首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Perkins等[1]用MALDI/TOF/MS对不同种类蛇毒中神经毒素进行了分析,彭嘉柔等[2,3]对江浙蝮蛇和蛇毒粗组份进行了初步质谱表征.但蛇毒蛋白纯化困难,因此对单一组份的研究较少且不系统.本文以白眉蝮蛇蛇毒(AgkistrodonblomhoffiiUssurensis,ABUV)为原料,纯化得到了精氨酸酯酶(Arginineesterase,AEase)、磷脂酶A2(PhospholipaseA2,PLA2)、纤溶酶(fibrinolyticenzyme)和L-氨基酸氧化酶(L-aminoacidoxidase),并且用MALDI/TOF/MS法对它们和蛇毒粗毒进行了系统研究.1 实验部分1.1 仪器和药品 激光解吸质谱仪为美国Molecular公司L…  相似文献   

2.
The need of quick diagnostics and increasing number of bacterial species isolated necessitate development of a rapid and effective phenotypic identification method. Mass spectrometry (MS) profiling of whole cell proteins has potential to satisfy the requirements. The genus Mycobacterium contains more than 154 species that are taxonomically very close and require use of multiple genes including 16S rDNA for phylogenetic identification and classification. Six strains of five Mycobacterium species were selected as model bacteria in the present study because of their 16S rDNA similarity (98.4–99.8%) and the high similarity of the concatenated 16S rDNA, rpoB and hsp65 gene sequences (95.9–99.9%), requiring high identification resolution. The classification of the six strains by MALDI TOF MS protein barcodes was consistent with, but at much higher resolution than, that of the multi-locus sequence analysis of using 16S rDNA, rpoB and hsp65. The species were well differentiated using MALDI TOF MS and MALDI BioTyper™ software after quick preparation of whole-cell proteins. Several proteins were selected as diagnostic markers for species confirmation. An integration of MALDI TOF MS, MALDI BioTyper™ software and diagnostic protein fragments provides a robust phenotypic approach for bacterial identification and classification.  相似文献   

3.
The use of isobaric tagging for relative and absolute quantification (iTRAQ) has increased dramatically over the past few years. Many factors can affect the accuracy of quantification. Some of these include the number of biological/technical replicates, sample complexity, instrumentation, method of peptide/protein identification and the statistical techniques used for data analysis. It has been observed that the low collision energies normally used in electrospray ionization quadrupole time-of-flight (ESI QTOF) can result in low iTRAQ reporter ion abundances. We used two-way analysis of variance (ANOVA) to compare the iTRAQ ratios that were generated on an ESI QTOF and a matrix-assisted laser desorption/ionization tandem time-of-flight (MALDI TOF/TOF). It appears that iTRAQ analyses performed on an ESI QTOF without any special modifications to instrumental parameters produce essentially the same protein ratios as those obtained on a MALDI TOF/TOF.  相似文献   

4.
Gel-based matrix-assisted laser desorption ionization-time of flight tandem mass spectrometer (MALDI TOF/TOF MS) is one of the dominant methods of current proteomics, utilizing both peptide mass fingerprinting (PMF) and peptide fragment fingerprinting (PFF) for protein identification on a spot-to-spot basis. However, the unique impact of the quality of the corresponding mass spectrometry spectra remains largely unreported, and has motivated the development and use of an automatic spectra-assessment method. In this study, a multi-variant regression approach has been utilized to assess spectral quality for both PMF and PFF spectra obtained from MALDI TOF/TOF MS. The assessment index has been applied to investigations of MASCOT search results. Systematic examination of two large-scale sets of human liver tissue data has proved that spectral quality was a key factor in significant matching. Based on large-scale investigations on individual PMF search, individual PFF search and their combination, respectively, the filtering of bad quality spectra or spots proves to be an efficient way to improve search efficiency of all search modes in MASCOT. Meanwhile, a validation method based on score differences between normal and decoy (reverse or random) database searches is proposed to precisely define the positive matches. Further analysis showed that spectral quality assessment was also efficient in representing the quality of 2-DE gel spots and promoted the discovery of potential post-translation modifications.  相似文献   

