1.
A collaborative study on the analysis for 15 + 1 EU priority PAHs in edible oils was organised to investigate the state-of-the-art of respective analytical methods. Three spiked vegetable oils, one contaminated native sunflower oil, and one standard solution were investigated in this study. The results of 52 laboratories using either high-performance liquid chromatography with fluorescence detection or gas chromatography with mass-selective detectors were evaluated by application of robust statistics. About 95% of the laboratories were able to quantify benzo[a]pyrene together with five other PAHs included in the commonly known list of 16 US-EPA PAHs. About 80% of the participants also quantified seven additional PAHs in most samples, two of which were benzo[b]fluoranthene and benzo[k]fluoranthene, which were also known from the EPA list. Only about 50% of the participants quantified cyclopenta[cd]pyrene, benzo[j]fluoranthene, and benzo[c]fluorene. The robust relative standard deviations of the submitted results without discrimination between the methods applied ranged between 100% for 5-methylchrysene in spiked olive oil and 11% for the same analyte in spiked sunflower oil. The results clearly showed that for these analytes the methods of analysis are not yet well established in European laboratories, and more collaborative trials are needed to promote further development and to improve the performances of the respective methods.  相似文献   

2.
In this study,a method based on low temperature purification(LTP) coupled with liquid chromatography-tandem mass spectrometry(LC-MS/MS) was developed for the determination of abamectin(ABA) and ivermectin(IVR) in edible oils.ABA and IVR were extracted using conventional liquid-liquid extraction followed by purification via precipitation of interfering fatty components at low temperature without an additional cleanup step.LTP is simple,easy to use,labour-saving and cost effective,and requires reduced amounts of organic solvent.The linear ranges of ABA and IVR were 5-1000 μg/L using matrix-matched standards.Limits of detection(LOD) and limits of quantification(LOQ)were in the range of 0.1-0.4 μg/kg and 0.3-1.3 μg/kg,respectively.The LOQs were below the strictest maximum residue limits established by Codex Alimentarius Commission.Recoveries at three spiked levels of 10,20 and 100 μg/kg in peanut oil,corn oil,olive oil,soybean oil and lard ranged from 71.1%to119.3%with relative standard deviations of 3.2%-10.3%,which were in agreement with those obtained by the solid phase extraction method.The proposed method was utilized in the analysis of 10 edible oil samples from local market and neither ABA nor IVR was detected.As far as we know,this is the first time that LTP is applied to the determination of avermectins in edible oils.  相似文献   

3.
A solid phase extraction-high performance liquid chromatography-tandem mass spectrometry based analytical method suitable for simultaneous analysis of benzidine, 3,3′-dichlorobenzidine, mono-, di-, and tri-chloroanilines has been developed.Normal phase separation by liquid chromatography was performed using a cyano propyl methyl silica column, and atmospheric pressure photoionization was employed as interface with mass spectrometer.The developed method was evaluated in terms of limit of detection, accuracy, and precision. The quantification limit for all the compounds ranged between 7 and 112 ng L−1, while recovery for all the compounds was higher than 94%. The method was tested by analyzing different industrial wastes, showing residual contamination by most of the analytes.  相似文献   

4.
A sensitive, simple, fast and rugged hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method for the determination of paroxetine was developed and validated over curve range 0.050-50 ng/mL using only 0.4 mL plasma. This is the first published LC-MS/MS method and the low limit of quantitation of this method is 10-fold lower than previously published methods. A simple liquid-liquid extraction method using methyl-tert butyl ether (MTBE) as the extraction solvent was used to extract paroxetine and the internal standard (IS) fentanyl-d(5) from plasma. The extract was evaporated to dryness, reconstituted and injected onto a silica column using a low aqueous-high organic mobile phase. The chromatographic run time was 2.0 min per injection, with retention times of 1.1 and 1.2 min for paroxetine and IS, respectively. The detection was by monitoring paroxetine at m/z 330 --> 192 and IS at m/z 342 --> 188, respectively. The inter-day precision and accuracy of the quality control (QC) samples were <5.0% relative standard deviation (RSD) and <2.9% relative error (RE). This method can be used for supporting therapeutical drug monitoring and pharmacokinetic or drug-drug interaction studies.  相似文献   

5.
