Purpose

To optimize the navigator-gating technique for the acquisition of high-quality three-dimensional spoiled gradient-recalled echo (3D SPGR) images of the liver during free breathing.

Materials and methods

Ten healthy volunteers underwent 3D SPGR magnetic resonance imaging of the liver using a conventional navigator-gated 3D SPGR (cNAV-3D-SPGR) sequence or an enhanced navigator-gated 3D SPGR (eNAV-3D-SPGR) sequence. No exogenous contrast agent was used. A 20-ms wait period was inserted between the 3D SPGR acquisition component and navigator component of the eNAV-3D-SPGR sequence to allow T1 recovery. Visual evaluation and calculation of the signal-to-noise ratio were performed to compare image quality between the imaging techniques.

Result

The eNAV-3D-SPGR sequence provided better noise properties than the cNAV-3D-SPGR sequence visually and quantitatively. Navigator gating with an acceptance window of 2 mm effectively inhibited respiratory motion artifacts. The widening of the window to 6 mm shortened the acquisition time but increased motion artifacts, resulting in degradation of overall image quality. Neither slice tracking nor incorporation of short breath holding successfully compensated for the widening of the window.

Conclusion

The eNAV-3D-SPGR sequence with an acceptance window of 2 mm provides high-quality 3D SPGR images of the liver.  相似文献   

2.

Purpose

To examine mesenchymal stem cell (MSC) labeling with micrometer-sized iron oxide particles (MPIOs) for magnetic resonance imaging (MRI)-based tracking and its application to monitoring articular cartilage regeneration.

Methods

Rabbit MSCs were labeled using commercial MPIOs. In vitro MRI was performed with gradient echo (GRE) and spin echo (SE) sequences at 3T and quantitatively characterized using line profile and region of interest analysis. Ex vivo MRI of hydrogel-encapsulated labeled MSCs implanted within a bovine knee was performed with spoiled GRE (SPGR) and T sequences. Fluorescence microscopy, labeling efficiency, and chondrogenesis of MPIO-labeled cells were also examined.

Results

MPIO labeling results in efficient contrast uptake and signal loss that can be visualized and quantitatively characterized via MRI. SPGR imaging of implanted cells results in ex vivo detection within native tissue, and T imaging is unaffected by the presence of labeled cells immediately following implantation. MPIO labeling does not affect quantitative glycosaminoglycan production during chondrogenesis, but iron aggregation hinders extracellular matrix visualization. This aggregation may result from excess unincorporated particles following labeling and is an issue that necessitates further investigation.

Conclusion

This study demonstrates the promise of MPIO labeling for monitoring cartilage regeneration and highlights its potential in the development of cell-based tissue engineering strategies.  相似文献   

3.

Purpose

To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system.

Materials and Methods

DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR GRE EPI and IR-prepped GRE sequences (SAR: 0.42 and 0.39 W/kg, respectively), and the high-SAR 4-echo RF spin echo (SAR: 2.9 W/kg). Fluoroptic thermometry was used to directly measure RF-related heating at the DBS electrodes, and at the implantable pulse generator (IPG). For reference the measurements were repeated in the same pig at 1.5 T and, at both field strengths, in a phantom.

Results

At 3.0 T, the maximal temperature elevations at DBS electrodes were 0.46 °C and 2.3 °C, for the low- and high-SAR sequences, respectively. No heating was observed on the implanted IPG during any of the measurements. Measurements of in vivo heating differed from those obtained in the phantom.

Conclusion

The 3.0-T MRI using GRE EPI and IR-prepped GRE sequences resulted in local temperature elevations at DBS electrodes of no more than 0.46 °C. Although no extrapolation should be made to human exams and much further study will be needed, these preliminary data are encouraging for the future use 3.0-T MRI in patients with DBS.  相似文献   

4.

Introduction

To clarify the mechanism underlying apparent diffusion coefficient (ADC) changes in regional intracranial tissue during the cardiac cycle, we investigated relationships among ADC changes, volume loading, and intracranial pressure using a hemodialyzer phantom in magnetic resonance imaging (MRI).