5.
The quantity and variable quality of data that can be generated from liquid chromatography (LC)/mass spectrometry (MS)-based proteomics analyses creates many challenges in interpreting the spectra in terms of the actual proteins in a complex sample. In spite of improvements in algorithms that match putative peptide sequences to MS/MS spectra, the assembly of these lists of possible or probable peptides into a 'correct' set of proteins is still problematic. We have observed a trend in a simple relationship, derived from standard database search outputs, which can be useful in assessing the quality of a MS/MS-based protein identification. Specifically, the ratio of the protein score and number of non-redundant peptides, or average peptide score (APS), can facilitate initial filtering of database search results in addition to providing a useful measure of confidence for the proteins identified. This parameter has been applied to results from the analysis of multi-protein complexes derived from pull-down experiments analyzed using a two-dimensional LC/MS/MS workflow. In particular, the complex list of protein identifications derived from a drug affinity pull-down with immobilized ampicillin and an E. coli lysate was greatly simplified by applying the APS as a filter, allowing for facile identification of the penicillin-binding proteins known to interact with ampicillin. Furthermore, an APS threshold can be used for any data sets derived from electrospray ionization (ESI)- or matrix-assisted laser desorption/ionization (MALDI)-MS/MS experiments and is also not specific to any database search program.  相似文献   

6.
Matrix‐assisted laser desorption/ionisation–time of flight (MALDI‐TOF) mass spectrometry is commonly used for the identification of proteinaceous binders and their mixtures in artworks. The determination of protein binders is based on a comparison between the m/z values of tryptic peptides in the unknown sample and a reference one (egg, casein, animal glues etc.), but this method has greater potential to study changes due to ageing and the influence of organic/inorganic components on protein identification. However, it is necessary to then carry out statistical evaluation on the obtained data. Before now, it has been complicated to routinely convert the mass spectrometric data into a statistical programme, to extract and match the appropriate peaks. Only several ‘homemade’ computer programmes without user‐friendly interfaces are available for these purposes. In this paper, we would like to present our completely new, publically available, non‐commercial software, ms‐alone and multiMS‐toolbox, for principal component analyses of MALDI‐TOF MS data for R software, and their application to the study of the influence of heterogeneous matrices (organic lakes) for protein identification. Using this new software, we determined the main factors that influence the protein analyses of artificially aged model mixtures of organic lakes and fish glue, prepared according to historical recipes that were used for book illumination, using MALDI‐TOF peptide mass mapping. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
A study has been undertaken to evaluate the usefulness of MALDI Q-TOF data for protein identification. The comparison of MS data of protein digests obtained on a conventional MALDI TOF instrument to the MS data from the MALDI Q-TOF reveal peptide patterns with similar intensity ratios. However, comparison of MS/MS Q-TOF data produced by nanoelectrospray versus MALDI reveals striking differences. Peptide fragment ions obtained from doubly charged precursors produced by nanoelectrospray are mainly y-type ions with some b-ions in the lower mass range. In contrast, peptide fragment ions produced from the singly charged ions originating from the MALDI source are a mixture of y-, b- and a-ions accompanied by ions resulting from neutral loss of ammonia or water. The ratio and intensity of these fragment ions is found to be strongly sequence dependent for MALDI generated ions. The singly charged peptides generated by MALDI show a preferential cleavage of the C-terminal bond of acidic residues aspartic and glutamic acid and the N-terminal bond of proline. This preferential cleavage can be explained by the mobile proton model and is present in peptides that contain both arginine and an acidic amino acid. The MALDI Q-TOF MS/MS data of 24 out of 26 proteolytic peptides produced by trypsin or Asp-N digestions were successfully used for protein identification via database searching, thus indicating the general usefulness of the data for protein identification. De novo sequencing using a mixture of 160/18O water during digestion has been explored and de novo sequences for a number of peptides have been obtained.  相似文献   