In the present study, an effective high performance liquid chromatography–tandem mass spectrometric (HPLC/MS/MS) method was developed and validated to simultaneously determine bupropion (BUP), quetiapine (QUE) and escitalopram (ESC) in human plasma using carbidopa as the internal standard. Chromatographic separation was achieved on a Waters Sun Fire C18 column using reversed‐phase chromatography. The MS/MS experiment was performed in positive ion multiple reaction monitoring mode to produce product ions of m/z 240.3 → 184.2 for BUP, 384.2 → 253.1 for QUE, 325.3 → 109.3 for ESC and 227.2 → 181.2 for the internal standard. The method showed good linearity (R2 ≥ 0.997), precision (relative standard deviation ≤7.5%), satisfactory intra‐ and interday accuracy (88.4–113.0%) and acceptable extraction recovery (87.2–115.0%), matrix effect (84.5.5?108.7%) and stability (92.3?103.5%). The method was successfully applied to determine the concentrations of BUP, QUE and ESC in human plasma samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Shi Y  Sun C  Gao B  Sun A 《Journal of chromatography. A》2011,1218(42):7655-7662
A method for simultaneous determination of eight adulterants including two appetite suppressants, two energy expenditure-enhancing drugs, one diuretic and three cathartics in slimming functional foods by high performance liquid chromatography with electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) was established. After samples were ultrasonically extracted with 70% (v/v) methanol aqueous solution and centrifuged, the components of ephedrine, norpseudoephedrine, fenfluramine, sibutramine, clopamide, emodin, rhein, and chrysophanol in sample solution were separated by a Hypersil Gold column (2.1 mm × 150 mm, 5 μm) using a programmed gradient elution. A mobile phase consisting of 0.02% (v/v) formic acid-ammonium formate buffer solution (pH=3.50) and methanol was used for elution with a flow rate set at 250 μL/min and column temperature of 25 °C. Qualitative determination was based on characteristic ion pairs and retention time of the targeted compounds using SRM (selective reaction monitoring) mode. Clenbuterol and ibuprofen were internal standards in positive and negative ionization mode, respectively. The internal standard curves were used for quantification measurement. The average recoveries of three different concentrations were from 80.2% to 94.5%. The limits of detection (LODs) were from 0.03 to 0.66 mg/kg (except chrysophanol 1.6 mg/kg). The linear dynamic range covered from 1 to 500 μg/L (except chrysophanol 50-5000 μg/L) for the twelve samples analyzed. Adulterants in four different kinds of slimming functional foods were determined by this developed method, and satisfactory results were obtained. These experimental results showed that, adulteration of sibutramine or/and fenfluramine were the major adulterating components with contents varying from 6.1 to 1.3×10(3) mg/kg and 1.9 to 9.7×10(3) mg/kg, respectively. In addition, three cathartic compounds were detected in six of those tested samples, and ephedrine, norpseudoephedrine and clopamide were not detected in all samples.  相似文献   

7.
