首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A fluorescent single-domain antibody (fluobody), a fusion protein of a green fluorescent protein extracted from Aequorea coerulescens (AcGFP), a mutant that has been codon-optimized for mammalian expression, and a single-chain variable fragment antibody (scFv), against plumbagin (5-hydroxy-2-methyl-1,4-naphthoquinone; PL) was successfully constructed and expressed in Escherichia coli. The expressed fluobody was purified, refolded, and characterized to develop a speedy, simple, and sensitive fluorescence-linked immunosorbent assay (FLISA) for the determination of PL. In this study, two kinds of fluobody containing PL-scFv at the N-terminus of AcGFP (N fluobody) or the C-terminus of AcGFP (C fluobody) were constructed with flexible amino acid linker (Gly4Ser)2 between PL-scFv and AcGFP for comparative purposes. Characterization of the fluobodies revealed that the C fluobody has better properties as a probe for FLISA than the N fluobody because the fluorescence intensity of C fluobody was 18-fold higher than that of N fluobody. Moreover, C fluobody exhibited a fourfold-higher binding affinity than the N fluobody. More interestingly, the limit of detection for PL measurement in FLISA (24 ng mL−1) was improved to eightfold higher than that in conventional ELISA (0.2 μg mL−1), indicating that a sensitive immunoassay could be developed by using fluobody instead of monoclonal antibody or scFv.  相似文献   

2.
Plumbagin (PL; 5-hydroxy-2-methyl-1,4-naphthoquinone) is a natural compound mainly isolated from Plumbago zeylanica. This plant is distributed in Southeast Asia, and well known as Ayurvedic medicine in India for its medicinal properties. PL has been shown to have various pharmacological activities. We have successfully prepared monoclonal antibodies against PL, and developed an enzyme-linked immunosorbent assay (ELISA) system for determination of PL. 3-(5-Hydroxy-2-methyl-1,4-naphthoquinone-3-yl) propanoic acid was synthesized and purified to prepare PL-bovine serum albumin conjugate (PL-BSA), which was used as an immunogen. PL-BSA conjugate was administered into BALB/c male mice for production of monoclonal antibodies against PL. The monoclonal antibody against PL which is secreted from established hybridoma cell line 3A3 (MAb 3A3) has been proven to have highly-specific to PL resulting from cross-reactivities test. The range for calibration of PL by ELISA was 0.2-25 μg mL−1. Based on validation analysis, this analytical method by ELISA is a precise, accurate, and sensitive method for the determination of PL in plant.  相似文献   

3.
4.
Zhao MP  Li YZ  Guo ZQ  Zhang XX  Chang WB 《Talanta》2002,57(6):1205-1210
Bisphenol A and other hydroxylated diphenylalkanes (generally known as bisphenols) have been identified as potential estrogenic substances. In this paper, a specific polyclonal antibody was produced against these compounds by immunization of rabbits with a conjugate of 4,4-bis (4-hydroxyphenyl) valeric acid and bovine serum albumin (BHPVA-BSA). The polyclonal antibody showed specific recognition of the bisphenol structure, while the cross reactions of other common phenolic compounds such as phenol, hydroquinol and p-hydroxybenzoic acid were all lower than 1%. The linear range of bisphenol A calibration curve was 1–10 000 ng ml−1. Real water samples and mouse serum samples were spiked with known amount of bisphenol A and measured by the competitive ELISA. Recoveries were between 92 and 105%. The detection limits were found to be 0.1 ng ml−1 for real water samples and 2 ng ml−1 for serum samples. The method is very useful for monitoring bisphenol compounds in environmental and biological samples.  相似文献   

