首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel ionic liquid (IL) bonded fused-sil-ica fiber for headspace solid-phase microextraction (HS-SPME)/gas chromatography-flame ionization detection (GC-FID) of methyl tert-butyl ether (MTBE) in a gasoline sample was prepared and used. The new proposed chemically bonded fiber has better thermal stability and durability than its corresponding physically coated fiber. Another advantage is that no spacer was used for the purpose of bonding the IL to the surface of the fused-silica. The latter advantage makes the preparation of these fibers easier with lower cost than those prepared using sol–gel method. The ionic liquid 1-methyl-3-(3-trimethoxysilyl propyl) imidazolium bis(trifluoromethylsulfonyl) imide was synthesized and cross linked to the surface of the fused-silica fiber. Then, the chemically IL-modified fibers were applied to the headspace extraction of MTBE. The chemically IL-modified fibers showed improved thermal stability at temperatures up to 220 °C relative to the physically IL-modified fibers (180 °C). The chemically bonded IL film on the surface of the fused-silica fiber was durable over 16 headspace extractions without any significant loss of the IL film. The calibration graph was linear in a concentration range of 2–240 μg L−1 (R2 = 0.996) with the detection limit of 0.1 μg L−1 level. The reproducibility (RSD %, n = 6) of the new IL bonded fused-silica fiber (8.9%) was better than the physically coated fiber (12%) suggesting that the proposed chemically IL-modified fiber is more robust than the physically IL-modified fiber. The optimum extraction conditions were the followings: 40 °C extraction temperature, 12 min extraction time, 30 s desorption time and sample agitation at 200 rpm.  相似文献   

2.
This study presents the development of an analytical method for determining 9 synthetic musks in water matrices. The developed method is based on stir bar sorptive extraction (SBSE), coated with polydimethylsiloxane, and coupled with a thermal desorption–gas chromatography–mass spectrometry system (TD–GC–MS). SBSE can efficiently trap and desorb the analytes providing low limits of detection (between 0.02 ng L−1 and 0.3 ng L−1). Method validation showed good linearity, repeatability and reproducibility for all compounds. Furthermore, the limited manipulation of the sample required in this method implies a significant decrease of the risk of external contamination of the samples. The performance of the method in real samples was evaluated by analysing biological wastewater treatment plant (WWTP) influent and effluent samples, reverse osmosis treatment plant effluents and river waters. The most abundant musk was galaxolide with values up to 2069 ng L−1 and 1432 ng L−1 in the influent and effluent of urban WWTP samples, respectively. Cashmeran, Pantolide and Tonalide were also detected in all the matrices with values up to 94 ng L−1, 26 ng L−1 and 88 ng L−1, respectively. Although in Europe the use of nitromusks in cosmetics is prohibited, musk xylene and musk ketone were detected both in the WWTP and in the river samples. As far as we know, this is the first time than a SBSE method coupled with TD is applied for the determination of synthetic musks in water samples.  相似文献   

3.
He L  Zhang K  Wang C  Luo X  Zhang S 《Journal of chromatography. A》2011,1218(23):3595-3600
An ionic liquid dispersive liquid–liquid microextraction high-performance liquid chromatography (IL-DLLME-HPLC) method for effective enrichment and determination of nitrite ion in water and biological samples was developed. The method was based on the reaction of nitrite ion with p-nitroaniline in the presence of diphenylamine in acid media and IL-DLLME of azo product. The optimization of reaction and extraction conditions, such as kind and concentration of acid, reaction time, volume of reaction solvent, temperature, kind of extraction and dispersive solvent, volume of extraction and dispersive solvent, addition of salt, extraction and centrifugal time were studied. Under the optimal conditions, 1-octyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide IL-DLLME procedure provided high enrichment factor of 430 and good extraction recovery of 91.7% for nitrite ion. The linearity was observed in the range of 0.4–500.0 μg L−1 with good correlation coefficient (r2 = 0.9996). The relative standard deviations (RSDs) for five replicate measurements varied between 1.5% and 4.8%. The limit of detection of the method (S/N = 3) was 0.05 μg L−1. The interference effect of some anions and cations was also tested. The developed method allowed achieving an excellent enrichment factor, yielding a lower LOD in comparison with other methods. Moreover, the proposed method was able to analyze nitrite ion in water and biological samples with satisfactory recovery ranged from 96.5% to 107.3%.  相似文献   