Materials and Methods

The hemodialyzer phantom consisted of hollow fibers (HF), the external space of HFs (ES), and a gateway of dialysis solution, filled with syrup solution and air. The high-volume and low-volume loadings were periodically applied to HFs by a to-and-fro flow pump, and syrup solution was permitted to enter or leave HFs during the volume loading cycles. ADC maps at each volume loading phase were obtained using ECG-triggered single-shot diffusion echo-planar imaging. Dynamic phase contrast MRI was also used to measure volume loading to the phantom. We compared the ADC changes, volume loading, and intracranial pressure in the phantom during the cardiac cycle.

Results

ADC changes synchronized significantly with absolute volumetric flow rate change. The maximum ADC change was higher in high-volume loading cycles than in low-volume loading cycles. Results showed that the water molecules in ES fluctuated according to the force transferred from HF to ES. ADC changes were dependent upon the volumetric flow rate during the cardiac cycle.

Conclusions

Our original phantom allowed us to clarify the mechanism underlying water fluctuations in intracranial tissues. Measurement of maximum changes in ADC is an effective method to define the transfer characteristics of the arterial pulsatile force in regional intracranial tissue.  相似文献   

5.
The sequence of the ground states in SrTiO3 films subjected to epitaxial strain and fixed mechanical stress in the [001] and [110] directions is calculated from first principles within the density functional theory. Under the fixed-strain conditions, an increase in the substrate lattice parameter results in the following sequence of the ground states: I4cmI4/mcmIma2 → CmFmm2 → Ima2(II). When moving to the fixed-stress conditions, the phase sequence changes significantly and depends on how the stress is applied. It is revealed that the simultaneous presence of two types of the lattice instability (the ferroelectric and structural ones) in strontium titanate leads to the formation of a whole system of metastable phases whose number increases abruptly under the fixed-stress conditions. The stability of these phases changes with pressure and phase transitions occur between them. The appearance of broad bistability regions in certain parts of the phase diagram enables the use of this phenomenon for developing nonvolatile phase-change memory.  相似文献   

6.

Purpose

We evaluated the ability of diffusion-weighted imaging (DWI) to detect bone metastasis by comparing the results obtained using this modality with those obtained using 11C-methionine (MET) positron emission tomography (PET) and bone scintigraphy.

Materials and methods

This retrospective study involved 29 patients with bone metastasis. DWI was obtained using a single-shot echo planar imaging (EPI) sequence with fat suppression using a short inversion time inversion recovery sequence. The detection capabilities of DWI for bone metastases were compared with those of whole body MET PET (in 19 patients) and 99mTc-methylene diphosphonate bone scintigraphy (in 15 patients).

Results

Among the 19 patients who were diagnosed using DWI and PET, the PET identified 39 bone metastases, while the DWI identified 60 metastases out of 69 metastases revealed with conventional magnetic resonance imaging (MRI). Among the 15 patients who were diagnosed using DWI and bone scintigraphy, the bone scintigraphy identified 18 bone metastases, while the DWI identified 72 metastases out of 78 metastases revealed with conventional MRI. The overall bone metastasis detection rates were 56.5% for PET, 23.1% for bone scintigraphy and 92.3% for DWI.

Conclusion

DWI is a very sensitive method for detecting bone metastasis and is superior to MET PET and bone scintigraphy in terms of its detection capabilities.  相似文献   

7.

Purpose

The purpose was to evaluate radiofrequency (RF)-related heating of commonly used extracranial neurosurgical implants in 7-T magnetic resonance imaging (MRI).

Materials and methods

Experiments were performed using a 7-T MR system equipped with a transmit/receive RF head coil. Four commonly used titanium neurosurgical implants were studied using a test procedure adapted from the American Society for Testing and Materials Standard F2182-11a. Implants (n = 4) were tested with an MRI turbo spin echo pulse sequence designed to achieve maximum RF exposure [specific absorption rate (SAR) level = 9.9 W/kg], which was further validated by performing calorimetry. Maximum temperature increases near each implant's surface were measured using fiberoptic temperature probes in a gelled-saline-filled phantom that mimicked the conductive properties of soft tissue. Measurement results were compared to literature data for patient safety.

Results

The highest achievable phantom averaged SAR was determined by calorimetry to be 2.0 ± 0.1 W/kg due to the highly conservative SAR estimation model used by this 7-T MR system. The maximum temperature increase at this SAR level was below 1.0 °C for all extracranial neurosurgical implants that underwent testing.

