首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Methods for determining concentrations of a new morpholino anthracycline MX2.HCl and its metabolites in biological samples using reversed-phase high-performance liquid chromatography and fluorescence detection are described. The limits of detection were less than 1 ng/ml for all compounds after extraction from 0.5 ml of plasma using C18 Sep-Pak cartridges and consecutive solvent extraction. The recoveries from rat plasma ranged from 72.0 to 89.3%. The peak-height ratio of the fluorescence intensities of these compounds versus internal standard showed a linear correlation for concentrations up to at least 500 ng/ml in the plasma (correlation coefficient r greater than 0.999). The within-day and between-day precisions of this assay were in the range 0.8-8.7% (n = 5) and 2.0-3.5% (n = 5), respectively. The concentrations of these compounds in the blood and urine can be also determined by a slight modification of the extraction procedure.  相似文献   

2.
An accurate and sensitive high-performance liquid chromatographic method with UV detection was developed for the simultaneous measurement of monoethylglycinexylidide (MEGX) and lignocaine in human plasma and serum, using organic solvent extraction and trimethoprim (TMP) as an internal standard. The mean recoveries for MEGX, TMP and lignocaine were 86.1 +/- 3.7, 98.3 +/- 1.8 and 77.0 +/- 4.7%, respectively (n = 6). The relative standard deviations for MEGX concentrations of 10 and 200 ng/ml were less than 4% and for lignocaine concentrations of 200 and 1200 ng/ml they were less than 8%.  相似文献   

3.
A sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the quantitation of mitoxantrone in plasma using electrochemical detection. Bisantrene was chosen as the internal standard. A reversed-phase, 10-microns muBondapak C18 analytical column (30 cm X 3.9 mm) with an isocratic mobile phase of 28% acetonitrile in 80 mM sodium formate buffer (pH 3.0) was used. The eluent was monitored by both electrochemical detection at an applied potential of +0.75 V vs. Ag/AgCl and visible absorbance at 660 nm. Only electrochemical detection was able to quantitate the internal standard and provided ten times higher sensitivity than visible absorbance for mitoxantrone with a detection limit as low as 0.1 ng/ml. Calibration curves in the range 0.1-1000 ng/ml showed good linearity (r = 0.998) and precision (coefficient of variation less than 10%). This HPLC method utilized a reproducible and inexpensive liquid-liquid extraction procedure. Using methylene chloride, the extraction efficacy of mitoxantrone from plasma was 85.3% with a coefficient of variation less than 2.1%. This new assay was then applied to measure mitoxantrone concentrations in plasma obtained from two leukemic patients receiving 12 mg/m2 mitoxantrone as a 1-h infusion.  相似文献   

4.
A high-performance liquid chromatographic procedure requiring neither derivatization nor complex sample work-up is reported for reproducibly and sensitively determining pilocarpine in plasma. Following stabilization of pilocarpine against in vitro hydrolysis using sodium fluoride, plasma samples were extracted and the extracts chromatographed on a 5-microns, low-carbon-load (6%) C18 reversed-phase column. The assay was linear between 10 and 300 ng/ml (r = 0.998). It had sufficient sensitivity to quantitate pilocarpine at concentrations as low as 10 ng/ml (signal-to-noise ratio > or = 4) using a 500-microliters sample. The assay appears to be the first published specifically for plasma determinations and has proven capable of supporting pharmacokinetics studies of pilocarpine disposition in the anesthetized dog.  相似文献   

5.
p-Methylthiobenzamide (PMTB) is a thiocarbonyl compound exhibiting marked hepatotoxicity and nephrotoxicity. We describe a high-performance liquid chromatographic method for analyzing PMTB and a metabolite, p-methylthiobenzamide-S-oxide (PMTBSO), from rat plasma using a solid-phase extraction technique. In this way, PMTB and PMTBSO can be extracted from 0.5 ml of plasma and separation achieved by an ODS analytical column in as little as 9 min. The mobile phase used was methanol-water (55:45, v/v) and the wavelength for detection was 290 nm. The limits of detection in plasma were 15 ng/ml for PMTB and 33 ng/ml for PMTBSO; the absolute recovery from spiked plasma samples was greater than 84.4% for both compounds and the internal standard. The method was linear throughout the range used with correlation coefficients greater than 0.969. The intra-day accuracy ranged from 1.52 to 15.23% relative error for the PMTB concentration range 151-3025 ng/ml; accuracy of 4.97% or less was obtained for PMTBSO concentrations of 1672-20,068 ng/ml. The intra-day precision (coefficient of variation) of the procedure was found to be no greater than 5.28% for PMTB and 7.9% for PMTBSO. Inter-day accuracy and precision measurements were similar.  相似文献   

