首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A modified Rheodyne 7520 microsample injector was used as a new solid phase microextraction (SPME)–liquid chromatography (LC) interface. The modification was focused on the construction of a new sample rotor, which was built by gluing two sample rotors together. The new sample rotor was further reinforced with 3 pieces of stainless steel tubing. The enlarged central flow passage in the new sample rotor was used as a desorption chamber. SPME fiber desorption occurred in static mode. But all desorption solvent in the desorption chamber was injected into LC system with the interface. The analytical performance of the interface was evaluated by SPME–LC analysis of PAHs in water. At least 90% polycyclic aromatic hydrocarbons (PAHs) were desorbed from a polyacrylonitrile (PAN)/C18 bonded fuse silica fiber in 30 s. And injection was completed in 20 s. About 10–20% total carryovers were found on the fiber and in the interface. The carryover in the interface was eliminated by flushing the desorption chamber with acetonitrile at 1 mL min−1 for 2 min. The repeatability of the method was from 2% to 8%. The limit of detection (LOD) was in the mid pg mL−1 range. The linear ranges were from 0.1 to 100 ng mL−1. The new SPME–LC interface was reliable for coupling SPME with LC for both qualitative and quantitative analysis.  相似文献   

2.
In this work, a C18 composite solid-phase microextraction (SPME) fiber was prepared with a new method and applied to the analysis of organochlorine pesticides (OCPs) in water sample. A stainless steel wire (o.d. 127 μm) was used as the substrate, and a mixture of the C18 particle (3.5 μm) and the 184 silicone was used as the coating material. During the process of fiber preparation, a section of capillary column was used to fix the mixture onto the stainless steel wire and to ensure the constant of coating thickness. The prepared fiber showed excellent thermal stability and solvent resistance. By coupling with gas chromatography–mass spectrometry (GC–MS), the fiber exhibited wide linearity (2–500 ng L−1) and good sensitivity for the determination of six OCPs in water samples, the OCPs tested included hexachlorobezene, trans-chlordane, cis-chlordane, o,p-DDT, p,p-DDT and mirex. Not only the extraction performance of the newly prepared fiber was more than seven times higher than those of commercial fibers, the limits of detections (LODs) (0.059–0.151 ng L−1) for OCPs achieved under optimized conditions were also lower than those of reported SPME methods. The fiber was successfully applied to the determination of OCPs in real water samples by using developed SPME–GC–MS method.  相似文献   

3.
Surface reversible addition-fragmentation chain transfer (RAFT) polymerization method was firstly applied to the preparation of molecularly imprinted polymer (MIP) coated silicon solid-phase microextraction (SPME) fibers. With Sudan I as template, an ultra-thin MIP coating with about 0.55-μm thickness was obtained with homogeneous structure and controlled composition, due to the controllable radical growing and chain propagation in surface RAFT polymerization. The MIP-coated fibers were found with enhanced selectivity coefficients (3.0–6.5) to Sudan I–IV dyes in contrast with those reported in our previous work. Furthermore, the ultra-thin thickness of MIP coating was helpful to the effective elution of template and fast adsorption/desorption kinetics, so only about 18 min was needed for MIP-coated SPME operation. The detection limits of 21–55 ng L−1 were achieved for four Sudan dyes, when MIP-coated SPME was coupled with liquid chromatography (LC) and mass spectrometry (MS) detection. The MIP-coated SPME–LC–MS/MS method was tested for the monitoring of ultra trace Sudan dyes in spiked chilli tomato sauce and chilli pepper samples, and high enrichment effect, remarkable matrix peaks-removing capability, and consequent high sensitivities were achieved to four Sudan dyes.  相似文献   

4.
We report a new in-tube solid phase microextraction approach named electrochemically controlled in-tube solid phase microextraction (EC in-tube SPME). This approach, which combined electrochemistry and in-tube SPME, led to decrease in total analysis time and increase in sensitivity. At first, pyrrole was elctropolymerized on the inner surface of a stainless steel tube. Then, the polypyrrole (PPy)-coated in-tube SPME was coupled on-line to liquid chromatography (HPLC) to achieve automated in-tube SPME–HPLC analysis. After the completion of EC-in-tube SPME–HPLC setup, the PPy-coated tube was used as working electrode for uptake of diclofenac as target analyte. Extraction ability of the tube in presence and in absence of applied electrical field was investigated. It was found that, under the same extraction conditions, the extraction efficiency could be greatly enhanced by using the constant potential. Important factors are also optimized. The detection limit (S/N = 3) and precision were 0.1 μg L−1 and 4.4%, respectively.  相似文献   