8.
A novel MALDI LIFT-TOF/TOF mass spectrometer for proteomics   总被引:7,自引:0,他引:7  
A new matrix-assisted laser-desorption/ionization time-of-flight/time-of-flight mass spectrometer with the novel "LIFT" technique (MALDI LIFT-TOF/TOF MS) is described. This instrument provides high sensitivity (attomole range) for peptide mass fingerprints (PMF). It is also possible to analyze fragment ions generated by any one of three different modes of dissociation: laser-induced dissociation (LID) and high-energy collision-induced dissociation (CID) as real MS/MS techniques and in-source decay in the reflector mode of the mass analyzer (reISD) as a pseudo-MS/MS technique. Fully automated operation including spot picking from 2D gels, in-gel digestion, sample preparation on MALDI plates with hydrophilic/hydrophobic spot profiles and spectrum acquisition/processing lead to an identification rate of 66% after the PMF was obtained. The workflow control software subsequently triggered automated acquisition of multiple MS/MS spectra. This information, combined with the PMF increased the identification rate to 77%, thus providing data that allowed protein modifications and sequence errors in the protein sequence database to be detected. The quality of the MS/MS data allowed for automated de novo sequencing and protein identification based on homology searching.  相似文献   

9.
Electrospray mass spectrometry (ES/MS) and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI/TOF/MS) were used to provide mass spectra from seven elapid snake venoms. Spectral interpretation was much simpler for MALDI/TOF/MS. ES/MS proved more useful for the provision of molecular weight data for very closely related peptides, but suppression of higher molecular weight compounds was seen to occur during flow injection analysis. MALDI/TOF/MS proved useful for providing a complete picture of the venom, but the low resolution led to obscuring of major ions, and the mass accuracy was poorer for known peptides. Suppression also occurred during MALDI/TOF/MS but could be overcome using alternative matrices because the spectra were very dependent on the choice of matrix. ES/MS and MALDI/TOF/MS provide complementary and confirmatory information such that for the anal sis of complex peptide mixtures (snake venoms), the use of both techniques is desirable.  相似文献   

10.
Glutathione peroxidase (isolated from bovine erythrocytes) and its behaviour during alkylation and enzymatic digestion were studied by various hyphenated techniques: gel electrophoresis–laser ablation (LA) inductively coupled plasma (ICP) mass spectrometry (MS), size-exclusion liquid chromatography–ICP MS, capillary high-performance liquid chromatography (capHPLC)–ICP MS, matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) MS, electrospray MS, and nanoHPLC–electrospray ionization (ESI) MS/MS. ESI TOF MS and MALDI TOF MS allowed the determination of the molecular mass but could not confirm the presence of selenium in the protein. The purity of the protein with respect to selenium species could be evaluated by LA ICP MS and size-exclusion chromatography (SEC)–ICP MS under denaturating and nondenaturating conditions, respectively. SEC–ICP MS and capHPLC–ICP MS turned out to be valuable techniques to study the enzymolysis efficiency, miscleavage and artefact formation during derivatization and tryptic digestion. For the first time the parallel ICP MS and ESI MS/MS data are reported for the selenocysteine-containing peptide extracted from the gel; capHPLC–ICP MS allowed the sensitive detection of the selenopeptide regardless of the matrix and nanoHPLC–electrospray made possible its identification. Figure Eye catching image Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