A rapid and sensitive LC‐MS/MS method for the quantification of fenofibric acid in rat plasma was developed and validated. Plasma samples were prepared by liquid–liquid extraction with a mixture of N‐hexane–dichloromethane–isopropanol (100:50:5, v/v/v). Isocratic chromatographic separation was performed on a reversed‐phase Discovery C18 column (2.1 × 50 mm, 5 µm). The mobile phase was methanol–water–formic (75:25:0.25, v/v/v). Detection of fenofibric acid and the internal standard (IS) diclofenac acid was achieved by ESI MS/MS in the negative ion mode using m/z 317 → m/z 213 and m/z 294 → m/z 250 transitions, respectively. The method was linear from 0.005 to 1.250 µg/mL when 100 μL plasma was analyzed. The lower limit of quantification was 0.005 µg/mL. The intra‐ and inter‐day precision values were below 8.2%, and accuracy ranged from ?0.9 to 2.1% in all quality control samples. The recovery was 90.3–94.7% and 83.3% for fenofibric acid and IS, respectively. Total run time for each sample analysis was 2.5 min. The validated method was successfully applied to a pharmacokinetic study in six rats after oral administration of fenofibrate, the ester prodrug of fenofibric acid (equivalent to fenofibric acid 5 mg/kg). The method permits laboratory scientists with access to the appropriate instrumentation to perform rapid fenofibric acid determination. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
A liquid chromatographic–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0834 and its amide hydrolysis metabolite (M1) in human plasma to support clinical development. The method consisted of semi‐automated 96‐well protein precipitation extraction for sample preparation and LC‐MS/MS analysis in positive ion mode using TurboIonSpray® for analysis. D6‐GDC‐0834 and D6‐M1 metabolite were used as internal standards. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 1 – 500 ng/mL for both GDC‐0834 and M1 metabolite. The accuracy (percentage bias) at the lower limit of quantitation (LLOQ) was 5.20 and 0.100% for GDC‐0834 and M1 metabolite, respectively. The precision (CV) for samples at the LLOQ was 3.13–8.84 and 5.20–8.93% for GDC‐0834 and M1 metabolite, respectively. For quality control samples at 3, 200 and 400 ng/mL, the between‐run CV was ≤7.38% for GDC‐0834 and ≤8.20% for M1 metabolite. Between run percentage bias ranged from ?2.76 to 6.98% for GDC‐0834 and from ?6.73 to 2.21% for M1 metabolite. GDC‐0834 and M1 metabolite were stable in human plasma for 31 days at ?20 and ?70°C. This method was successfully applied to support a GDC‐0834 human pharmacokinetic‐based study. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
An analytical method using liquid chromatography‐atmospheric pressure photoionization tandem mass spectrometry with toluene as a dopant was developed for the determination of triterpenes in medicinal plant extracts. The 12 compounds determined have been shown to exhibit biological activity, such as gastroprotective, hepatoprotective, anti‐inflammatory, antiviral and anti‐tumor effects. The parameters of the atmospheric pressure photoionization interface were optimized to obtain the highest possible sensitivity for all of the compounds. The limits of detection and quantification ranged from 0.4 to 157.9 µg l?1 and 1.3 to 526.4 µg l?1, respectively. The method was validated and applied to extracts of five medicinal plants species (Mansoa alliacea (Lam.) A.H.Gentry, Bauhinia variegata var variegata, Bauhinia variegata var alboflava, Cecropia obtuse Trécul and Cecropia palmate Willd) from the Amazonian region. The concentrations of the six triterpenes quantified in the samples ranged from 0.424 mg kg?1 for ursolic acid to 371.96 mg kg?1 for β‐amyrin, which were quantified by using the standard addition method (n = 3). Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
A liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0152 in human plasma to support clinical development. The method consisted of a solid‐phase extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d7‐GDC‐0152 was used as the internal standard. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 0.02–10.0 ng/mL for GDC‐0152. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 99.3% with a precision (%CV) of 13.9%. For quality control samples at 0.0600, 2.00 and 8.00 ng/mL, the between‐run %CV was ≤8.64. Between‐run percentage accuracy ranged from 98.2 to 99.6%. GDC‐0152 was stable in human plasma for 363 days at ?20°C and for 659 days at ?70°C storage. GDC‐0152 was stable in human plasma at room temperature for up to 25 h and through three freeze–thaw cycles. In whole blood, GDC‐0152 was stable for 12 h at 4°C and at ambient temperature. This validated LC‐MS/MS method for determination of GDC‐0152 was used to support clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
A focused-microwave assisted extraction method using aggregates of the ionic liquid (IL) 1-hexadecyl-3-butylimidazolium bromide (HDBIm-Br) followed by high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection and single-channel fluorescence detection (FLD) has been developed for the determination of polycyclic aromatic hydrocarbons (PAHs) in toasted cereals (“gofios”) of different nature (wheat, barley, rye, and maize corn) from the Canary Islands, Spain. The optimized HPLC-UV-vis/single-channel FLD method takes 40 min for the chromatographic run with limits of detection varying between 0.02 and 4.01 ng mL−1 for the fluorescent PAHs from the European Union (EU) priority list in foods, and 20.5 ng mL−1 for the non-fluorescent PAH cyclopenta[c,d]pyrene (CPP). The optimized microwave step presented extractions recoveries ranging from 70.1 to 109% and precision values lower than 12.6% (as relative standard deviation), using an extraction time of 14 min. The extraction method also utilizes low amounts of sample (0.1 g), and low amounts of IL (77 mg), avoiding completely the use of organic solvents.  相似文献   

12.
