首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Song-Min Huo  An-Ping Deng 《Talanta》2007,73(2):380-386
The development and validation of a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of pharmaceutical indomethacin in water samples was presented. The immunogen and coating antigen were prepared by covalently linking indomethacin to bovine serum albumin and ovalbumin by anhydride ester method. Two rabbits were immunized by standard immunization processes and the superior antibody was characterized in terms of sensitivity, specificity, precision, accuracy and stability. Under optimal experimental conditions, the standard curve was constructed in the concentration range of 0.01-10 ng/mL. For 10 consecutive standard curves run in 2 weeks, IC50 value (the concentration of analyte producing 50% of inhibition) were found within 0.10-0.25 ng/mL, and the detection limit (DL) at a signal-to-noise ratio of 3 (S/N = 3) was about 0.01 ng/mL. The antiserum recognized acemetacin, a precursor of indomethacin with 92.3% cross-reactivity, while the cross-reactivity values of antiserum with other tested compounds were very low. From the spiking experiments, the recoveries were found within 98-123%. The ELISA was applied for the determination of indomethacin in different water samples and the results were confirmed by conventional HPLC. The correlation coefficient of 0.988 was obtained, demonstrating a good correlation of ELISA with HPLC.  相似文献   

2.
Microcystins (MC) are cyanobacterial hepatotoxins responsible for animal-poisoning and human health incidents. Immunoassays provide a sensitive and fast means to detect these toxins, but cross-reactivity (CR) characteristic of different antibodies was variable. Here, we have produced and characterized a monoclonal antibody (Clone MC8C10) with highly specificity against the most frequent and most toxic variant of microcystins, MC-LR. MC8C10 is more specific against MC-LR among the reported antibodies before. The immunogen was synthesized from the modified MC-LR and bovine serum albumin (BSA). An indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) with MC8C10 was established to detect the MCs in waters, which showed highly specificity with MC-LR, and have a detection limit for MC-LR 0.1 μg L−1, the 50% inhibition concentration (IC50) for MC-LR was 1.8 ± 0.1 μg L−1 and the quantitative detection range was from 0.3 to 10 μg L−1. The [4-arginine] microcystins and the nodularin-R showed lower cross-reactivates (CR < 10%), and other MCs such as MC-LF and MC-LW are not recognized (CR < 10−4). The analysis results of real water samples with ic-ELISA showed that all the coefficients of variation were less than 15%, and the recovery was (100.3 ± 5.9)%. So the highly specific ic-ELISA will commendably suit for sensitive analysis for MC-LR in surface water as well as drinking water.  相似文献   

3.
The use of olaquindox (OLA) as an additive in animal feedstuffs has been prohibited in the European Union and many other countries. In this study, a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for determination of OLA in animal feed samples was developed. OLA was activated by NN-carbonyldiimidazole and coupled with bovine serum albumin (BSA) and ovalbumin (OVA). It was found that the sensitivity and specificity of the two antisera were very similar, with the IC50 values of 16 ng mL−1 and 19 ng mL−1, respectively. Cross-reactivity was less than 35% for four structurally related compounds and no recognition of five other antibiotics was observed. The better antiserum I was selected for further experiments, for example testing stability, solvent effect, accuracy, and precision. The IC50 value for eight standard curves was in the range 12–18 ng mL−1 and the LOD at a signal-to-noise ratio of 3 (S/N = 3) was 0.31 ± 0.11 ng mL−1. The ELISA tolerated 5% methanol without significant influence on IC50 value. The recoveries of spiked OLA in five different animal feed types including auxin, pig complex feed, fish complex feed, broiler concentrated feed, and pig premix feed were in the range 88.3–119.0% and the intra-assay relative standard deviation (RSD) was within 4.7–33.5% (n = 3). The ELISA for unspiked feed samples was confirmed by high-performance liquid chromatography (HPLC), with a high correlation coefficient of 0.9862 (n = 5). The proposed ELISA could be a feasible quantitative/screening method for OLA analysis in feed samples with the properties of high sensitivity, specificity, simplicity of sample pretreatment, high sample throughput, and low expense. Figure Polyclonal antibody based ELISA for detection of olaquindox  相似文献   