11.
Current biological studies have been advanced by the continuous development of robust, accurate, and sensitive mass spectrometric technologies. The MALDI LTQ Orbitrap is a new addition to the Orbitrap configurations, known for their high resolving power and accuracy. This configuration provides features inherent to the MALDI source, such as reduced spectra complexity, forgiveness to contaminants, and sample retention for follow-up analyses with targeted or hypothesis-driven questions. Here we investigate its performance for characterizing the composition of isolated protein complexes. To facilitate the assessment, we selected two well characterized complexes from Saccharomyces cerevisiae, Apl1 and Nup84. Manual and automatic MS and MS/MS analyses readily resolved their compositions, with increased confidence of protein identification compared with our previous reports using MALDI QqTOF and MALDI IT. CID fragmentation of singly-charged peptides provided sufficient information for conclusive identification of the isolated proteins. We then assessed the resolution, accuracy, and sensitivity provided by this instrument in the context of analyzing the isolated protein assemblies. Our analysis of complex mixtures of singly-charged ions up to m/z 4000 showed that (1) the resolving power, inversely proportional to the square root of m/z, had over four orders of magnitude dynamic range; (2) internal calibration led to improved accuracy, with an average absolute mass error of 0. 5 ppm and a distribution centered at 0 ppm; and (3) subfemtomole sensitivity was achieved using both CHCA and DHB matrices. Additionally, our analyses of a synthetic phosphorylated peptide in mixtures showed subfemtomole level of detection using neutral loss scanning.  相似文献   

12.
A strategy for the characterization of bacterial lipoprotein-in this case Braun’s lipoprotein (an outer membrane 7-ku lipoprotein) isolated from Escherichia coli—is described by time-of-flight mass spectrometric (TOF/MS) techniques [252Cf plasma desorption (PD) TOF/MS and matrix-assisted laser desorption-ionization (MALDI) TOF/MS]. Covalent linkage of lipid at the N-terminal cysteine (posttranslationally modified to a S-[2,3-bis(acyloxy)-propyl]-N-acylcysteine) and, therefore, strict insolubility in aqueous solution constitute common features for this class of proteins. Relative molecular mass determination of the major molecular species of Braun’s lipoprotein was obtained by selection of an appropriate mixture of organic solvents compatible with matrix/support materials useful for the mass spectrometric techniques applied. Minor components of this lipoprotein that differ only in the fatty acid composition of the lipid anchor were detected by PD TOF/MS after enzymatic release of the extremely hydrophobic N-terminal amino acid followed by selective extraction with chloroform. Part of the primary sequence of this lipoprotein was confirmed based on peptide fragment ions observed in the positive ion PD mass spectra of cyanogen bromide-generated peptide fragments that had been isolated previously by reverse phase high-performance liquid chromatography (HPLC). Peptidoglycan fragments that represent the attachment sites of lipoprotein to peptidoglycan were enzymatically released, separated by reverse phase HPLC, and finally characterized by time-of-flight mass spectrometric techniques (252Cf-PD TOF/MS, MALDI TOF/MS). The results obtained with both techniques differed only in the better sensitivity obtained with MALDI TOF/MS, which consumed a factor of 100 to 1000 less material than with PD TOF/MS.  相似文献   

13.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF MS) has been proved to be a powerful tool for the identification and characterization of microorganisms based on their surface peptide/protein pattern. Because of the complexity of microorganisms, there are no standardized protocols to acquire reproducible peptide/protein profiles for a broad range of microorganisms and for fungi in particular. Small variations during MALDI MS sample preparation affect the quality of mass spectra quite often. In this study, we were aiming to develop a sample preparation method for the analysis of colored, a quite often observed phenomenon, and mycotoxin-producing Fusarium conidia spores using MALDI–TOF MS. Different washing solvent systems for light- and deep-colored (from slightly orange to red-brown) conidia spores and connected sample deposition techniques were evaluated based on MS reproducibility and number and intensities of peaks. As a method of choice for generation of reproducible and characteristic MALDI–TOF mass spectra, the use of a washing process for colored Fusarium conidia spores with acetonitrile/0.5% formic acid (7/3) was found and subsequently combined with two-layer volume technique (spores/matrix (ferulic acid) solution was deposited onto a MALDI target, and after solvent evaporation, a second matrix layer was deposited). With the application of this sample preparation method, for deep-colored Fusarium species, 19 abundant molecular ions in the m/z range 2,000–10,000 were always detected with an S/N ratio of 3:1 or better. Finally this optimized sample preparation for the first time provided mass spectrometric fingerprints of strongly colored Fusarium conidia spores resulting in the possibility of differentiation of such spores at the species level.   相似文献   

