首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Paul RL 《The Analyst》2005,130(1):99-103
An instrument for cold neutron prompt gamma-ray activation analysis (PGAA), located at the NIST Center for Neutron Research (NCNR), has proven useful for the measurement of boron in a variety of materials. Neutrons, moderated by passage through liquid hydrogen at 20 K, pass through a (58)Ni coated guide to the PGAA station in the cold neutron guide hall of the NCNR. The thermal equivalent neutron fluence rate at the sample position is 9 x 10(8) cm(-2) s(-1). Prompt gamma rays are measured by a cadmium- and lead-shielded high-purity germanium detector. The instrument has been used to measure boron mass fractions in minerals, in NIST SRM 2175 (Refractory Alloy MP-35-N) for certification of boron, and most recently in semiconductor-grade silicon. The limit of detection for boron in many materials is <10 ng g(-1).  相似文献   

2.
Major levels of boron in borosilicate glasses have been determined nondestructively by neutron activation analysis. In contrast to chemical methods for determining boron as a major component, the described nuclear method has few interferences and does not require chemical separation of boron prior to its quantitation. The effects of neutron self-shielding by boron (1 to 8% by weight) are examined, minimized by dilution of powdered samples with high purity graphite, and circumvented by comparative analyses. Results of the analysis of a series of glasses with increasing boron composition are 1.150±.005% and 7.766±.035% for the low and high members of the series. Accuracy of these results depends upon comparative analyses with the certified Standard Reference Material, SRM 93a (3.89±0.02% B). Once analyzed, the glasses are useful as secondary standards for alpha track counting, and also ion and electron microprobe analyses of glasses.  相似文献   

3.
Paul RL 《The Analyst》2001,126(2):217-221
An instrument for cold neutron prompt gamma-ray activation analysis (CNPGAA) has been used for the nondestructive determination of nitrogen. The samples were analyzed in an evacuated box to minimize background from neutron capture by atmospheric nitrogen. The system features lower background and lower detection limits than obtainable with the University of Maryland-National Institute of Standards and Technology (NIST) thermal neutron PGAA instrument. CNPGAA has been used to measure nitrogen in standard reference materials which included biological materials and soils; the results are in agreement with certified values. The detection limit for nitrogen in most biological and geological samples is near 1000 mg kg-1.  相似文献   

4.
Prompt gamma-ray neutron activation analysis (PGNAA) using the internal mono-standard method was tested for its applicability to analyzing large solid samples including irregularly shaped meteorite samples. For evaluating the accuracy and precision of the method, large quantities of the Geological Survey of Japan standardized rock powders (JB-1a, JG-1a, and JP-1) were analyzed and 12 elements (B, Na, Mg, Al, Cl, K, Ca, Ti, Mn, Fe, Sm, and Gd) were determined by using Si as an internal standard element. Analytical results were mostly in agreement with literature values within 10 %. The precision of the method was also shown to be within 10 % (1σ) for most of these elements. The analytical procedure was then applied to four stony meteorites (Allende, Kimble County, Leedey, Lake Labyrinth) and four iron meteorites (Canyon Diablo, Toluca (Mexico), Toluca (Xiquipilco), Squaw Creek) consisting of large chunks or single slabs. For stony meteorites, major elements (Mg, Al, Si, S, Ca, and Ni), minor elements (Na and Mn) and trace element (B, Cl, K, Ti, Co, and Sm) were determined with adequate accuracy. For iron meteorites, results for the Co and Ni mass fractions determined are all consistent with corresponding literature values. After the analysis, it was confirmed that the residual radioactivity remaining in the sample after PGNAA was very low and decreased down to the background level. This study shows that PGNAA with the internal mono-standard method is highly practical for determining the elemental composition of large, irregularly shaped solid samples including meteorites.  相似文献   

5.
We present chemometric study to identify the provenance of agricultural product, beef. Combination of instrumental neutron activation analysis (INAA) and prompt gamma-ray analysis (k 0-PGA) were performed to determine 10 elements, C, H, N, S, Sm, Br, Mg, Na, K, Cl, nondestructively. We measured elemental profiles in beef samples produced from different districts in Japan, Australia and USA. In the case of PGA, k 0-method was employed to determine the elemental concentrations. There was a difference in elemental profiles between Japanese black cattle beef and that produced in USA through principal component analysis (PCA). However, Holstein beef of Japan and that of Australia was not sufficiently grouped by the PCA modeling with the elemental data set. This is the first study to identify the provenance of beef through elemental analysis.  相似文献   

