1.
A method is described for the determination of 16 sulfonamides in honey. Samples are dissolved in phosphoric acid solution (pH2), cleaned up with 2 solid-phase extraction (SPE) cartridges, an aromatic sulfonic cation-exchange cartridge and an Oasis HLB SPE cartridge, and analyzed both qualitatively and quantitatively by liquid chromatography/tandem mass spectrometry (LC/MS/MS) under the selected conditions. Without exception, calibration curves were linear (r = > 0.995), when sulfamethizole was between 1.0 and 25.0 microg/kg; sulfacetamide, sulfapyridine, sulfadiazine, sulfachloropyridazine, sulfamethoxazole, sulfamerazine, sulfisoxazole, sulfamonomethoxine, and sulfadoxine were between 2.0 and 50.0 microg/kg; sulfamethoxypyridazine, sulfadimethoxine, and sulfathiazole were between 4.0 and 100.0 microg/kg; sulfamethazine and sulfameter were between 8.0 and 200.0 microg/kg; and sulfaphenazole was between 12.0 and 300.0 microg/kg. Average recoveries at 4 fortification levels in the range of 1.0-300 microg/kg in honey were 70.9-102.5%, and relative standard deviations were 2.02-11.52%. The limits of quantitation for the 16 sulfonamides were between 1.0 and 12.0 microg/kg, with the LC/MS/MS method.  相似文献   

2.
A straightforward and reliable method was developed for the determination of chlormequat in pears by liquid chromatography/mass spectrometry (LC/MS). Water and methanol were compared as extraction solvents. Because no significant differences in extraction efficiency or repeatability were found, water was chosen as the extraction solvent. The extracts were analyzed without cleanup by either an ion-trap liquid chromatograph/mass spectrometer in the single MS mode or a triple-quadrupole instrument in the MS/MS mode, using electrospray ionization. Both instruments were equally suitable for quantitation and confirmation of identity. Recoveries were 76-103%, and reproducibility was < or = 12%. The lowest detection limit (0.007 mg/kg) was obtained with the triple-quadrupole instrument in the MS/MS mode.  相似文献   

3.
A sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry; LC/MS/MS) method with on-line extraction and sample clean-up for the screening and confirmation of residues of sulfonamides in kidney is described. The sulfonamides are extracted from homogenized kidney with methanol. After centrifugation of the extract, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization (ESI) followed by multiple reaction monitoring. For each sulfonamide the collisional decomposition of the protonated molecule to a common, abundant fragment ion was monitored. The method has been validated for sulfadimethoxine, sulfaquinoxaline, sulfamethazine, sulfamerazine, sulfathiazole, sulfamethoxazole, sulfadiazine and sulfapyridine. Calibration curves resulting from spiked blank kidney samples at the 10-200 microg/kg level showed good linear correlation. At the level of 50, 100 and 200 microg/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 16%. The limits of detection (LODs) ranged from 5 to 13.5 microg/kg. The recoveries ranged from 78 to 82%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of sulfonamides in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

4.
A liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of residues of the anaesthetic tricaine mesilate (MS222) in fish tissues is described. Residues were extracted from homogenized tissues with McIllvaine buffer/methanol and purified over a C18 solid-phase extraction column followed by LC-MS/MS analysis. In the multiple-reaction monitoring mode of the mass spectrometer, chromatograms were recorded by monitoring the m/z 166-->m/z 138 and m/z 166-->m/z 94 transitions for quantification and confirmation of the residues in the finfish matrix, respectively. Recoveries were in the range of 67%+/-10% (n=6) for tilapia at 2 microg kg(-1), 95%+/-7% (n=6) at 2 microg kg(-1) in salmon and 92%+/-3% (n=5) for trout at 2.5 microg kg(-1). The limits of detection were 0.5, 0.6 and 0.6 microg kg(-1) in trout, salmon and tilapia, respectively. No residues of tricaine were found in eight sampled aquacultured fish (salmon and trout) bought from the local market.  相似文献   