4.
The isolation and characterization of carbon nanofibers from soot obtained by burning natural oil is reported. The fibers were extracted from the soot with tetrahydrofuran followed by sonication. The carbon nanofibers were mixed with poly(vinyl alcohol) and electrospun to get the nanofiber mat. The extraction ability of electrospun nanofibers for the separation and preconcentration of aromatic compounds such as 3-nitroaniline, 4-chloroaniline, 4-bromoaniline and 3,4-dichloroaniline were tested and efficiently evaluated using high performance liquid chromatography. Under optimized conditions, the method showed good linearity in a range of 0.5–50 μg L−1 with correlation coefficient ranging from 0.989 to 0.998. High precision of the extraction with RSD values of 4.5–5.8% and low LOD value in a range of 0.009–0.081 μg L−1 for all aniline compounds were achieved. The proposed microextraction method offers advantages such as easy operation, high recovery, fast extraction, minimal use of organic solvent and elimination of tedious solvent evaporation and reconstitution steps.  相似文献   

5.
In this work a fast liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method using a C18 Fused Core™ column, was developed for the simultaneous analysis of bisphenol A diglycidyl ether (BADGE), bisphenol A (2,3-dihydroxypropyl) glycidyl ether (BADGE·H2O), bisphenol A bis(2,3-dihydroxypropyl) ether (BADGE·2H2O), bisphenol A (3-chloro-2-hydroxypropyl) glycidyl ether (BADGE·HCl), bisphenol A bis(3-chloro-2-hydroxypropyl) ether (BADGE·2HCl) and bisphenol A (3-chloro-2-hydroxypropyl)(2,3-dihydroxypropyl ether) (BADGE·HCl·H2O) and bisphenol F diglycidyl ether (BFDGE), bisphenol F bis(2,3-dihydroxypropyl) ether (BFDGE·2H2O), bisphenol F bis(3-chloro-2-hydroxypropyl) ether (BFDGE·2HCl). The LC method was coupled with a triple quadrupole mass spectrometer, using an ESI source in positive mode and using the [M+NH4]+ adduct as precursor ion for tandem mass spectrometry experiments. The method developed was applied to the determination of these compounds in canned soft drinks and canned food. OASIS HLB solid phase extraction (SPE) cartridges were used for the analysis of soft drinks, while solid canned food was extracted with ethyl acetate. Method limits of quantitation ranged from 0.13 μg L−1 to 1.6 μg L−1 in soft drinks and 1.0 μg kg−1 to 4.0 μg kg−1 in food samples. BADGE·2H2O was detected in all the analyzed samples, while other BADGEs such as BADGE·H2O, BADGE·HCl·H2O, BADGE·HCl and BADGE·2HCl were also detected in canned foods.  相似文献   

6.
A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid–liquid microextraction (USADLLME) procedure has been developed to preconcentrate geosmin and 2-methylisoborneol (MIB) from water and wine samples prior to quantification by gas chromatography–mass spectrometry (GC–MS). A two-stage multivariate optimization approach was developed by means of a Plackett–Burman design for screening and selecting the significant variables involved in the USADLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: solvent volume, 8 μL; solvent type: tetrachloroethylene; sample volume, 12 mL; centrifugation speed, 2300 rpm; extraction temperature 20 °C; extraction time, 3 min; and centrifugation time, 3 min. Under the optimized experimental conditions the method gave good levels of repeatability with coefficient of variation under 11% (n = 10). Limits of detection were 2 and 9 ng L−1 for geosmin and MIB, respectively. Calculated calibration curves gave high levels of linearity with correlation coefficient values of 0.9988 and 0.9994 for geosmin and MIB, respectively. Finally, the proposed method was applied to the analysis of two water (reservoir and tap) samples and three wine (red, rose and white) samples. The samples were previously analyzed and confirmed free of target analytes. Recovery values ranged between 70 and 113% at two spiking levels (0.25 μg L−1 and 30 ng L−1) showing that the matrix had a negligible effect upon extraction. Only red wine showed a noticeable matrix effect (70–72% recovery). Similar conclusions have been obtained from an uncertainty budget evaluation study.  相似文献   