4.
Sensitive detection of tetrabromobisphenol A (TBBPA) and its derivatives, a group of emerging toxic contaminants, is highly necessitated in environmental investigation. Herein a novel analytical strategy based on reactive extractive electrospray ionization (EESI) tandem mass spectrometry for detection of tetrabromobisphenol A bis(2-hydroxyethyl ether) (TBBPA-BHEE), tetrabromobisphenol A bis(glycidyl ether) (TBBPA-BGE), tetrabromobisphenol A bis(allylether) (TBBPA-BAE), and tetrabromobisphenol S bis(allylether) (TBBPS-BAE) in industrial waste water samples was developed. Active silver cations (Ag+), generated by electrospraying a silver nitrate methanol solution (10 mg L−1), collides the neutral TBBPA derivatives molecules in the EESI source to form [M + Ag]+ complexes of the analytes under the ambient conditions. Upon collision-induced dissociation (CID), characteristic fragments of the [M + Ag]+ complexes were identified for confident and sensitive detection of the four TBBPA derivatives. Under the optimized experimental conditions, the instrumental limits of detection (LODs) of TBBPA-BHEE, TBBPA-BGE, TBBPA-BAE and TBBPS-BAE were 0.37, 0.050, 0.76, and 4.6 μg L−1, respectively. The linear ranges extended to 1000 μg L−1 (R2 ≥ 0.9919), and the relative standard deviations (RSDs), inter-day variation and intra-day variation were less than 7.8% (n = 9), 10.0% (n = 5), and 14.8% (n = 1 per day for 5 days) for all derivatives. TBBPA derivative manufacturing industrial waste water, river water and tap water samples were fast analyzed with the proposed method. The contents of TBBPA derivatives were various in the collected samples, with the highest 19.9 ± 0.3 μg L−1 of TBBPA-BAE in the waste water samples.  相似文献   

5.
Polycyclic aromatic hydrocarbons (PAHs) are frequently encountered in the environment and may pose health concerns due to their carcinogenicity. A commercial enzyme-linked immunosorbent assay (ELISA), was evaluated as a screening method for monitoring PAHs at contaminated sites. The ELISA was a carcinogenic PAH (C-PAH) RaPID assay testing kit that cross-reacts with several PAHs and utilizes benzo[a]pyrene (BaP) as a calibrator. Soil samples were extracted with 50% acetone in dichloromethane (DCM) for analysis by ELISA and gas chromatography-mass spectrometry (GC-MS). The overall method precision was within ±30% for ELISA and within ±20% for GC-MS. Recovery data for spiked soils ranged from 46 to 140% for BaP as determined by ELISA. Recoveries data of the GC-MS surrogate standards, 2-fluorobiphenyl and chrysene, were greater than 70%. The GC-MS procedure detected a total of 19 priority PAHs (2-6-ring PAHs) including seven probable human carcinogens (4-6-ring B2-PAHs). The ELISA results were compared to GC-MS summation results for the total 19 target PAHs as well as for the subset of the seven B2-PAH compounds. For all soil samples, the PAH concentrations derived from ELISA were greater than the sum of B2-PAH concentrations obtained by GC-MS. ELISA determinations were also frequently greater than the results obtained by GC-MS for the total 19 PAH compounds. This discrepancy can be expected, since the ELISA is a screening assay for the detection of several related PAHs while the GC-MS procedure detects priority PAH compounds. Thus, only a subset of PAHs (e.g. 19 PAHs) in the soil samples were measured by GC-MS while additional PAHs, including alkylated PAHs, and PAH derivatives have been demonstrated to be cross-reactive in the C-PAH ELISA. Results of paired tests show that the PAH data from ELISA and GC-MS methods are significantly different (P<0.001), but highly correlated. The ELISA data had a strong positive relationship with the GC-MS summation data for the B2-PAHs as well as for the 19 PAHs targeted by the GC-MS method. Results indicate that the ELISA may be useful as a broad screen for monitoring PAHs in environmental samples.  相似文献   

6.
Zhao H  Nan T  Tan G  Gao W  Cao Z  Sun S  Li Z  Li QX  Wang B 《Analytica chimica acta》2011,(1):102-108
Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)–ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)–EDTA–BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)–EDTA–BSA–horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator–protein complexes such as EDTA–BSA and EDTA–BSA–HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules.  相似文献   