6.
A new instrument for cold neutron prompt gamma-ray activation analysis (CNPGAA) is being designed and constructed at the NIST Center for Neutron Research (NCNR). The new instrument is expected to have lower gamma-ray and neutron background and better detection limits for most elements than the current cold neutron PGAA instrument. Other advantages over the current facility will include the ability to analyze larger samples and greater overall measurement capability due to the addition of scanning stages, cryostats, and sample changers.  相似文献   

7.
An accurate and efficient analytical method using neutron-induced prompt γ-ray was developed for the determination of boron contents in volcanic rocks. We corrected the effect of sample geometry and flux fluctuation by using silicon as an internal standard. However, we found that the slopes of the calibration line vary among volcanic samples with different matrix. Because the increase of boron activity correlates positively with γ-ray count rate of hydrogen (water), we call this as the hydrogen effect. The hydrogen effect was confirmed by our experiment in which the boron activities showed systematic increase with the amount of added hydrogen (water). Most volcanic rocks, however, contain little water (<2 wt.%) to show this effect. We determined boron contents in various volcanic rocks in order to confirm the validity of the procedure that we established. The analyzed boron contents agreed well with the previous reported values. For efficient PGA of boron in volcanic rocks, we recommend JB-2 (GSJ standard rock) as a single geochemical standard, because of its high boron content (31.2 ppm).  相似文献   

8.
Summary The thermal neutron prompt gamma-ray activation analysis (PGAA) facility, operated by the US Food and Drug Administration and National Institute of Standards and Technology Center for Neutron Research, has been redesigned to lower background radiation levels and improved analytical capabilities. Analysis of 22 element standards and food and botanical certified reference materials revealed significant sensitivity increases and lower limits of detection for H, B, C, N, Na, Al, P, S, Cl, K, Ca, Fe, and Cd. Mass fractions for these elements, as well as Mg, Al, Si, Ti, Mn, Fe, Cu, I, Zn, Sm, and Gd, were determined for 6 dietary supplements.  相似文献   

9.
In this study an investigation into the applicability of the absolute method in Prompt Gamma-ray Neutron Activation Analysis (PGNAA) was undertaken. Although the system parameters are adequately characterized, the scatter in nuclear data for a number of elements is significant. For our particular experimental set up the K-factors were calculated for a number of elements using both Au and Fe as monostandards. A comparison was made between the calculated and experimentally determined K-factors and from this comparison the feasibility of the absolute method in neutron prompt gamma-rays can be realized for a number of elements.  相似文献   

10.
A prompt-gamma neutron activation technique has been developed using the (n, ) apparatus situated at the O degree through-tube of the Imperial College CONSORT II Reactor with a thermal neutron flux at the target position of approximately 2×106 n cm–2 sec–1, and a Compton-suppression system involving a lithium-drifted germanium (Ge(Li)) detector and a sodium iodide anti-Compton shield. Boron levels of 1–5 g g–1 (detection limit 0.05 g B for 10,000 sec period of measurement) can be attained using the Compton-suppression system with graphical inter-polation correction for the 472 keV sodium-ray peak contribution to the Doppler-broadened 478 keV boron gamma-ray peak resulting from the10B(n, )7Li reaction. Very good agreement is reached for boron levels compared using this system for various Standard Reference Materials and other published values. Measurement of the boron content of bone and tooth samples from rheumatoid arthritis individuals shows lower levels, (p<0.05); 16.13±7.53 g g–1, when compared with a control population; 19.79±4.18 g g–1. A positive correlation existed between the boron content of bone and tooth material for each study group. Results indicate that boron availability may be associated with rheumatoid arthritis.  相似文献   

