首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Katsumata H  Fujii A  Kaneco S  Suzuki T  Ohta K 《Talanta》2005,65(1):129-134
A sensitive and selective batch adsorption method is proposed for the preconcentration and determination of simazine. Simazine was preconcentrated on diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 μg of simazine and 5 mL of ethanol as an eluent. Recovery of simazine was 89.0 ± 1.6% with a relative standard deviation for seven determinations of 1.5% under optimum conditions. The maximum preconcentration factor was 100 for simazine when 500 mL of sample solution volume was used. The linear range of calibration curve was 1-200 ng mL−1 with a correlation coefficient of 0.996 and the detection limit (3S/N) was 0.3 ng mL−1. The capacity of the adsorbent was also examined and found to be 1.1 mg g−1 for simazine. The proposed method was successfully applied to the determination of simazine in river water with high precision and accuracy.  相似文献   

2.
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of atrazine and simazine. Atrazine and simazine were preconcentrated on heat-treated diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recoveries of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 μg of triazines and 5 mL of ethanol as an eluent. Recoveries of atrazine and simazine were 95.7 ± 4.2% and 75.0 ± 1.9% with a relative standard deviation for seven determinations of 4.7% and 2.7% under optimum conditions. The maximum preconcentration factor was 100 for triazines when 500 mL of sample solution volume was used. The linear ranges of calibration curves for atrazine and simazine were 1-150 ng mL−1 and 1-300 ng mL−1, respectively, with correlation coefficients of 0.999 and the detection limits (3Signal-to-Noise) were 0.24 ng mL−1 and 0.21 ng mL−1 for atrazine and simazine. The capacity of the adsorbent was also examined and found to be 0.8 mg g−1 and 1.3 mg g−1 for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of triazines in river water and tap water samples with high precision and accuracy.  相似文献   

3.
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of diazinon. Diazinon was preconcentrated on multiwalled carbon nanotubes (MWCNTs) as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 6 using 200 mL of validation solution containing 2 μg of diazinon and 5 mL of acetonitrile as an eluent. Recovery of diazinon was 95.2 ± 4.2% with a relative standard deviation for seven determinations of 4.9% under optimum conditions. The maximum preconcentration factor was 200 for diazinon when 1000 mL of sample solution volume was used. The linear range of calibration curve was 0.3 to 10,000 ng mL− 1 with a correlation coefficient of 0.997 and the detection limit (3S/N) was 0.06 ng mL− 1. The proposed method was successfully applied to the determination of diazinon in tap water with high precision and accuracy.  相似文献   

4.
A new system for on-line preconcentration of molybdenum by sorption on a minicolumn associated to inductively coupled plasma — optical emission spectrometry with ultrasonic nebulization was studied. It is based on the sorption of molybdenum on a column packed with immobilized baker's yeasts on controlled pore glass without further complexing reagent. The molybdenum preconcentrated by biosorption was subsequently eluted with hydrochloric acid. Considering a sample flow rate of 5.0 mL min− 1, 10 mL of sample was preconcentrated in 2 min achieving a sensitive total enhancement factor of 480-fold, and the detection limit (3 s) obtained was 21 ng L− 1. Additionally, the calculated precisions expressed as percent relative standard deviation (RSD%) was 1.9%.Satisfactory results were obtained for the determination of molybdenum in standard reference material NIST 1643e Trace Elements in Water and real water samples.  相似文献   

5.
Arpa Şahin C  Durukan I 《Talanta》2011,85(1):657-661
In this article, a new ligandless solidified floating organic drop microextraction (LL-SFODME) method has been developed for preconcentration of trace amount of cadmium as a prior step to its determination by flow injection-flame atomic absorption spectrometry (FI-FAAS). The methodology is based on the SFODME of cadmium with 1-dodecanol in the absence of chelating agent. Several factors affecting the microextraction efficiency, such as, pH, sodium dodecylbenzenesulfonate (SDBS) concentration, extraction time, stirring rate and temperature were investigated and optimized. Under optimized experimental conditions an enhancement factor of 205 was obtained for 100 mL of sample solution. The calibration graph was linear in the range of 1.0-25.0 ng mL−1, the limit of detection (3s) was 0.21 ng mL−1 and the limit of quantification (10s) was 0.62 ng mL−1. The relative standard deviation (RSD) for 10 replicate measurements of 10 ng mL−1 cadmium was 4.7%. The developed method was successfully applied to the extraction and determination of cadmium in standard and several water samples and satisfactory results were obtained.  相似文献   