7.
Wei R  Li W  Yang L  Jiang Y  Xie T 《Talanta》2011,83(5):334-1490
A sensitive method of online preconcentration followed by capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D) is evaluated as a novel approach for the determination of benzoic acid and sorbic acid in soy sauce. The online preconcentration technique, namely field-enhanced sample injection, coupled with CE-C4D were successfully developed and optimized. In order to reduce the complex matrix interference resulting from the constituents of soy sauce, a suitable sample clean-up procedure was also investigated for real sample pretreatment. Under optimized conditions, sorbic acid and benzoic acid were well separated within 10 min, and the detection limits were 0.05 μM (5.6 μg L−1) and 0.08 μM (9.8 μg L−1), respectively. The accuracy was tested by spiking 10.0 mg L−1 and 100.0 mg L−1 of standards in the soy sauce samples, and the recoveries were 95-99%, respectively. Results of this study show a great potential for the proposed method as a tool for the fast screening of benzoic acid and sorbic acid in a complex matrix.  相似文献   

8.
Enzymatic hydrolysis of seafood materials for isolating arsenic species (As(III), As(V), DMA and AsB) has been successfully performed by assisting the procedure with ultrasound energy (35 kHz) supplied by an ultrasound water-bath. The use of pepsin, as a proteolytic enzyme, under optimized operating conditions (pH 3.0, temperature 40 °C, enzyme to sample ratio of 0.3) led to an efficient assistance of the enzymatic process in a short period of time (from 4.0 to 30 min). The enzymatic extract was then subjected to a clean-up procedure based on ENVI-Carb™ solid phase extraction (SPE). An optimized anion exchange high performance liquid chromatography (HPLC) coupled to inductively coupled plasma-mass spectrometry (ICP-MS) permitted the fast separation (less than 15 min) of six different arsenic species (arsenite, As(III); arsenate, As(V); dimethylarsinic acid, DMA; and arsenobetaine, AsB; as well as monomethylarsonic acid, MMA; and arsenocholine, AsC) in a single run. Relative standard deviations (n = 11) of the over-all procedure were 7% for AsB and DMA, 11% for As(III) and 9% for MMA. HPLC–ICP-MS determinations were performed using aqueous calibrations covering arsenic concentrations of 0, 5, 10, 25, 100 and 200 μg L−1 (expressed as arsenic) for As(III), As(V), MMA, DMA and AsC; and 0, 125, 250, 500, 750, 1000 and 2000 μg L−1 (expressed as arsenic) for AsB. Germanium (5 μg L−1) was used as an internal standard. Analytical recoveries from the anion exchange column varied from 96 to 105% (enzymatic digests spiked with low target concentrations), from 97 to 104% (enzymatic digests spiked with intermediate target concentrations), and from 98 to 103% (enzymatic digests spiked with high target concentrations). The developed method was successfully applied to two certified reference materials (CRMs), DORM-2 and BCR 627, which offer certified AsB and DMA contents, and also to different seafood samples (mollusks, white fish and cold water fish). Good agreement between certified and found AsB concentrations was achieved when analyzing both CRMs; and also, between certified and found DMA concentrations in BCR 627. In addition, the sum of the different arsenic species concentrations found in most of the analyzed samples was statistically similar to the assessed total arsenic concentrations after a total sample matrix decomposition treatment.  相似文献   