5.
A novel solid-phase microextraction(SPME) fiber was prepared using sol–gel technology with ethoxylated nonylphenol as a fiber coating material. The fiber was employed to develop a headspace SPME–GC–MS method suitable for quantification of 13 polycyclic aromatic hydrocarbons (PAHs) in water samples. Surface characteristics of the fibers were inspected by energy dispersive X-ray (EDX) spectroscopy as well as by scanning electron microscopy (SEM). The SEM measurements showed the presence of highly porous nano-sized particles in the coating. Important parameters affecting the extraction efficiency such as extraction temperature and time, desorption conditions as well as ionic strength have been evaluated and optimized. In the next step, the validation of the new method have been performed, finding it to be specific in the trace analysis of PAHs, with the limit of detection (LOD) ranging from 0.01 to 0.5 μg L−1 and the linear range from the respective LOD to 200 μg L−1with RSD amounting to less than 8%. The thermal stability of the fibers was investigated as well and they were found to be durable at 280 °C for 345 min. Furthermore, the proposed method was successfully applied for quantification of PAHs in real water samples.  相似文献   

6.
A new fiber for solid-phase microextraction (SPME) employing a metallic support coated with an inorganic material is proposed. A nitinol alloy (NiTi) was used as the support material due to its super elasticity and shape memory properties. Zirconium oxide (ZrO2) was electrodeposited onto NiTi using chronoamperometry. The surface characteristics and morphology of the coated and uncoated support were evaluated through scanning electronic microscopy and dispersive energy microanalysis. This assembly was applied in the extraction of three halophenols from aqueous samples. A multivariate approach was used for optimization of the variables involved in the system. The Doehlert matrix was used for evaluation of the best derivatization conditions and a Box-Behnken design to obtain the best extraction conditions. In order to investigate the repeatability, one fiber was used for six extraction tests under similar conditions and the relative standard deviations (R.S.D.) were lower than 12.5%. Detection limits were lower than 0.30 ng mL−1. Correlation coefficients were higher than 0.997. Extraction efficiency of the NiTi-ZrO2 fiber was similar to a PDMS 7 μm commercial fiber, even though it had a lower coating thickness of 1.35 μm. Considering the amount extracted per unit volume, the NiTi-ZrO2 fiber had a better extraction profile when compared to commercial fibers. The new SPME fiber has a lifetime of over 500 extractions. Thus, it is a promising alternative for low-cost analysis, as the proposed fiber is robust, and easily and inexpensively prepared.  相似文献   

7.
The determination of a group of eighteen pollutants in waters, including polycyclic aromatic hydrocarbons and substituted phenols, is conducted in direct-immersion solid-phase microextraction (SPME) using the polymeric ionic liquid (PIL) poly(1-vinyl-3-hexadecylimidazolium) bis[(trifluoromethyl)sulfonyl]imide as a novel coating material. The performance of the PIL fiber coating in the developed IL-SPME-gas chromatography (GC)–mass spectrometry (MS) method is characterized by average relative recoveries of 92.5% for deionized waters and 90.8% for well waters, average precision values (as relative standard deviations, RSD%) of 11% for deionized waters and 12% for well waters, using a spiked level of 5 ng mL−1. The detection limits oscillate from 0.005 ng mL−1 for fluoranthene to 4.4 ng mL−1 for 4-chloro-3-methylphenol, when using an extraction time of 60 min with 20 mL of aqueous sample. The extraction capabilities of the PIL fiber have been compared with the commercial SPME coatings: polydimethylsyloxane (PDMS) 30 μm, PDMS 100 μm and polyacrylate (PA) 85 μm. The PIL fiber is superior to the PDMS 30 μm for all analytes studied. A qualitative study was also carried out to compare among the nature of the coating materials by normalizing the coating thickness. The PIL material was shown to be more efficient than the PDMS material for all analytes studied. The PIL coating was also adequate for nonpolar analytes whereas the PA material was more sensitive for polar compounds.  相似文献   

