首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report a cyclic sample pooling technique devised in two‐dimensional liquid chromatography–electrospray ionization mass spectrometry (LC‐ESI‐MS) shotgun proteomics that renders deeper proteome coverage; we combined low pH reversed‐phase (RP) LC in trifluoroacetic acid in the first dimension, followed by cyclic sample pooling of the eluate and low‐pH RP‐LC in formic acid in the second dimension. The new protocol has a significantly higher resolving power suitable for LC‐ESI‐MS/MS shotgun proteomics. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Peptide acetylation and dimethylation have been widely used to derivatize primary amino groups (peptide N‐termini and the ε‐amino group of lysines) for chemical isotope labeling of quantitative proteomics or for affinity tag labeling for selection and enrichment of labeled peptides. However, peptide acetylation results in signal suppression during electrospray ionization (ESI) due to charge neutralization. In contrast, dimethylated peptides show increased ionization efficiency after derivatization, since dimethylation increases hydrophobicity and maintains a positive charge on the peptide under common LC conditions. In this study, we quantitatively compared the ESI efficiencies of acetylated and dimethylated model peptides and tryptic peptides of BSA. Dimethylated peptides showed higher ionization efficiency than acetylated peptides for both model peptides and tryptic BSA peptides. At the proteome level, peptide dimethylation led to better protein identification than peptide acetylation when tryptic peptides of mouse brain lysate were analyzed with LC‐ESI‐MS/MS. These results demonstrate that dimethylation of tryptic peptides enhanced ESI efficiency and provided up to two‐fold improved protein identification sensitivity in comparison with acetylation. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
Dimedone is the most widely used chemical probe for detection of cysteine sulfenic acid in peptides and proteins. The reaction of dimedone with cysteine sulfenic acid results in the formation of unique cysteine dimedone motif containing thioether bridge. Based on the structure of cysteine dimedone residue in polypeptide, a new building block of Fmoc-Cys(Dmd)-OH was developed for solid phase synthesis of peptide cysteine dimedone. Mass spectrometric sequencing of synthetic peptides have confirmed successful incorporation of cysteine dimedone in peptide chain using HBTU/HOBt as a coupling agent. The new method permits synthesis of peptides containing both cysteine thiol and cysteine dimedone in the same sequence which was difficult to achieve by conventional methods. The synthetic peptide of glutathione cysteine dimedone was used as a standard in probing the air-mediated oxidation of thiol to disulfide form of glutathione. The co-elution of standard peptide and reaction mixture of oxidation of glutathione in presence of dimedone using RP-HPLC have confirmed the formation of glutathione cysteine sulfenic as an intermediate in the air-mediated oxidation of glutathione. The synthetic peptides of cysteine dimedone may find application in the field of redox proteomics and generation of antibodies against modified cysteine residue.  相似文献   

4.
Capillary zone electrophoresis (CZE)–tandem mass spectrometry (MS/MS) has recently attracted attention as a tool for shotgun proteomics. However, its performance for this analysis has so far fallen far below that of reversed‐phase liquid chromatography (RPLC)–MS/MS. The use of a CZE method with a wide separation window (up to 90 min) and high peak capacity (ca. 300) is reported. This method was coupled to an Orbitrap Fusion mass spectrometer through an electrokinetically pumped sheath‐flow interface for the analysis of complex proteome digests. Single‐shot CZE–MS/MS lead to the identification of over 10 000 peptides and 2100 proteins from a HeLa cell proteome digest in approximately 100 min. This performance is nearly an order of magnitude better than earlier CZE studies and is within a factor of two to four of the state‐of‐the‐art nano ultrahigh‐pressure LC system.  相似文献   