5.
An analytical method for screening, quantitation and confirmation of a group of 100 pesticides in vegetable and fruit samples was developed using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS). The pesticides studied belonged to different chemical families of herbicides, insecticides and fungicides; some degradation products were included as well. A thorough optimization was performed for each analyte to achieve individual optimum fragmentor and collision energy voltages. Two transitions per parent compound were monitored in a single chromatographic run containing two time segments. A small particle size C(18) column (1.8 microm) was used for the chromatographic separation of the mixture, providing very narrow peaks and allowing an excellent separation of all the analytes in a 30-min period for maximum peak capacity. The method was validated with blank matrices of green pepper, tomato and orange spiked from 0.1 to 100 microg/kg with the pesticide mix. Quantitation was carried out using matrix-matched standard calibration and linearity of response over 3 orders of magnitude was demonstrated (r > 0.99). Limits of detection based on two transitions and ion-ratio requirements ranged between 0.3 and 50 microg/kg. In general, the sensitivity obtained meets the maximum residue levels (MRLs) established by the European Union regulation for food monitoring programs. The analytical performance of the method was evaluated for different types of vegetables and fruits, showing little or no matrix effects, and examples of screening and confirmation of pesticides in these samples are shown here.  相似文献   

6.
A sensitive, specific, and reliable liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for detection and identification of zeranol in chicken or rabbit liver. A homogenized liver sample was hydrolyzed with beta-glucuronidase/arylsulfatase, and the hydrolysate was extracted with ethyl ether. The supernatant was evaporated to dryness, and the residue was dissolved in chloroform and re-extracted with sodium hydroxide. After acidification, the extract was cleaned up on a C18 solid-phase extraction cartridge and analyzed by electrospray LC-MS/MS in the negative ion mode. The multiple reaction monitoring transition from both m/z 321 to 277 and m/z 321 to 303 was monitored for confirmation, and the product ion of 277 was used for quantitation. Separation was performed on a Waters XTettra C18 column (50 x 2.1 mm, 3.5 microm) combined with a safeguard column (Symmetry C18, 20 x 3.9 mm, 5 microm), using a gradient elution with acetonitrile and 20 mM ammonium acetate. Calibration curves were prepared and good linearity was achieved over the concentration ranges tested. For all liver samples fortified at 3 different levels of 1, 5, and 50 microg/kg, the overall recoveries and relative standard deviations were in the range of 61-90 and 8-13%, respectively. The limit of quantitation based on the assay validation was 1 microg/kg. The method had been used on a routine basis for detection and identification of zeranol in liver samples.  相似文献   

7.
A simple and rapid analytical method was developed for the determination of lincomycin and tylosin residues in honey as part of field studies examining the efficacy and target animal safety of these antibiotics to control American foulbrood disease in honey bees. Residues of the antibiotics were determined using liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). Honey samples were diluted and injected directly into the LC/MS/MS system without additional cleanup by solid-phase extraction or liquid-liquid partitioning. A six-port valve system was utilized to selectively route eluant from the LC column into the mass spectrometer only during a relatively short portion of the chromatographic run corresponding to the elution of the analytes of interest. Minimal contamination of the MS source chamber was observed despite the analysis of large numbers of samples. Using internal standard quantitation, excellent accuracy and precision were obtained with no apparent matrix-to-matrix variation. Based on the analysis of fortified replicates, the mean percent deviation from the theoretical concentration and the percent relative standard deviation were both less than 10% for tylosin over an analytical range of 10-1000 microg/kg. Slightly higher mean percent deviations and relative standard deviations were observed for the analysis of lincomycin in fortified replicate samples. The method detection limits were determined to be 5 and 2 microg/kg for lincomycin and tylosin, respectively.  相似文献   

8.
An analytical method was developed for the determination in urine of 2 metabolites of diazinon: 6-methyl-2-(1-methylethyl)-4(1H)-pyrimidinone (G-27550) and 2-(1-hydroxy-1-methylethyl)-6-methyl-4(1H)-pyrimidinone (GS-31144). Two of the urine sample preparation procedures presented rely on gas chromatography/mass selective detection (GC/MSD) in the selected ion monitoring mode for determination of G-27550. For fast sample preparation and a limit of quantitation (LOQ) of 1.0 ppb, urine samples were purified by using ENV+ solid-phase extraction (SPE) columns. For analyte confirmation at an LOQ of 0.50 ppb, classical liquid/liquid partitioning was used before further purification in a silica SPE column. An SPE sample preparation procedure and liquid chromatography/electrospray ionization/mass spectrometry/mass spectrometry (LC/ESI/MS/MS) were used for both G-27550 and GS-31144. The limit of detection was 0.01 ng for G-27550 with GC/MSD, and 0.016 ng when LC/ESI/MS/MS was used for both G-27550 and GS-31144. The LOQ was 0.50 ppb for G-27550 when GC/MSD and the partitioning/SPE sample preparation procedure were used, and 1.0 ppb for the SPE only sample preparation procedure. The LOQ was 1.0 ppb for both analytes when LC/ESI/MS/MS was used.  相似文献   