8.
An in situ application of solid-phase microextraction (SPME) as a sampling and sample preparation method coupled to HPLC-MS/MS for direct monitoring of ochratoxin A (OTA) distribution at different locations in a single cheese piece is proposed. To be suited to the acidic analyte, the extraction phase (carbon-tape SPME fiber) was acidified with aqueous solution of HCl at pH 2, instead of the traditional sample pre-treatment with acids before SPME sampling. For calibration, kinetic on-fiber-standardization was used, which allowed the use of short sampling time (20 min) and accurate quantification of the OTA in the semi-solid cheese sample. In addition, the traditional kinetic calibration that used deuterated compounds as standards was extended to use a non-deuterated analogue ochratoxin B (OTB) as the standard of the analyte OTA, which was supported by both theoretical discussion and experimental verification. Finally, the miniaturized SPME fiber was adopted so that the concentration distribution of OTA in a small-sized cheese piece could be directly probed. The detection limit of the resulting SPME method in semi-solid gel was 1.5 ng/mL and the linear range was 3.5–500 ng/mL. The SPME–LC-MS/MS method showed good precision (RSD: ∼10%) and accuracy (relative recovery: 93%) in the gel model. The direct cheese analysis showed comparable accuracy and precision to the established liquid extraction. As a result, the developed in situ SPME–LC-MS/MS method was sensitive, simple, accurate and applicable for the analysis of complicated lipid-rich samples such as cheese.  相似文献   

9.
Novel solid-phase microextraction fibers were prepared based on sol–gel technique. Commonly used fused silica substrate was replaced by titanium wire which provided high strength and longer fiber life cycle. Titanium isopropoxide was employed as the precursor which provides a sol solution containing Ti–OH groups and shows more tendencies to the molecularly similar group on the substrate. Three different polymers, poly (dimethylsiloxane) (PDMS), poly(ethylenepropyleneglycol)-monobutyl ether (Ucon) and polyethylene glycol (PEG) were employed as coating polymer in preparing three different fibers. The applicability of these fibers was assessed for the headspace SPME (HS-SPME) of benzene, toluene, ethylbenzene and xylenes (BTEX) from water sample followed by gas chromatography–mass spectrometry (GC–MS). Effects of different parameters such as fiber coating type, extraction condition, desorption condition were investigated and optimized. Under the optimized conditions, LODs and LOQs of 0.75–10 μg L−1 (S/N = 3) and 1–20 μg L−1 (S/N = 10) were respectively obtained. The method showed linearity in the range of 10–25,000 μg L−1 with correlation coefficient of >0.99. The relative standard deviation was less than 8%.  相似文献   

10.
A novel solid-phase microextraction (SPME) fiber was prepared by polymerization of an organic–inorganic hybrid polymeric coating on an anodized and derived Ti wire, and applied for the analysis of polycyclic aromatic hydrocarbons from environmental samples followed by high performance liquid chromatography (HPLC) analysis. A polyhedral oligomeric silsesquioxane (POSS) reagent containing methacryl substituent groups was used as an organic–inorganic hybrid cross-linker, and copolymerized with methyl methacrylate (MMA) to fabricate the hybrid coating via thermally initiated free radical polymerization in a glass capillary mold. The prepared fiber can be easily withdrawn from the glass capillary mold by controlling the polymerization conditions, especially polymerization solvent. A homogeneous and porous coating with thickness of about 100 μm was achieved using ethanol as polymerization solvent at the mass ratio of MMA to POSS as 1:0.5. High chemical and mechanical stability, as well as excellent durability for more than 100 times extractions with almost undiminished extraction efficiency were achieved due to the chemical immobilization and crosslinked hybrid coating. The proposed fiber showed much better extraction performance than the 100 μm commercial polydimethylsiloxane fiber for extracting PAHs from aqueous sample. The developed SPME-HPLC method for the determination of PAHs using the MMA–POSS hybrid coating achieved good linearity with good correlation coefficients (R = 0.991–0.999) and low detection limits in the range of 0.006 to 0.05 ng mL−1 (S/N = 3). The proposed fiber was successfully applied to the extraction of PAHs from environmental water samples with recoveries of 82–104% for river water, 83–103% for pool water, and 79–98% for wastewater, respectively.  相似文献   