5.
Protein identification is routinely accomplished by peptide sequencing using mass spectrometry (MS) after enzymatic digestion. Site-specific chemical modification may improve peptide ionization efficiency or sequence coverage in mass spectrometry. We report herein that amino group of lysine residue in peptides can be selectively modified by reaction with a peroxycarbonate and the resulting lysine peroxycarbamates undergo homolytic fragmentation under conditions of low-energy collision-induced dissociation (CID) in electrospray ionization (ESI) and matrix-assisted laser desorption and ionization (MALDI) MS. Selective modification of lysine residue in peptides by our strategy can induce specific peptide cleavage at or near the lysine site. Studies using deuterated analogues of modified lysine indicate that fragmentation of the modified peptides involves apparent free-radical processes that lead to peptide chain fragmentation and side-chain loss. The formation of a-, c-, or z-types of ions in MS is reminiscent of the proposed free-radical mechanisms in low-energy electron capture dissociation (ECD) processes that may have better sequence coverage than that of the conventional CID method. This site-specific cleavage of peptides by free radical- promoted processes is feasible and such strategies may aid the protein sequencing analysis and have potential applications in top-down proteomics.  相似文献   

6.
7.
Many protein extraction methods have been developed for plant proteome analysis but information is limited on the optimal protein extraction method from algae species. This study evaluated four protein extraction methods, i.e. direct lysis buffer method, TCA‐acetone method, phenol method, and phenol/TCA‐acetone method, using green algae Chlorella vulgaris for proteome analysis. The data presented showed that phenol/TCA‐acetone method was superior to the other three tested methods with regards to shotgun proteomics. Proteins identified using shotgun proteomics were validated using sequential window acquisition of all theoretical fragment‐ion spectra (SWATH) technique. Additionally, SWATH provides protein quantitation information from different methods and protein abundance using different protein extraction methods was evaluated. These results highlight the importance of green algae protein extraction method for subsequent MS analysis and identification.  相似文献   

8.
We report a premier side-by-side comparison of two leading types of monolithic nano-LC column (silica-C(18), polystyrene) in shotgun proteomics experiments. Besides comparing the columns in terms of the number of peptides from a real-life sample (Arabidopsis thaliana chloroplast) that they identified, we compared the monoliths in terms of peak capacity and retention behavior for standard peptides. For proteomics applications where the mobile phase composition is constrained by electrospray ionization considerations (i.e., there is a restricted choice of ion-pairing modifiers), the polystyrene nano-LC column exhibited reduced identification power. The silica monolith column was superior in all measured values and compared very favorably with traditional packed columns. Finally, we investigated the performances of the monoliths at high flow rates in an attempt to demonstrate their advantages for high-throughput identification.  相似文献   

9.
Mass spectrometry (MS)‐based quantitative proteomics has become a critical component of biological and clinical research for identification of biomarkers that can be used for early detection of diseases. In particular, MS‐based targeted quantitative proteomics has been recently developed for the detection and validation of biomarker candidates in complex biological samples. In such approaches, synthetic reference peptides that are the stable isotope labeled version of proteotypic peptides of proteins to be quantitated are used as internal standards enabling specific identification and absolute quantification of targeted peptides. The quantification of targeted peptides is achieved using the intensity ratio of a native peptide to the corresponding reference peptide whose spike‐in amount is known. However, a manual calculation of the ratios can be time‐consuming and labor‐intensive, especially when the number of peptides to be tested is large. To establish a liquid chromatography/matrix‐assisted laser desorption/ionization time‐of‐flight tandem mass spectrometry (LC/MALDI TOF/TOF)‐based targeted quantitative proteomics pipeline, we have developed a software named Mass Spectrometry based Quantification (MSQ). This software can be used to automate the quantification and identification of targeted peptides/proteins by the MALDI TOF/TOF platform. MSQ was applied to the detection of a selected group of targeted peptides in pooled human cerebrospinal spinal fluid (CSF) from patients with Alzheimer's disease (AD) in comparison with age‐matched control (OC). The results for the automated quantification and identification of targeted peptides/proteins in CSF were in good agreement with results calculated manually. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
Balgley BM  Wang W  Song T  Fang X  Yang L  Lee CS 《Electrophoresis》2008,29(14):3047-3054
Multidimensional separations of the peptides resulting from enzymatic digestions of complex protein mixtures prior to MS/MS, namely shotgun proteomics, is increasingly utilized for large-scale identification and quantitation of proteins. Inherent to the performance of proteomic measurements is the resolving power of each of the separations both separately and in combination. By simply raising the number of CIEF fractions, the resulting enhancement in the overall peak capacity of combined CIEF/nano-RPLC separations greatly reduces the complexity of eluted peptides prior to MS detection and sequencing and increases the proteome coverage. The capabilities of the CIEF-based proteome platform coupled with the spectral counting approach to confidently and reproducibly quantify proteins and changes in protein expression levels among samples are evaluated. Analytical reproducibility of relative protein abundance is determined to exhibit a Pearson R(2) value greater than 0.99 and a CV of 14.1%. The platform is demonstrated to be capable of measuring changes in protein expression as low as 1.5-fold, with confidence following multiple testing adjustment.  相似文献   