Conclusion

The findings indicated that RF-related heating under the conditions used in this investigation is not a significant safety concern for patients with the particular extracranial neurosurgical implants evaluated in this study.  相似文献   

8.

Objective

Development of a fast 3D high-resolution magnetic resonance imaging (MRI) protocol for improved carotid artery plaque imaging.

Methods

Two patients with carotid atherosclerosis disease underwent 3D high-resolution MRI which included time-of-flight and T1-weighted variable flip angle, fast-spin-echo (FSE) imaging, pre- and post-intravenous gadolinium-based contrast agent administration.

Results

Good quality images with intrinsic blood suppression were obtained pre- and post-contrast administration using a 3D FSE sequence. The plaque burden, lipid core volume, hemorrhage volume and fibrous cap thickness were well determined.

Conclusions

3D high-resolution MR imaging of carotid plaque using TOF and 3D FSE can achieve high isotropic resolution, large coverage, and excellent image quality within a short acquisition time.  相似文献   

9.

Objective:

The objective in this work is to investigate the feasibility of using a new imaging tool called vibro-acoustography (VA) as a means of permanent prostate brachytherapy (PPB) seed localization to facilitate post-implant dosimetry (PID).

Methods and materials:

Twelve OncoSeed (standard) and eleven EchoSeed (echogenic) dummy seeds were implanted in a human cadaver prostate. Seventeen seeds remained after radical retropubic prostatectomy. VA imaging was conducted on the prostate that was cast in a gel phantom and placed in a tank of degassed water. 2-D magnitude and phase VA image slices were obtained at different depths within the prostate showing location and orientation of the seeds.

Results:

VA demonstrates that twelve of seventeen (71%) seeds implanted were visible in the VA image, and the remainder were obscured by intra-prostatic calcifications. Moreover, it is shown here that VA is capable of imaging and locating PPB seeds within the prostate independent of seed orientation, and the resulting images are speckle free.

Conclusion:

The results presented in this research show that VA allows seed detection within a human prostate regardless of their orientation, as well as imaging intra-prostatic calcifications.  相似文献   

10.

Purpose

Quantitative imaging of the rat skin was performed using magnetic resonance imaging (MRI) at 900 MHz.

Materials and methods

A number of imaging techniques utilized for multiple contrast included magnetization transfer contrast, spin-lattice relaxation constant (T1-weighting), combination of T2-weighting with magnetic field inhomogeneity (T2*-weighting), magnetization transfer weighting and diffusion tensor weighting. These were used to obtain 2D slices and 3D multislice-multiecho images with high magnetic resonance contrast. These 2D and 3D imaging techniques were combined to achieve high-resolution MRI.

Results

Oil–water phantom showed distinct fat-water contrast. The dermis and epidermis, including the stratum corneum remnants, of nude rat skin were distinct due to their proton magnetic resonance as a result of proton interactions with the skin interstitial tissue. Combined details obtained from high-resolution, high-quality ex vivo skin images with different multicontrast characteristics generated better differentiation of skin layers, sublayers and significant correlation (r2=0.4927 for MRI area, r2=0.3068 for histology area; P<.0148) of MR data with co-registered histological areas of the epidermis as well as the hair follicle.

Conclusion

The multiple contrast approach provided a noninvasive ex vivo MRI visualization with semi-quantitative assessment of the major skin structures including the stratum corneum remnants, epidermis, hair, papillary dermis, reticular dermis and hypodermis.  相似文献   

11.

Objective and motivation

This work reports original results on the possibility of non-invasive temperature estimation (NITE) in a multilayered phantom by applying soft-computing methods. The existence of reliable non-invasive temperature estimator models would improve the security and efficacy of thermal therapies. These points would lead to a broader acceptance of this kind of therapies. Several approaches based on medical imaging technologies were proposed, magnetic resonance imaging (MRI) being appointed as the only one to achieve the acceptable temperature resolutions for hyperthermia purposes. However, MRI intrinsic characteristics (e.g., high instrumentation cost) lead us to use backscattered ultrasound (BSU). Among the different BSU features, temporal echo-shifts have received a major attention. These shifts are due to changes of speed-of-sound and expansion of the medium.