11.
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes (MWCNTs)/Nafion was developed and applied for the extraction of polar aromatic compounds (PACs) in natural water samples. The characteristics and the application of this fiber were investigated. Electron microscope photographs indicated that the MWCNTs/Nafion coating with average thickness of 12.5 μm was homogeneous and porous. The MWCNTs/Nafion coated fiber exhibited higher extraction efficiency towards polar aromatic compounds compared to an 85 μm commercial PA fiber. SPME experimental conditions, such as fiber coating, extraction time, stirring rate, desorption temperature and desorption time, were optimized in order to improve the extraction efficiency. The calibration curves were linear from 0.01 to 10 μg mL−1 for five PACs studied except p-nitroaniline (from 0.005 to 10 μg mL−1) and m-cresol (from 0.001 to 10 μg mL−1), and detection limits were within the range of 0.03–0.57 ng mL−1. Single fiber and fiber-to-fiber reproducibility were less than 7.5 (n = 7) and 10.0% (n = 5), respectively. The recovery of the PACs spiked in natural water samples at 1 μg mL−1 ranged from 83.3 to 106.0%.  相似文献   

12.
Halloysite nanotubes-titanium dioxide (HNTs-TiO2) as a biocompatible environmentally friendly solid-phase microextraction (SPME) fiber coating was prepared. HNTs-TiO2 was chemically coated on the surface of a fused-silica fiber using a sol–gel process. Parathion as an organophosphorus pesticide was selected as a model compound to investigate the extraction efficiency of the fiber. The extracted analyte was detected by negative corona discharge-ion mobility spectrometer (NCD-IMS). The effective parameters on the extraction efficiency, such as salt effect, extraction temperature and extraction time were investigated and optimized. The extraction efficiency of HNTs-TiO2 fiber was compared with bare-silica (sol–gel based coating without HNTs-TiO2), HNTs, carbon nanotubes and commercial SPME fibers (PA, PDMS, and PDMS–DVB). The HNTs-TiO2 fiber showed highest extraction efficiency among the studied fibers. The intra- and inter-day relative standard deviations were found to be 4.3 and 6.3%, respectively. The limit of detection and limit of quantification values were 0.03 and 0.1 μg L−1, respectively. The dynamic range of the method was in the range of 0.1–25 μg L−1. The spiking recoveries were between 85 (±9) and 97 (±6). The SPME–HNTs-TiO2 combined with NCD–IMS was successfully applied for the determination of parathion in apple, strawberry, celery and water samples.  相似文献   

13.
In this work, a molecular sol–gel imprinting approach has been introduced to produce a fiber coating for selective direct immersion solid-phase microextraction (SPME) of caffeine. The polymerization mixture was composed of vinyl trimethoxysilane and methacrylic acid as vinyl sol–gel precursor and functional monomer, respectively. Caffeine was used as template molecule during polymerization process. The prepared fibers could be coupled directly to gas chromatography/mass spectrometry (GC/MS) and used for trace analysis of caffeine in a complex sample such as human serum. The parameters influencing SPME such as time, temperature and stirring speed were optimized. The prepared coating showed good selectivity towards caffeine in the presence of some structurally related compounds. Also, it offered high imprinting capability in comparison to bare fiber and non-imprinted coating. Linear range for caffeine detection was 1–80 μg mL−1 and the limit of detection was 0.1 μg mL−1. The intra-day and inter-day precisions of the peak areas for five replicates were 10 and 16%, respectively.  相似文献   

