首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Application potentialities of CZE on-line coupled with capillary ITP and DAD to the identification and determination of trace concentration levels (microg/L) of pheniramine (PHM) enantiomers and their metabolites present in complex ionic matrices of biological origin (urine) are shown. An enhanced (enantio)selectivity of the CZE separation system obtained by the addition of carboxyethyl-beta-CD (CE-beta-CD) to the carrier electrolyte provided CZE conditions for a reliable identification of similar/identical DAD spectra of structurally related compounds (PHM enantiomers and their metabolites) in clinical urine samples differing in qualitative and quantitative composition of sample matrix constituents. A high sample loadability (a 30 microL sample injection volume), partial sample clean-up (removing macroconstituents from the sample), and preconcentration of the analytes in ITP stage resulted in the decrease of concentration LOD for PHM enantiomers in urine to 5.2 and 6.8 microg/L (2.2 x 10(-8) and 2.8 x 10(-8) mol/L), without using any sample pretreatment technique. The background correction and smoothing procedure applied to the raw DAD spectra provided analytically relevant DAD spectra of PHM enantiomers and their metabolites also when they were present in urine sample (30 microL injection volumes of ten-times diluted urine sample) at a 9 x 10(-) (8) mol/L concentration. DAD spectra of PHM enantiomers present in urine samples matched their reference spectra with reasonable certainties. DAD spectra of PHM metabolites were compared with the reference spectra of PHM enantiomers and a good match was found which indicates the similarities in the structures of enantiomers and their metabolites detected in the urine samples. This fact allows performing the quantitative analyses of PHM metabolites in the urine samples by applying the calibration parameters of PHM enantiomers also for PHM metabolites and the results show the possibilities of using the ITP-CZE-DAD combination for the direct analysis of PHM enantiomers and/or their metabolites in urine without any sample pretreatment. ITP-CZE-DAD method with oppositely charged selector is suggested to use in clinical research as it provides favorable performance parameters including sensitivity, linearity, precision, recovery, and robustness with minimal demands on sample preparation.  相似文献   

2.
The present work illustrated possibilities of column coupling electrophoresis combined with ionizable chiral selector and diode array detection (DAD) for the enantioselective analysis of trace drugs (pheniramine and its analogs) in pharmaceutical and clinical samples. Isotachophoresis (ITP), on-line coupled with capillary zone electrophoresis (CZE), served as an ideal injection technique (high sample load capacity, narrow and sharp drugs zones) of on-line pretreated samples (preseparation, purification and preconcentration of drugs) for the CZE stage. Enhanced (enantio)separation selectivity of CZE with ionizable chiral selector (carboxyethyl-beta-cyclodextrin recognized between drugs enantiomers on one hand as well as between drugs and sample matrix constituents on the other hand) enabled to obtain pure zones of the drugs enantiomers, suitable for their detection and quantitation. DAD in comparison with single wavelength UV detection enhanced value of analytical information verifying purity of drugs enantiomers zones (indicating interferents with different spectra to those of drugs). Obtained results indicated pure zones of interest confirming effective ITP-CZE (enantio)separation process. Distinguishing the trace analytes signals superposed on the baseline noise was provided with sufficient reliability (for this purpose the background correction and smoothing procedure had to be applied to the raw DAD spectra). The proposed ITP-CZE-DAD methods were characterized by favorable performance parameters (sensitivity, linearity, precision, recovery, accuracy, robustness, selectivity) and successfully applied for (i) enantiomeric purity testing of dexbrompheniramine in commercial pharmaceutical tablets and (ii) enantioselective metabolic study of pheniramine in human urine.  相似文献   