7.
Microcystins (MCs) are a group of closely related toxic cyclic heptapeptides produced by common cyanobacteria (blue-green algae), and microcystin-leucine-arginine (MC-LR) is among the most frequent and most toxic microcystin congeners. In this study, a free amino group was introduced to MC-LR at its seventh amino acid residue with 2-mercaptoethylamine, and the product aminoethyl-MC-LR was coupled to bovine serum albumin (BSA) and horseradish peroxidise (HRP) by glutaraldehyde to be complete antigen (MC-LR-BSA) and labelled hapten (MC-LR-HRP), respectively. Polyclonal antibodies against MC-LR were generated by immunization with MC-LR-BSA. A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was established to detect the MCs in waters, which showed a good cross-reactivity with MC-LR, MC-RR, MC-YR, MC-LF, MC-LW and nodularin, and have a detection limit for MC-LR 0.12 μg L−1, the 50% inhibition concentration (IC50) for MC-LR was 0.63 ± 0.06 μg L−1 and the quantitative detection range was from 0.17 to 2.32 μg L−1, the analysis result of water samples showed good recovery and reliability. So the comprehensive and reliable dc-ELISA will well potentially suit for sensitive analysis for total MCs in drinking as well as resource water samples.  相似文献   

8.
In this work, a novel monoclonal antibody specific for naringin was prepared and characterized. Subsequently, an indirect competitive enzyme‐linked immunosorbent assay for naringin was developed, with an effective range from 4.8 to 156 ng/mL naringin. Next, an immunoaffinity column was obtained by coupling anti‐naringin monoclonal antibodies to CNBr‐activated Sepharose 4B and a rapid immunoaffinity chromatography assay for naringin was developed. The immunoaffinity column was used to separate naringin from Citrus aurantium. The results showed that 1 g of the dry Sepharose 4B can couple 10 mg of immunoglobulin G. And the immunoaffinity column can efficiently and specifically capture approximately 250 μg of naringin without cross reacting with its structurally similar compounds. Moreover, our results indicate that the application of immunoaffinity chromatography can simplify the pretreatment and the isolation process greatly compared to conventional methods, providing a potential method for extracting the target component from structurally similar compounds in natural products.  相似文献   

9.
Semicarbazide (SEM), the marker residue for the banned nitrofuran veterinary antibiotic nitrofurazone (NFZ), has been detected regularly in foods (47% of recent nitrofuran EU Rapid Alerts involve SEM). However, the validity of SEM as a definitive marker for NFZ has been undermined by SEM arising from other sources including azodicarbonamide, a plastics blowing agent and flour treatment additive. An inexpensive screening test for SEM in food matrices is needed—all SEM testing currently uses expensive LC-MS/MS instrumentation. We now report the first production of antibodies against derivatised SEM. A novel carboxyphenyl SEM derivative was used to raise a polyclonal antibody that has been incorporated into a semi-quantitative microtitre plate ELISA, validated according to the criteria set out in Commission Decision 2002/657/EC, for use with chicken muscle. The antibody is highly specific for derivatised SEM, cross-reactivity being 1.7% with NFZ and negligible with a wide range of other nitrofurans and poultry drugs. Samples are derivatised with o-nitrobenzaldehyde and simultaneously protease digested before extraction by cation exchange SPE. The ELISA has a SEM detection capability (CCβ) of 0.25 μg kg−1 when a threshold of 0.21 μg kg−1 is applied to the selection of samples for confirmation (lowest observed 0.25 μg kg−1 fortified sample, n = 20), thus satisfying the EU nitrofurans’ minimum required performance limit of 1 μg kg−1. NFZ-incurred muscles (12) containing SEM at 0.5-5.0 μg kg−1 by LC-MS/MS, all screened positive by this ELISA protocol which is also applicable to egg and chicken liver.  相似文献   

