首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
Determination of SARS-coronavirus by a microfluidic chip system   总被引:4,自引:0,他引:4  
Zhou X  Liu D  Zhong R  Dai Z  Wu D  Wang H  Du Y  Xia Z  Zhang L  Mei X  Lin B 《Electrophoresis》2004,25(17):3032-3039
  相似文献   

2.
Ho CT  Lin RZ  Chang WY  Chang HY  Liu CH 《Lab on a chip》2006,6(6):724-734
Biomimetic heterogeneous patterning of hepatic and endothelial cells, which start from randomly distributed cells inside the microfluidic chamber, via the chip design of enhanced field-induced dielectrophoresis (DEP) trap is demonstrated and reported in this paper. The concentric-stellate-tip electrode array design in this chip generates radial-pattern electric fields for the DEP manipulation of the live liver cells. By constructing the geometric shape and the distribution of stellate tips, the DEP electrodes enhance the desired spatial electric-field gradients to guide and snare individual cells to form the desired biomimetic pattern. With this proposed microfluidic chip design, the original randomly distributed hepatocytes inside the microfluidic chamber can be manipulated in parallel and align into the desired pearl-chain array pattern. This radial pattern mimics the lobular morphology of real liver tissue. The endothelial cells, then, are snared into the additional pearl-chain array and settle at the space in-between the previous hepatic pearl-chain array. By this cell-lab chip, we demonstrate the in vitro reconstruction of the heterogeneous lobule-mimetic radial pattern with good cell viability after cell patterning. This work reports the rapid in-parallel patterning of the dual types of live liver cells via the enhanced DEP trap inside the microfluidic chip.  相似文献   

3.
阵列式对电极介电电泳芯片及其用于细胞分离富集研究   总被引:2,自引:0,他引:2  
基于介电电泳原理, 设计并制作了一种新型的能够用于细胞分离和富集的微流控介电电泳芯片. 该芯片由沉积有金电极的石英基片和带有微管道的聚二甲基硅氧烷(PDMS)盖片组成. 通过在管道底部布置间距不同的对电极阵列, 增大了正介电电泳力在管道中的有效作用范围, 能够在降低施加电压的同时, 实现对流动体系中细胞样品的捕获. 在3 V和3 MHz条件下, 该DEP芯片对人血红细胞的捕获效率达到83%; 进一步通过将肝癌细胞捕获在芯片电极上可实现对红细胞和肝癌细胞混合样品的分离, 在5 V和400 kHz条件下对肝癌细胞的捕获效率达到86%.  相似文献   

4.
Electrochemical biosensors pose an attractive solution for point-of-care diagnostics because they require minimal instrumentation and they are scalable and readily integrated with microelectronics. The integration of electrochemical biosensors with microscale devices has, however, proven to be challenging due to significant incompatibilities among biomolecular stability, operation conditions of electrochemical sensors, and microfabrication techniques. Toward a solution to this problem, we have demonstrated here an electrochemical array architecture that supports the following processes in situ, within a self-enclosed microfluidic device: (a) electrode cleaning and preparation, (b) electrochemical addressing, patterning, and immobilization of sensing biomolecules at selected sensor pixels, (c) sequence-specific electrochemical detection from multiple pixels, and (d) regeneration of the sensing pixels. The architecture we have developed is general, and it should be applicable to a wide range of biosensing schemes that utilize gold-thiol self-assembled monolayer chemistry. As a proof-of-principle, we demonstrate the detection and differentiation of polymerase chain reaction (PCR) amplicons diagnostic of human (H1N1) and avian (H5N1) influenza.  相似文献   

5.
This work presents a promising clinical molecular diagnostics for early stage lung cancer. This novel diagnostic method utilized the loop-mediated isothermal amplification (LAMP), microfluidic chips and a confocal optical detector with a non-linear fluorescent filter processor. An isothermal amplification based microfluidic chip for the early diagnostics of lung cancer was developed and a confocal optical detector was improved by a novel real-time fluorescent filter to sensitively monitor the DNA amplification procedure with high signal to noise ratio and fluorescence collecting ability. Experiment showed that a rapid diagnostic of lung cancer by detecting the existence of the CEA mRNA could be performed in only 5 μL of reaction assay in less than 45 min. While the traditional in-tube RT-PCR set consumed more than 25 μL of the assay and took more than 90 min.  相似文献   