One of the many issues of designer drugs of abuse like synthetic cannabinoids (SCs) such as JWH‐018 is that details on their metabolism has yet to be fully elucidated and that multiple metabolites exist. The presence of isomeric compounds poses further challenges in their identification. Our group has previously shown the effectiveness of gas chromatography‐electron ionization‐tandem mass spectrometry (GC‐EI‐MS/MS) in the mass spectrometric differentiation of the positional isomers of the naphthoylindole‐type SC JWH‐081, and speculated that the same approach could be used for the metabolite isomers. Using JWH‐018 as a model SC, the aim of this study was to differentiate the positional isomers of its hydroxyindole metabolites by GC‐MS/MS. Standard compounds of JWH‐018 and its hydroxyindole metabolite positional isomers were first analyzed by GC‐EI‐MS in full scan mode, which was only able to differentiate the 4‐hydroxyindole isomer. Further GC‐MS/MS analysis was performed by selecting m/z 302 as the precursor ion. All four isomers produced characteristic product ions that enabled the differentiation between them. Using these ions, MRM analysis was performed on the urine of JWH‐018 administered mice and determined the hydroxyl positions to be at the 6‐position on the indole ring. GC‐EI‐MS/MS allowed for the regioisomeric differentiation of the hydroxyindole metabolite isomers of JWH‐018. Furthermore, analysis of the fragmentation patterns suggests that the present method has high potential to be extended to hydroxyindole metabolites of other naphthoylindole type SCs in identifying the position of the hydroxyl group on the indole ring. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
A rapid and reliable LC-MS/MS method for the simultaneous confirmation of twelve non steroidal anti-inflammatory drugs (NSAIDs) in bovine milk was developed and fully validated in accordance with the European Commission Decision 2002/657/EC. The validation scheme was built in accordance with the MRLs or target analytical levels (EU-CRL recommended concentrations and detection capabilities) of the analytes, except for diclofenac for which the lower level of validation achieved was 0.5 μg kg(-1) whereas its MRL is 0.1 μg kg(-1). The NSAIDs investigated were as follows: phenylbutazone (PBZ), oxyphenylbutazone (OPB), naproxen (NP), mefenamic acid (MF), vedaprofen (VDP), flunixin (FLU), 5-hydroxyflunixin (FLU-OH), tolfenamic acid (TLF), meloxicam (MLX), diclofenac (DC), carprofen (CPF) and ketoprofen (KTP). Several extraction procedures had been investigated during the development phase. Finally, the best results were obtained with a procedure using only methanol as the extraction solvent, with an evaporation step included and no further purification. Chromatographic separation was achieved on a C18 analytical column and the run was split in 2 segments. Matrix effects were also investigated. Data acquisition implemented for the confirmatory purpose was performed by monitoring 2 MRM transitions per analyte under the negative electrospray mode. Mean relative recoveries ranged from 94.7% to 110.0%, with their coefficients of variation lying between 2.9% and 14.7%. Analytical limits expressed in terms of decision limits (CCα) were evaluated between 0.69 μg kg(-1) (FLU) and 27.54 μg kg(-1) (VDP) for non-MRL compounds, and at 0.10 (DC), 15.37 (MLX), 45.08 (FLU-OH), and 62.96 μg kg(-1) (TLF) for MRL compounds. The validation results proved that the method is suitable for the screening and confirmatory steps as implemented for the French monitoring plan for NSAID residue control in bovine milk.  相似文献   

14.