5.
We have developed a heterologous direct competitive enzyme-linked immunosorbent assay (ELISA) and a visual colloidal gold-based immunochromatographic assay (CGIA) for simultaneous determination of ofloxacin, marbofloxacin, and fleroxacin residues in milk using polyclonal antibodies. The half-maximum inhibition concentrations (IC50) of ofloxacin, marbofloxacin, fleroxacin, and limits of detection (LODs; calculated as IC15 values) are between 0.20 and 0.53?ng mL?1, and between 0.02 and 0.05?ng mL?1, respectively. The average recoveries range from of 78% to 113%, and the coefficients of variation of intra- and inter-assays are between 2 and 11%, and 3 to 19%, respectively. The LODs for ofloxacin, marbofloxacin, fleroxacin in milk are between 3.5 and 8.9?ng mL?1. The visual minimum detection limit of the optimized CGIA is 2?ng mL?1 for milk samples. The detection process can be completed within 10?min. The strips can be stored at 4?°C for 8?weeks without significant loss of activity. The results of the analysis of spiked samples showed that the CGIA can be applied to preliminary, fast, and on-site screening of milk samples. The ELISA and CGIA allow for a rapid, sensitive, and low-cost determination of (fluoro)quinolones residues in milk samples.
Figure
A direct competitive enzyme-linked immunosorbent assay (ELISA) and a visual colloidal gold-based immunochromatographic assay (CGIA) are proposed for simultaneous determination of ofloxacin, marbofloxacin, and fleroxacin residues in milk using polyclonal antibodies  相似文献   

6.
动力学荧光增敏法测定痕量钒(Ⅴ)   总被引:1,自引:0,他引:1  
研究了在稀硫酸介质中柠檬酸存在下,钒(Ⅴ)催化溴酸钾氧化吖啶红的荧光增强作用,建立了催化荧光法测定痕量钒(Ⅴ)的新方法。该方法的线性范围为0.20~3.00μg/L,检出限为0.04μg/L。本法已用于水样、大米和花生仁中痕量钒的测定。  相似文献   

7.
Dan Wang 《Talanta》2010,82(1):432-436
A simple competitive enzyme-linked immunosorbent assay (cELISA) was established for rapid measurement of secretory immunoglobulin A (sIgA) in saliva. The method was based on competitive reaction between the immobilized IgA and free IgA in the solution for the limited amount of horseradish peroxidase-conjugated rabbit anti-human IgA. In comparison with the conventionally used Sandwich ELISA, the cELISA is simpler, low-cost, and shows better reproducibility since it is not affected by the variation of capture antibodies from different batches. The assay time was also significantly reduced from more than 5 h to less than 3 h. Different curve-fitting models were compared, among which the fully specified logit-log model gave the best results. The linear working range and limit of detection were found to be 0.1-100 μg mL−1 and 0.05 μg mL−1, respectively. Matrix effects of saliva samples were investigated and a reasonable range of dilution factors were proposed. The developed method offers a very practical approach for high-throughput measurement of sIgA in saliva samples.  相似文献   

8.
9.
Watanabe H  Satake A  Kido Y  Tsuji A 《The Analyst》1999,124(11):1611-1615
Monoclonal antibodies (MAbs) against kanamycin were prepared by using a kanamycin-bovine gamma-globulin conjugate for the immunization of mice. Splenocytes from BALB/c immunized mice were fused with P3X63Ag8U.1 myeloma cells. This resulted in two hybridoma cell lines. Fifty per cent inhibition concentrations (IC50) for the MAbs were 2 and 5 ng ml-1. One MAb (IC50 = 2 ng ml-1) was named #22 and was used to develop quantitative assays for kanamycin by means of an enzyme-linked immunosorbent assay (ELISA). The detection limit was 0.2 ng ml-1 and the standard deviations were 0.2-4.4% for intra-assay and 0.6-4.7% for inter-assay, respectively. The detection limits using peroxidase were 4 ppb in cattle milk, cattle plasma, cattle urine, swine plasma, swine urine and chicken plasma. Using the MAb #22 produced, a rapid test kit based on an immunochromatographic method was developed. The detection limits using the kit were 50 ppb in cattle milk, cattle plasma, cattle urine and chicken plasma.  相似文献   