9.
Cao Y  Wu X  Wang M 《Talanta》2011,84(4):1530-1194
Nucleic acids can greatly enhance fluorescence intensity of the kaempferol (Km)-Al(III) system in the presence of silver nanoparticles (AgNPs). Based on this, a novel method for the determination of nucleic acids is proposed. Under studied conditions, there are linear relationships between the extent of fluorescence enhancement and the concentration of nucleic acids in the range of 5.0 × 10−9 to 2.0 × 10−6 g mL−1 for fish sperm DNA (fsDNA), 7.0 × 10−9 to 2.0 × 10−6 g mL−1 for salmon sperm DNA (smDNA) and 2.0 × 10−8 to 3.0 × 10−6 g mL−1 for yeast RNA (yRNA), and their detection limits are 2.5 × 10−9 g mL−1, 3.2 × 10−9 g mL−1 and 7.3 × 10−9 g mL−1, respectively. Samples were satisfactorily determined. And the system of Km-Al(III)-AgNPs was used as a fluorescence staining reagent for sensitive DNA detection by DNA pattern of agarose gel electrophoresis analysis. The results indicate that the fluorescence enhancement should be attributed to the formation of Km-Al(III)-AgNPs-nucleic acids aggregations through electrostatic attraction and adsorption bridging action of Al(III) and the surface-enhanced fluorescence effect of AgNPs.  相似文献   

10.
Ren R  Wang Y  Zhang R  Gao S  Zhang H  Yu A 《Talanta》2011,83(5):6259-1400
A new method was developed for the determination of monolinuron, propazine, linuron, and prebane in environmental water samples. The solvent (ionic liquid) impregnated resin (IL-SIR)-based extraction coupled with dynamic ultrasonic desorption (DUSD) was applied to the separation and concentration of the analytes. The high performance liquid chromatography (HPLC) was applied to the determination of the analytes. The ionic liquid [C6MIM][PF6] was immobilized on Diaion HP20 resin by immersing the resin in ethanol solution containing [C6MIM][PF6]. The effect of extraction parameters, including pH value of sample solution, salt concentration in sample and extraction time, and elution conditions, including the concentration of ethanol in elution solvent, the flow rate of elution solvent and the ultrasonic power, were examined and optimized. The limits of detection and quantification for the analytes were in the range of 0.15-0.29 μg L−1 and 0.51-0.98 μg L−1, respectively. Some environmental water samples were analyzed and the analytical results were satisfactory.  相似文献   

11.
The detection of nitroaromatic compounds, best known as raw materials in explosives preparations, is important in many fields including environmental science, public security and forensics. CdSe quantum dots capped with PAMAM-G4 dendrimer were synthetized in water and used for the detection of trace amounts of three nitroaromatic compounds: 4-methoxy-2-nitrophenol (MNP), 2-amine-5-chloro-1,3-dinitrobenzene (ACNB) and 3-methoxy-4-nitrobenzoic acid (MNB). To increase the apparent water solubility of these compounds α-cyclodextrin (α-CD) was used to promote the formation of inclusion complexes. The studied nitroaromatic compounds (plus α-CD) significantly quenched the fluorescence intensity of the nanocomposite with linear Stern-Volmer plots. The Stern-Volmer constants (standard deviation in parenthesis) were: MNB, KSV = 65(5) × 104 M−1; ACNB, KSV = 19(2) × 104 M−1; and, MNP, KSV = 33(1) × 102 M−1. These constants suggest the formation of a ground state complex between the nitroaromatric compounds and the sensor which confers a relatively high analytical sensitivity. The detection sensibilities are about 0.01 mg L−1 for MNB and ACNB and about 0.1 mg L−1 for MNP. No interferences or small interferences are observed for trinitrotoluene [KSV = 10(2) × 102 × M−1], 2,4-dinitrotoluene [KSV = 20(3) × 10 M−1], 2,6-dinitrotoluene [KSV = 11(4) × 10 M−1] and nitrobenzene [KSV = 2(1) × 103 × M−1].  相似文献   