A liquid chromatographic–electrospray ionization–time‐of‐flight/mass spectrometric (LC‐ESI‐TOF/MS) method was developed and applied for the determination of WKYMVm peptide in rat plasma to support preclinical pharmacokinetics studies. The method consisted of micro‐elution solid‐phase extraction (SPE) for sample preparation and LC‐ESI‐TOF/MS in the positive ion mode for analysis. Phenanthroline (10 mg/mL) was added to rat blood immediately for plasma preparation followed by addition of trace amount of 2 m hydrogen chloride to plasma before SPE for stability of WKYMVm peptide. Then sample preparation using micro‐elution SPE was performed with verapamil as an internal standard. A quadratic regression (weighted 1/concentration2), with the equation y = ax2 + bx + c was used to fit calibration curves over the concentration range of 3.02–2200 ng/mL for WKYMVm peptide. The quantification run met the acceptance criteria of ±25% accuracy and precision values. For quality control samples at 15, 165 and 1820 ng/mL from the quantification experiment, the within‐run and the between‐run accuracy ranged from 92.5 to 123.4% with precision values ≤15.1% for WKYMVm peptide from the nominal values. This novel LC‐ESI‐TOF/MS method was successfully applied to evaluate the pharmacokinetics of WKYMVm peptide in rat plasma.  相似文献   

15.
A sensitive and reliable liquid chromatography/photoionization (APPI) tandem mass spectrometry method has been developed for determining nine selected mycotoxins in wheat and maize samples. The analytes were chosen on the basis of the mycotoxins under EU Commission Regulation (EC) No. 1881/2006, i.e., deoxynivalenol (DON), zearalenone (ZON), aflatoxins (AFs), and ochratoxin A (OTA), and considering the possibility of a near future regulation for T-2 and HT-2 toxins. Mycotoxins were extracted from samples by means of an one-step solvent extraction without any cleanup. The developed multi-mycotoxin method permits simultaneous, simple, and rapid determination of several co-existing toxins separated in a single chromatographic run, in which AFs, T-2 and HT-2 toxin are acquired in positive, while OTA, DON and ZON in negative mode. Although a moderate signal suppression was noticeable, matrix effect did not give significant differences at p = 0.05. Then, calibration in standard solution were used for quantitation. Based on the EU Commission Decision 2002/657/EC, the method was in-house validated in terms of ruggedness, specificity, linearity, trueness, within-laboratory reproducibility, decision limit (CCα) and detection capability (CCβ). For all the analytes, the regression coefficient r ranged between 0.8752 (DON in wheat) and 0.9465 (ZON in maize), biases related to mean concentrations were from −13% to +12% of the nominal spiking level, and the overall within-laboratory reproducibility ranged 3–16%; finally, CCα values did not differ more than 20% and CCβ not more than 42% from their respective maximum limit. Method quantification limits ranged from 1/20 (AFG1) to 1/4 (AFG2 and OTA) the maximum limit established by European Union in the Commission Regulation (EC) No. 1881/2006 and its subsequent amendments.  相似文献   

16.
This paper presents the optimisation of a programmed temperature vaporization solvent vent (PTV-SV) injection gas chromatographic mass spectrometric (GC-MS) method for the analysis of the 15 + 1 EU-priority PAHs in food extracts. Three operation parameters (vent time, vent flow and vent pressure) were optimised by applying a D-optimal experimental design. Among these variables, vent time showed the highest effect on the analytical response (signal intensity) of the target PAHs.The 15 + 1 EU-priority PAHs were analysed in solvent solutions and in extracts of fortified sausage. In addition, blank lamb meat extracts were prepared and spiked with the target PAHs prior to GC-MS analysis. The performance of the optimised PTV-SV injection GC-MS method was scrutinised for linearity, precision, matrix effects and robustness. All parameters were found satisfactorily. Compared to PTV injection in splitless mode, the PTV-SV injection method provided an enhancement of sensitivity for all target PAHs. Especially significant was the improvement of the S/N ratios of the compounds with the highest molecular mass.  相似文献   

17.