11.
The conventional protocol for protein identification by electrospray ionization mass spectrometry (MS) is based on enzymatic digestion which renders peptides to be analyzed by liquid chromatography-MS and collision-induced dissociation (CID) multistage MS, in the so-called bottom-up approach. Though this method has brought a significant progress to the field, many limitations, among which, the low throughput and impossibility to characterize in detail posttranslational modifications in terms of site(s) and structure, were reported. Therefore, the research is presently focused on the development of procedures for efficient top-down fragmentation of intact protein ions. In this context, we developed here an approach combining fully automated chip-based-nanoelectrospray ionisation (nanoESI), performed on a NanoMate robot, with electron transfer dissociation (ETD) for peptide and top-down protein sequencing and identification. This advanced analytical platform, integrating robotics, microfluidics technology, ETD and alternate ETD/CID, was tested and found ideally suitable for structural investigation of peptides and modified/functionalized peptides as well as for top-down analysis of medium size proteins by tandem MS experiments of significantly increased throughput and sensitivity. The obtained results indicate that NanoMate-ETD and ETD/CID may represent a viable alternative to the current MS strategies, with potential to develop into a method of routine use for high throughput top-down proteomics.  相似文献   

12.
Off‐gel? IEF has become a popular tool in proteomics research to fractionate peptides or proteins. We conducted a detailed investigation on the fruit proteomics of apple, banana, and strawberry fruit employing Off‐gel? electrophoresis (OGE) as a crucial step to improve the proteome coverage and quantitative proteomic workflows including multiple‐reaction monitoring (MRM). We provide technical details concerning the application of Off‐gel?IEF, nano‐LC–MS detection, and MRM optimization and analysis. Our results demonstrated that the application of OGE is an effective method for peptide fractionation and increased significantly the number of proteins identified by at least ten times, with more total peptides detected and collected. Furthermore, we developed a protocol combining OGE and MRM studies to identify and quantitatively investigate monodehydroascorbate reductase, a key enzyme in the redox and antioxidant system of apple fruit during fruit ripening. Using this method, the quantitative changes in this protein during ripening and in response to ethylene treatment was investigated. Our results provide direct and comprehensive evidence demonstrating the benefits of OGE and its application for both shotgun and quantitative proteomics research.  相似文献   

13.
Electrospray ionization ion trap mass spectrometry (ESI-ITMS) coupled to a two-dimensional liquid chromatographic separation was applied to the identification of peptides in antimicrobial fractions of the aqueous extracts of nine Italian cheese varieties. In particular, the chromatographic fractions collected during a preliminary fast protein liquid chromatography (FPLC) separation on the cheese extracts were assayed for antimicrobial activity towards Lactobacillus sakei A15. Active fractions were subsequently analyzed by reversed-phase high-performance liquid chromatography electrospray ionization sequential mass spectrometry (HPLC/ESI)-ITMSn, with n up to 3. Peptide identification was then performed starting from a conventional proteomics approach based on tandem mass spectrometric (MS/MS) analysis followed by database searching. In many cases this strategy had to be integrated by a careful correlation between spectral information and predicted peptide fragmentation, in order to reach unambiguous identifications. When even this integrated approach failed, MS3 measurements provided decisive information on the amino acid sequence of some peptides, through fragmentation of pendant groups along the peptide chain. As a result, 45 peptides, all arising from hydrolysis of milk caseins, were identified in nine antimicrobial FPLC fractions of aqueous extracts obtained from five of the nine cheese varieties considered. Many of them corresponded to peptides already known to exhibit biological activity.  相似文献   

