首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The application of miniaturised separation techniques such as capillary LC, nano LC or capillary electrophoresis offers a number of advantages in terms of analytical performance, solvent consumption and the ability to analyse very small sample amounts. These features make them attractive for various bioanalytical tasks, in particular those related to the analysis of proteins and peptides. The skillful combination of such techniques with inductively coupled plasma mass spectrometry (ICP-MS) has recently permitted the design of combined analytical approaches utilising either elemental or molecule-specific detection techniques such as electrospray ionisation (ESI) or matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry in a highly complementary manner for, as an example, proteomics-orientated research (heteroatom-tagged proteomics). Such hybrid approaches are, in particular, providing promising new options for the fast screening of complex samples for specific metal-containing or—more generally speaking—heteroatom-containing biomolecules, as well as the accurate absolute quantification of biomolecules, which is still an unsolved problem in bioanalysis. Here, progress in as well as the potential and the special requirements of hyphenating miniaturised separation techniques with ICP-MS are reviewed and critically discussed. In addition, selected applications are highlighted to indicate current and possible future trends within this emerging area of research.  相似文献   

2.
Nowadays, the most common strategies used in quantitative proteomics are based on isotope-coded labeling followed by specific molecule mass spectrometry. The implementation of inductively coupled plasma mass spectrometry (ICP-MS) for quantitative purposes can solve important drawbacks such as lack of sensitivity, structure-dependent responses, or difficulties in absolute quantification. Recently, lanthanide-containing labels as metal-coded affinity tag (MeCAT) reagents have been introduced, increasing the interest and scope of elemental mass spectrometry techniques for quantitative proteomics. In this work one of the first methodologies for absolute quantification of peptides and proteins using MeCAT labeling is presented. Liquid chromatography (LC) interfaced to ICP-MS has been used to separate and quantify labeled peptides while LC coupled to electrospray ionization mass spectrometry served for identification tasks. Synthetic-labeled peptides were used as standards to calibrate the response of the detector with compounds as close as possible to the target species. External calibration was employed as a quantification technique. The first step to apply this approach was MeCAT-Eu labeling and quantification by isotope dilution ICP-MS of the selected peptides. The standards were mixed in different concentrations and subjected to reverse-phase chromatography before ICP-MS detection to consider the column effect over the peptides. Thus, the prepared multi-peptide mix allowed a calibration curve to be obtained in a single chromatographic run, correcting possible non-quantitative elutions of the peptides from the column. The quantification strategy was successfully applied to other labeled peptides and to standard proteins such as digested lysozyme and bovine serum albumin.  相似文献   

3.
Separation techniques coupled to inductively coupled plasma mass spectrometry (ICP-MS) is reviewed. ICP-MS technique is described briefly. Coupling of the different separation techniques are described, together with the most common applications used for each technique that has been described in the literature. An overview for the future of separation techniques coupled to ICP-MS with regard to elemental speciation is discussed.  相似文献   

4.
In recent years the number of environmental applications of elemental speciation analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. The analytical characteristics, such as extremely low detection limits (LOD) for almost all elements, the wide linear range, the possibility for multi-elemental analysis and the possibility to apply isotope dilution mass spectrometry (IDMS) make ICP-MS an attractive tool for elemental speciation analysis. Two methodological approaches, i.e. the combination of ICP-MS with high performance liquid chromatography (HPLC) and gas chromatography (GC), dominate the field. Besides the investigation of metals and metalloids and their species (e.g. Sn, Hg, As), representing “classic” elements in environmental science, more recently other elements (e.g. P, S, Br, I) amenable to ICP-MS determination were addressed. In addition, the introduction of isotope dilution analysis and the development of isotopically labeled species-specific standards have contributed to the success of ICP-MS in the field. The aim of this review is to summarize these developments and to highlight recent trends in the environmental application of ICP-MS coupled to GC and HPLC.  相似文献   