14.
The high accuracy, molecular resolution and sensitivity of matrix‐assisted laser desorption/ionisation time‐of‐flight mass spectrometry (MALDI‐TOF‐MS) make it an efficient method for analysing all kinds of biomolecules including nucleic acids, proteins/peptides, carbohydrates and lipids. MALDI‐TOF‐MS based high‐throughput genotyping of genetic heterogeneities possesses the potential of becoming a routine method. MAL‐DI‐TOF‐MS can be used for the identification of proteins and posttranslational modifications. Taken together, MALDI‐TOF‐MS represents a integrated platform technology in bioanalytics and molecular medicine.  相似文献   

15.
A novel method for separating ions according to their charge state using a quadrupole time-of-flight mass spectrometer is presented. The benefits of charge state separation are particularly apparent in protein identification applications at low femtomole concentration levels, where in conventional TOF MS spectra peptide ions are often lost in a sea of chemical noise. When doubly and triply charged tryptic peptide ions need to be filtered from singly charged background ions, the latter are suppressed by two to three orders of magnitude, while from 10-50% of multiply charged ions remain. The suppression of chemical noise reduces the need for chromatography and can make this experimental approach the electrospray equivalent of conventional MALDI peptide maps. If unambiguous identification cannot be achieved, MS/MS experiments are performed on the precursor ions identified through charge separation, while the previously described Q2-trapping duty cycle enhancement is tuned for approximately 1.4 of the precursor m/z to enhance intensities of ions with m/z values above that of the precursor. The resulting product ion spectra contain few fragments of impurities and provide quick and unambiguous identification through database search. The multiple charge separation technique requires minimal tuning and may become a useful tool for analysis of complex mixtures.  相似文献   

16.
Mass spectrometry imaging (MSI) provides the ability to detect and identify a broad range of analytes and their spatial distributions from a variety of sample types, including tissue sections. Here we describe an approach for probing neuropeptides from sparse cell cultures using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MSI—at single cell spatial resolution—in both MS and tandem MS modes. Cultures of Aplysia californica neurons are grown on an array of glass beads embedded in a stretchable layer of Parafilm M. As the membrane is stretched, the beads/neurons are separated physically and the separated beads/neurons analyzed via MALDI TOF MS. Compared with direct MS imaging of samples, the stretching procedure enhances analyte extraction and incorporation into the MALDI matrix, with negligible analyte spread between separated beads. MALDI tandem MSI using the stretched imaging approach yields localization maps of both parent and fragment ions from Aplysia pedal peptide, thereby confirming peptide identification. This methodology represents a flexible platform for MSI investigation of a variety of cell cultures, including functioning neuronal networks.  相似文献   

17.
Yang Y  Thannhauser TW  Li L  Zhang S 《Electrophoresis》2007,28(12):2080-2094
With 2-D gel mapping, it is often observed that essentially identical proteins migrate to different positions in the gel, while some seemingly well-resolved protein spots consist of multiple proteins. These observations can undermine the validity of gel-based comparative proteomic studies. Through a comparison of protein identifications using direct MALDI-TOF/TOF and LC-ESI-MS/MS analyses of 2-D gel separated proteins from cauliflower florets, we have developed an integrated approach to improve the accuracy and reliability of comparative 2-D electrophoresis. From 46 spots of interest, we identified 51 proteins by MALDI-TOF/TOF analysis and 108 proteins by LC-ESI-MS/MS. The results indicate that 75% of the analyzed spots contained multiple proteins. A comparison of hit rank for protein identifications showed that 37 out of 43 spots identified by MALDI matched the top-ranked hit from the ESI-MS/MS. By using the exponentially modified protein abundance index (emPAI) to determine the abundance of the individual component proteins for the spots containing multiple proteins, we found that the top-hit proteins from 40 out of 43 spots identified by MALDI matched the most abundant proteins determined by LC-MS/MS. Furthermore, our 2-D-GeLC-MS/MS results show that the top-hit proteins in 44 identified spots contributed on average 81% of the spots' staining intensity. This is the first quantitative measurement of the average rate of false assignment for direct MALDI analysis of 2-D gel spots using a new integrated workflow (2-D gel imaging, "2-D GeLC-MS/MS", and emPAI analysis). Here, the new approach is proposed as an alternative to traditional gel-based quantitative proteomics studies.  相似文献   