10.
Liang Y  Liu XJ  Liu Y  Yu XY  Fan MT 《Analytica chimica acta》2008,615(2):174-183
A general and broad class-specific enzyme-linked immunosorbent assay was developed for the O,O-dimethyl organophosphorus pesticides, including malathion, dimethoate, phenthoate, phosmet, methidathion, fenitrothion, methyl parathion and fenthion. Three haptens with different spacer-arms were synthesized. The haptens were conjugated to bovine serum albumin (BSA) for immunogens and to ovalbumin (OVA) for coating antigens. Rabbits were immunized with the immunogens and six polyclonal antisera were produced and screened against each of the coating antigens using competitive indirect enzyme-linked immunosorbent assay for selecting the proper antiserum. The effect of hapten heterology on immunoassay sensitivity was also studied. The antibody-antigen combination with the most selectivity for malathion was further optimized and tested for tolerance to co-solvent, pH and ionic strength changes. The IC50 values, under optimum conditions, were estimated to be 30.1 μg L−1for malathion, 28.9 μg L−1 for dimethoate, 88.3 μg L−1 for phenthoate, 159.7 μg L−1 for phosmet, 191.7 μg L−1 for methidathion, 324.0 μg L−1 for fenitrothion, 483.9 μg L−1 for methyl parathion, and 788.9 μg L−1 for fenthion. Recoveries of malathion, dimethoate, phenthoate, phosmet and methidathion from fortified Chinese cabbage samples ranged between 77.1% and 104.7%. This assay can be used in monitoring studies for the multi-residue determination of O,O-dimethyl organophosphorus pesticides.  相似文献   

11.
Four haptens of the organophosphorus (OP) insecticide diazinon were synthesized to develop enzyme-linked immunosorbent assays (ELISAs) for this pesticide. One of them was conjugated to KLH to be used as the immunogen for production of monoclonal antibodies. By using the antibodies and a coating antigen, an indirect competitive ELISA was developed, which showed an IC50 of 4.0 ng/mL with a detection limit of 0.7 ng/mL. A direct competitive ELISA using an enzyme tracer was also developed, which showed an IC50 of 6.0 ng/mL with a detection limit of 0.9 ng/mL. The antibodies in both assays showed negligible cross-reactivity with metabolites of diazinon and other OP pesticides. Recovery of diazinon from fortified lettuce and rice samples was satisfactory except at the fortified concentration of 100 ppb.  相似文献   

12.
Using bamboo‐activated charcoal as SPE adsorbent, a novel SPE method was developed for the sensitive determination of tetrabromobisphenol A and bisphenol A in environmental water samples by rapid‐resolution LC‐ESI‐MS/MS. Important parameters influencing extraction efficiency, including type of eluent, eluent volume, sample pH, volume and flow rate, were investigated and optimized. Under the optimal extraction conditions (eluent: 8 mL methanol, pH: 7; flow rate: 4 mL/min; sample volume: 100 mL), low LODs (0.01–0.02 ng/mL), good repeatability (6.2–8.3%) and wide linearity range (0.10–10 ng/mL) were obtained. Satisfied results were achieved when the proposed method was applied to determine the two target compounds in real‐world environmental water samples with spiked recoveries over the range of 80.5–119.8%. All these facts indicate that trace determination of tetrabromobisphenol A and bisphenol A in real‐world environmental water samples can be realized by bamboo‐activated charcoal SPE‐rapid resolution‐LC‐ESI‐MS/MS.  相似文献   

13.
A green enzyme-linked immunosorbent assay (ELISA) to measure aflatoxin M1 (AFM1) in milk was developed and validated with a surrogate calibrator curve. Polyclonal anti-idiotype (anti-Id) antibody, used as an AFM1 surrogate, was generated by immunizing rabbits with F(ab′)2 fragments from the anti-AFM1 monoclonal antibody (mAb). The rabbits exhibited high specificity to the anti-AFM1 mAb, and no cross-reactivity to either of the other anti-aflatoxin mAbs or the isotype matched mAb was observed. After optimizing the physicochemical factors (pH and ionic strength) that influence assay performance, a quantitative conversion formula was developed between AFM1 and the anti-Id antibody (y = 31.91x − 8.47, r = 0.9997). The assay was applied to analyze AFM1 in spiked milk samples. The IC50 value of the surrogate calibrator curve was 2.4 μg mL−1, and the inter-assay and intra-assay variations were less than 10.8%; recovery ranged from 85.2 to 110.9%. A reference high-performance liquid chromatography method was used to validate the developed method, and a good correlation was obtained (y = 0.81x + 9.82, r = 0.9922).  相似文献   