6.
The determination of citalopram, amitriptyline, clomipramine and their desmethyl metabolites after alkaline diethyl either extraction from plasma is achieved by high-performance liquid chromatography using two internal standards and mu Bondapak C18 as stationary phase. Elution is carried out isocratically at 0.5 or 1 ml/min with a mixture of acetonitrile-potassium dihydrogen phosphate-distilled water (45:50:5). Detection is monitored by absorption at 254 nm. The detection limit is less than 5 ng/ml for each compound. The coefficients of variation are between 1.3% and 9.4% for 8-360 ng/ml. Interference from 22 possible co-medications is discussed. The technique can be used for therapeutic monitoring of these antidepressants as well as in analytical toxicology.  相似文献   

7.
A sensitive high-performance liquid chromatographic technique is described for the separation of R- and S-acebutolol in human plasma and urine. The procedure involves derivatization with the chiral reagent S-(+)-1-(1-naphthyl)ethyl isocyanate. The resulting diastereoisomers are quantified using normal-phase high-performance liquid chromatography with fluorescence detection (220/389 nm). Virtual baseline separation, free from interference, with achieved (resolution factor = 1.45). Excellent linearity (r greater than 0.998) was observed throughout the range 10-500 ng/l and 2-100 mg/l in plasma and urine, respectively. Inter-assay variability was less than 5% for each enantiomer at concentrations of 10 ng/ml. This method is applicable for the determination of the pharmacokinetics, in man, of acebutolol enantiomers in plasma and urine.  相似文献   

8.
A gas chromatographic-mass spectrometric method was developed to determine eperisone hydrochloride, 4'-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2-40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml, the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.  相似文献   

9.
A rapid and sensitive method for extracting temazepam from human serum and urine is presented. Free temazepam is extracted from plasma and urine samples using n-butyl chloride with nitrazepam as the internal standard. Temazepam glucuronide is analyzed as free temazepam after incubating extracts with beta-glucuronidase. Separation is achieved using a C8 reversed-phase column with a methanol-water-phosphate buffer mobile phase. An ultraviolet detector operated at 230 nm is used and a linear response is observed from 20 ng/ml to 10 micrograms/ml. The limit of detection is 15.5 ng/ml and the limit of quantitation is 46.5 ng/ml. Coefficients of variation are less than 10% for concentrations greater than 50 ng/ml. Application of the methodology is demonstrated in a pharmacokinetic study using eight healthy male subjects.  相似文献   

10.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

11.
The assay procedure of underivatized, intact nitrazepam and clonazepam in human plasma is described, using gas chromatography with a support-coated open tubular column (OV-17), a solid injection system and electron-capture detection. Clonazepam is used as a internal standard in the assay of nitrazepam and vice versa. Linear calibration curves after a single extraction step were obtained in the concentration range 10--100 ng/ml plasma, with standard deviations less than 4.9%. The sensitivity limit of the method is about 1 ng/ml plasma for both drugs. The method was applied to pharmacokinetic and bioavailability studies of nitrazepam in humans. Seven healthy volunteers received two nitrazepam-containing tablet preparations (5 mg) and plasma concentrations were determined regularly from 15 min to 80 h following drug administration. The mean elimination half-life of nitrazepam was 27 h (range 13-34 h). Considerable intra-individual differences in peak level times between the two preparations were observed, whereas the extent of bioavailability was rather similar.  相似文献   

12.
A procedure for the determination of dialkyphosphorus metabolites of organophosphorus pesticides in human blood has been worked out. Dimethyl and diethyl phosphates, phosphorothioates and phosphorodithioates, extracted with diethyl ether from plasma acidified with hydrochloric acid, were methylated with diazomethane and analysed by capillary gas chromatography with an alkali flame ionization detector and an ion trap detector. The extraction of metabolites was preceded by n-hexane extraction of parent organophosphorus pesticides without a negative effect on the efficiency of metabolite extraction. If plasma samples, containing 2 μ/ml of each metabolite, were not saturated with sodium chloride before extraction, only dialkyl phosphorothioates were recovered by more than 80%. The recoveries of other metabolites were less than 25%. The extraction of plasma samples saturated with sodium chloride resulted in higher recoveries of all metabolites. At concentrations ranging from 0.2 to 2.8 μg/ml the accumulation effeciencies (%±S.D.) of dimethyl and diethyl phosphorothioates were 92±20 and 97±11, and those of corresponding phosphorodithiotes 79±7 and 71±4. A significantly lower recovery (36±12%) was determined for dimethyl phosphate at concentrations in plasma below 2 μg/ml. The recovery of diethyl phosphate was dependent on the initial metabolite concentration in plasma being 31±5% at concentrations lower than 0.5 μg/ml, 51±12% at concentrations ranging from 0.7 to 1.7 μg/ml and 97±3% at concentrations at or above 2 μg/ml. Detection limits of metabolites in plasma using the phosphorus selective detector were 150 ng/ml for dimethyl phosphate and 50 ng/ml for other metabolites. Those values were for dialkyl phosphates and phophorothioates three to five times lower and for diakyl phosphorodithiotes even 30 times lower than detection limits achieved by the use of ion trap detector. The procedure was applied for the evidence and confirmation of human poisoning with organophosphorus pesticides.  相似文献   