Novelty aspects

The originality of this work involves two aspects: the estimator model itself is original (based on soft-computing methods) and the application to temperature estimation in a three-layer phantom is also not reported in literature.

Materials and methods

In this work a three-layer (non-homogeneous) phantom was developed. The two external layers were composed of (in % of weight): 86.5% degassed water, 11% glycerin and 2.5% agar-agar. The intermediate layer was obtained by adding graphite powder in the amount of 2% of the water weight to the above composition. The phantom was developed to have attenuation and speed-of-sound similar to in vivo muscle, according to the literature. BSU signals were collected and cumulative temporal echo-shifts computed. These shifts and the past temperature values were then considered as possible estimators inputs. A soft-computing methodology was applied to look for appropriate multilayered temperature estimators. The methodology involves radial-basis functions neural networks (RBFNN) with structure optimized by the multi-objective genetic algorithm (MOGA). In this work 40 operating conditions were considered, i.e. five 5-mm spaced spatial points and eight therapeutic intensities (ISATA): 0.3, 0.5, 0.7, 1.0, 1.3, 1.5, 1.7 and . Models were trained and selected to estimate temperature at only four intensities, then during the validation phase, the best-fitted models were analyzed in data collected at the eight intensities. This procedure leads to a more realistic evaluation of the generalisation level of the best-obtained structures.

Results and discussion

At the end of the identification phase, 82 (preferable) estimator models were achieved. The majority of them present an average maximum absolute error (MAE) inferior to 0.5 °C. The best-fitted estimator presents a MAE of only 0.4 °C for both the 40 operating conditions. This means that the gold-standard maximum error (0.5 °C) pointed for hyperthermia was fulfilled independently of the intensity and spatial position considered, showing the improved generalisation capacity of the identified estimator models. As the majority of the preferable estimator models, the best one presents 6 inputs and 11 neurons. In addition to the appropriate error performance, the estimator models present also a reduced computational complexity and then the possibility to be applied in real-time.

Conclusions

A non-invasive temperature estimation model, based on soft-computing technique, was proposed for a three-layered phantom. The best-achieved estimator models presented an appropriate error performance regardless of the spatial point considered (inside or at the interface of the layers) and of the intensity applied. Other methodologies published so far, estimate temperature only in homogeneous media. The main drawback of the proposed methodology is the necessity of a-priory knowledge of the temperature behavior. Data used for training and optimisation should be representative, i.e., they should cover all possible physical situations of the estimation environment.  相似文献   

12.

Purpose

The goal of this work was to develop a fast 3D chemical shift imaging technique for the noninvasive measurement of hyperpolarized 13C-labeled substrates and metabolic products at low concentration.

Materials and Methods

Multiple echo 3D balanced steady state magnetic resonance imaging (ME-3DbSSFP) was performed in vitro on a syringe containing hyperpolarized [1,3,3-2H3; 1-13C]2-hydroxyethylpropionate (HEP) adjacent to a 13C-enriched acetate phantom, and in vivo on a rat before and after intravenous injection of hyperpolarized HEP at 1.5 T. Chemical shift images of the hyperpolarized HEP were derived from the multiple echo data by Fourier transformation along the echoes on a voxel by voxel basis for each slice of the 3D data set.

Results

ME-3DbSSFP imaging was able to provide chemical shift images of hyperpolarized HEP in vitro, and in a rat with isotropic 7-mm spatial resolution, 93 Hz spectral resolution and 16-s temporal resolution for a period greater than 45 s.

Conclusion

Multiple echo 3D bSSFP imaging can provide chemical shift images of hyperpolarized 13C-labeled compounds in vivo with relatively high spatial resolution and moderate spectral resolution. The increased signal-to-noise ratio of this 3D technique will enable the detection of hyperpolarized 13C-labeled metabolites at lower concentrations as compared to a 2D technique.  相似文献   

13.
Chen JJ  Chen JJ  Chiang CS  Hong JH  Yeh CK 《Ultrasonics》2011,51(8):925-931

Objective

The blood flow rate in the microcirculation associated with angiogenesis plays an important role in the progression and treatment of cancer. Since the microvascular status of tumor vessels can yield useful clinical information, assessing changes in the tumor microcirculation could be particularly helpful for tumor evaluation and treatment planning.

