共查询到20条相似文献,搜索用时 15 毫秒
1.
The concept of multi-commutation in flow analysis is revisited, and emphasis is given to recent methodological and applicative achievements. Multi-commutation is compatible with different flow patterns (unsegmented, segmented, pulsed, tandem) and amenable to concentration-oriented feedback mechanisms. Its exploitation has led to significant attainments mainly in relation to versatility of the flow system. Characteristics and potentialities of the multi-commuted flow systems are discussed, and guidelines for assisting methodological implementation are given.The number of applications has experienced remarkable increase during last years; therefore, the applicative part of this review is focused on the recent noteworthy applications, mainly in relation to environmental, agronomical, pharmaceutical, biological, food and industrial samples. 相似文献
2.
Jason W Costin 《Analytica chimica acta》2003,480(1):67-77
The determination of the amino acids proline, histidine, tyrosine, arginine, phenylalanine and tryptophan using flow injection analysis (FIA) with chemiluminescence detection is described. Proline was the only amino acid to exhibit chemiluminescence with the tris(2,2-bipyridyl)ruthenium(III) reaction at pH 10. While, histidine was found to selectively enhance the reaction of luminol with Mn(II) salts in a basic medium. Acidic potassium permanganate chemiluminescence was able to selectively determine tyrosine at pH 6.75. Low pressure separations using a C18 guard column allowed the simultaneous determination of tyrosine and tryptophan or phenylalanine and tryptophan with acidic potassium permanganate and copper(II)-amino acid-hydrogen peroxide chemiluminescence, respectively. Precision for each method was less than 3.9% (R.S.D.) for five replicates of a standard (1×10−5 M) and the detection limits ranged between 4×10−9 and 7×10−6 M. Preliminary investigations revealed that the methodology developed was able to selectively determine the individual amino acids in an equimolar mixture of the 20 naturally occurring amino acids. 相似文献
3.
A simple, rapid and sensitive method for the determination of psilocin and psilocybin is described. This is the first report on the determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence. The limits of detection (signal-to-noise ratio = 3) are 9 × 10−10 M and 3 × 10−10 M for psilocin and psilocybin, respectively.A concise synthetic route for psilocin in three steps from readily available starting materials is also described. The structures were elucidated on the basis of spectroscopic data. 相似文献
4.
Marek Trojanowicz 《Analytica chimica acta》2009,653(1):36-58
Recent years have provided numerous new examples of applying flow-through electrochemical detectors in chemical analysis. This review, based on about 250 original research papers cited from the current analytical literature, presents their application in flow analysis and capillary electrophoretic methods. Example applications are also given for arrays of electrochemical sensors in flow analysis and electrochemical detection in microfluidic systems. Potentiometric detection with ion-selective electrodes predominates in flow analysis carried out mostly in a flow-injection system, while amperometric and conductivity detections are most commonly employed in capillary electrophoresis. 相似文献
5.
Shu-Hui Lin Kai-Chieh Chang Yu-Chun Chen Tiing Yu Su-Cheng Pai 《Journal of chromatography. A》2009,1216(21):4618-4624
In addition to the Poiseuille effect, a so-called temporal effect was proposed recently to elucidate the commonly observed tailing peak signals of flow injection analysis (FIA). A multi-channel absorbance detector was used in this study to obtain the FIA peaks on both the spatial and temporal coordinates. The temporal effect was analyzed by comparison of the profiles between the experimental and the corresponding Gaussian peaks, and by comparison of asymmetry factors between the spatial and the temporal peaks. The temporal effect appeared to be the major factor under flow rates ranging from 0.5 to 8 ml min−1. This was despite the presence of a spatially frontal peak observed in the FIA tubing, which was found to result in a tailing peak on the temporal coordinate due to this discussed cause. In addition, the temporal effect became greater as the flow rate increased. 相似文献
6.
The limits of detection (3s) for ascorbic acid were 5×10−8 M with acidic potassium permanganate using both flow injection analysis (FIA) and sequential injection analysis (SIA) whereas the soluble manganese(IV) afforded 1×10−8 M and 5×10−9 M for FIA and SIA, respectively. Determinations of ascorbic acid in Vitamin C tablets were achieved with minimal sample pretreatment using a standard additions calibration and gave good agreement with those of iodimetric titration. 相似文献
7.