9.
A liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated to determine 90 pesticides in apple samples. MS/MS data acquisition was achieved by applying multiple-reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Matrix-matched standard calibration curves with the use of isotopically labeled standards (or a chemical analog) as internal standards were used to achieve the best accuracy for the method. Both a conventional method validation procedure and a designed experiment were applied to study the accuracy and precision of the method. A compiled computer program that provided a semiautomated procedure for handling a large number of calculations was used to calculate the overall recovery, intermediate precision, and measurement uncertainty (MU). In general, the overall recoveries from samples spiked at levels of 10, 50, and 80 microg/kg, ranged from 60.8 to 121.1%, intermediate precision was <10%, and MUs were <30%. Poor accuracy and/or repeatability was observed for pyridate and etofenprox. The method limits of detection based on a signal-to-noise ratio of >3 were usually <1 microg/kg (ppb), except those for aldicarb sulfoxide and pyridaphenthion, which were about 5 microg/kg.  相似文献   

10.
A liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the determination of bromobuterol, cimaterol, clenbuterol, clenpenterol, hydroxymethylclenbuterol, isoxsuprine, mabuterol, ractopamine, ritrodrine, salbutamol, terbutaline, and tulobuterol residues in bovine liver and retina is reported. This procedure uses enzymatic digestion, liquid-liquid extraction, and cleanup on Oasis HLB solid-phase extraction cartridges, followed by determination of the residues by LC-tandem quadrupole MS using atmospheric pressure chemical ionization in the positive ion mode. Overall average recoveries ranged from 23 to 76% for liver and 34 to 77% for retina. The mean values for samples fortified at levels between 0.5-2.0 microg/kg (liver) and 5-20 microg/kg (retina) agreed within 98-118% of the spiked levels, with coefficients of variation ranging from 6 to 20%. The decision limits, CCalpha, ranged from 0.1 to 0.3 microg/kg for liver, 1-3 microg/kg for retina, and detection capabilities, CCbeta, from 0.2-0.5 microg/kg for liver and 2-5 microg/kg for retina.  相似文献   

11.
A rapid, accurate, and selective method was developed for the forensic determination of ionophore antibiotics in animal feeds. A simple extraction procedure and liquid chromatography/tandem mass spectrometry (LC/MS/MS) in the selected reaction monitoring (SRM) mode were used for rapid identification and confirmation of monensin and lasalocid in feed samples and for quantitation of monensin. Extracts from a homogenous portion of ground feeds were prepared using liquid-solid extraction and liquid-liquid extraction techniques. Feed extracts were further purified by a simple defatting and solvent wash step and then concentrated to dryness. Feed extract residues were reconstituted in 1 mL LC mobile phase and a 2 microL aliquot injected into the SRM LC/MS system. The latter system used a C18, 100 x 2.0 mm, LC column coupled to a PE-Sciex API 2000 tandem triple quadrupole mass spectrometer equipped with a TurbolonSpray LC/MS interface. Feed samples were extracted and analyzed for the determination of monensin and lasalocid within a couple of hours. Control feed samples fortified with monensin at concentrations from 50 ppb to 5 ppm provided a linear response and calibration curve across this range with a correlation coefficient of 0.996.  相似文献   

12.
A sensitive method using liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was developed and validated to quantify and confirm 13 pesticides, including aldicarb sulfoxide, aldicarb sulfone, oxamyl, methomyl, formetanate, 3-hydroxycarbofuran, carbendazim, thiabendazole, aldicarb, propoxur, carbofuran, carbaryl, and methiocarb, in soy-based infant formula. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Different approaches to constructing calibration curves were compared and discussed to address issues of the extraction efficiency or recovery, and matrix effects. Matrix-matched standard calibration curves with the use of isoprocarb as an internal standard were finally used to achieve the best accuracy of the method. Under most circumstances, recoveries of 13 pesticides, spiked at 5.0, 25.0, and 45.0 microg/kg, were close to 100%. The method detection limits (signal-to-noise ratio > or =3:1; microg/kg) of 13 pesticides were 0.2 for thiabendazole and methiocarb, 0.6 for aldicarb, and 0.1 for the others.  相似文献   