Methods

In this study we used a self-developed 25-MHz ultrasound imaging system with a spatial resolution of 150 μm for assessing tumor-microcirculation development and the pattern of the vasculature in three tumor-bearing mice in vivo based on power Doppler images. The total Doppler power (DP) and color pixel density (CPD) revealed the presence of functional vessels distributed throughout a tumor volume. The vasculature distributions in the core and periphery were compared to the regulation of vasculature function, which facilitated determination of when the tumor grew rapidly.

Results

The data obtained from a quantified analysis of power Doppler images indicated that the tumor vascularity initially increased throughout the tumor. Both DP and CPD increased rapidly in the tumor periphery when the tumor volume exceeded 10 mm3.

Conclusion

Our preclinical findings suggest that power Doppler imaging could be useful for detecting the changes in tumor vascular perfusion and for determining the optimal treatment timing when a tumor begins its rapid volumetric growth.  相似文献   

14.
We describe and apply a scheme to obtain nuclear magnetic resonance (NMR) signals from multiple regions in space with a single pulse sequence in systems with strong, usually unavoidable, gradient magnetic fields. This is accomplished with multiple frequency irradiation and reception. Applications described include dual-slice NMR of a fluid to enhance S/N, T 2 measurements of two different samples, and efficient T 1 measurement sequence by interleaving shorter delays within a longer delay for different slices.  相似文献   

15.

Purpose

The purpose of the study was to evaluate the value of high-resolution three-dimensional fast imaging employing steady-state acquisition (3D FIESTA) imaging in the visualization of neurovascular relationship in patients with trigeminal neuralgia (TN).

Methods

Thirty-seven patients with unilateral typical TN underwent 3D FIESTA imaging. Neurovascular relationship at the trigeminal root entry zone was reviewed by an experienced neuroradiologist, who was blinded to the clinical details. The imaging results were compared with the operative findings in all patients.

Results

In 37 patients with TN, 3D FIESTA imaging identified surgically verified neurovascular contact in 35 of 36 symptomatic nerves. Based on surgical findings, the sensitivity and specificity of magnetic resonance (MR) imaging were 97.2% and 100%, respectively. Agreement between the position (medial, lateral, superior and inferior) of the compressing vessel relative to the trigeminal nerve identified by MR imaging and surgery was excellent (K=0.81; 95% confidence interval, 0.56–1.00). A statistically significant difference was found between the site of neurovascular contact and the clinical symptom related to the trigeminal branch (Fisher's Exact Test, P<.001).

Conclusions

Use of 3D FIESTA sequence enables accurate visualization of neurovascular contact in patients with TN. Anatomic relationships defined by this method can be useful in surgical planning and predicting surgical findings.  相似文献   

16.
The temperature dependent quantum efficiency of fluorescent dyes can be used to measure changes in temperature of the fluorescent dye molecules. This paper describes the use of Rhodamine dye as a temperature sensitive based fluorescence indicator for the characterization of heating in a pressure driven microfluidic device with high spatial resolution. A microheating element is used to control the temperature of the fluid in order to create localized heating in the microchannel. The temperature dependent fluorescence intensity of Rhodamine 6G for a concentration of is characterized with a 5th order polynomial then used to detect the temperature of the fluid in a microchannel. Fluid temperatures in the range of 20– are measured with an uncertainty of using a confocal fluorescence microscope. This method enables the characterization, imaging and mapping of three-dimensional temperature gradients within a microchannel.  相似文献   

17.

Objectives

A patient with a breast tissue expander may require a diagnostic assessment using magnetic resonance imaging (MRI). To ensure patient safety, this type of implant must undergo in vitro MRI testing using proper techniques. Therefore, this investigation evaluated MRI issues (i.e., magnetic field interactions, heating, and artifacts) at 3-Tesla for a breast tissue expander with a remote port.

Methods

A breast tissue expander with a remote port (Integra Breast Tissue Expander, Model 3612-06 with Standard Remote Port, PMT Corporation, Chanhassen, MN) underwent evaluation for magnetic field interactions (translational attraction and torque), MRI-related heating, and artifacts using standardized techniques. Heating was evaluated by placing the implant in a gelled-saline-filled phantom and MRI was performed using a transmit/receive RF body coil at an MR system reported, whole body averaged specific absorption rate of 2.9-W/kg. Artifacts were characterized using T1-weighted and GRE pulse sequences.