6.
A microfluidic chip for multistep manipulations of PMMA submicron particles (PMMA‐SMPs) based on dielectrophoresis (DEP) has been developed that includes four main functions of focusing, guiding, trapping, and releasing the SMPs. The structure of the DEP chip consists of a top electrode made of indium tin oxide, a flow chamber formed by optically clear adhesive tape and bottom electrodes with different patterns for different purposes. The bottom electrodes can be divided into three parts: a fish‐bone‐type electrode array that provides the positive DEP force for focusing the suspended nanoparticles (NPs) near the inlet in the flow chamber; the second is for switching and guiding the focused NPs along the electrode surface to the target area, like a flow passing along a virtual channel; and a trapping electrode in the downstream for trapping and releasing the guided NPs. According to the simulation and experimental results, NPs can be aligned along the electrode of the focusing electrode and guided toward the target electrode by means of a positive DEP force between the top and bottom electrodes, with the effects of Brownian motion and Stokes force. In order to demonstrate the sequence of DEP manipulations, a PMMA‐NP suspension is introduced to the DEP chip; the size of the PMMA‐SMPs is about 300 nm. Furthermore, a LabVIEW program developed for sequence control of the AC signals for the multistep manipulations. Consequently, the DEP chip provides an excellent platform technology for the multistep manipulation of SMPs.  相似文献   

7.
A nanoliter rotary device for polymerase chain reaction   总被引:17,自引:0,他引:17  
Liu J  Enzelberger M  Quake S 《Electrophoresis》2002,23(10):1531-1536
Polymerase chain reaction (PCR) has revolutionized a variety of assays in biotechnology. The ability to implement PCR in disposable and reliable microfluidic chips will facilitate its use in applications such as rapid medical diagnostics, food control testing, and biological weapons detection. We fabricated a microfluidic chip with integrated heaters and plumbing in which various forms of PCR have been successfully demonstrated. The device uses only 12 nL of sample, one of the smallest sample volumes demonstrated to date. Minimizing the sample volume allows low power consumption, reduced reagent costs, and ultimately more rapid thermal cycling.  相似文献   

8.
DNA analysis with the polymerase chain reaction (PCR) has become a routine part of medical diagnostics, environmental inspections, food evaluations, and biological studies. Furthermore, the development of a microscale PCR chip is an essential component of studies aimed at integrating PCR into a micro total analysis system (μ-TAS). However, the occurrence of air bubbles in microchannels complicates this process. In this study, we investigated a new technique based on the fluid dynamics of laminar flow that utilizes a small amount of mineral oil at the beginning of sample injection to prevent air bubbles from occurring in microchannels. We also further optimized the pressure, the length of the pressurizing channel and the volume of oil, thus making our microfluidic device more useful for high-temperature PCR. Additionally, quantitative continuous-flow PCR was performed using the optimized PCR chip in order to detect genetically modified (GM) maize. DNA was extracted from GM maize, MON 810, and non-GM maize at several concentrations from 0% (w/v) to 100% (w/v). The DNA amplification signals were then analyzed on the PCR chip using a laser-based system. The signal from our microfluidic PCR chip was found to increase in direct proportion to the initial GM maize concentration.  相似文献   

9.
The composition of the ship's ballast water is complex and contains a large number of microalgae cells, bacteria, microplastics, and other microparticles. To increase the accuracy and efficiency of detection of the microalgae cells in ballast water, a new microfluidic chip for continuous separation of microalgae cells based on alternating current dielectrophoresis was proposed. In this microfluidic chip, one piece of 3‐dimensional electrode is embedded on one side and eight discrete electrodes are arranged on the other side of the microchannel. An insulated triangular structure between electrodes is designed for increasing the inhomogeneity of the electric field distribution and enhancing the dielectrophoresis (DEP) force. A sheath flow is designed to focus the microparticles near the electrode, so as to increase the suffered DEP force and improve separation efficiency. To demonstrate the performance of the microfluidic separation chip, we developed two species of microalgae cells (Platymonas and Closterium) and a kind of microplastics to be used as test samples. Analyses of the related parameters and separation experiments by our designed microfluidic chip were then conducted. The results show that the presented method can separate the microalgae cells from the mixture efficiently, and this is the first time to separate two or more species of microalgae cells in a microfluidic chip by using negative and positive DEP force simultaneously, and moreover it has some advantages including simple operation, high efficiency, low cost, and small size and has great potential in on‐site pretreatment of ballast water.  相似文献   