6.
Zhang Y  Adeloju SB 《Talanta》2008,76(4):724-730
A simple and robust flow injection system which permits low sample and reagent consumption is described for rapid and reliable hydride generation atomic absorption spectrometric determination of selenium, arsenic and bismuth. The system, which composed of one peristaltic pump and one four channel solenoid valve, used water as the carrier streams for both sample and NaBH4 solution. Rapid off-line pre-reduction of the analytes was achieved by using hydroxylamine hydrochloride for selenium and a mixture of potassium iodide and ascorbic acid for arsenic and bismuth. Transition metal interference was eliminated with the addition of thiourea and EDTA into the NaBH4 solution and significant sensitivity enhancement was observed for selenium in the presence of thiourea in the reductant solution. Under optimised conditions, the method achieved detection limits of 0.2 ng mL−1 for Se, 0.5 ng mL−1 for As and 0.3 ng mL−1 for Bi. The method was very reproducible, achieving relative standard deviations of 6.3% for Se, 3.6% for As and 4.7% for Bi, and has a sample throughput of 360 h−1. Successful application of the method to the quantification of selenium, arsenic and bismuth in a certified reference river sediment sample is reported.  相似文献   

7.
In pH 6.6 Britton–Robinson buffer medium, the CdS quantum dots capped by thioglycolic acid could react with aminoglycoside (AGs) antibiotics such as neomycin sulfate (NEO) and streptomycin sulfate (STP) to form the large aggregates by virtue of electrostatic attraction and the hydrophobic force, which resulted in a great enhancement of resonance Rayleigh scattering (RRS) and resonance non-linear scattering such as second-order scattering (SOS) and frequency doubling scattering (FDS). The maximum scattering peak was located at 310 nm for RRS, 568 nm for SOS and 390 nm for FDS, respectively. The enhancements of scattering intensity (ΔI) were directly proportional to the concentration of AGs in a certain ranges. A new method for the determination of trace NEO and STP using CdS quantum dots probe was developed. The detection limits (3σ) were 1.7 ng mL−1 (NEO) and 4.4 ng mL−1 (STP) by RRS method, were 5.2 ng mL−1 (NEO) and 20.9 ng mL−1 (STP) by SOS method and were 4.4 ng mL−1 (NEO) and 25.7 ng mL−1 (STP) by FDS method, respectively. The sensitivity of RRS method was the highest. The optimum conditions and influence factors were investigated. In addition, the reaction mechanism was discussed.  相似文献   

8.
A spectrofluorimetric method for the determination of trace amounts of the antibacterial trovafloxacin has been developed based on its native fluorescence in a micellar solution of sodium dodecyl sulfate (SDS). The wavelengths of excitation and emission were 270 nm and 410 nm, respectively. The optimised method allows the determination of 3.0–40.0 ng mL−1 of trovafloxacin in 8 mM SDS solution and 0.1 M acetic acid-sodium acetate buffer solution (pH 5.5), with a relative standard deviation of 1.5% (for a level of 12.0 ng mL−1) and a detection limit of 0.8 ng mL−1. The method was applied to the determination of trovafloxacin in human urine and serum samples. It was validated using HPLC as a reference method. Recovery levels of the method reached 100% in all cases.  相似文献   

9.
A method based on cloud point extraction and graphite furnace atomic absorption spectrometry (GFAAS) was developed for the analysis of trace tin in water samples. After cloud point extraction, the tin in the water samples was preconcentrated and successfully separated from most interferents. During the procedure, 8-hydroxyquinoline (8-HQ) was used as chelating reagent, and Triton X-114 was added as surfactant. The parameters affecting the sensitivity and the extraction efficiency, such as solution pH, concentration of 8-HQ and Triton X-114, equilibration temperature and centrifuge time, were evaluated and optimized. Under the optimum conditions, a preconcentration factor of 96.2 was obtained for a 20 mL water sample. The detection limit (LOD) was as low as 0.012 ng mL−1, and the analytical curve was linear in the range of 0.05–2.0 ng mL−1 with satisfactory precision (RSD <4.1%). The proposed method was successfully applied to the determination of trace tin in water samples with recoveries in the range of 85.0–112.0%.  相似文献   