13.
Guo M  Tan Z  Wu H  Li Z  Zhai Y 《色谱》2012,30(3):256-261
建立了同时测定贝类中大田软海绵酸(okadaic acid, OA)及其衍生物鳍藻毒素(dinophysistoxin-1, DTX-1)、蛤毒素(pectenotoxin-2, PTX-2)和虾夷扇贝毒素(yessotoxin, YTX)的液相色谱-串联质谱分析方法。样品经甲醇提取,固相萃取柱净化,C18色谱柱分离,经含甲酸和甲酸铵的乙腈-水溶液为流动相梯度洗脱,选择反应监测(SRM)模式检测,正、负离子切换扫描,基质标准校正,外标法定量。结果表明,OA、DTX-1和YTX的线性范围为2.0~200.0 μg/L,定量限(以信噪比(S/N)≥10计)为1.0 μg/kg; PTX-2的线性范围为1.0~100.0 μg/L,定量限为0.5 μg/kg;几种化合物的添加平均回收率为83.1%~105.7%,相对标准偏差(RSD)为3.16%~9.29%。成功应用本法对黄海灵山湾海域采集的贝类样品进行了分析,发现部分样品中含有大田软海绵酸、鳍藻毒素、蛤毒素和虾夷扇贝毒素。  相似文献   

14.
A method has been developed for confirmation and quantitation of ten sulfonylurea herbicides (nicosufuron, thifensulfuron-methyl, metsulfuron-methyl, sulfometuron-methyl, chlorsulfuron, ethametsulfuron-methyl, tribenuron, bensulfuron-methyl, pyrazosulfuron-ethyl and chlorimuron-ethyl) in water samples. Herbicides were extracted from water by off-line solid-phase extraction (SPE). Different types of absorbents were evaluated: silica-based ODS-C18 and two polymeric sorbents, Cleanert HXN and Oasis HLB. Analyte determination and quantitation was performed by liquid chromatography with electrospray mass spectrometry (LC-ESI-MS) instrumentation, equipped with ion trap mass filter. Confirmatory analysis was carried out by LC/MS/MS. MS data acquisition was performed by a single or two-ion extracted ion monitoring program. The ten herbicides were measured in fortified tap water. Average recoveries of the nine analytes (except for tribenuron) from water samples were in the range of 77–109%, and the RSD ranged from 0.3 to 14.5%. The limit of detections (LODs) varied from 6 to 34.8 ng/L.  相似文献   

15.
A confirmatory method based on isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the low-level determination of residues of four nitrofuran veterinary drugs in meat, e.g., furazolidone, furaltadone, nitrofurantoin, and nitrofurazone. The procedure entails an acid-catalysed release of protein-bound metabolites, followed by their in situ conversion into the 2-nitrobenzaldehyde (NBA) imine-type derivatives. Liquid-liquid extraction and clean-up on a polymeric solid phase extraction cartridge are then performed before LC-MS/MS analysis by positive electrospray ionisation (ESI) applying multiple reaction monitoring of three transition reactions for each compound. Reliable quantitation is obtained by using one deuterated analogue per analyte (d4-NBA derivative) as internal standard (IS). Validation of the method in chicken meat was conducted following the European Union (EU) criteria for the analysis of veterinary drug residues in foods. The decision limits (CCalpha) were 0.11-0.21 microg/kg, and the detection capabilities (CCbeta) 0.19-0.36 microg/kg, thus below the minimum required performance limit (MRPL) set at 1 microg/kg by the EU. The method is robust and suitable for routine quality control operations, and more than 200 sample injections were performed without excessive pollution of the mass spectrometer or loss of LC column performance.  相似文献   

16.
Xia X  Li X  Zhang S  Ding S  Jiang H  Shen J 《Analytica chimica acta》2007,586(1-2):394-398
A sensitive and reliable multiresidue method is described for analysis of ronidazole, metronidazole, dimetridazole and the common metabolite of ronidazole and dimetridazole, 2-hydroxymethyl-1-methyl-5-nitroimidazole in swine liver. The sample preparation procedure was based on liquid-liquid extraction and mixed mode cation exchange/reverse phase solid-phase extraction. The compounds of interest were determined by reverse phase gradient liquid chromatography separation and tandem mass spectrometry (MS/MS) in the multiple reaction monitoring (MRM) mode. The limits of confirmation were 0.1-0.5 microg kg(-1) for the analytes.  相似文献   