5.
Quantification of unknown components in pharmaceutical, metabolic and environmental samples is an important but difficult task. Most commonly used detectors (like UV, RI or MS) require standards of each analyte for accurate quantification. Even if the chemical structure or elemental composition is known, the response from these detectors is difficult to predict with any accuracy. In inductively coupled plasma mass spectrometry (ICP-MS) compounds are atomised and ionised irrespective of the chemical structure(s) incorporating the element of interest. Liquid chromatography coupled with inductively coupled plasma mass spectrometry (LC/ICP-MS) has been shown to provide a generic detection for structurally non-correlated compounds with common elements like phosphorus and iodine. Detection of selected elements gives a better quantification of tested 'unknowns' than UV and organic mass spectrometric detection. It was shown that the ultrasonic nebuliser did not introduce any measurable dead volume and preserves the separation efficiency of the system. ICP-MS can be used in combination with many different mobile phases ranging from 0-100% organic modifier. The dynamic range was found to exceed 2.5 orders of magnitude. The application of LC/ICP-MS to pharmaceutical drugs and formulations has shown that impurities can be quantified below the 0.1 mol-% level.  相似文献   

6.
Inorganic mass spectrometry techniques may offer great potential for the characterisation at the nanoscale, because they provide unique elemental information of great value for a better understanding of processes occurring at nanometre-length dimensions. Two main groups of techniques are reviewed: those allowing direct solid analysis with spatial resolution capabilities, i.e. lateral (imaging) and/or in-depth profile, and those for the analysis of liquids containing colloids. In this context, the present capabilities of widespread elemental mass spectrometry techniques such as laser ablation coupled with inductively coupled plasma mass spectrometry (ICP-MS), glow discharge mass spectrometry and secondary ion/neutral mass spectrometry are described and compared through selected examples from various scientific fields. On the other hand, approaches for the characterisation (i.e. size, composition, presence of impurities, etc.) of colloidal solutions containing nanoparticles by the well-established ICP-MS technique are described. In this latter case, the capabilities derived from the on-line coupling of separation techniques such as field-flow fractionation and liquid chromatography with ICP-MS are also assessed. Finally, appealing trends using ICP-MS for bioassays with biomolecules labelled with nanoparticles are delineated.   相似文献   

7.
Despite the large number of successful applications of laser ablation, elemental and isotopic fractionation coupled to inductively coupled plasma mass spectrometry (ICP-MS) remain as the main limitations for many applications of this technique in the fields of analytical chemistry and Earth Sciences. A substantial effort has been made to control such fractionations, which are well-established features of nanosecond laser ablation systems. Technological advancements made over the past decade now allow the ablation of solids by femtosecond laser pulses in the deep ultraviolet (UV) region at wavelengths less than 200 nm. Here the use of femtosecond laser ablation and its effects on elemental and isotopic fractionation is investigated. The Pb/U system is used to illustrate elemental fractionation and stable Fe isotopes are used to illustrate isotopic fractionation. No elemental fractionation is observed beyond the precision of the multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements. Without a matrix match between standard and sample, elemental fractionation is absent even when using different laser ablation protocols for standardization and samples (spot versus raster). Furthermore, we found that laser ablation-induced isotope ratio drifts, commonly observed during nanosecond laser ablation, are undetectable during ultraviolet femtosecond laser ablation. So far the precision obtained for Fe isotope ratio determinations is 0.1‰ (2 standard deviation) for the 56Fe/54Fe ratio. This is close to that obtainable by solution multiple-collector inductively coupled plasma mass spectrometry. The accuracy of the results appears to be independent of the matrix used for standardization. The resulting smaller particle sizes reduce fractionation processes. Femtosecond laser ablation carries the potential to solve some of the difficulties encountered during the two prior decades since the introduction of laser ablation.  相似文献   

8.
Liquid chromatography-inductively coupled plasma mass spectrometry.   总被引:3,自引:0,他引:3  
The technique of coupling liquid chromatography to inductively plasma mass spectrometry (ICP-MS) is reviewed. A brief introduction to the ICP-MS instrument is given as well as methods to couple the two analytical instruments together. The various types of LC that have been used with ICP-MS detection are discussed and advantages over traditional methods of detection are highlighted, such as the improvements in sensitivity and selectivity. Several applications that have been described in the literature are reviewed. An outlook for the future of LC-ICP-MS, particularly with regard to elemental speciation is given.  相似文献   