10.
Sensitive detection of pesticides is of utmost importance in environment and food analysis. Immunological methods are widely used to detect pesticides in agricultural and environmental samples wherein antibodies are employed against the target molecules. Accurate diagnosis depends on the affinity and specificity of the antibody preparation used, and high affinity antibodies are essential for the detection of very small amounts of pesticides. Enzyme linked immuno sorbent assay (ELISA) coupled with flow injection analysis (FIA) technique provides a very high sensitivity with high throughput of analyses. Automation of this analysis scheme ensures precise detection with high accuracy. The present development aims at providing a user-friendly system for achieving this objective. It employs a 8952 microcontroller for precise flow of reagents, samples, substrate and conjugates used for analysis to be passed through an immobilized antibody column at predetermined time. With the sequence and flow control of buffers used, it also provides the option for reuse of the immobilized antibody column. The system is flexible to accommodate multiple sequences up to a maximum of 99 steps. It is customizable for different flow ELISA applications. It can control up to eight solenoid valves (dc 24 V) and two peristaltic pumps and has one 12 bit analog channel for data acquisition. With the serial interface port, the system provides convenient means for data acquisition into the computer. The system has been successfully tested for immuno analysis of organophosphorous pesticide methyl parathion.  相似文献   

11.
A highly sensitive and specific enzyme-linked immunosorbent assay (ELISA) method has been developed for the determination of 20(S)-protopanaxatriol (PPT), one of the major aglycones of dammarane-type ginseng saponins. Polyclonal antibodies raised against ginsenoside F1 (GF1)-bovine serum albumin showed high reactivities to PPT and GF1, whereas they exhibited minor or even no cross-reactivities to other ginsenosides and protopanaxadiol (0.19%). The working range of this method extends from 50 pg ml−1 to 20 ng ml−1 of PPT. The assay reported here has been validated against an HPLC technique using PPT-containing samples and was shown to correlate closely (γ=0.993). This ELISA could be a useful tool for the determination of PPT contained in biological fluids and plant materials.  相似文献   

12.
A direct continuous fluorescence assay for translocase II MurG based on fluorescence resonance energy transfer (FRET) has been developed using a 6-substituted fluorescent analogue of UDP-N-acetylglucosamine.  相似文献   

13.
A specific polyclonal anti-norfloxacin antibody was obtained, and a sensitive indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed for determining trace amounts of norfloxacin in various waters. Good linearity was achieved in the range from 0.1 to 10 μg L−1. The average IC50 value was determined to be 2.2 μg L−1 and the limit of detection was 0.016 μg L−1 at a signal-to-noise ratio of 3 in phosphate-buffered saline buffer. Recoveries of norfloxacin at various spiking levels ranged from 74 to 105% in groundwater, surface water, treated and untreated wastewater samples, with relative standard deviations of 3–5%. The assay was applied for determining norfloxacin in municipal wastewater, surface water, and groundwater collected in a metropolis of China. Raw wastewater samples were only submitted to filtration and pH adjustment while the other water samples were pre-concentrated by solid phase extraction prior to the icELISA assay. Good agreement of the results obtained by the icELISA and liquid chromatography tandem mass spectrometry further confirmed the reliability and accuracy of the icELISA for rapid detection of norfloxacin in waters.  相似文献   

14.
Radoi A  Targa M  Prieto-Simon B  Marty JL 《Talanta》2008,77(1):138-143
Five different clones of antibodies developed against the aflatoxin M1 were investigated by using the classical indirect and direct competitive Enzyme-Linked Immunosorbent Assay (ELISA) formats, and also the direct competitive ELISA based on the use of the superparamagnetic nanoparticles. The purpose of this study was to assess if not so friendly time classical ELISA procedures can be further improved, by reducing the coating, blocking and competition time. Here we showed that a complete dc-ELISA (coating, blocking and competition step) based on the use of superparamagnetic nanoparticles can be performed in basically 40 min, if coating step (20 min) should be taken into account. Moreover, the standard analytical characteristics of the proposed method fulfil the requirements for detecting AFM1 in milk, in a wide linear working range (4-250 ng/L). The IC50 value is 15 ng/L. The matrix effect and the recovery rate were assessed, using the European Reference Material (BD282, zero level of AFM1), showing an excellent percentage of recovery, close to 100%.  相似文献   

