首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Lab‐on‐a‐chip provides an ideal platform for short tandem repeat (STR) genotyping due to its intrinsic low sample consumption, rapid analysis, and high‐throughput capability. One of the challenges, however, in the forensic human identification on the microdevice is the detection sensitivity derived from the nanoliter volume sample handling. To overcome such a sensitivity issue, here we developed a sample stacking CE microdevice for mini Y STR genotyping. The mini Y STR includes redesigned primer sequences to generate smaller‐sized PCR amplicons to enhance the PCR efficiency and the success rate for a low copy number and degraded DNA. The mini Y STR amplicons occupied in the 5‐ and 10‐mm stacking microchannels are preconcentrated efficiently in a defined narrow region through the optimized sample stacking CE scheme, resulting in more than tenfold improved fluorescence peak intensities compared with that of a conventional cross‐injection microcapillary electrophoresis method. Such signal enhancement allows us to successfully analyze the Y STR typing with only 25 pg of male genomic DNA, with high background of female genomic DNA, and with highly degraded male genomic DNA. The combination of the mini Y STR system with the novel sample stacking CE microdevice provides the highly sensitive Y STR typing on a chip, making it promising to perform high‐performance on‐site forensic human identification.  相似文献   

2.
Simultaneous amplification of nine human short tandem repeat (STR) DNA sequences and the amelogenin locus allows reducing to an absolute minimum the amount of sample material that is necessary for genetic identification or kinship analysis. Valuable remains can be studied this way without any visible damage, as is demonstrated by typing the DNA of a tooth root from the Saxon warrior Widukind, who died about 1200 years ago. The broad applicability of the megaplex approach is shown by typing bone and teeth specimens ranging from a few months to 3000 years of age employing AmpFlSTR Profiler Plus. Additionally, megaplex STR typing is the method of choice for proving the authenticity of molecular results derived from ancient degraded DNA.  相似文献   

3.
DNA profiling of short tandem repeats (STR) has been successfully used for the identification of individuals in forensic samples, accidents and natural disasters. However, STR profiling of DNA isolated from old crime scenes and damaged biological samples is difficult due to DNA degradation and fragmentation. Here, we show that pre‐amplification of STR loci using biotinylated primers for the STR loci is an efficient strategy to obtain STR profiling results from fragmented forensic samples. Analysis of STR loci with longer amplicon sizes is generally hampered, since these relatively long loci are vulnerable to DNA fragmentation. This problem was overcome by using reduced or increased primer concentrations for loci with shorter or longer amplicon sizes, respectively, in our pre‐amplification strategy. In addition, pre‐amplification of STR loci into two groups of short or long amplicon size increases the efficiency of STR profiling from highly fragmented forensic DNA samples. Therefore, differential pre‐amplification of STR loci is an effective way to obtain DNA profiling results from fragmented forensic samples.  相似文献   

4.
DNA analysis of degraded samples and low-copy number DNA derived from skeletal remains, one of the most challenging forensic tasks, is common in disaster victim identification and genetic analysis of historical materials. Massively parallel sequencing (MPS) is a useful technique for STR analysis that enables the sequencing of smaller amplicons compared with conventional capillary electrophoresis (CE), which is valuable for the analysis of degraded DNA. In this study, 92 samples of human skeletal remains (70+ years postmortem) were tested using an in-house MPS-STR system designed for the analysis of degraded DNA. Multiple intrinsic factors of DNA from skeletal remains that affect STR typing were assessed. The recovery of STR alleles was influenced more by DNA input amount for amplification rather than DNA degradation, which may be attributed from the high quantity and quality of libraries prepared for MPS run. In addition, the higher success rate of STR typing was achieved using the MPS-STR system compared with a commercial CE-STR system by providing smaller sized fragments for amplification. The results can provide constructive information for the analysis of degraded sample, and this MPS-STR system will contribute in forensic application with regard to skeletal remain sample investigation.  相似文献   