12.
We describe a selective pressurized liquid extraction (SPLE) method, followed by gas chromatography–mass spectrometry (GC–MS), for the simultaneous extraction and clean-up of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in sheep liver tissue samples. The on-line clean-up of liver tissue by SPLE was tested using differing amount of acid-modified silica (sulphuric acid:silica gel, 1:2, w/w), the most effective amount being 20 g. Different extraction solvents (iso-hexane and dichloromethane), either alone or in various combinations, were used to extract these target compounds from spiked liver samples. Variables affecting the SPLE extraction efficiency, including temperature, pressure, number of extraction cycles and static extraction time were studied; the optimum parameters were 80 °C, 10.3 MPa, 2 cycles and 5 min, respectively. The SPLE based method was compared with more traditional Soxhlet, off-line PLE, ultrasonic and heating extraction methods. Overall the mean percentage recoveries for all target chemicals using SPLE were 86–103% (n = 3, SD < 9%), and compared favourably with the Soxhlet (63–109%, n = 3, SD < 8%), off-line PLE (82–104%, n = 3, SD < 18%), ultrasonic (86–99%, n = 3, SD < 11%) and heating (72–102%, n = 3, SD < 21%) extraction methods. The limits of detection of the proposed method were 5–96 pg g−1 and 2–29 pg g−1 for the different PBDE and PCB chemicals studied, respectively. The outputs of the proposed method were linear over the range from 0.02 to 30 ng g−1, for all PCB and PBDE congeners except for PBDE 100 and 153 (0.05–30 ng g−1) and PBDE 183 (0.1–30 ng g−1). The method was successfully applied to sheep liver samples for the determination of the target PBDE and PCB compounds.  相似文献   

13.
Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol–gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 μg and 0.8 μg bar−1. The detection limit (3σ) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L−1 and the relative standard deviation (RSD) was 3.38% (c = 1 μg L−1, n = 7). The proposed method was successfully applied for the analysis of trace Cd(II) in rain water, East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples.  相似文献   

14.
A new sampling method was developed to collect vapor-phase polycyclic aromatic compounds (PAHs) downstream of a diesel engine equipped with a diesel particulate filter (DPF). This configuration allowed us to collect separately the particulate phase, which was trapped inside the DPF, and the vapor phase, which was sampled downstream of the DPF. PAHs, which were not predominantly absorbed into the poor organic fraction of the diesel soot, but were rather physically sorbed on high energetic adsorption sites, should be extracted using very drastic extraction conditions Microwave-assisted extraction using solvent mixtures composed of pyridine and diethylamine were used to desorb particulate PAHs, and the total PAH amounts corresponded to a very low value, i.e., 8 μg g−1 or 0.24 μg km−1, with a predominance of low weight PAHs. For collection of the vapor phase, gas bubbling in an aqueous medium was preferred to conventional methods, e.g., trapping on solid sorbents, for several reasons: aqueous trapping allowed us to use a solid phase enrichment process (SPE) that permitted PAH sampling at the sub-picogram levels. Consequently, low volume sampling was possible even if the sampling duration was very short (20 min). Additionally, the amount of time saved for the analysis was considerable when coupling SPE to the analytical system (liquid chromatography with fluorimetric detection). Solvent consumption for the overall sampling and analytical processes was also drastically reduced. Experiments on a diesel engine showed that vapor phase samples collected downstream of the DPF contained all of the 15 target priority PAHs, even the heaviest ones. The total vapor-phase PAH amount was 6.88 μg N m−3 or 10.02 μg km−1, which showed that the gaseous fraction contains more PAHs than the particulate fraction. Partitioning coefficients (Kp) were estimated showing the predominance in the vapor phase of all the PAHs. However, the DPF technology effects a considerable decrease in the total PAH emission when compared to non-equipped diesel vehicles.  相似文献   