14.
Mono‐ and poly‐adenosine diphosphate (ADP)‐ribosylation are common post‐translational modifications incorporated by sequence‐specific enzymes at, predominantly, arginine, asparagine, glutamic acid or aspartic acid residues, whereas non‐enzymatic ADP‐ribosylation (glycation) modifies lysine and cysteine residues. These glycated proteins and peptides (Amadori‐compounds) are commonly found in organisms, but have so far not been investigated to any great degree. In this study, we have analyzed their fragmentation characteristics using different mass spectrometry (MS) techniques. In matrix‐assisted laser desorption/ionization (MALDI)‐MS, the ADP‐ribosyl group was cleaved, almost completely, at the pyrophosphate bond by in‐source decay. In contrast, this cleavage was very weak in electrospray ionization (ESI)‐MS. The same fragmentation site also dominated the MALDI‐PSD (post‐source decay) and ESI‐CID (collision‐induced dissociation) mass spectra. The remaining phospho‐ribosyl group (formed by the loss of adenosine monophosphate) was stable, providing a direct and reliable identification of the modification site via the b‐ and y‐ion series. Cleavage of the ADP‐ribose pyrophosphate bond under CID conditions gives access to both neutral loss (347.10 u) and precursor‐ion scans (m/z 348.08), and thereby permits the identification of ADP‐ribosylated peptides in complex mixtures with high sensitivity and specificity. With electron transfer dissociation (ETD), the ADP‐ribosyl group was stable, providing ADP‐ribosylated c‐ and z‐ions, and thus allowing reliable sequence analyses. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Amino acids residues are commonly submitted to various physicochemical modifications occurring at physiological pH and temperature. Post‐translational modifications (PTMs) require comprehensive characterization because of their major influence on protein structure and involvement in numerous in vivo process or signaling. Mass spectrometry (MS) has gradually become an analytical tool of choice to characterize PTMs; however, some modifications are still challenging because of sample faint modification levels or difficulty to separate an intact peptide from modified counterparts before their transfer to the ionization source. Here, we report the implementation of capillary zone electrophoresis coupled to electrospray ionization tandem mass spectrometry (CZE‐ESI‐MS/MS) by the intermediate of a sheathless interfacing for independent and highly sensitive characterization of asparagine deamidation (deaN) and aspartic acid isomerization (isoD). CZE selectivity regarding deaN and isoD was studied extensively using different sets of synthetic peptides based on actual tryptic peptides. Results demonstrated CZE ability to separate the unmodified peptide from modified homologous exhibiting deaN, isoD or both independently with a resolution systematically superior to 1.29. Developed CZE‐ESI‐MS/MS method was applied for the characterization of monoclonal antibodies and complex protein mixture. Conserved CZE selectivity could be demonstrated even for complex samples, and foremost results obtained showed that CZE selectivity is similar regardless of the composition of the peptide. Separation of modified peptides prior to the MS analysis allowed to characterize and estimate modification levels of the sample independently for deaN and isoD even for peptides affected by both modifications and, as a consequence, enables to distinguish the formation of l ‐aspartic acid or d ‐aspartic acid generated from deaN. Separation based on peptide modification allowed, as supported by the ESI efficiency provided by CZE‐ESI‐MS/MS properties, and enabled to characterize and estimate studied PTMs with an unprecedented sensitivity and proved the relevance of implementing an electrophoretic driven separation for MS‐based peptide analysis. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
The separation of complex peptide mixtures in shotgun proteome analysis using a 2D separation scheme encompassing reversed-phase × ion-pair reversed-phase (IP-RP) liquid chromatography coupled online to electrospray ion trap mass spectrometry (MS) has been shown earlier to be superior in terms of separation efficiency and technical robustness compared to the classically used separation scheme encompassing strong cation exchange × IP-RP-chromatography in shotgun proteome analysis. In the present study, this novel separation scheme was coupled offline to matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF)/TOF-MS for the analysis of the same sample, a tryptic digest of the cytosolic proteome of the bacterium Corynebacterium glutamicum. Compared to the earlier study, the MALDI-based platform led to a significantly increased number of peptides (7,416 vs. 2,709) and proteins (1,208 vs. 468, without single peptide-based identifications), respectively. This represents the majority of all predicted cytosolic proteins in C. glutamicum. The high proteome coverage, as well as the large number of low-abundant proteins identified with this improved analytical platform, pave the way for new biological studies. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