10.
The use of rice husks as an alternative adsorbent in an on-line preconcentration system for Cd (II) and Pb (II) determination by flame atomic absorption spectrometry (FAAS) is described. The potential of rice husks as a natural adsorbent was evaluated as a material modified with 0.75 mol l−1 NaOH solution and in the unmodified form. For this task, several techniques such as spectroscopy and thermogravimetry were used for elucidation of possible functional groups responsible for the uptake of Cd (II) and Pb (II). Furthermore, based on adsorption studies and adsorption isotherms applied to the Langmüir model, it was possible to verify that modified rice husks present a higher adsorption capacity for both metals. After establishing this material as a promising natural adsorbent, it was used for on-line preconcentration of Cd (II) and Pb (II) metals. The multivariate optimisation of chemical and flow variables was performed by using a full factorial design (24) including the following factors: preconcentration time, preconcentration flow rate, concentration and volume of eluent. The optimum pH values used for on-line preconcentration were taken from prior univariate experiments. Under optimised conditions for Cd (II) determination (4 min of preconcentration at a 6 ml min−1 preconcentration flow rate, in which comprises 24 ml of preconcentration volume, 200 μl elution volume and 1.0 mol l−1 HNO3 solution as eluent), the system achieved a detection limit of 1.14 μg l−1 and an enrichment factor of 72.4. Similar conditions were used for Pb (II) determination (4 min of preconcentration, 6 ml min−1 preconcentration flow rate, 300 μl elution volume and 1.0 mol l−1 HNO3 solution as eluent) from which a detection limit of 14.1 μg l−1 and enrichment factor of 46.0 were achieved. Also, rice husks have been shown to be a homogeneous and stable adsorbent in which more than 100 preconcentration/elution cycles provide a relative standard deviation (RSD) of less than 6.0% on the analytical signal. The satisfactory accuracy of the method developed was obtained by using spiked water samples (mineral water and lake water) and spiked red wine samples. These values were confirmed by electrothermal atomic absorption spectrometry (ETAAS). The certified reference material [pig kidney (CRM 186)] and the reference material [beech leaves (CRM 100)] were also used.  相似文献   

11.
The reduction of 17-ketosteroid estrone or androstenedione to corresponding 17α- and 17β-estradiol or testosterone and epitestosterone has been performed with Saccharomyces cerevisiae. In the analysis of the cell culture, the solid-phase extraction (SPE) method was on-line coupled to high-performance liquid chromatography electrospray-ionization/mass spectrometry (HPLC-ESI/MS) for sample pretreatment to eliminate the complicated matrix interference and preconcentrate of the analytes before chromatographic separation. A novel quantification method with the continuous postcolumn infusion of internal standard was developed for the determination of substrate and products. This novel quantitative method can stabilize and enhance the ionization of all analytes during analysis. The HPLC-ESI/MS analysis of estrone, 17α-, and 17β-estradiol was operated with a negative ion mode and the analysis of androstenedione, testosterone, and epitestosterone was operated with a positive ion mode. The optimal concentration of the internal standard progesterone with the continuous postcolumn infusion technique was 3 μg mL−1 for estrogen analysis and 1 ng mL−1 for androgen analysis and both were at a constant infusion rate of 0.5 μL min−1. All of the linear correlation coefficients of the standard calibration curves were over 0.99 and had a linear range from 0 to 50 ng mL−1. The limit of detections (LODs) and the limit of quantitations (LOQs) for steroids analyzed were from 0.12 to 0.36 ng mL−1 and from 0.4 to 1.2 ng mL−1, respectively. The analysis accuracies and precisions were better than 94% and lower than 8.8% R.S.D., respectively. The developed method for the analysis of steroids in the cell culture was successful.  相似文献   

12.
A simple and reliable method has been developed for green separation and preconcentration of trace amounts of copper ions in aqueous solutions for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu2+ ions are adsorbed selectively and quantitatively during the passage of an aqueous solution through TDMBAC-treated analcime pyrocatechol-immobilized. The retained copper ions were desorbed from the column with 5.0 mL of 4 mol L−1 nitric acid solutions as eluent and were determined by FAAS. The linear range was 0.2-75 ng mL−1 in the original solution with a correlation coefficient of 0.9987. In this case we can concentrate 0.1 μg of copper from 1000 mL of solution and the proposed method permits a large enrichment factor (about 200). The detection limit of the proposed method is 0.05 ng mL−1 in the original solution (2σbl). Determination of copper in standard alloys showed that the proposed method has good accuracy (recovery was more than 97%). The method was successfully applied for recovery and determination of copper in several water samples.  相似文献   