14.
Triazines have been used widely as herbicides and known to cause environmental contamination. For developing ELISA of s-triazines, six kinds of s-triazine derivatives (one from simazine, one from atrazine and four from cyanuric chloride) which contained a C3- or C6-carboxylic acid group bridge were prepared. These derivatives were conjugated to bovine serum albumin (BSA) for the use of immunogens and to KLH for the use of coating ligands on the microtiter plate wells. Polyclonal antibodies produced from rabbit or sheep using atrazine-BSA (1b-BSA) and simazine-BSA (1a-BSA) immunogens. These antibodies were characterized and biotinylated for the use of enzyme immunoassay (EIA). We evaluated EIA and biotin-streptavidin mediated EIA in terms of the sensitivities and specificities with these antibodies. The results in both assay systems showed that coating ligand synthesized from atrazine derivative was better than that from simazine derivative. Comparing binding ability between C3-carboxylic acid and C6-carboxylic acid spacers of N-alkyl group in s-triazine ring, C3-carboxylate-KLH (2c-KLH) derived from atrazine showed better sensitivity for the both assay systems. The detection limit was found to be 0.01 ppb in biotin-streptavidin mediated EIA (B-Av EIA). Comparing IC90 values of EIA (0.5 ppb) and B-Av EIA (0.05 ppb), B-Av EIA was able to detect one order lower concentration range of atrazine than EIA.  相似文献   

15.
以驴抗鼠二抗包被微孔板,以捕获方式包被抗赭曲霉毒素A(OTA)单克隆抗体,利用噬菌体随机七肽库筛选OTA模拟抗原表位,并以其替代检测抗原,建立了基于噬菌体展示技术的酶联免疫吸附分析(Phage ELISA)检测OTA的方法.结果表明,筛选获得的模拟OTA抗原表位七肽氨基酸序列为GMSWMMA.基于模拟表位噬菌体建立的Phage ELISA方法半数抑制浓度(IC50值)为(0.15±0.02) ng/mL,检测OTA的线性范围为0.03~ 0.50 ng/mL,OTA的检出限为0.03 ng/mL,且Phage ELISA与其它4种常见真菌毒素(黄曲霉毒素B1、伏马毒素B1、脱氧雪腐镰刀菌烯醇及玉米赤霉烯酮)无交叉反应.大米样品OTA加标实验表明,批内加标回收率为97.0% ~ 115.2%,批间加标回收率为107.2% ~ 123.1%,与ELISA试剂盒检测结果比较,无显著性差异.  相似文献   

16.
A rabbit antibody immunoaffinity (IA) column procedure was evaluated as a cleanup method for the determination of atrazine in soil, sediment, and food. Four IA columns were prepared by immobilizing a polyclonal rabbit anti-atrazine antibody solution to HiTrap Sepharose columns. Atrazine was bound to the IA columns when the loading solvents were either 100% water, 2% acetonitrile in water, or 10% methanol in phosphate buffered saline (PBS). Quantitative removal of atrazine from the IA columns was achieved with elution solvents of either 70% ethanol in water, 70% methanol in water, or 100% methanol. One control column was prepared using nonspecific rabbit IgG antibody. This control column did not retain any applied atrazine indicating atrazine did not bind indiscriminately to protein or the Sepharose support. The four IA columns showed reproducible coupling efficiency for the immobilization of the atrazine antibody and consistent binding and releasing of atrazine. The coupling efficiency (4.25 mg of antibody in 1 mL of resin bed) for the four IA columns ranged from 93 to 97% with an average of 96 ± 2% (2.1%). Recoveries of the 500, 50, and 5 ng mL−1 atrazine standard solutions from the four IA columns were 107 ± 7% (6.5%), 122 ± 14% (12%), and 114 ± 9% (8.0%) respectively, based on enzyme-linked immunosorbent assay (ELISA) data. The maximum loading was approximately 700 ng of atrazine for each IA column (∼0.16 μg of atrazine per mg of antibody). The IA columns could withstand 100% methanol as the elution solvent and could be reused more than 50 times with no change in performance. The IA columns were challenged with soil, sediment, and duplicate-diet food samples and effectively removed interferences from these various matrices for subsequent gas chromatography/mass spectrometry (GC/MS) or ELISA analysis. The log-transformed ELISA and GC/MS data were significantly correlated for soil, sediment and food samples although the ELISA values were slightly higher than those obtained by GC/MS. The IA column cleanup procedure coupled with ELISA analysis could be used as an alternative effective analytical method for the determination of atrazine in complex sample media such as soil, sediment, and food samples.  相似文献   