13.
A method is described for determination of minoxidil in human plasma using high-performance liquid chromatography with electrochemical detection. The method is specific and sensitive (500 pg/ml), however, minoxidil and minoxidil sulfate cannot be differentiated due to rapid autohydrolysis of minoxidil sulfate to minoxidil. The extraction procedure employs a C18 preparatory column to remove endogenous plasma constituents which would interfere with the assays. The calibration curves are linear for concentrations from 500 pg to 10 ng/ml. Within-day and between-day reproducibility are satisfactory with coefficient of variation less than 5.7% for all concentrations. Sample recovery from extraction is consistent at 45 to 55% at low and high concentrations, respectively. A pharmacokinetic study in a hypertensive volunteer receiving two different oral doses of minoxidil (1.25 and 2.5 mg) on different occasions demonstrates the utility of the method.  相似文献   

14.
A column-switching system for the direct injection of plasma or serum samples, followed by isocratic high-performance liquid chromatography and ultraviolet detection, is described for the simultaneous quantitation of the tricyclic antidepressant amitriptyline, its demethylated metabolite nortriptyline and the E- and Z-isomers of 10-hydroxyamitriptyline and 10-hydroxynortriptyline. The method included adsorption of amitriptyline and metabolites on a reversed-phase C8 clean-up column (10 microns; 20 mm x 4.6 mm I.D.), washing of unwanted material to waste and, after on-line column-switching, separation on a cyanopropyl analytical column (5 microns; 250 mm x 4.6 mm I.D.). The compounds of interest were separated and eluted using acetonitrile-methanol-0.01 M phosphate buffer (pH 6.8) (578:188:235, v/v) within less than 20 min. Various drugs frequently co-administered with amitriptyline or other antidepressants did not interfere with the determinations. In plasma samples spiked with 25-300 ng/ml, the recoveries were between 84 and 112% and the inter-assay coefficients of variation were 3-11%. After a minor modification, as little as 5 ng/ml could be quantitated. There were linear correlations (r greater than 0.99) between drug concentrations of 5-500 ng/ml and the detector signal. The method allows routine measurements of amitriptyline, nortriptyline and hydroxylated metabolites in blood plasma or serum of patients treated with amitriptyline or nortriptyline, and enables the results to be reported within 1 h.  相似文献   

15.
A sensitive and selective high-performance capillary electrophoresis procedure was developed for the determination of S(+) and R(-) enantiomers of cicletanine in human plasma. The procedure consisted in extraction of the drug with diethyl ether and analysis by micellar electrokinetic capillary chromatography in a fused-silica capillary using gamma-cyclodextrins in the run buffers and ultraviolet detection. The method was linear from 10 to 500 ng/ml and the limit of detection was 10 ng/ml for each enantiomer in plasma samples. The within-run precision of the method, expressed as relative standard deviation, was 10.4 and 9.6% at 25 ng/ml for S(+) and R(-) cicletanine, and 4.2 and 4.6% at 500 ng/ml, respectively. This method has been used to follow the time course of the concentrations of the cicletanine enantiomers in human plasma after a single therapeutic dose of cicletanine given by mouth.  相似文献   

16.
The dopamine receptor agonist R(-)N-n-propylnorapomorphine (NPA) and its proposed pro-drug R(-)10,11-methylenedioxy-N-n-propylnoraporphine (MDO-NPA) were isolated simultaneously from monkey plasma using a solid-phase extraction procedure. R(-)Apomorphine (APO) and R(-)10,11-methylenedioxyaporphine (MDO-APO) were added as internal standards, and separation and quantification were by high-performance liquid chromatography with electrochemical or ultraviolet detection of the free catechol and MDO compounds, respectively. The detection limits for NPA and MDO-NPA in plasma were 0.5 and 10 ng/ml and the coefficient of variation (S.D./mean) within assays and between days of assays for both drugs was 5.6% or less. Quantification of plasma levels of NPA and MDO-NPA was possible at ranges of 2-1000 and 40-5000 ng/ml, respectively, including concentrations found after intravenous administration of these agents.  相似文献   