10.
Detection of polymerase chain reaction (PCR) products obtained from cultured greenhouse fungal pathogens, Botrytis cinerea and Didymella bryoniae has been achieved using a previously developed microfluidic microarray assembly (MMA) device. The flexible probe construction and rapid DNA detection resulted from the use of centrifugal pumping in the steps of probe introduction and sample delivery, respectively. The line arrays of the oligonucleotide probes were “printed” on a CD-like glass chip using a polydimethylsiloxane (PDMS) polymer plate with radial microfluidic channels, and the sample hybridizations were conducted within the spiral channels on the second plate. The experimental conditions of probe immobilization and sample hybridization were optimized, and both complementary oligonucleotides and PCR products were tested. We were able to achieve adequate fluorescent signals with a sample load as small as 0.5 nM (1 μL) for oligonucleotide samples; for PCR products, we achieved detection at the level of 3 ng.  相似文献   

11.
12.
Won BY  Shin S  Baek S  Jung YL  Li T  Shin SC  Cho DY  Lee SB  Park HG 《The Analyst》2011,136(8):1573-1579
The operation of an electrochemical real-time PCR system, based on intercalative binding of methylene blue (MB) with dsDNA, has been demonstrated. PCR was performed on a fabricated electrode-patterned glass chip containing MB while recording the cathodic current peak by measuring the square wave voltammogram (SWV). The current peak signal was found to decrease with an increase in the PCR cycle number. This phenomenon was found to be mainly a consequence of the lower apparent diffusion rate of the MB-DNA complex (D(b) = 6.82 × 10(-6) cm(2) s(-1) with 612 bp dsDNA) as compared to that of free MB (D(f) = 5.06 × 10(-5) cm(2) s(-1)). Utilizing this signal changing mechanism, we successfully demonstrated the feasibility of an electrochemical real-time PCR system by accurately quantifying initial copy numbers of Chlamydia trachomatis DNA templates on a direct electrode chip. A standard calibration plot of the threshold cycle (C(t)) value versus the log of the input template quantity demonstrated reliable linearity and a good PCR efficiency (106%) that is comparable to that of a conventional TaqMan probe-based real time PCR. Finally, the system developed in this effort can be employed as a key technology for the achievement of point-of-care genetic diagnosis based on the electrochemical real-time PCR.  相似文献   

13.
14.
A sensitive electrochemical immunosensing chip is presented by employing (i) selective modification of protein‐resistant surfaces; (ii) fabrication of a stable Ag/AgCl reference electrode; (iii) capillary‐driven microfluidic control; (iv) signal amplification by redox cycling along with enzymatic reaction. Purely capillary‐driven microfluidic control is combined with electrochemical sandwich‐type immunosensing procedure. Selective modification of the surfaces is achieved by chemical reactivity‐controlled patterning and electrochemical deposition. Fluidic control of the immunosensing chip is achieved by spontaneous capillary‐driven flows and passive washing. The detection limit for mouse IgG in the immunosensing chip is 10 pg/mL.  相似文献   

15.
Dielectrophoretically driven microfluidic devices have demonstrated great applicability in biomedical engineering, diagnostic medicine, and biological research. One of the potential fields of application for this technology is in point-of-care (POC) devices, ideally allowing for portable, fully integrated, easy to use, low-cost diagnostic platforms. Two main approaches exist to induce dielectrophoresis (DEP) on suspended particles, that is, electrode-based DEP and insulator-based DEP, each featuring different advantages and disadvantages. However, a shared concern lies in the input voltage used to generate the electric field necessary for DEP to take place. Therefore, input voltage can determine portability of a microfluidic device. This review outlines the recent advances in reducing stimulation voltage requirements in DEP-driven microfluidics.  相似文献   

16.
Effective methods for rapid sorting of cells according to their viability are critical in T cells based therapies to prevent any risk to patients. In this context, we present a novel microfluidic device that continuously separates viable and non-viable T-cells according to their dielectric properties. A dielectrophoresis (DEP) force is generated by an array of castellated microelectrodes embedded into a microfluidic channel with a single inlet and two outlets; cells subjected to positive DEP forces are drawn toward the electrodes array and leave from the top outlet, those subjected to negative DEP forces are repelled away from the electrodes and leave from the bottom outlet. Computational fluid dynamics is used to predict the device separation efficacy, according to the applied alternative current (AC) frequency, at which the cells move from/to a negative/positive DEP region and the ionic strength of the suspension medium. The model is used to support the design of the operational conditions, confirming a separation efficiency, in terms of purity, of 96% under an applied AC frequency of 1.5 × 10Hz and a flow rate of 20 μl/h. This work represents the first example of effective continuous sorting of viable and non-viable human T-cells in a single-inlet microfluidic chip, paving the way for lab-on-a-chip applications at the point of need.  相似文献   