Results

Magnetic field interactions were not substantial and, thus, will not pose a hazard to a patient in a 3-Tesla or less MRI environment. The highest temperature rise was 1.7 °C, which is physiologically inconsequential. Artifacts were large in relation to the remote port and metal connector of the implant but will only present problems if the MR imaging area of interest is where these components are located.

Conclusions

A patient with this breast tissue expander with a remote port may safely undergo MRI at 3-Tesla or less under the conditions used for this investigation. These findings are the first reported at 3-Tesla for a tissue expander.  相似文献   

18.

Purpose

Proton magnetic resonance spectroscopy without water suppression is possible but is hampered by the presence of sideband artifacts. The aim of this study was to develop a chemical shift imaging method without water suppression for clinical routine with reduced sideband artifacts.

Materials and Methods

Spectra from ten healthy volunteers were acquired using a 3T (TimTrio, Siemens, Erlagen, Germany) scanner with a Point RESolved Spectroscopy sequence for volume selection. Postprocessing was performed in three steps: correcting the water peak position in all spectra (chemical shift correction), subtracting the Gaussian convolution of all free induction decay signals (FIDs) (water signal reduction), and subtracting the FID of a water phantom from the volunteer's FID signal (reduction of sidebands). For the postprocessing customized software was developed with Matlab 2007b.

Results

The described technique provides spectra with reduced water signal and sidebands. Quantitative analysis showed that there is a good agreement between spectra obtained with water suppressing radiofrequency pulses and the new method. Moreover, spectra obtained with the new method do not need phase correction.

Conclusion

The new method offers sufficient reduction of the water peak and sidebands. Its simplicity allows its use in clinical applications.  相似文献   

19.

Objective

Diffusion imaging techniques such as DTI and HARDI are difficult to implement in infants because of their sensitivity to subject motion. A short acquisition time is generally preferred, at the expense of spatial resolution and signal-to-noise ratio. Before estimating the local diffusion model, most pre-processing techniques only register diffusion-weighted volumes, without correcting for intra-slice artifacts due to motion or technical problems. Here, we propose a fully automated strategy, which takes advantage of a high orientation number and is based on spherical-harmonics decomposition of the diffusion signal.

Material and methods

The correction strategy is based on two successive steps: 1) automated detection and resampling of corrupted slices; 2) correction for eddy current distortions and realignment of misregistered volumes. It was tested on DTI data from adults and non-sedated healthy infants.

Results

The methodology was validated through simulated motions applied to an uncorrupted dataset and through comparisons with an unmoved reference. Second, we showed that the correction applied to an infant group enabled to improve DTI maps and to increase the reliability of DTI quantification in the immature cortico-spinal tract.

Conclusion

This automated strategy performed reliably on DTI datasets and can be applied to spherical single- and multiple-shell diffusion imaging.  相似文献   

20.

Objectives/Hypotheses

Singers learn to produce well-controlled tone onsets by accurate synchronization of glottal adduction and buildup of subglottal pressure. Spectrographic analyses have shown that the higher spectrum partials are present also at the vowel onset in classically trained singers’ performances. Such partials are produced by a sharp discontinuity in the waveform of the transglottal airflow, presumably produced by vocal fold collision.

Study Design

After hearing a prompt series of a triad pattern, six singer subjects sang the same triad pattern on the vowel /i/ (1) preceded by an aspirated /p/, (2) preceded by an unaspirated /p/, and (3) without any preceding consonant in staccato.

Methods

Using high-speed imaging we examined the initiation of vocal fold vibration in aspirated and unaspirated productions of the consonant /p/ as well as in the staccato tones.

Results

The number vibrations failing to produce vocal fold collision were significantly higher in the aspirated /p/ than in the unaspirated /p/ and in the staccato tones. High frequency ripple in the audio waveform was significantly delayed in the aspirated /p/.

Conclusions

Initiation of vocal fold collision and the appearance of high-frequency ripple in the vowel /i/ are slightly delayed in aspirated productions of a preceding consonant /p/.  相似文献   