15.
The feasibility of diluted nitric acid solutions for microwave-assisted decomposition of botanical samples in closed vessels was evaluated. Oxygen pressurized atmosphere was used to improve the digestion efficiency and Al, Ca, K, Fe, Mg and Na were determined in digests by inductively coupled plasma optical emission spectrometry (ICP OES). Efficiency of digestion was evaluated taking into account the residual carbon content (RCC) and residual acidity in digests. Samples were digested using nitric acid solutions (2, 3, 7, and 14 mol L−1 HNO3) and the effect of gas phase composition inside the reaction vessels by purging the vessel with Ar (inert atmosphere, 1 bar), air (20% of oxygen, 1 bar) and pure O2 (100% of oxygen, 1 bar) was evaluated. The influence of oxygen pressure was studied using pressures of 5, 10, 15 and 20 bar. It was demonstrated that a diluted nitric acid solution as low as 3 mol L−1 was suitable for an efficient digestion of sample masses up to 500 mg of botanical samples using 5 bar of oxygen pressure. The residual acidities in final digests were lower than 45% in relation to the initial amount of acid used for digestion (equivalent to 1.3 mol L−1 HNO3). The accuracy of the proposed procedure was evaluated using certified reference materials of olive leaves, apple leaves, peach leaves and pine needles. Using the optimized conditions for sample digestion, the results obtained were in agreement with certified values. The limit of quantification was improved up to a factor of 14.5 times for the analytes evaluated. In addition, the proposed procedure was in agreement with the recommendations of the green chemistry once it was possible to obtain relatively high digestion efficiency (RCC < 5%) using only diluted HNO3, which is important to minimize the generation of laboratory residues.  相似文献   

16.
A new separation and quantification method using ultra high-performance liquid chromatography (UHPLC) with UV detection was developed for the detection of sibiromycin in fermentation broth of Streptosporangium sibiricum. The solid phase extraction method based on cation-exchange was employed to pre-concentrate and purify fermentation broth containing sibiromycin prior to UHPLC analysis. The whole assay was validated and showed a linear range of detector response for the quantification of sibiromycin in a concentration from 3.9 to 250.0 μg mL−1, with correlation coefficient of 0.999 and recoveries ranging from 71.66 ± 3.55% to 74.76 ± 5.18%. Method limit of quantification of the assay was determined as 0.18 μg mL−1 and was verified with resulting RSD of 9.6% and accuracy of 97.6%. The developed assay was used to determine the sibiromycin production in 12 different fermentation broths. Moreover, several natural sibiromycin analogues/derivatives were described with pilot characterization using off-line mass spectrometry: the previously described dihydro-sibiromycin (DH-sibiromycin) and tentative bis-glycosyl forms of sibiromycin and its dihydro-analogue.  相似文献   

17.
Fragrances are widespread aquatic contaminants due to their presence in many personal care products used daily in developed countries. Levels of galaxolide and tonalide are commonly found in surface waters, urban wastewaters and river sediments. On the other hand, earthy-musty compounds confer bad odour to drinking water at levels that challenge the analytical capabilities. The combined determination of earthy-musty compounds and fragrances in water would be a breakthrough to make the traditional organoleptic evaluation of the water quality stricter and safer for the analyst. Two approaches were attempted to improve the analytical capabilities: analyte pre-concentration with a newly developed PDMS-DVB solid-phase microextraction fibre on metal alloy core and sensitive detection by tandem mass spectrometry (MS/MS). The optimization of SPME parameters was carried out using a central composite design and desirability functions. The final optimum extraction conditions were: headspace extraction at 70 °C during 40 min adding 200 g L−1 of NaCl. The detection limits in tandem MS (0.02-20 ng L−1) were marginally lower compared to full scan except for geosmin and trichloroanisol which go down to 0.1 and 0.02 ng L−1, respectively.The analysis of different water matrices revealed that fragrances and earthy-musty compounds were absent from ground- and drinking waters. Surface waters of river Leça contained levels of galaxolide around 250 ng L−1 in the 4 terminal sampling stations, which are downstream of WWTPs and polluted tributaries. Geosmine was ubiquitously distributed in natural waters similarly in rivers Leça and Douro at concentrations <7 ng L−1.  相似文献   