9.
This critical review focuses on inductively coupled plasma mass spectrometry (ICP-MS) based applications for isotope abundance ratio measurements in various clinical samples relevant to monitoring occupational or environmental exposure, human provenancing and reconstruction of migration pathways as well as metabolic research. It starts with a brief overview of recent advances in ICP-MS instrumentation, followed by selected examples that cover the fields of accurate analyte quantification using isotope dilution, tracer studies in nutrition and toxicology, and areas relying upon natural or man-made variations in isotope abundance ratios (Pb, Sr, actinides and stable heavy elements). Finally, some suggestions on future developments in the field are provided.  相似文献   

10.
The use of inductively coupled plasma mass spectrometry (ICP-MS) coupled with separation techniques for the purpose of elemental speciation has recently gained a lot of attention. Much of this is due to ever improving separation capabilities of Chromatographic techniques, the high sensitivity of ICP-MS, and the continuing development of better interface techniques. Additionally, there is a growing awareness of the need to monitor various species of an analyte, rather than just total analyte concentrations, due to their often varying natures. For the sake of learning from different elemental speciation approaches, this review brings together some selected types of elemental speciation which have been recently seen in literature. These include separations using various forms of liquid chromatography, such as reversed phase, reversed phase ion pairing, micelle, ion exchange, and size exclusion. Elemental speciation employing gas Chromatographie separations and supercritical fluid separations are discussed as well as elemental speciation using capillary electrophoresis.  相似文献   

11.
This year inductively coupled plasma mass spectrometry (ICP-MS) moves into the fourth decade of development. In this article, some recent trends and developments in ICP-MS are reviewed, with special focus on instrumental development and emerging applications. Some key trends include a novel mass spectrometer for elemental and speciation analysis in Mattauch–Herzog geometry with a focal-plane-camera array detector. The reason for this development is the possibility to record the full elemental mass range simultaneously and all the time. Monitoring fast transient signals in chromatography or laser ablation is now possible and will become an important asset in future studies, e.g., for isotope ratio analysis. In addition, there is a lot of new activity and interest in the area of nanosciences and medicine. Here, instrumental developments are reported that allow the direct analysis of microparticles and single cells.  相似文献   

12.
New developments in inductively coupled plasma mass spectrometry (ICP-MS) and laser desorption-time-of-flight mass spectrometry (LD-TOF-MS) for inorganic analysis are described. These include fundamental studies of the ion extraction, process in ICP-MS, development of a highly efficient nebulizer, isotope tracer studies, measurement of elemental speciation by liquid chromatography with ICP-MS detection and characterization of the structures of solids by ion association. The possibilities of determining inorganic species in solutions by electrospray MS are also described.  相似文献   

13.
电感耦合等离子体质谱(ICP-MS)及其联用技术研究进展   总被引:5,自引:0,他引:5  
综述了电感耦合等离子体质谱(ICP-MS)及其联用技术的研究进展,详细阐述了:1)各种色谱与ICP-MS的接口研究;2)MS技术的改进及信息处理研究,如采用碰撞池技术,高分辨等离子体质谱仪、多接收高分辨等离子体质谱仪和飞行时间质谱仪等;3)进样技术和联用技术,如激光烧蚀、微波消解、冷蒸发进样等技术的进展。讨论了电感耦合等离子体质谱及联用技术的发展趋势,并对目前存在的主要问题及可能的解决方案进行了讨论。  相似文献   

14.
离子色谱技术的重要进展和我国近年的发展概况   总被引:1,自引:0,他引:1  
赵新颖  屈锋  牟世芬 《色谱》2017,35(3):223-228
介绍了离子色谱技术近年的几项重要进展,包括Reagent-Free离子色谱系统,简易阀切换技术,弱电离有机酸的高灵敏分析,快速分析色谱柱,与前处理技术、电感耦合等离子体质谱和氢化物发生-原子荧光光谱联用,在生物医药分析中的应用等;并概述了近年来我国离子色谱在硬件技术研发、仪器检定规范的修改、标准方法和药典修订等方面的进展。  相似文献   

15.
综述了电感耦合等离子体质谱(ICP-MS)及其联用分析技术的进展,论述了其在相关核工业及环境领域中分析痕量或超痕量的放射性同位素、长寿命核素、元素形态等的应用。讨论了电感耦合等离子体质谱及联用技术的发展趋势,并对目前存在的主要问题及可能的解决方案进行了讨论。  相似文献   