17.
Cheng JY  Hsieh CJ  Chuang YC  Hsieh JR 《The Analyst》2005,130(6):931-940
This study develops a novel temperature cycling strategy for executing temperature cycling reactions in laser-etched poly(methylmethacrylate) (PMMA) microfluidic chips. The developed microfluidic chip is circular in shape and is clamped in contact with a circular ITO heater chip of an equivalent diameter. Both chips are fabricated using an economic and versatile laser scribing process. Using this arrangement, a self-sustained radial temperature gradient is generated within the microfluidic chip without the need to thermally isolate the different temperature zones. This study demonstrates the temperature cycling capabilities of the reported microfluidic device by a polymerase chain reaction (PCR) process using ribulose 1,5-bisphosphate carboxylase large subunit (rbcL) gene as a template. The temperature ramping rate of the sample inside the microchannel is determined from the spectral change of a thermochromic liquid crystal (TLC) solution pumped into the channel. The present results confirm that a rapid thermal cycling effect is achieved despite the low thermal conductivity of the PMMA substrate. Using IR thermometry, it is found that the radial temperature gradient of the chip is approximately 2 degrees C mm(-1). The simple system presented in this study has considerable potential for miniaturizing complex integrated reactions requiring different cycling parameters.  相似文献   

18.
In this paper, we describe an amperometric-type enzymeless glucose sensing system based on a nanoporous platinum (Pt) electrode embedded in a microfluidic chip. This microchip system is comprised of a microfluidic transport channel network and a miniaturized electrochemical cell for nonenzymatic glucose sensing. Sample and buffer solutions were transferred to the cell by programmed electroosmotic flow (EOF). A nanoporous Pt electrode with the roughness factor of 200.6 was utilized to determine glucose concentrations in phosphate buffered saline (PBS) by the direct oxidation of glucose, without any separation process. The sensitivity of the developed system is 1.65 microA cm-2 mM-1 in the glucose concentration range from 1-10 mM in PBS.  相似文献   

19.
DNA biosensors based on nucleic acid hybridization processes are rapidly being developed towards the goal of rapid and inexpensive diagnosis of genetic and infectious diseases. Electrochemical transducers are often being used for detecting the DNA hybridization event, due to their high sensitivity, small dimensions, low cost, and compatibility with microfabrication technology. In this study, an electrochemical biosensor for the voltammetric detection of DNA sequences related to the Hepatitis B virus (HBV) and TT virus (TTV) from polymerase chain reaction (PCR) amplified real samples is described for the first time. The biosensor relies on the immobilization of the 21- or 24-mer single stranded oligonucleotides (probe) related to the HBV and TTV sequences and hybridization of these oligonucleotides with their complementary sequences (target) at carbon paste electrode (CPE). The extent of hybridization between the probe and target sequences was determined by using square wave voltammetry (SWV) with moving average baseline correction and methylene blue (MB) as the hybridization indicator. As a result of the interaction between MB and the bound guanine bases of hybrid at CPE surface, the MB signal decreased, when it was compared with the MB signal, which was observed with probe modified CPE. The difference between the MB signals, obtained from the hybrid modified and the probe modified CPE is used to detect the DNA sequences of the infectious diseases from PCR amplified real samples. Numerous factors affecting the target hybridization and indicator binding reactions are optimized to maximize the sensitivity.  相似文献   

20.
任苹  刘京  蔺日胜  刘杨  黄美莎  胡胜  徐友春  李彩霞 《色谱》2018,36(7):599-607
建立了常染色体单核苷酸多态性(SNPs)复合检测芯片体系,用于未知个体的族群来源推断。基于前期筛选的74-SNPs组合,采用竞争性等位基因特异性聚合酶链式反应(PCR)的原理构建SNPs的扩增体系,在微流控芯片的每个反应孔内完成一个SNP的检测,通过高通量PCR微流控芯片实现了其中72个SNPs的同步检测。芯片的扩增由平板PCR仪完成,反应孔的荧光信号通过激光共聚焦扫描仪检测,最终通过提取的荧光值进行结果分析。使用该芯片检测获得52份样本的SNPs分型,分型结果的准确率为100%。以57个人群的3628个样本为参考人群数据库,进行20份样本的族群来源推断,推断结果与样本的实际来源一致。本研究建立的常染色体72个SNPs微流控芯片体系可以有效地进行SNP多态性分析检测,基于参考数据库,20份检测样本族群推断的准确性为100%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号