aerosol detector) has recently become a new alternative detection system in HPLC. This detection approach was applied in a new HPLC method for the determination of three of the major statins used in clinical treatment—simvastatin, lovastatin and atorvastatin.The method was optimized and the influence of individual parameters on CAD response and sensitivity was carefully studied. Chromatography was performed on a Zorbax Eclipse XDB C18 (4.6 mm × 75 mm, 3.5 μm), using acetonitrile and formic acid 0.1% as mobile phase. The detection was performed using both CAD (20 pA range) and DAD (diode array detector—238 nm) simultaneously connected in series. In terms of linearity, precision and accuracy, the method was validated using tablets containing atorvastatin and simvastatin.The CAD is designated to be a non-linear detector in a wide dynamic range, however, in this application and in the tested concentration range its response was found to be perfectly linear. The limits of quantitation (0.1 μg/ml) were found to be two times lower than those of UV detection.  相似文献   