5.
An electrochemical DNA genosensor constructed by using rough gold as electrode support is reported in this work. The electrode surface nanopatterning was accomplished by repetitive square-wave perturbing potential (RSWPP). A synthetic 25-mer DNA capture probe, modified at the 5′ end with a hexaalkylthiol, able to hybridize with a specific sequence of lacZ gene from the Enterobacteriaceae bacterial family was assembled to the rough gold surface. A 25 bases synthetic sequence fully complementary to the thiolated DNA capture probe and a 326 bases fragment of lacZ containing a fully matched sequence with the capture probe, which was amplified by a specific asymmetric polymerase chain reaction (aPCR), were employed as target sequences. The hybridization event was electrochemically monitored by using two different indicators, hexaammineruthenium (III) chloride showing an electrostatic DNA binding mode, and pentaamineruthenium-[3-(2-phenanthren-9-yl-vinyl)-pyridine] (in brief RuL) which binds to double stranded DNA (dsDNA) following an intercalative mechanism. After optimization of the different variables involved in the hybridization and detection reactions, detection limits of 5.30 pg μL−1 and 10 pg μL−1 were obtained for the 25-mer synthetic target DNA and the aPCR amplicon, respectively. A RSD value of 6% was obtained for measurements carried out with 3 different genosensors prepared in the same manner.  相似文献   

6.
Wang J  McCord B 《Electrophoresis》2011,32(13):1631-1638
A common problem in the analysis of forensic DNA evidence is the presence of environmentally degraded and inhibited DNA. Such samples produce a variety of interpretational problems such as allele imbalance, allele dropout and sequence specific inhibition. In an attempt to develop methods to enhance the recovery of this type of evidence, magnetic bead hybridization has been applied to extract and preconcentrate DNA sequences containing short tandem repeat (STR) alleles of interest. In this work, genomic DNA was fragmented by heating, and sequences associated with STR alleles were selectively hybridized to allele-specific biotinylated probes. Each particular biotinylated probe-DNA complex was bound to streptavidin-coated magnetic beads using enabling enrichment of target DNA sequences. Experiments conducted using degraded DNA samples, as well as samples containing a large concentration of inhibitory substances, showed good specificity and recovery of missing alleles. Based on the favorable results obtained with these specific probes, this method should prove useful as a tool to improve the recovery of alleles from degraded and inhibited DNA samples.  相似文献   

7.
Gradient elution isotachophoresis (GEITP) was demonstrated for DNA purification, concentration, and quantification from crude samples, represented here by soiled buccal swabs, with minimal sample preparation prior to human identification using STR analysis. During GEITP, an electric field applied across leading and trailing electrolyte solutions resulted in isotachophoretic focusing of DNA at the interface between these solutions, while a pressure‐driven counterflow controlled the movement of the interface from the sample reservoir into a microfluidic capillary. This counterflow also prevented particulates from fouling or clogging the capillary and reduced or eliminated contamination of the delivered DNA by PCR inhibitors. On‐line DNA quantification using laser‐induced fluorescence compared favorably with quantitative PCR measurements and potentially eliminates the need for quantitative PCR prior to STR analysis. GEITP promises to address the need for a rapid and robust method to deliver DNA from crude samples to aid the forensic community in human identification.  相似文献   

8.
In this report, Au-coated nanostructured biochip with functionalized thiolated primers on its surface is developed for label-free and real-time optical detection of polymerase chain reaction (PCR). A PCR chamber of 150 μm in thickness containing Au-coated nanostructured substrate in the bottom layer was bordered with SU-8 100 walls. After immobilization of 5′-thiolated primers on the surface, simultaneous DNA amplification and detection were performed without any labeled molecules via the relative reflected intensity (RRI) of Au-coated nanostructured substrate. When human genomic DNA at several concentrations of 0.2, 0.5 and 1 ng μL−1 was included in the initial DNA samples, the increases in the RRI peak values were clearly observed with the increasing PCR cycle numbers. We found that the starting point of the optical signal, which was divergent from the background in our PCR biochip, was around 3-4 cycles, much lower than that of the fluorescent real-time PCR analysis (around 23-25 cycles). Our proposed PCR device using Au-coated nanostructured substrate holds noteworthy promise for rapid, label-free and real-time DNA detection for point-of-care testing (POCT) applications.  相似文献   