A novel chemiluminescence gas-diffusion flow injection system for the determination of arsenic(III) in aqueous samples is described. The analytical procedure involves injection of arsenic(III) samples and standards into a 0.3 mol L−1 hydrochloric acid carrier stream which is merged with a reagent stream containing 0.2% (w/v) sodium borohydride and 0.015 mol L−1 sodium hydroxide. Arsine, generated in the combined carrier/reagent donor stream, diffuses across the hydrophobic Teflon membrane of the gas-diffusion cell into an argon acceptor stream and then reacts with ozone in the flow-through chemiluminescence measuring cell of the flow system. Under optimal conditions, the method is characterized by a wide linear calibration range from 0.6 μg L−1 to 25 mg L−1, a detection limit of 0.6 μg L−1 and a sample throughput of 300 samples per hour at 25 mg L−1 and 450 samples per hour at 25 μg L−1. 相似文献
8.
Photochemical conversions are cost-effective and environmental friendly processes that require mild experimental conditions and avoid generation of highly acidic wastes. Treated samples are then compatible with most of the analytical techniques. These characteristics become more relevant when the photoconversions are accomplished to flow analysis, thus allowing exploitation of incomplete reactions, the effective use of the photogenerated unstable radicals and in-line sample treatment. Decreasing of reagent consumption and waste generation, sample processing in a closed environment, and improvement of efficiency of the photochemical processes are other inherent advantages. These aspects are critically reviewed in this article, which emphasizes applications to fractionation and speciation analysis, photo-induced luminescence, miniaturization, and in-line waste treatment. Design of flow-through photochemical cells, use of auxiliary reagents in homogeneous and heterogeneous media, and configurations of flow manifolds are also discussed. 相似文献
9.
O. Hernndez F. Jimnez A. I. Jimnez J. J. Arias J. Havel 《Analytica chimica acta》1996,320(2-3):177-183
Flow injection analysis (FIA) with multiwavelength scanning of the FIA peaks using a diode array detector (DAD) has been combined with a multivariate calibration approach applying the partial least squares (PLS) method for the data evaluation. In this way, various side effects like dilution of the reagent, high blank, absorbance changes due to the pH gradient throughout the peak and/or the other interferences can be accounted for. Thus, even with a simple FIA manifold instrumentation the satisfactory results of multicomponent analysis are obtained. The method described has been checked on analysis of binary (Ca and Mg) and ternary (Ca, Mg and Cu) mixtures with pyridylazo resorcinol (PAR) as reagent and applied for rapid determination of calcium and magnesium in dialysis liquids and waters. 相似文献
10.
A state-of-the-art overview of molecular spectroscopy as applied in flow injection analysis (FIA) is presented. It deals chiefly with the most interesting FIA approaches aimed at improving detector performance, innovations in the detection system itself and the coupling of FIA with unusual detectors for this technique. The most salient trends in relation to this association are also commented upon. 相似文献
11.
Gallignani M Valero M Ayala C Del Rosario Brunetto M Sánchez A Burguera JL Burguera M 《Talanta》2004,64(5):1290-1298
In this work, the coupling between flow analysis (FA)–vapor phase generation (VPG) and Fourier transform infrared spectrometry (FTIR) has been proposed as a novel and alternative strategy for the determination of nitrite. The analyte was transformed into the gaseous nitric oxide (NO) by on-line reaction with potassium iodide (KI) or ascorbic acid in acidic medium. The gaseous NO generated was transported by means of a N2 gas carrier stream inside the IR gas cell and the corresponding FTIR spectrum was acquired in a continuous mode. The absorbance at 1876 cm−1, corrected by a baseline established between 1879 and 1872 cm−1 at a nominal resolution of 2 cm−1, was selected as a measurement criterion. The effect of different spectroscopic and flow analysis experimental parameters, such as nominal resolution, number of scans, reducing agent and its concentration, acidic medium, reagents and sample flow rates, and the carrier gas flow rate on the analytical signal, and then in the figures of merit were initially evaluated by using a standard short path length (10 cm) IR gas cell. The optimization of the system was carried out by the univariate method. The main aims of this study were: (i) to investigate the on-line generation of gaseous nitric oxide in a continuous flow system, and (ii) the use of Fourier transform infrared spectrometry as an alternative and selective detector for the determination of nitrite. The proposed method was initially tested and applied for the determination of nitrite in samples with very high concentration of nitrite, such as frankfurters. 相似文献
12.
A simple, rapid flow injection chemiluminescence (FI-CL) method has been developed for selective determination of acenaphthylene (ACY), based on the CL produced in the reaction of tris(2,2′-bipyridine)ruthenium(III) (Ru(bipy)33+) and ACY in an acidic buffer solution. Under the optimum experimental conditions, the calibration curve was linear over the range 5.0 × 10−3 to 4.0 × 10−7 mol L−1 for ACY. The detection limit (S/N = 3) was 2.0 × 10−7 mol L−1 and the relative standard deviation of 10 replicate measurements was 2.3% for 5.0 × 10−5 mol L−1 of ACY. Selectivity of CL reaction of ACY from other 15 polycyclic aromatic hydrocarbons (PAHs) was investigated by flow injection method. The method was applied to determine the ACY content in soil. 相似文献
13.