18.
Platform and wall vaporization for electrothermal vaporization (ETV)-inductively coupled plasma mass spectrometry (ICP-MS) determination of some refractory elements (Ti, V, Cr, Mo, La and Zr) and Pb were comparatively studied with the use of poly (tetrafluoroethylene) (PTFE) as fluorinating reagent. The factors affecting the vaporization behaviors of the target analytes in the platform and tube wall vaporization including vaporization temperature and time, pyrolytic temperature and time were studied in detail, and the flow rates of carrier gas/auxiliary carrier gas, were carefully optimized. Under the optimal conditions, the signal profiles, signal intensity, interferences of coexisting ions and analytical reproducibility for wall and platform vaporization ETV-ICP-MS were compared. It was found that both wall and platform vaporization could give very similar detection limits, but the platform vaporization provided higher signal intensity and better precision for some refractory elements and Pb than the wall vaporization. Especially for La, the signal intensity obtained by platform vaporization was 3 times higher than that obtained by wall vaporization. For platform vaporization ETV-ICP-MS, the limits of detection (LODs) of 0.001 μg L−1 (La) ~ 0.09 μg L− 1 (Ti) with the relative standard deviations (RSDs) of 1.5% (Pb) ~ 15.5% (Zr) were obtained. While for wall vaporization ETV-ICP-MS, LODs of 0.005 μg L− 1 (La) ~ 0.4 μg L− 1 (Pb) with RSDs of 3.2% (Mo) ~ 12.8% (Zr) were obtained. Both platform and tube wall vaporization techniques have been used for slurry sampling fluorination assisted ETV-ICP-MS direct determination of Ti, V, Cr, Mo, La, Zr and Pb in certified reference materials of NIES No. 8 vehicle exhaust particulates and GBW07401 soil, and the analytical results obtained are in good agreement with the certified values.  相似文献   

19.
Robust analytical procedures for the measurement of decamethylcyclopentasiloxane (D5) in river and estuarine sediments and their application in determining environmental concentrations in the UK are presented for the first time in this work. Novel approaches to minimise commonly reported artefacts are utilised, improving the confidence in the concentrations of D5 reported. Accelerated solvent extraction (ASE) and liquid–solid extraction methods are compared. Both methods use on-column injection gas chromatography/mass spectrometry (GC/MS). Measurements of D5 concentrations in sediments sampled from the river Great Ouse and from the Humber estuary (UK) are also reported. ASE was suitable to measure concentrations of D5 in sediments obtained from the river Great Ouse, UK (186–1450 ng g−1, dry weight) and octamethyltetracyclosiloxane (D4, 12–24 ng g−1, dry weight). C12 linear alkybenzene (C12 LAB), which can be used as a chemical marker for sewage effluent related emissions, was also measured in this analysis. Liquid–solid extraction was optimised to provide more confidence in the lower D5 concentrations measured in the Humber estuary, UK (49–256 ng g−1, dry weight). A Limit of quantitation (LOQ) for D5 of 57–110 and 4 ng g−1 dry weight was determined for ASE and liquid–solid extraction, respectively.  相似文献   

20.
A novel anionic exchange stir bar sorptive extraction (SBSE) coating based on poly(2-(methacryloyloxy)ethyltrimethylammonium chloride-co-divinylbenzene) monolithic material for the extraction of inorganic anion was prepared. The effect of preparation conditions such as ratio of functional monomer to cross-linker, content of porogenic solvent on the extraction efficiencies were investigated in detailed. The monolithic material was characterized by elemental analysis, scanning electron microscopy and infrared spectroscopy. In order to investigate the extraction capacity of the new coating for inorganic anion, the new SBSE was combined with ionic chromatography with conductivity detection, Br, NO3, PO43− and SO42− were selected as detected solutes. Several extractive parameters, including pH value and ionic strength in sample matrix, desorption solvent, extraction and desorption time were optimized. The results showed that strongly ionic strength did not favor the extraction of anlaytes. Under the optimum experimental conditions, low detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method for the target anions were achieved within the range of 0.92–2.62 and 3.03–9.25 μg/L, respectively. The method also showed good linearity, simplicity, practicality and low cost for the extraction inorganic anions. Finally, the proposed method was successfully used to detect the two different trademarks of commercial purified water with satisfactory recovery in the range of 70.0–92.6%. To the best of our knowledge, this is the first to use SBSE to enrich inorganic anions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号