14.
This work describes a new approach for the determination of trimethylamine (TMA) in water and air by liquid chromatography (LC). The assay is based on the employment of a solid-phase microextraction (SPME) fiber for sampling and for derivatization of the analyte with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC). The fiber, with a Carbowax-templated resin −50 μm coating, was first immersed into a solution of the reagent. Once loaded with the reagent, the fiber was immersed into the water samples or exposed to the air samples in order to extract and to derivatize the analyte. Finally, the fiber was placed into a HPLC-SPME interface to desorb and transfer the TMA-FMOC derivative to the LC equipment. A comparative study of the analytical characteristics of the procedure in water and air samples was carried out. Under optimized conditions, the proposed approach permits the quantification of TMA in solution within the 1.0-10.0 μg/ml interval and in air within the 25-200 mg/m3 interval. The limits of detection were 0.25 μg/ml and 12 mg/m3 (25 °C, 1.013 × 10−5 Pa) in water and air, respectively. The utility of the proposed method for determining TMA in different kind of samples is discussed.  相似文献   

15.
5-Bromo-5-nitro-1,3-dioxane (bronidox) is a bromine-containing preservative often used in rinse-off cosmetics but also subjected to several restrictions according to the European Cosmetic Products Regulation. Thus, as a part of a quality control procedure, analytical methods for the determination of this compound in different types of cosmetics are required. In the present work, a solvent-free and simple methodology based on solid-phase microextraction (SPME) followed by gas chromatography with microelectron capture detection (GC-μECD) has been developed and validated for the determination of bronidox in cosmetic samples such as shampoos, body cleansers or facial exfoliants. As far as we know, this is the first application of SPME to this preservative. Negative matrix effects due to the complexity of the studied samples were reduced by dilution with ultrapure water. The influence of several factors on the SPME procedure such as fiber coating, extraction temperature, salt addition (NaCl) and sampling mode has been assessed by performing a 24-factorial design. After optimization, the recommended procedure was established as follows: direct solid-phase microextraction (DSPME), using a PDMS/DVB coating, of 10 mL of diluted cosmetic with 20% NaCl, at room temperature, under stirring for 30 min. Using these suggested extraction conditions, linear calibration could be achieved, with limits of detection (LOD) and quantification (LOQ) well below the maximum authorized concentration (0.1%) established by the European legislation. Relative standard deviations (RSD) lower than 10% were obtained for both within a day and among days precision. The method was applied to diverse types of formulations spiked with bronidox at different concentration levels (0.008–0.10%); these samples were quantified by external calibration and satisfactory recoveries (≥70%) were obtained in all cases. Finally, the SPME–GC-μECD methodology was applied to the analysis of several cosmetics labeled or not as containing bronidox. The presence of this preservative in some of these samples was confirmed by GC–MS.  相似文献   

16.
A new fiber for solid-phase microextraction (SPME) was prepared employing cork as a coating. The morphology and composition of the cork fiber was evaluated by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR), respectively. The proposed fiber was used for the determination of polycyclic aromatic hydrocarbons (PAHs) in river water samples by gas chromatography–selected ion monitoring–mass spectrometry (GC–SIM–MS). A central composite design was used for optimization of the variables involved in the extraction of PAHs from water samples. The optimal extraction conditions were extraction time and temperature of 60 min and 80 °C, respectively. The detection and quantification limits were 0.03 and 0.1 μg L−1, respectively. The recovery values were between 70.2 and 103.2% and the RSD was ≤15.7 (n = 3). The linear range was 0.1–10 μg L−1 with r ≥ 0.96 and the fiber-to-fiber reproducibility showed RSD ≤ 18.6% (n = 5). The efficiency of the cork fiber was compared with commercially available fibers and good results were achieved, demonstrating the applicability and great potential of cork as a coating for SPME.  相似文献   

17.
Mesoporous TiO2 nanoparticles were synthesized with the hydrothermal method and characterized by powder X-ray diffraction (PXRD) and transmission electron microscope (TEM). Then a superior solid-phase microextraction (SPME) fiber was fabricated by sequentially coating the stainless steel fiber with silicone sealant film and mesoporous TiO2 powder. The developed fiber possessed a homogeneous surface and a long life-span up to 100 times at direct immersing (DI) extraction mode. Under the optimized conditions, the extraction efficiencies of the self-made 17 μm TiO2 fiber for six organochlorine pesticides (OCPs) were higher than those of the two commercial fibers (65 μm PDMS/DVB and 85 μm PA fibers) which were much thicker than the former. As for analytical performance, low detection limits (0.08–0.60 ng L−1) and wide linearity (5–5000 ng L−1) were achieved under the optimal conditions. The repeatabilities (n = 5) for single fiber were between 2.8 and 12.3%, while the reproducibilities (n = 3) of fiber-to-fiber were in the range of 3.7–15.7%. The proposed fiber was successfully applied to the sensitive analysis of OCPs in real water samples and four of the six analytes were detected from the rainwater and the lake water samples.  相似文献   