17.
A comparison of two methods for the identification and determination of peanut allergens based on europium (Eu)-tagged inductively coupled plasma mass spectrometry (ICP-MS) immunoassay and on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with a triple quadrupole mass analyzer was carried out on a complex food matrix like a chocolate rice crispy-based snack. The LC/MS/MS method was based on the determination of four different peptide biomarkers selective for the Ara h2 and Ara h3/4 peanut proteins. The performance of this method was compared with that of a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) method with ICP-MS detection of the metal used to tag the antibody for the quantitative peanut protein analysis in food. The limit of detection (LOD) and quantitation of the ICP-MS immunoassay were 2.2 and 5 microg peanuts g(-1) matrix, respectively, the recovery ranged from 86 +/- 18% to 110 +/- 4% and linearity was proved in the 5-50 microg g(-1) range. The LC/MS/MS method allowed us to obtain LODs of 1 and 5 microg protein g(-1) matrix for Ara h3/4 and Ara h2, respectively, thus obtaining significantly higher values with respect to the ELISA ICP-MS method, taking into account the different expression for concentrations. Linearity was established in the 10-200 microg g(-1) range of peanut proteins in the food matrix investigated and good precision (RSD <10%) was demonstrated. Both the two approaches, used for screening or confirmative purposes, showed the power of mass spectrometry when used as a very selective detector in difficult matrices even if some limitations still exist, i.e. matrix suppression in the LC/ESI-MS/MS procedure and the change of the Ag/Ab binding with matrix in the ICP-MS method.  相似文献   

18.
Zhang J  Yang L  Lin L  Chen L  Zhou Y  Xu D 《色谱》2011,29(7):637-642
建立了食品中多杀菌素(spinosyn) A和D残留的液相色谱-串联质谱(HPLC-MS/MS)检测方法。甘蓝等食品样品经乙腈-水(50:50, v/v)提取、HLB固相萃取柱净化后,采用HPLC-MS/MS进行检测分析,利用外标法定量。质谱分析采用电喷雾电离,正离子扫描,多反应监测模式。结果表明,柱净化后无明显的基质效应,多杀菌素在1~20 μg/L内具有较好的线性关系,其相关系数可达0.9999;样品中添加1~10 μg/kg的多杀菌素,其回收率为76.2%~114.0%,相对标准偏差(n=10)小于10%;检出限(信噪比(S/N)=3): 多杀菌素A为0.2 μg/kg,多杀菌素D为0.5 μg/kg;定量限(S/N=10): 多杀菌素A为0.5 μg/kg,多杀菌素D为1.0 μg/kg。在最佳实验条件下,对来自福建厦门的969份食品样品进行了检测,其中15份样品检测结果呈阳性。实验结果表明,该方法提取效果好,具有良好的灵敏度、回收率和重复性。  相似文献   

19.
A gas chromatography/mass spectrometry (GC/MS) method was developed for the quantitative determination and confirmation of patulin extracted from apple juice. Juice is alkalized and extracted with ethyl acetate-hexane, a portion concentrated under N2, then resolubilized in acetonitrile for simple derivatization with bis(trimethylsilyl)trifluoracetamide. Patulin was determined by GC/MS using an electron-impact source and selected ion monitoring of characteristic ions. Spike levels of 20-100 microg/L gave an average recovery of 86%, and 6 ions of sample and standard spectra matched within 10% absolute for confirmation. The limits of quantitation and detection were 10 and 3 microg/L, respectively.  相似文献   

20.
A liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOFMS) method has been developed for the determination of 12 pesticides (namely, carbendazim, thiabendazole, imazalil, tridemorph, triadimefon, bitertanol, prochloraz, flutriafol, myclobutanil, iprodione, diphenylamine and procymidone) in fruit-based baby food (multi-fruit jars and juices intended for infant consumption). The developed method consists of a sample treatment step based on liquid-liquid extraction using acetonitrile, followed by a clean-up step based on dispersive solid-phase extraction (SPE) with a primary-secondary amine (PSA). Multi-fruit and apple juices were processed by a SPE procedure using Oasis HLB cartridges. Subsequent identification and quantitation was accomplished by LC/ESI-TOFMS analysis: the confirmation of the target pesticides was based on accurate mass measurements of selected ions (protonated molecules ([M+H]+) and fragment ions). Confirmation studies were accomplished at low concentration levels (10 microg kg-1) and accuracy errors lower than 2 ppm were obtained in most cases. Baby food extracts spiked at 10 microg kg-1 fortification level yielded average recoveries in the range 78-105% with relative standard deviations less than 10% for most of the analytes. Limits of detection (LODs) were between 0.1 and 4 microg kg-1 depending on the pesticide studied. Finally, the proposed method was applied to a total of 33 baby food samples from Spain and the United Kingdom. Although imazalil, thiabendazole and carbendazim were detected in a high number--over 60%- of baby food samples, none of the samples tested were found to be above the 0.01 mg kg-1 EU standard.  相似文献   