9.
We have developed a novel STR 25‐plex florescence multiplex‐STR kit (DNATyper25) to genotype 23 autosomal and two sex‐linked loci for forensic applications and paternity analysis. Of the 23 autosomal loci, 20 are non‐CODIS. The sex‐linked markers include a Y‐STR locus (DYS391) and the Amelogenin gene. We present developmental validation studies to show that the DNATyper25 kit is reproducible, accurate, sensitive, and robust. Sensitivity testing showed that full profiles were achieved with as low as 125 pg of human DNA. Specificity testing demonstrated a lack of cross reactivity with a variety of commonly encountered non‐human DNA contaminants. Stability testing showed that full profiles were obtained with humic acid concentration ≤60 ng/μL and hematin concentration <400 μM. For forensic evaluation, the 23 autosomal STRs followed the Hardy–Weinberg equilibrium. In an analysis of 509 Chinese (CN) Hans, we detected a combined total of 181 alleles at the 23 autosomal STR loci. Since these autosomal STRs are independent from one another, PM was 8.4528 × 10?22, TDP was 0.999 999 999 999 999 999 999, CEP was 0.999 999 8395. The forensic efficiency parameters demonstrated that these autosomal STRs are highly polymorphic and informative in the Han population of China. We performed population comparisons and showed that the Northern CN Han has a close genetic relationship with the Luzhou Han, Tujia, and Bai populations. We propose that the DNATyper25 kit will be useful for cases where paternity analysis is difficult and for situations where DNA samples are limited in quantity and low in quality.  相似文献   

10.
A fully integrated microdevice and process for forensic short tandem repeat (STR) analysis has been developed that includes sequence-specific DNA template purification, polymerase chain reaction (PCR), post-PCR cleanup and inline injection, and capillary electrophoresis (CE). Fragmented genomic DNA is hybridized with biotin-labeled capture oligos and pumped through a fluidized bed of magnetically immobilized streptavidin-coated beads in microchannels where the target DNA is bound to the beads. The bead-DNA conjugates are then transferred into a 250 nL PCR reactor for autosomal STR amplification using one biotin and one fluorescence-labeled primer. The resulting biotin-labeled PCR products are electrophoretically injected through a streptavidin-modified capture gel where they are captured to form a concentrated and purified injection plug. The thermally released sample plug is injected into a 14 cm long CE column for fragment separation and detection. The DNA template capture efficiency provided by the on-chip sequence-specific template purification is determined to be 5.4% using K562 standard DNA. This system can produce full 9-plex STR profiles from 2.5 ng input standard DNA and obtain STR profiles from oral swabs in about 3 hours. This fully integrated microsystem with sample-in-answer-out capability is a significant advance in the development of rapid, sensitive, and reliable micro-total analysis systems for on-site human identification.  相似文献   

11.
The development and characterization of a magnetic bead (MB)-quantum dot (QD) nanoparticles based assay capable of quantifying pathogenic bacteria is presented here. The MB-QD assay operates by having a capturing probe DNA selectively linked to the signaling probe DNA via the target genomic DNA (gDNA) during DNA hybridization. The signaling probe DNA is labeled with fluorescent QD565 which serves as a reporter. The capturing probe DNA is conjugated simultaneously to a MB and another QD655, which serve as a carrier and an internal standard, respectively. Successfully captured target gDNA is separated using a magnetic field and is quantified via a spectrofluorometer. The use of QDs (i.e., QD565/QD655) as both a fluorescence label and an internal standard increased the sensitivity of the assay. The passivation effect and the molar ratio between QD and DNA were optimized. The MB-QD assay demonstrated a detection limit of 890 zeptomolar (i.e., 10−21 mol L−1) concentration for the linear single stranded DNA (ssDNA). It also demonstrated a detection limit of 87 gene copies for double stranded DNA (dsDNA) eaeA gene extracted from pure Escherichia coli (E. coli) O157:H7 culture. Its corresponding dynamic range, sensitivity, and selectivity were also presented. Finally, the bacterial gDNA of E. coli O157:H7 was used to highlight the MB-QD assay's ability to detect below the minimum infective dose (i.e., 100 organisms) of E. coli O157:H7 in water environment.  相似文献   