13.
A new method of the determination polycyclic aromatic hydrocarbons (PAHs) in water samples was developed by continuous-flow microextraction (CFME) coupled with gas chromatography-mass spectrometry (GC-MS). In this experiment, 15 mL sample solution with no salt-added was flowed at the rate of 1.0 mL min−1 through 3 μL benzene as extraction solvent. Under the optimal extraction conditions, the developed method was found to yield a linear calibration curve in the concentration range from 0.05 to 15 ng mL−1. Furthermore, the accuracy and repeatability of the method were good by calculating from water samples spiked at known concentrations of PAHs, and the recovery of optimal method was satisfactory. The results showed that CFME was an efficient preconcentration method for extraction of PAHs from spiked water samples.  相似文献   

14.
The present article reports on the application of modified multiwalled carbon nanotubes (MMWCNTs) as a new, easily prepared and stable solid sorbent for the preconcentration of trace rhodium ion in aqueous solution. Rhodium ions were complexed with 1-(2-pyridylazo)-2-naphthol (PAN) in the pH range of 3.2-4.7 and then the formed Rh-PAN complex was adsorbed on the oxidized MWCNTs. The adsorbed complex was eluted from MWCNTs sorbent with 5.0 mL of N,N-dimethylformamide (DMF). The rhodium in eluted solution was determined by flame atomic absorption spectrometry (FAAS). Linear range for the determination of rhodium was maintained between 0.16 ng mL−1 and 25.0 μg mL−1 in initial solution. Relative standard deviation for the 10 replicated determination of 4.0 μg mL−1 of rhodium was ±0.97%. Detection limit was 0.010 ng mL−1 in initial solution (3Sbl, n = 10) and preconcentration factor was 120. Sensitivity for 1% absorbance of rhodium (III) was 0.112 μg mL−1. The sorption capacity of oxidized MWCNTs for Rh (III) was 6.6 mg g−1. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions were studied for the preconcentration of Rh3+. The proposed method was successfully applied to the extraction and determination of rhodium in different samples.  相似文献   

15.
A new functionalized mesoporous silica (MCM-41) using salicylaldehyde was utilized for the separation, preconcentration and determination of uranium in natural water by inductively coupled plasma atomic emission spectrometry (ICP-AES).Experimental conditions for effective adsorption of trace levels of U(VI) were optimized. The preconcentration factor was 100 (1.0 mL of elution for a 100 mL sample volume). The analytical curve was linear in the range 2-1000 μg L−1 and the detection limit was 0.5 ng mL−1. The relative standard deviation (R.S.D.) under optimum conditions was 2.5% (n = 10). Common coexisting ions did not interfere with the separation and determination of uranium at pH 5. The sorbent exhibited excellent stability and its sorption capacity under optimum conditions has been found to be 10 mg of uranium per gram of sorbent. The method was applied for the recovery and determination of uranium in different water samples.  相似文献   

16.
The present work proposes a direct method based on slurry sampling for the determination of zinc and copper in human hair samples by multi-element sequential flame atomic absorption spectrometry. The slurries were prepared by cryogenic grinding and sonication of the samples. The optimization step was performed using univariate methodology and the factors studied were: nature and concentration of the acid solution, amount sample/slurry volume, sonication time, and particle size. The established experimental conditions are the use of a sample mass of 50 mg, 2 mol L− 1 nitric acid solution, sonication time of 20 min and slurry volume of 10 mL. Adopting the optimized conditions, this method allows the determination of zinc and copper with detection limits of 88.3 and 53.3 ng g− 1, respectively, and precision expressed as relative standard deviation (RSD) of 1.7% and 1.6% (both, n = 10) for contents of zinc and copper of 100.0 and 33.3 μg g− 1, respectively. The accuracy was checked and confirmed by analysis of two certified reference materials of human hair. The procedure was applied for the determination of zinc and copper in two human hair samples. The zinc and copper contents varied from 100.0 to 175.6 and from 3.2 to 32.8 μg g− 1, respectively. These samples were also analyzed after complete digestion in a closed system and determination by FAAS. The statistical comparison by t-test (95% confidence level) showed no significant difference between these results.  相似文献   