18.
A procedure for identification of malting barley varieties using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) of ethanol‐soluble barley proteins (hordeins) is described. The hordeins were first extracted from milled barley grains by several extraction protocols (using different extraction agents and conditions). Hordein extracts were then analyzed directly via MALDI‐TOF MS without any preliminary purification or separation step, and the protein profiles of analyzed hordein extracts were compared in order to find out the most suitable extraction procedure for mass spectrometric analysis. The optimized procedure was successfully applied to identification of 13 malting barley varieties. Our results revealed that the proposed mass spectrometry‐based approach provides characteristic mass patterns of extracted hordeins, which can be advantageously used for barley variety identification. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
Owing to its broad biological significance, the large-scale analysis of protein phosphorylation is more and more getting into the focus of proteomic research. Thousands of phosphopeptides can nowadays be identified using state-of-the-art tandem mass spectrometers in conjunction with sequence database searching, but localizing the phosphate group to a particular amino acid in the peptide sequence is often still difficult. Using 180 individually synthesized phosphopeptides with precisely known phosphorylation sites (p-sites), we have assessed the merits of the Mascot Delta Score (MD score) for the assignment of phosphorylation sites from tandem mass spectra (MS/MS) generated on four different matrix-assisted laser desorption ionization (MALDI) mass spectrometers including tandem time-of-flight (TOF/TOF), quadrupole time-of-flight, and ion trap mass analyzers. The results show that phosphorylation site identification is generally possible with false localization rates of about 10%. However, a comparison to previous work also revealed that phosphorylation site determination by MALDI MS/MS is less accurate than by ESI-MS/MS particularly if several and/or adjacent possible phosphorylation acceptor sites exist in a peptide sequence. We are making the tandem MS spectra and phosphopeptide collection available to the community so that scientists may adapt the MD scores reported here to their analytical environment and so that informatics developers may integrate the MD score into proteomic data analysis pipelines.  相似文献   

20.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) is a valuable tool for rapid bacterial detection and identification but is limited by the need for relatively high cell count samples, which have been grown under strictly controlled conditions. These requirements can be eliminated by the natural infection of a viable bacterial species of interest with a host‐specific phage. This produces a rapid increase in phage protein concentrations in comparison to bacterial concentrations, which can in turn be exploited as a method for signal amplification during MALDI‐TOF MS. One drawback to this approach is the requirement for repetitive, time‐consuming sample preparation and analysis applied over the course of a phage infection to monitor phage concentrations as a function of time to determine the MALDI‐TOF MS detection limit. To reduce the requirement for repeated preparation and analysis, a modified phage therapy model was investigated as a means for predicting the time during a given phage infection when a detectable signal would occur. The modified model used a series of three differential equations composed of predetermined experimental parameters including phage burst size and burst time to predict progeny phage concentrations as a function of time. Using Yersinia pestis with plague diagnostic phage ?A1122 and Escherichia coli with phage MS2 as two separate, well‐characterized model phage–host pairs, we conducted in silico modeling of the infection process and compared it with experimental infections monitored in real time by MALDI‐TOF MS. Significant agreement between mathematically calculated phage growth curves and those experimentally obtained by MALDI‐TOF MS was observed, thus verifying this method's utility for significant time and labor reduction. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号