15.
16.
Ju C  Tang Y  Fan H  Chen J 《Analytica chimica acta》2008,621(2):200-206
To set up an immunoassay-based method to detect Sudan dyes and Para red, we generated a monoclonal antibody (Mab) using a specially designed carboxyl derivative of Sudan I (CSD I) as the immunogen. CSD I was synthesized by azocoupling reaction using 2-naphthol and diazotised 4-aminobenzoic acid. The antibody was obtained from a hybridoma, which was derived from the fusion of the mouse myeloma SP2/0 cells and the splenocytes from the mice immunized with the CSD I-bovine serum albumin (BSA) conjugate. In addition, we showed that the Mab was highly specific for Sudan I, III and Para red. The limit of detection was approximately 0.01 ng mL−1 in phosphate-buffered saline (PBS) buffer and 0.5 ng g−1 in chilli tomato sauce. The recoveries of Sudan I, III and Para red for the chilli tomato sauce were from 84% to 99% and coefficients of variation were from 14.9% to 33.3%. Thus, the enzyme-linked immunosorbent assay (ELISA) method is a rapid and high throughput screening tool to detect Sudan dyes and Para red in food products.  相似文献   

17.
A new method describing direct attachment of carboxylated haptens on a polystyrene support, using 3-aminopropyltriethoxysilane (3-APTES) as a linker, is reported. The hapten coated polystyrene support showed excellent stability as a function of the buffer pH and reaction time, and was successfully used to demonstrate its application in enzyme-linked immunosorbent assay (ELISA).  相似文献   

18.
秦美君  郭丽敏  耿海琴  李赟 《分析试验室》2021,40(12):1370-1375
赭曲霉素A(OTA)是污染中药材的重要真菌毒素,严重影响中药材质量和用药安全.在小檗碱溶液中加入OTA和其核酸适配体后,处于随意卷曲状态的核酸适配体会被OTA诱导折叠成为G-四链体构象,使小檗碱的微环境发生改变,从而增强其荧光信号.基于此,本文以OTA核酸适配体为识别原件,小檗碱为荧光探针发展了一种无标记的荧光体系检测...  相似文献   

19.
4,4'-Isopropylidenediphenol, bisphenol A (BPA), was derivatized to BPA-carboxymethylether (BPA-CME), BPA-carboxypropylether (BPA-CPE) and BPA-carboxybutylether (BPA-CBE), and then linked to bovine serum albumin (BSA). The BPA-BSA conjugates were injected into female New Zealand White rabbits, which then generated six kinds of polyclonal antibodies. In addition, BPA and bisphenol B (BPB)-enzyme conjugates were derivatized to BPA-CME, BPA-CPE, BPA-CBE, BPA-carboxyphenylether (CPhE) and BPB-CPE, and then linked to horseradish peroxidase (HRP). An enzyme-linked immunosorbent assay (ELISA) was developed and the specificity of the antibodies was confirmed by comparison with pre-immune serum and by competitive assays using different dilutions of BPA standards. Although anti-BPA antibodies cross-reacted with BPB by more than 13.6% at all dilutions used, cross-reaction with phthalates and phenols occurred only less than 0.1%. The combination with the highest sensitivity was obtained using anti-BPA-CME-BSA antibody and BPA-CPhE-HRP conjugate. ELISA successfully detected BPA in human serum at concentrations as low as 0.3 ng mL(-1), and over a measurable range of 0.3-100 ng mL(-1). Recovery tests were carried out by adding BPA to three kinds of human serum, and ranged from 89.7 to 97.3%, from 85.4 to 94.9% and from 81.9 to 97.4%, respectively. The correlation between the results from ELISA and gas chromatography-mass spectrometry (GC-MS) for BPA in spiked serum was r2 = 0.990, indicating that the proposed method is a potential tool for screening a large number of human serum samples.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号