17.
Oxidation of a protein cysteine thiol to sulfenic acid, termed S-sulfenylation, is a reversible post-translational modification that plays a crucial role in regulating protein function and is correlated with disease states. The majority of reaction-based small molecule and immunochemical probes used for detecting sulfenic acids are based on the 5,5-dimethyl-1,3-cyclohexanedione (dimedone) scaffold, which is selective, but suffers from low reactivity. In addition, mechanistic details and features that diminish or enhance nucleophile reactivity remain largely unknown. A significant hurdle to resolving the aforementioned issues has been the chemically unstable nature of small-molecule sulfenic acid models. Herein, we report a facile mass spectrometry-based assay and repurposed dipeptide-based model to screen a library of cyclic C-nucleophiles for reactivity with sulfenic acid under aqueous conditions. Observed rate constants for ∼100 cyclic C-nucleophiles were obtained and, from this collection, we have identified novel compounds with more than 200-fold enhanced reactivity, as compared to dimedone. The increase in reactivity and retention of selectivity of these C-nucleophiles were validated in secondary assays, including a protein model for sulfenic acid. Together, this work represents a significant step toward developing new chemical reporters for detecting protein S-sulfenylation with superior kinetic resolution. The enhanced rates and varied composition of the C-nucleophiles should enable more comprehensive analyses of the sulfenome and serve as the foundation for reversible or irreversible nucleophilic covalent inhibitors that target oxidized cysteine residues in therapeutically important proteins.  相似文献   

18.
β-ketoesters are robust probes for labeling sulfenic acid (-SOH) proteins allowing quantitative cleavage of the tag for improved analysis of the labeled peptides by MS.  相似文献   

19.
Microfluidic devices coupled to mass spectrometers have emerged as excellent tools for solving the complex analytical challenges associated with the field of proteomics. Current proteome identification procedures are accomplished through a series of steps that require many hours of labor‐intensive work. Microfluidics can play an important role in proteomic sample preparation steps prior to mass spectral identification such as sample cleanup, digestion, and separations due to its ability to handle small sample quantities with the potential for high‐throughput parallel analysis. To utilize microfluidic devices for proteomic analysis, an efficient interface between the microchip and the mass spectrometer is required. This tutorial provides an overview of the technologies and applications of microfluidic chips coupled to mass spectrometry for proteome analysis. Various approaches for combining microfluidic devices with electrospray ionization (ESI) and matrix‐assisted laser desorption/ionization (MALDI) are summarized and applications of chip‐based separations and digestion technologies to proteomic analysis are presented. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Improving the sensitivity of detection and fragmentation of peptides to provide reliable sequencing of peptides is an important goal of mass spectrometric analysis. Peptides derivatized by bicyclic quaternary ammonium ionization tags: 1‐azabicyclo[2.2.2]octane (ABCO) or 1,4‐diazabicyclo[2.2.2]octane (DABCO), are characterized by an increased detection sensitivity in electrospray ionization mass spectrometry (ESI‐MS) and longer retention times on the reverse‐phase (RP) chromatography columns. The improvement of the detection limit was observed even for peptides dissolved in 10 mM NaCl. Collision‐induced dissociation tandem mass spectrometry of quaternary ammonium salts derivatives of peptides showed dominant a‐ and b‐type ions, allowing facile sequencing of peptides. The bicyclic ionization tags are stable in collision‐induced dissociation experiments, and the resulted fragmentation pattern is not significantly influenced by either acidic or basic amino acid residues in the peptide sequence. Obtained results indicate the general usefulness of the bicyclic quaternary ammonium ionization tags for ESI‐MS/MS sequencing of peptides. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号