Diego Vendramini 《Analytica chimica acta》2006,570(1):124-128
A novel strategy for implementing differential reaction-rate methods in flow-injection analysis is proposed and applied to the determination of copper and nickel in plant digests using 2-(5-brom-2-pyridylazo)-5-(diethylamino)-phenol (Br-PADAP) as the color-forming reagent. Multi-site detection is involved, therefore the flow cell is displaced between two monitoring sites, and the analytical signals refer to different conditions of sample dispersion, reaction development and timing.The system handles 20 samples h−1 and requires 0.32 mg Br-PADAP per determination. Signal additivity was evaluated within 98 and 102%, and linear responses (r > 0.999; n = 6) were verified for both copper and nickel up to 0.80 mg l−1. Detection limits of 0.01 and 0.04 mg l−1 Cu and Ni were estimated by considering the highest concentration of the counter analyte. Results are precise (R.S.D. < 2%) and in agreement with ICP-OES (95% confidence level). Potentialities and limitations of the approach are discussed. 相似文献
14.
Peter S. Ellis 《Talanta》2009,79(3):830-919
A total internal reflection (TIR) flow-through cell that is highly tolerant of schlieren effects, has limited hydrodynamic dispersion and does not trap gas bubbles, and which is suitable for sensitive photometric measurements in flow analysis, is described. Light from an optical fibre is introduced into a short length of quartz capillary through the sidewall at an incident angle of ca. 53°. Under this condition, incident light undergoes total internal reflection from the external air-quartz interface and is propagated by successive reflections from the external walls through the aqueous liquid core of the cell. Detection of the transmitted beam is enabled by intentionally introducing an optical coupling medium at a predetermined distance along the capillary wall, which allows the internally reflected light to be captured by a second optical fibre connected to a charge-couple device detector.This configuration embodies a number of the desirable features of a liquid core waveguide cell (i.e. total internal reflection), a multi-reflection (MR) flow cell (i.e. minimum susceptibility to schlieren effects, low hydrodynamic dispersion and little tendency to trap bubbles), and a conventional Z-cell (wide dynamic range). When employed with a flow injection system, a limit of detection of 2.0 μg PL−1 was achieved for the determination of reactive phosphate using the TIR cell, compared with LOD values of 3.8 μg PL−1 and 4.9 μg PL−1 obtained using the MR and Z-cells with same manifold.The combined advantages of schlieren-tolerance and lack of bubble entrapment of the MR cell with the higher S/N ratio and wider dynamic range of a conventional Z-cell, make the TIR cell eminently useful for photometric measurements of samples with widely differing refractive indices. 相似文献
15.
A flow injection with pulsed amperometric detection for determination of doxycycline or chlortetracycline in pharmaceutical formulations is described. Doxycycline or chlortetracycline were studied at a gold rotating disk electrode with cyclic voltammetry as a function of pH of supporting electrolyte solution. The optimized PAD waveform parameters were obtained with a flow injection system. The optimized pulsed conditions of doxycycline were 1150 mV (versus Ag/AgCl reference electrode) detection potential (Edet) for 220 ms (150 ms delay time and 70 ms integration time), 1500 mV (versus Ag/AgCl reference electrode) oxidation potential (Eoxd) for 70 ms oxidation time (toxd) and 250 mV (versus Ag/AgCl reference electrode) reduction potentail (Ered) for 400 ms reactivation time (tred). The optimized pulsed conditions of chlortetracycline were 1050 mV (versus Ag/AgCl reference electrode) detection potential (Edet) for 300 ms (200 ms delay time and 100 ms integration time), 1300 mV (versus Ag/AgCl reference electrode) oxidation potential (Eoxd) for 70 ms oxidation time (toxd) and 250 mV (versus Ag/AgCl reference electrode) reduction potentail (Ered) for 400 ms reactivation time (tred). The optimized PAD waveform was applied to the determination of doxycycline hydrochloride and chlortetracycline hydrochloride standard solution and in pharmaceutical formulations. The linear dynamic ranges of doxycycline hydrochloride and chlortetracycline hydrochloride were 1 μM–0.1 mM. The sensitivity of this method was found to be 23 μA/mM for doxycycline hydrochloride and 33.76 μA/mM for chlortetracycline hydrochloride. The detection limit for both compounds is 1 μM. The doxycycline hydrochloride and chlortetracycline hydrochloride content in commercially available tablet dosage forms by the proposed method was comparable to those specified by the manufacturer. 相似文献
16.