18.
An improved multiple co-polymerization technique was developed to prepare a novel molecularly imprinted polymer (MIP)-coated solid-phase microextraction (SPME) fiber with propranolol as template. Investigation was performed for the characteristics and application of the fibers. The MIP coating was highly crosslinked and porous with the average thickness of only 25.0 μm. Consequently, the adsorption and desorption of β-blockers within the MIP coating could be achieved quickly. The specific selectivity was discovered with the MIP-coated fibers to propranolol and its structural analogues such as atenolol, pindolol, and alprenolol. In contrast, only non-specific adsorption could be shown with the non-imprinted polymer (NIP)-coated fibers, and the extraction efficiencies of propranolol and pindolol with the MIP-coated fibers were higher markedly than that with the commercial SPME fibers. A MIP-coated SPME coupled with high-performance liquid chromatography (HPLC) method for propranolol and pindolol determination was developed under the optimized extraction conditions. Linear ranges for propranolol and pindolol were 20–1000 μg L−1 and detection limits were 3.8 and 6.9 μg L−1, respectively. Propranolol and pindolol in the spiked human urine and plasma samples, extracted with organic solvent firstly, could be simultaneous monitored with satisfactory recoveries through this method.  相似文献   

19.
A new sol–gel hybrid coating, polydimethylsiloxane–2-hydroxymethyl-18-crown-6 (PDMS–2OHMe18C6) was prepared in-house for use in solid phase microextraction (SPME). The three compositions produced were assessed for its extraction efficiency towards three selected organophosphorus pesticides (OPPs) based on peak area extracted obtained from gas chromatography with electron capture detection. All three compositions showed superior extraction efficiencies compared to commercial 100 μm PDMS fiber. The composition showing best extraction performance was used to obtain optimized SPME conditions: 75 °C extraction temperature, 10 min extraction time, 120 rpm stirring rate, desorption time 5 min, desorption temperature 250 °C and 1.5% (w/v) of NaCl salt addition. The method detection limits (S/N = 3) of the OPPs with the new sol–gel hybrid material ranged from 4.5 to 4.8 ng g−1, which is well below the maximum residue limit set by Codex Alimentarius Commission and European Commission. Percentage recovery of OPPs from strawberry, green apple and grape samples with the new hybrid sol–gel SPME material ranged from 65 to 125% with good precision of the method (%RSD) ranging from 0.3 to 7.4%.  相似文献   

20.
A novel solid-phase microextraction (SPME) Pt fiber coated with single-walled carbon nanotubes (SWCNTs) was prepared by electrophoretic deposition (EPD) and applied to the determination of phenols in aqueous samples by direct immersion (DI)-SPME-HPLC-UV. The results revealed that EPD was a simple and reproducible technique for the preparation of SPME fibers coated with SWCNTs without the use of adhesive. The obtained SWCNT coating did not swell in organic solvents nor strip off from substrate, and possessed high mechanical strength due to the strong Van der Waals attractions between the surfaces of the SWCNTs. The prepared SPME fiber was conductive since both SWCNT coating and Pt wire were conductive. Using Pt wire as substrate, the fiber was unbreakable. Owing to the presence of oxygenated groups on SWCNTs and the high surface area of SWCNTs, the SWCNT fiber was similar to or superior to commercial PA fiber in extracting the studied phenols from aqueous sample. A durability of more than 80 analyses was achieved for one unique fiber. Under optimized conditions, the detection limits for the phenols varied between 0.9 and 3.8 ng/mL, the precisions were in the range of 0.7–3.2% (n = 3), and linear ranges were within 10 and 300 ng/mL. The method was successfully applied to the analysis of spiked seawater and tap water samples with the recoveries from 87.5 to 102.0%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号