12.
《Electrophoresis》2017,38(6):846-854
This study assesses the performance of Illumina's MiSeq FGx System for forensic genomics by systematically analyzing single source samples, evaluating concordance, sensitivity and repeatability, as well as describing the quality of the reported outcomes. DNA from 16 individuals (9 males/7 females) in nine separate runs showed consistent STR profiles at DNA input ≥400 pg, and two full profiles were obtained with 50 pg DNA input. However, this study revealed that the outcome of a single sample does not merely depend on its DNA input but is also influenced by the total amount of DNA loaded onto the flow cell from all samples. Stutter and sequence or amplification errors can make the identification of true alleles difficult, particularly for heterozygous loci that show allele imbalance. Sequencing of 16 individuals’ STRs revealed genetic variations at 14 loci at frequencies suggesting improvement of mixture deconvolution. The STR loci D1S1656 and DXS10103 were most susceptible to drop outs, and D22S1045 and DYS385a‐b showed heterozygote imbalance.  Most stutters were typed at TH01 and DYS385a‐b, while amplification or sequencing errors were observed mostly at D7S820 and D19S433. Overall, Illumina's MiSeq FGx System produced reliable and repeatable results.  aSTRs showed fewer drop outs than the Y‐ and X‐STRs.  相似文献   

13.
14.
STR analysis is commonly used in forensic and genetic studies. STRs are currently discriminated based on size, primarily by gel- and column-based approaches. Hybridization-based approaches have the potential to allow high-throughput analysis of STRs; however, development of such approaches has been limited by the difficulty in discriminating between STRs of similar length. We have recently described several innovations to enable STR analysis using an array-based hybridization approach for high- throughput STR analysis. Here we extend that approach by incorporating the array into microspheres and adding a discriminatory branch migration displacement step. This microsphere-based platform uses Luminex xMAP technology and improves the sensitivity, selectivity, and speed of the assay. We demonstrate the feasibility, speed, and reliability of the assay for STR detection by correctly analyzing two STR loci in 20 forensic DNA samples of known STR type. The multiplex, bead-based approach provides a high-throughput and more portable STR analysis.  相似文献   

15.
The evaluation of a micro fluidic system with an integrated silica monolith for performing DNA extraction from limited biological samples has been carried out. Low DNA target concentrations usually require the addition of carrier RNA to ensure desired extraction efficiencies. Here, we demonstrate a micro fluidic extraction system with increasingly efficient extraction performances for biological samples containing <15 ng of total DNA without the need of adding carrier nucleic acids. All extracted DNA showed successful amplification via the polymerase chain reaction demonstrating both the effectiveness of the proposed system at removing potential inhibitors and yielding good quality DNA. The work presented here beneficially identifies reduced sample volumes/concentrations as suitable for processing with respect to downstream analysis by enabling pre-concentration of the biological sample, particularly important when dealing with clinical or forensic specimens.  相似文献   

16.
Whole-genome DNA amplification (WGA) is a promising method that generates large amounts of DNA from samples of limited quantity. We investigated the accuracy of a multiplex PCR approach to WGA over STR loci. The amplification bias within a locus and over all analyzed loci was investigated in relation to the amount of template in the WGA reaction, the specific STR locus, and allele length. We observed reproducible error-free STR profiles with 10 ng down to 1 ng of DNA template. The amplification deviation at a locus and between loci was within the intra-method reproducibility. WGA is the method of choice for amplifying nanogram amounts of genomic DNA for different applications. We detected unbalanced STR amplifications at one locus and between loci, allelic drop-outs, and additional alleles after WGA of low-copy-number DNA. We found that the high number of drop-outs and drop-ins could be eradicated using pooled DNA from separate WGA reactions even with as little as 100 pg of starting template. Nevertheless, the quality of the results was still not sufficient for use in routine chimerism analysis of limited specific cell populations after allogeneic stem cell transplantation.  相似文献   

17.
In this work, a new electrochemical biosensor for DNA detection of bacterial meningitis is proposed. The system is based on specific DNA fragments from the Neisseria meningitidis genome as a probe incorporated on graphite electrodes modified with poly(4-aminophenol). Detection of a complementary oligonucleotide sequence, a specific 710-base pair amplicon, and the genomic DNA of bacteria was carried out by differential pulse voltammetry, using ethidium bromide as an electroactive indicator of hybridization. The complementary oligonucleotide and the genomic DNA of Neisseria meningitidis were quantified by the genosensor, showing detection limits of 0.6 ng μL?1 and about 6 ng μL?1, respectively. Morphological differences were observed between hybridized and unhybridized surfaces by atomic force microscopy. The biosensor showed high selectivity, discriminating non-specific targets, and high stability retaining over 98% of its original activity after 120 days of storage. The bioelectrode was effective in discriminating the genomic DNA in samples with human serum without significant interference, proving to be an interesting platform for meningococcal meningitis diagnosis.  相似文献   