11.
A facility for the irradiation of internal targets has been installed at the research reactor FRG-of the GKSS Research Center. Thermal-neutron induced prompt gamma radiation was detected by pair spectrometer. With this experimental arrangement concentrations of the major and mino elements Na, Al, Si, K, Ca, Ti, Mn, Fe, Zn, Cl, and S, as well as of the trace constituents Cr Ni, Cu Cd, and Hg of samples from a sediment core of the Elbe River could be determined. The results indicate, that prompt gamma-ray neutron activation analysis (PGNAA) is a powerful instrumental tool for a complete characterization of the main sediment constituents and for the detection of the trace elements Cd and Hg which are of considerable ecological relevance.  相似文献   

12.
The method of multiple γ-ray peak ratio determination has been applied to the nondestructive neutron activation analysis of uranium in rocks and ores. The photopeaks of239Np gamma-rays produced by the activation of238U and those of the fission products of235U are a measure of the quantity of uranium in the irradiated sample, provided that the uranium is of natural isotopic composition. The ratios between the integrated areas of the different photopeaks are calculated and compared with those obtained for a uranium standard. The uranium concentration in the sample is calculated from the photopeaks whose ratios correspond, within the error limits to those of pure natural uranium. High accuracy better than ±2% has been obtained.  相似文献   

13.
Analytical bias due to neutron scattering and absorption in cold neutron prompt gamma-ray activation analysis (CNPGAA) is largely eliminated for homogeneous samples when element ratios are measured. Application of sensitivity ratios (measured relative to titanium) to the multielement analysis of the Allende meteorite increases both the speed and accuracy of the measurement. Greater measurement accuracy is achieved for some samples when ratios of element concentrations are reported. Problems are encountered when applying the ratio method to measurement of elements which deviate from 1/v behavior, and when gamma-ray attenuation or sample heterogeneity are significant.  相似文献   

14.
15.
16.
A low cost neutron capture prompt gamma activation analysis facility has been constructed at The University of Michigan's Pheonix Memorial Laboratory. Although the neutron beam used has a fairly large epithermal component (Cd ratio 7.1), background levels are low enough to result in satisfactory measurement of over 16 different elements. For the elements of greatest sensitivity (samarium, boron, gadolinium, and cadmium) minimum detectable levels of 3.6·10−5 to 1.4·10−5 gram for a one hour measurement are possible. The fast neutrons incident to the detector were found to be minimal. Estimates of up to 3 years of continuous operation before measurable damage is expected.  相似文献   

17.
Neutron induced prompt -ray analysis (PGA) and instrumental neutron activation analysis (INAA) have been applied to the sediments collected from the Tama River estuary in Tokyo, Japan. The vertical distribution of 24 elements in the sediments was determined and the factors goveming the vertical profiles have been discussed. Major elements are distributed depending on weathering that proceeds much with increasing depth. Cadmium is highly concentrated in the deeper layer where sulphate ion is reduced to hydrogen sulphide. The distribution of several rare earth elements is also presented  相似文献   

18.
Neutron induced prompt gamma-ray analysis (PGA) and instrumental neutron activation analysis (INAA) have been applied to the sediments collected from the Yasaka River estuary in Oita Prefecture, Japan. The vertical distribution of 33 elements in the sediments has been determined and compared with that in more polluted estuarine sediments. While the S content increased with increasing depth because of a sulphide accumulation under reducing condition, the increase in sulphide-forming elements such as Ag, Cd, Co and Zn was not observed in the deeper section of the Yasaka River estuarine sediments.  相似文献   

19.
The restart of the recently upgraded research reactor in Budapest is foreseen at the end of this year. A number of fast, thermal and cold neutron beams will serve for research, industrial and educational activities. One of the cold neutron guide end positions will be utilized for neutron capture prompt gamma-ray activation analysis (PGAA). Further development of the PGAA method as well as new applications in environmental research, biology and medicine are planned.  相似文献   

20.
The k 0-standardization method has been applied and evaluated at the cold-neutron prompt gamma-ray activation (PGA) facility of the Swiss spallation source SINQ (Paul Scherrer Institute). The k 0-factors for 26 elements of interest were measured using chlorine as a comparator. The results showed good agreement with the values determined at other cold and thermal neutron guided beams, except for a few elements. Then, standard reference materials were analyzed to assess the accuracy of the method using the obtained k 0-factors. Finally, the technique was used for multielement determination in various samples coming from nuclear waste storage, geochemistry and geology. In addition, the non-destructive nature of PGAA offered an interesting application in archeology.  相似文献   