A new methodology for the determination of sucrose in complex aqueous matrices by flow injection analysis with FTIR detection is presented. The methodology based on the enzymatic hydrolytic cleavage of sucrose by means of invertase to -D-glucose and -D-fructose. A special manifold consisting of two internally coupled injection valves being switched simultaneously is applied to facilitate recording FTIR spectra of the sample before and after the enzymatic reaction. The analytical readout is taken from the resulting difference spectrum obtained by subtracting the FTIR spectra of the sample before and after the reaction. The developed methodology uses a GC-IR software to continuously record the FTIR spectra of the effluent from the manifold. The proposed method gives linear results in the range of 10 to 100 mmol/l and has been successfully applied to the analysis of sucrose in synthetic mixtures as well as in real samples such as soft drinks. 相似文献
17.
In this work, a simple strategy for the determination of ethanol in all types of alcoholic beverages using Fourier transform infrared spectrometric detection has been developed. The methodological proposal includes the quantitative on-line liquid-liquid extraction of ethanol with chloroform, through a sandwich type cell equipped with a PTFE membrane, using a two-channel manifold; and direct measurement of the analyte in the organic phase, by means of Fourier transform infrared spectrometry. The quantification was carried out measuring the ethanol absorbance at 877 cm−1, corrected by means of a baseline established between 844 and 929 cm−1. The procedure, which does not require any sample pretreatment (except for the simple degassing of beer and gassy wine samples, and a simple dilution of spirits with water), was applied to determine ethanol in different alcoholic beverages such as beers, wines and spirits. The results obtained highly agree with those obtained by a derivative FTIR spectrometric procedure, and by head space-gas chromatography with FID detection. The proposed method is simple, fast, precise and accurate. Moreover, it can be easily adapted to any infrared spectrometer equipped with a standard transmission IR cell, and provides attractive analytical features, which are comparable to, or better than those offered by other published methods. In consequence, it represents a valid alternative for the determination of ethanol in alcoholic beverages, and could be suitable for the routine control analysis. 相似文献
18.
Acetaminophenol or paracetamol is one of the most commonly used analgesics in pharmaceutical formulations. Acetaminophen is electroactive and voltammetric mechanistic studies for the electrode processes of the acetaminophenol/N-acetyl-p-quinoneimine redox system are presented. Carbon nanotubes modified screen-printed electrodes with enhanced electron transfer properties are used for the study of the electrochemical-chemical oxidation mechanism of paracetamol at pH 2.0.Quantitative analysis of paracetamol by using its oxidation process (in a Britton-Robinson buffer solution pH 10.0) at +0.20 V (vs. an Ag pseudoreference electrode) on an untreated screen-printed carbon electrode (SPCE) was carried out. Thus, a cyclic voltammetric based reproducible determination of acetaminophen (R.S.D., 2.2%) in the range 2.5 × 10−6 M to 1 × 10−3 M, was obtained. However, when SPCEs are used as amperometric detectors coupled to a flow injection analysis (FIA) system, the detection limit achieved for paracetamol was 1 × 10−7 M, one order of magnitude lower than that obtained by voltammetric analysis. The repeatability of the amperometric detection with the same SPCE is 2% for 15 successive injections of 10−5 M acetaminophen and do not present any memory effect.Finally, the applicability of using screen-printed carbon electrodes for the electrochemical detection of paracetamol (i.e. for quality control analysis) was demonstrated by using two commercial pharmaceutical products. 相似文献
19.
Jacqui L. AdcockAuthor Vitae Zoe M. SmithAuthor VitaeNeil W. BarnettAuthor Vitae Gregory J. BarbanteAuthor VitaeEgan H. DoevenAuthor Vitae Paul S. Francis 《Analytica chimica acta》2014
The application of ‘soluble’ (colloidal) manganese(IV) for chemiluminescence detection is reviewed, focussing on papers published since the last comprehensive review of the subject in 2008. Advances in this reagent system include: the on-line formation of manganese(IV); new insight into the light-producing pathway and selectivity of the reagent; its application to assess total antioxidants in plant derived samples and oxidative stress in biological fluids and tissues; and the replacement of the formaldehyde enhancer with ethanol. 相似文献
20.
Marieta L.C. Passos Paula C.A.G. Pinto João L.M. Santos M. Lúcia M.F.S. Saraiva André R.T.S. Araujo 《Analytica chimica acta》2015
Nanoparticles (NPs) exhibit a number of distinctive and entrancing properties that explain their ever increasing application in analytical chemistry, mainly as chemosensors, signaling tags, catalysts, analytical signal enhancers, reactive species generators, analyte recognition and scavenging/separation entities. 相似文献