17.
Quercetin can effectively accumulate at multi-walled carbon nanotubes-paraffin oil paste electrodes (CNTPE) and cause a sensitive anodic peak at around 0.32 V (vs. SCE) in a 0.10 M phosphate buffer solution (pH = 4.0). Under optimized conditions, the anodic peak current is linear to quercetin concentration in the ranges of 2.0 × 10− 9−1.0 × 10− 7 M and 1.0 × 10− 7−2.0 × 10− 5 M, and the regression equations are ip (μA) = 0.0017 + 0.928c (μM, r = 0.999) and ip (μA) = 0.183 + 0.0731c (μM, r = 0.995), respectively. This paste electrode can be regenerated by repetitively cycling in a blank solution for about 2 min. A 1.0 × 10− 6 M quercetin solution is measured for 10 times using the same electrode regenerated after every determination, and the relative standard deviation of the peak current is 1.7%. The method has been applied to the determination of quercetin in hydrolysate product of rutin and the recovery is 99.2–102.6%. In comparison with graphite paste electrode, carbon nanotubes-nujol paste electrode and carbon nanotubes casting film modified glassy carbon electrode, the CNTPE gives higher ratio of signal to background current and better defined voltammetric peak.  相似文献   

18.
In the present work, a new ligandless-dispersive liquid-liquid microextraction (LL-DLLME) method has been developed for preconcentration trace amounts of copper as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents, respectively. Some factors influencing on the extraction efficiency of copper and its subsequent determination were studied and optimized, such as the extraction and dispersive solvent type and volume, pH of sample solution, extraction time and salting out effect. Under the optimal conditions, the calibration curve was linear in the range of 1.0 ng mL−1-0.6 μg mL−1 of copper with R2 = 0.9985. Detection limit was 0.5 ng mL−1 in original solution (3Sb/m) and the relative standard deviation for seven replicate determination of 0.2 μg mL−1 copper was ±1.4%. The proposed method has been applied for determination of copper in standard and water samples with satisfactory results.  相似文献   

19.
Green onions (Allium fistulosum) enriched with 10 or 100 μg mL− 1 Se(IV) or SeMet were analyzed for total selenium and species distribution. Anion and cation exchange chromatographies were applied for the separation of selenium species with mass spectrometric detection. Two different sample preparation methods (NaOH and enzymatic) were compared from the Se extraction efficiency point of view. Total selenium concentration accumulated by the onions reached the 200 μg g− 1 level expressed for dry weight when applying SeMet at a concentration of 100 μg mL− 1 as the source of Se. Speciation studies revealed that both in onion bulbs and leaves the predominant form of organic selenium is Se-methyl-selenocysteine (MeSeCys). When Se(IV) was applied for Se-enrichment at a concentration level of 100 μg mL− 1 both onion leaf and bulb contained a significant amount of inorganic selenium. An unknown compound was also detected.  相似文献   

20.
This work reports the evaluation of the combined use of Pd and HF as chemical modifiers for the direct determination of total chromium in waters derived from petroleum exploration employing electrothermal atomic absorption spectrometry (ET AAS). Such waters, usually called as produced waters, have complex composition presenting a number of organic and inorganic substances. When obtained from offshore operations they also present high salinity. In order establish conditions for chromium measurement pyrolysis and atomization curves were built up in different media and employing Pd and HF as chemical modifiers. Also, a detailed study about calibration strategy was performed. At best conditions, pyrolysis and atomization temperatures were 1200 °C and 2600 °C, respectively, and 10 μL of a 500 mg L− 1 Pd solution was added together with 10 μL of a 50% (v/v) HF solution on 20 μL of sample. Obtained results indicate that, in this kind of sample, chromium can be determined by standard addition method or employing external calibration with standard solutions prepared in 0.8 mol L− 1 NaCl medium. In order to evaluate the accuracy of the procedure, a recovery test was performed with seven spiked samples of produced waters. The detection limit, quantification limit and the relative standard deviation in 0.8 mol L− 1 NaCl were also calculated and the values found were 0.45 μg L− 1, 1.5 μg L− 1 and 6.0% (at 2.5 μg L− 1 level), respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号