17.
Vardenafil is a phosphodiesterase-5 (PDE-5) inhibitor for the treatment of erectile dysfunction (ED). Undeclared vardenafil and related analogues adulterated in herbal products are a threat to public health. To screen vardenafil and its analogues in herbal matrix rapidly, an immunoassay based on a group specific monoclonal antibody (McAb) was developed.Glutaraldehyde was used to link vardenafil to immunogen and coating-antigen, respectively. Through the assessment of the structural specificity of eight anti-vardenafil McAbs, the McAb of 4B9 was characterized as being specific to the common structure of vardenafil and its analogues. An indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was established based on this McAb, the limit of detection of vardenafil was 5.0 ng mL−1, the calibration curve was linear from 5.0 to 40 ng mL−1 (R2 = 0.952) with an IC50 value of 18.2 ng mL−1. In the extracts of 20 Chinese traditional drugs, the detection capability (CCβ) of vardenafil was 0.08 mg g−1, the recoveries were 76-116% and the coefficients of variation (CV%) were 9.7%-16.2%. The ic-ELISA was in good agreement with LC-UV when detected herbal products containing vardenafil and its analogue.The method is a suitable tool for screening vardenafil and its analogues as illegal additives in herbal products.  相似文献   

18.
Graphene nanosheets (GS) were prepared via solvent exfoliation, and then hybridized with dioctadecyldimethylammonium bromide (DDAB). On the single surface of DDAB and GS film, the direct oxidation activities of tetrabromobisphenol A (TBBPA) are improved effectively, and consequently the oxidation signals enhance obviously. Interestingly, the composite of DDAB and GS exhibits remarkable synergetic effects toward the oxidation of TBBPA, and the peak currents of TBBPA further increase greatly on the DDAB-GS composite film. The signal enhancement mechanism was studied using chronocoulometry. It is found that the greatly-increased accumulation efficiency is the main reason. As a result, a novel electrochemical sensing platform was developed for TBBPA. The linear range is from 0.1 to 400 μg L−1, and the detection limit is as low as 41.8 ng L−1 (76.8 pM). The practical applications in water samples manifest that this new determination system is accurate and feasible.  相似文献   

19.
A novel procedure for parathion hapten design is described. The optimal antigen for parathion was selected after molecular modeling studies of six types of potentially immunizing haptens with the aim to identify the best mimicking target analyte. Heterologous competitive indirect enzyme-linked immunosorbent assay (ELISA) was developed after screening a battery of competitors as coating antigens. The relationship between the heterology degree of the competitor and the resulting immunoassay detectability was investigated according to the electronic similarities of the competitor haptens and the target analyte. Molecular modeling and principal component analysis were performed to understand the electronic distribution and steric parameters of the haptens at their minimum energetic levels. The results suggested that the competitors should have a high heterology to produce assays with good detectability values. An indirect competitive ELISA was finally selected for further investigation. The immunoassay had an IC50 value of 4.79 ng mL−1 and a limit of detection of 0.31 ng mL−1. There was little or no cross-reactivity to similar compounds tested except for the insecticide parathion-methyl, which showed a cross-reactivity of 7.8%.  相似文献   

20.
A europium nanoparticle-based lateral flow immunoassay for highly sensitive detection of chloramphenicol residue was developed. The detection result could be either qualitatively resolved with naked eye or quantitatively analyzed with the assistance of a digital camera. In the qualitative mode, the limit of detection (LOD) was found to be 0.25 ng/mL. In the quantitative mode, the half-maximal inhibition concentration (IC50) was determined to be 0.45 ng/mL and the LOD can reach an ultralow level of 0.03 ng/mL, which is ~100 times lower than that of the conventional colloidal gold-based lateral flow immunoassay. Potential application of the established method was demonstrated by analyzing representative cow milk samples.
Figure
A europium nanoparticle-based lateral flow immunoassay for highly sensitive detection of chloramphenicol (CAP) residue was developed, of which limit of detections (LODs) can reach low levels of 0.25 and 0.03 ng/mL, respectively, in the qualitative and quantitative modes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号