In this work, a liquid chromatography–tandem mass spectrometric detection technique was developed and validated for the determination of brotizolam residues in beef muscle and commercial whole milk. This procedure involves the extraction of the analyte from the samples via liquid–solid extraction, and caffeine was used as an internal standard. The analyte was successfully separated on an XTerra‐C18 column, with a mobile phase composed of 0.01% formic acid in acetonitrile and 1 mm ammonium formate–0.01% formic acid in water. The one‐step extraction method evidenced good selectivity, precision (RSD = 9.87–26.47%), and the recovery of the extractable analyte was 92.61–115.98% in the matrices. The limits of quantification ranged between 0.4 and 0.5 µg/kg. The developed method is simple since it requires no additional cleanup procedures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
In the present study we developed and validated a liquid chromatography/tandem mass spectrometry (LC‐MS/MS) assay for the determination of flucloxacillin in human plasma and microdialysis samples and cloxacillin in microdialysis samples, using oxacillin as the internal standard for the assay. The samples were separated on a UPLC BEH C18,1.7 µm column (2.1 × 50 mm) and analyzed by a tandem–quadrupole mass spectrometer in multiple reaction monitoring mode using an electronspray ionization interface. For flucloxacillin the method was demonstrated to be accurate and precise in the linearity range of 1–30 mg/L in plasma and 0.05–5.0 mg/L for microdialysate with a regression coefficient (r) of 0.9986 and 0.9989 in plasma and microdialysate respectively. For cloxacillin it was accurate and precise in the range of 0.1–5.0 mg/L for microdialysate with a regression coefficient of 0.9972. The method presents a high sensitivity for flucloxacillin (lower limit of quantification of 1 mg/L for plasma and 0.05 mg/L for microdialysis samples) combined with a low within‐ and between‐day variation (<5.0% for flucloxacillin and cloxacillin in microdialysis samples and <6.5% for plasma samples of flucloxacillin). The validation experiments for the microdialysis probes showed a relative recovery of 85.5% for flucloxacillin at a flow rate of 1.0 μL/min. The results justify the use of this assay for clinical studies for measuring free unbound tissue concentrations of flucloxacillin in patients with a Staphylococcus aureus bacteremia. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
A sensitive and specific high‐performance liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed for the determination of Grayanotoxin I (GTX I) and Grayanotoxin III (GTX III) in rat whole blood. Grayanotoxins (GTXs) and clindamycin as internal standard (IS) were extracted from rat blood via solid‐phase extraction using PEP solid‐phase extraction cartridges. Chromatographic separation of the analytes was achieved on a Kinetex C18 (100 × 2.1 mm, 2.6 µm) reversed‐phase column using a gradient elution with the mobile phase of 1% acetic acid in water and methanol at a flow rate of 0.2 mL/min. Electrospray ionization mass spectrometry was operated in the positive ion mode with multiple reaction monitoring. The calibration curves obtained were linear over the concentration range of 1–100 ng/mL with a lower limit of quantification of 1 ng/mL for GTXs. The relative standard deviation of intra‐day and inter‐day precision was below 6.8% and accuracy ranged from 94.8 to 106.6%. The analytes were stable in the stability studies. The validated method was successfully applied to the quantification and toxicokinetic study of GTXs in rats for the first time after oral administration of 11.52 mg/kg mad honey and 0.35 mg/kg GTX III, respectively. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
Omarigliptin is a novel long‐acting dipeptidyl peptidase‐4 inhibitor used for the treatment of type 2 diabetes. In this work, a sensitive and selective ultra‐high pressure liquid chromatography tandem mass spectrometry method was developed and validated for the determination of omarigliptin in rat plasma. Sample preparation was performed by protein precipitation with acetonitrile. Chromatographic separation of analytes was achieved on an RRHD Eclipse Plus C18 column (2.1 × 50 mm, 1.8 μm), using gradient mobile phase (0.1% formic acid–acetonitrile) at a flow rate of 0.4 mL/min. Detection was performed in multiple reaction monitoring mode, with target fragment ions m/z 399.1 → 152.9 for omarigliptin and m/z 237.1 → 194 for the internal standard. The total run time was 4 min. Retention time of omarigliptin and internal standard was 1.25 and 2.12 min, respectively. Relative standard deviation (%) of the intra‐ and inter‐day precision was below 10.0%, and accuracy was between 97.9% and 105.3%. Calibration curve was established over the range 2–5000 ng/mL with good linearity. The lower limit of quantification and limit of detection of omarigliptin were 2 and 0.25 ng/mL, respectively. Mean recoveries were in the range 87.3–95.1% for omarigliptin. No matrix effect was observed in this method. This novel method has been successfully applied to a pharmacokinetic study of omarigliptin in rats. The absolute bioavailability of omarigliptin was identified as high as 87.31%.  相似文献   