17.
A high-performance liquid chromatographic assay for determination of cefonicid concentrations in human plasma and urine samples has been developed using cefazolin as an internal standard. For the analysis of plasma samples two calibration curves were utilized covering the cefonicid concentration ranges of 0.05-1.0 microgram/ml and 1.0-50.0 micrograms/ml, respectively. Coefficients of variation of 7.4% or less were obtained for cefonicid concentrations of 0.05-50.0 micrograms/ml. Mean bias was +6.0% at 0.05 micrograms/ml cefonicid and between -2.1% and +1.6% for 1.0-50.0 micrograms/ml cefonicid. Plasma samples containing 30 ng/ml cefonicid could be well distinguished from blank plasma samples. Urine samples were analysed by using a calibration curve for cefonicid concentrations between 1.0 and 50.0 micrograms/ml. ranged from 8.6% at a cefonicid concentration of 1.0 microgram/ml to 0.5% at 50.0 micrograms/ml with a mean bias between -3.0% and +0.3%.  相似文献   

18.
A high-performance liquid chromatography (HPLC) assay was developed for the determination of estazolam in human plasma. Estazolam and alprazolam as an internal standard were detected by ultraviolet absorbance at 240 nm. Estazolam in plasma was extracted by a rapid and simple procedure based on cyanopropyl bonded-phase extraction. Chromatographic separation was achieved with a reversed-phase C8-5 column using a mobile phase of 0.5% potassium dihydrogenphosphate(pH 4.5)-acetonitrile (70:30, v/v). The determination of estazolam was possible in the concentration range of 1.0 - 200.0 ng/mL. The mean recovery of estazolam added to plasma was 96.1 +/- 1.5% with coefficients of variation of less than 5.5%. This method is applicable for accurately monitoring the plasma level of estazolam in healthy subjects participating in scientific research.  相似文献   

19.
A simple and precise high-performance liquid chromatographic procedure has been developed for the determination of temafloxacin and its trace level metabolites in biological matrices. Plasma samples are ultrafiltered after addition of an internal standard in a displacing reagent containing sodium dodecyl sulfate and acetonitrile. Plasma ultrafiltrates or diluted urines are chromatographed on a reversed-phase analytical column, using an ion-pair chromatographic mobile phase and fluorescence detection. The chromatographic system allows resolution and quantitation of temafloxacin's oxidative metabolites, which collectively account for less than 2% of the administered dose. The mean intra-assay coefficient of variation for determination of temafloxacin concentrations in plasma ranging from 0.05 to 10.0 micrograms/ml was 0.7%. The procedure was implemented at four laboratories for the analysis of over 12,000 samples from clinical studies. Inter-assay coefficients of variation estimated from routine analyses of quality control samples in these studies averaged 4% or lower for concentrations in the 0.15-10 micrograms/ml range. The limit of quantitation of the procedure is approximately 10 ng/ml; inter-assay coefficients of variation at 15 ng/ml averaged under 9%. Calibration curves were reproducible and highly linear, with correlation coefficients typically averaging over 0.9995. An alternative, more complex procedure, involving methylene chloride extraction, which extends the detection limits to below 1 ng/ml, is also described.  相似文献   

20.
An analytical method for the detection in biological samples of the novel tricyclic compound adosupine (10-acetoamido-5-methyl-5,6-dihydro-11H-dibenzo[b,e]azepin-6 ,11-dione), which is capable of influencing various forms of urinary bladder hyperreflexia has been developed using high-performance liquid chromatography with UV detection. Liquid-liquid extraction was used to isolate the parent compound, three metabolites and an analogue (added as internal standard) from plasma and brain of rat. Adosupine was well separated from its three metabolites with 0.01 M disodium hydrogenphosphate-acetonitrile-methanol-nonylamine (59.986:38:2:0.014) at pH 4.5 as mobile phase using a C18 reversed-phase column. The standard curves were linear in the range 50-5000 ng/ml (or ng/g) for adosupine and metabolites in both plasma and brain. The between- and within-assay variations for high and low concentrations of the parent compound and the three metabolites were 8.2-14%. In the range 50-5000 ng/ml (or ng/g) the accuracy of the method was satisfactory, with the relative error always lower than 10%. Analytical recoveries of added adosupine and the three metabolites were higher than 82%. The method has been applied successfully, to investigate the pharmacokinetics of the drug and its distribution in the central nervous system of rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号