18.
There is growing interest in developing additional DNA typing techniques to provide better investigative leads in forensic analysis. These include inference of genetic ancestry and prediction of common physical characteristics of DNA donors. To date, forensic ancestry analysis has centered on population‐divergent SNPs but these binary loci cannot reliably detect DNA mixtures, common in forensic samples. Furthermore, STR genotypes, forming the principal DNA profiling system, are not routinely combined with forensic SNPs to strengthen frequency data available for ancestry inference. We report development of a 12‐STR multiplex composed of ancestry informative marker STRs (AIM‐STRs) selected from 434 tetranucleotide repeat loci. We adapted our online Bayesian classifier for AIM‐SNPs: Snipper, to handle multiallele STR data using frequency‐based training sets. We assessed the ability of the 12‐plex AIM‐STRs to differentiate CEPH Human Genome Diversity Panel populations, plus their informativeness combined with established forensic STRs and AIM‐SNPs. We found combining STRs and SNPs improves the success rate of ancestry assignments while providing a reliable mixture detection system lacking from SNP analysis alone. As the 12 STRs generally show a broad range of alleles in all populations, they provide highly informative supplementary STRs for extended relationship testing and identification of missing persons with incomplete reference pedigrees. Lastly, mixed marker approaches (combining STRs with binary loci) for simple ancestry inference tests beyond forensic analysis bring advantages and we discuss the genotyping options available.  相似文献   

19.
Semi‐nested PCR with allele‐specific (AS) primers and sequencing of mitochondrial DNA (mtDNA) were performed to analyze and interpret DNA mixtures, especially when biological materials were degraded or contained a limited amount of DNA. SNP‐STR markers were available to identify the minor DNA component using AS‐PCR; moreover, SNPs in mtDNA could be used when the degraded or limited amounts of DNA mixtures were not successful with SNP‐STR markers. Five pairs of allele‐specific primers were designed based on three SNPs (G15043A, T16362C, and T16519C). The sequence of mtDNA control region of minor components was obtained using AS‐PCR and sequencing. Sequences of the amplification fragments were aligned and compared with the sequences of known suspects or databases. When this assay was used with the T16362C and T16519C SNPs, we found it to be highly sensitive for detecting small amounts of DNA (~30 pg) and analyzing DNA mixtures of two contributors, even at an approximately 1‰ ratio of minor and major components. An exception was tests based on the SNP G15043A, which required approximately 300 pg of a 1% DNA mixture. In simulated three contributor DNA mixtures (at rate of 1:1:1), control region fragments from each contributor were detected and interpreted. AS‐PCR combined with semi‐nested PCR was successfully used to identify the mtDNA control region of each contributor, providing biological evidence for excluding suspects in forensic cases, especially when biological materials were degraded or had a limited amount of DNA.  相似文献   

20.
KONG  De-Ming SHEN  Han-Xi 《中国化学》2003,21(5):556-561
A new method based on the incorporation of a single-lablled probe-primer into polymerase chain reaction(PCR) for the detection of PCR-amplified DNA in a closed system is reported.The probeprimerc consists of a specific probe sequence on the 5‘‘‘‘‘‘‘‘-end and a primer sequence on the 3‘‘‘‘‘‘‘‘-end.A flurophore is located at the 5‘‘‘‘‘‘‘‘end.The primeR-quencher is an oligonucleotide,which is complementary to the probe sequence of probe-primer and labelled with a quencher at the 3‘‘‘‘‘‘‘‘-end.In the duplex formed by probe-primer and primer-quencher.the fluorophore and quencher are kept in close proximity to each other.Therefore the fluorescence is quenched.During PCR amplificatio,the specific probe sequence of probeprimer binds to its complement within the same strand of DNA,and is cleaved by Taq DNA polymerase,resulting in the restoration of fluorescence.This system has the same energy transfer mechanism as molecular beacons,and a good quenching effciency can be ensured.Following optimization of PCR conditions,this method was used to detect hepatitis b virus(HBV) dna in patient sera.This technology eliminates the risk of carry-over contamination,simplifies the amplification assay and opens up new possibilities for the real-time detection of the amplified DNA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