3.
The present study illustrates the possibilities of capillary isotachophoresis (CITP) online coupled with capillary zone electrophoresis (CZE) and hyphenated with fiber-based spectrophotometric diode array detection (DAD) for the direct, highly reliable, and ultrasensitive determination of quinine (QUI) in real multicomponent ionic matrices (beverages). Here, the CITP provided an effective online sample pretreatment (preseparation and preconcentration) prior to the CZE separation. Due to the CITP sample preconcentration, a simple UV-visible absorbance spectrophotometric detection was sufficient for obtaining very low concentration limits of detection (~2.3 ng/mL). Enhanced separation selectivity due to the combination of different separation mechanisms (CITP vs. CZE) enabled to obtain a pure analyte zone, suitable for its detection and quantitation in the directly injected real samples. The spectrophotometric DAD, unlike single wavelength UV detection, enabled to characterize the purity (i.e. spectral homogeneity) of the analyte zone and preliminary data indicate structurally related compounds via characteristic spectra recorded in the interval of 200-600 nm. The proposed CITP-CZE-DAD method was characterized by favorable performance parameters (sensitivity, linearity, precision, recovery, accuracy, robustness, and selectivity) and successfully applied to the control of QUI and potential QUI impurities in commercial beverages. This method is proposed as a routine automatized method for the highly reliable quality food control.  相似文献   

4.
Analytical capabilities of capillary zone electrophoresis (CZE) with on-line coupled capillary isotachophoresis (ITP) sample pretreatment in the column-coupling capillary electrophoresis equipment to separate and determine enantiomers present in multicomponent ionic matrices were studied. Tryptophan was used as a model analyte in the ITP-capillary zone electrophoresis experiments performed in this context while a 90-component model mixture of UV-light absorbing organic anions and urine served as multicomponent sample matrices. Various working modes in which the on-line coupled capillary isotachophoresis-capillary zone electrophoresis combination in the column-coupling separation system can operate were employed in the anionic regime of the separation with direct injections of the samples. Advantages and limitations of these working modes in the separations of enantiomers present in model and urine matrices were assessed. Experiments with model mixtures of tryptophan enantiomers revealed that the two were resolved in the capillary zone electrophoresis stage with the aid of alpha-cyclodextrin also when their concentration ratio in the sample was 1:200 while the concentration of L(-)-tryptophan was 25 nmol/l. The limits of detection for the enantiomers were at approximately 10 nmol/l (approximately 1.5 ng/ml) concentrations for a 220 nm detection wavelength of the UV detector employed in the capillary zone electrophoresis stage and for a 30 microliters sample load. A high sample load capacity of the on-line coupled capillary isotachophoresis stage was effective in separating the samples corresponding to 3-6 microliters volumes of undiluted urine. The results from the runs with urine samples showed that only the capillary isotachophoresis-capillary zone electrophoresis combination with a post-column on-line coupled capillary isotachophoresis sample clean-up (responsible for a removal of more than 99% of the sample anionic constituents migrating in the on-line coupled capillary isotachophoresis stack and detectable in the capillary zone electrophoresis stage) provided a universal alternative for the detection and quantitation of the model analyte (L(-)-tryptophan).  相似文献   

5.
The techniques of the on-line combination of capillary isotachophoresis with zone electrophoresis in two coupled capillaries (ITP-CZE) and a single capillary zone electrophoresis (CZE) were used for the sensitive determination of orotic acid (OA) in human urine. The simple CZE system was successfully applied for fast and reliable analyses of urine of healthy adult volunteers (the detection limit 1.7.10(-6) M OA, the total time of analysis 6 min). However, this method failed in analyses of OA in urine of ill children due to more complex matrix of the samples. Here, the ITP preconcentration and preseparation step coupled on-line with CZE proved to serve well with an electrolyte system developed and optimized for this purpose. The maximum selectivity and resolution of OA from other sample constituents in ITP-CZE was achieved by use of an electrolyte system of very low pH 2.15 both for ITP and CZE stage. The sensitivity of detection and simplicity of OA identification were enhanced by use of an external UV scanning detector. High sensitivity of ITP-CZE combination (limit of detection 3.10(-7) M OA), low sample consumption (1 microliter), good reproducibility of migration times (inter-day RSD < 1.86%) and acceptable reproducibility of the determination of OA in urine samples (average RSD = 7.27%) make this technique suitable for routine determination of trace concentration of OA especially in urine of ill children under various pathological conditions and medication.  相似文献   