16.
From human health exposure related to environmental contamination to ancient deep-Earth processes related to differentiation of the Earth’s geochemical reservoirs, the adaptability of inductively coupled plasma mass spectrometry (ICP-MS) has proven to be an indispensable standard technique that transcends disciplines. Continued advancements in ICP-MS, including improved auxiliary applications such as laser ablation (LA), ion/liquid chromatography (IC), automated pre-concentration systems (e.g., seaFAST), and improved desolvating nebulizer systems (e.g., Aridus and Apex) have revolutionized our ability to analyze almost any sample matrix with remarkable precision at exceedingly low elemental abundances. The versatility in ICP-MS applications allows for effective interdisciplinary crossover, opening a world of analytical possibilities. In this communication, we discuss the adaptability of geochemical techniques, including sample preparation and analysis, to environmental and biological systems, using Pb isotopes for source apportionment as a primary example.  相似文献   

17.
Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g−1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of high-purity materials and environmental samples) is used in order to improve the detection limits of trace elements. Furthermore, the determination of chemical elements in the trace and ultratrace concentration range is often difficult and can be disturbed through mass interferences of analyte ions by molecular ions at the same nominal mass. By applying double-focusing sector field mass spectrometry at the required mass resolution—by the mass spectrometric separation of molecular ions from the analyte ions—it is often possible to overcome these interference problems. Commercial instrumental equipment, the capability (detection limits, accuracy, precision) and the analytical application fields of mass spectrometric methods for the determination of trace and ultratrace elements and for surface analysis are discussed.  相似文献   

18.
Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with chromatographic separation techniques and laser ablation for the isotopic analysis of irradiated nuclear fuels. The advantages and limitations of the selected analytical technique for the characterization of such a heterogeneous sample matrix are discussed.  相似文献   

19.
The multianalyte immunoassay approach is currently attracting increasing attention due to its high sample throughput, short assay time, low sample consumption and reduced overall cost per assay. This paper reviews progress in the field of multianalyte immunoassays using inductively coupled plasma mass spectrometry, as well as applications of this approach in different fields. Examples related to the combination of protein microarray technology with the multitag approach of the immunoassay ICP-MS method and to the use of ICP-MS in the field of imaging are described. A novel strategy that involves tagging antibodies for ICP-MS detection in sensitive multitag bioassays is also presented. Finally, the outlook for this promising technique is discussed.  相似文献   

20.
This work represents a first systematic approach to the size-based elemental quantification and size estimation of metal(loid) oxide nanoparticles such as silica (SiO2) in a real food matrix using asymmetric flow field-flow fractionation coupled online with inductively coupled plasma mass spectrometry (ICP-MS) and multi-angle light scattering (MALS) and offline with transmission electron microscopy (TEM) with energy-dispersive X-ray analysis (EDAX). Coffee creamer was selected as the model sample since it is known to contain silica as well as metal oxides such as titania at the milligramme per kilogramme levels. Optimisation of sample preparation conditions such as matrix-to-solvent ratio, defatting with organic solvents and sonication time that may affect nanoparticle size and size distribution in suspensions was investigated. Special attention was paid to the selection of conditions that minimise particle transformation during sample preparation and analysis. The coffee creamer matrix components were found to stabilise food grade SiO2 particles in comparison with water suspensions whilst no significant effect of defatting using hexane was found. The use of sample preparation procedures that mimic food cooking in real life was also investigated regarding their effect on particle size and particle size distribution of silica nanoparticles in the investigated food matrix; no significant effect of the water temperature ranging from ambient temperature to 60 °C was observed. Field-flow fractionation coupled to inductively coupled plasma-mass spectrometry (FFF-ICP-MS) analysis of extracts of both unspiked coffee creamer and coffee creamer spiked with food grade silicon dioxide, using different approaches for size estimation, enabled determination of SiO2 size-based speciation. Element-specific detection by ICP-MS and post-FFF calibration with elemental calibration standards was used to determine the elemental composition of size fractions separated online by FFF. Quantitative data on mass balance is provided for the size-based speciation of the investigated inorganic nano-objects in the complex matrix. The combination of FFF with offline fractionation by filtration and with detection by ICP-MS and TEM/EDAX has been proven essential to provide reliable information of nanoparticle size in the complex food matrix.
Figure
Characterisation of silica nanoparticles in a coffee creamer matrix using FFF-based methodology  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号