6.
The ability of capillary zone electrophoresis (CZE) coupled on‐line with capillary isotachophoresis (ITP) sample pretreatment in the column‐coupling capillary electrophoresis equipment to separate trace enantiomers present in samples of complex ionic matrices and enantiomers present in their mixtures at significantly differing concentrations has been studied. Enantiomers of 2,4‐dinitrophenyl labeled norleucine (DNP‐Nleu) and tryptophan enantiomers were employed as model analytes in this work while urine and mixtures of tryptophan enantiomers of differing concentrations served as model samples. Experiments performed with urine samples spiked with the DNP‐Nleu racemate at sub‐μmol/L concentrations demonstrated excellent sample pretreatment capabilities of ITP (concentration of the analytes, in‐column and post‐column sample clean up) when coupled on‐line with chiral CZE separations. In the CZE separations of enantiomers present in the samples at trace concentrations the sample pretreatment could be performed in both achiral and chiral ITP electrolyte systems. The use of a chiral electrolyte system was found to be essential in the ITP pretreatment of the samples containing the enantiomers at very differing concentrations. For example, a 2×10–7 mol/L concentration of L‐tryptophan could be detected in the CZE separation stage of the ITP‐CZE combination in samples containing about a 104 excess of D‐tryptophan only when the ITP pretreatment was carried out in the electrolyte system providing the resolution of enantiomers (α‐cyclodextrin served for this purpose in the present work). A post‐column ITP sample clean up was found effective in enhancing the destacking rate of the trace enantiomer in the CZE stage when the migration configuration of the enantiomers was less favorable (the trace constituent migrating behind the major enantiomer).  相似文献   

7.
A new highly advanced analytical approach, based on two-dimensional column coupled CE (ITP-CZE) hyphenated with tandem mass spectrometry (MS/MS, here triple quadrupole, QqQ) was developed, evaluated and applied in biomedical field in the present work. Capillary isotachophoresis (ITP) coupled on-line with capillary zone electrophoresis (CZE) used in hydrodynamically closed separation system was favorable for increasing the sample load capacity, increasing the analyte concentration, and removing the deteriorative highly conductive major matrix constituents. These factors considerably reduced the concentration limits of detection (cLOD) and external sample preparation (comparing to single column CZE), and, by that, provided favorable conditions for the mass spectrometry (enhanced signal to noise ratio, reproducibility of measurements, working life of MS). Here, the CZE–ESI combination provided more effective interfacing than ITP–ESI resulting in both a higher obtainable intensity of MS detection signal of the analyte as well as reproducibility of measurements of the analyte’s peak area. The optimized ITP-CZE–ESI-QqQ method was successfully evaluated as for its performance parameters (LOD, LOQ, linearity, precision, recovery/accuracy) and applied for the direct identification and ultratrace (pg mL−1) determination of varenicline and, in addition, identification of its targeted metabolite, 2-hydroxy-varenicline, in unpretreated/diluted human urine. This application example demonstrated the real analytical potential of this new analytical approach and, at the same time, served as currently the most effective routine clinical method for varenicline.  相似文献   

8.
An on-line coaxial continuous-flow capillary-zone electrophoresis/fast-atom bombardment mass spectrometry (CZE/FAB-MS) interface is described. This interface is shown to be capable of acquiring mass spectra in an on-line fashion from low femtomole amounts of peptides while maintaining high (hundreds of thousands of plates) electrophoretic separation efficiencies. Active electrophoretic transport of the analytes directly to the FAB probe tip obviates the need for a transfer line from the end of the CZE capillary to this point, and thereby precludes the zone broadening that would otherwise occur both within such a transfer line and in the connections between the CZE column and the transfer line. The capability of acquiring an on-line tandem mass spectrometry (MS/MS) spectrum of an electrophoretically separated analyte using this interface is also demonstrated.  相似文献   

9.
An analytical method, based on a column coupling capillary ITP and CZE in a hydrodynamically closed separation mode hyphenated with the detection in the modular arrangement, was developed in this work. Analytical possibilities of this approach are demonstrated on the direct and ultrasensitive quantitative determination of quinine (QUI) in diluted real multicomponent ionic matrices (beverages, urine). The detection cell interface, with the rectangular arrangement of the optical channels inside, connected the separation capillary with the LIF detector via optical fibers in the on‐column detection arrangement. ITP enabled the direct large volume (30 μL) injections of the diluted real matrices with an on‐line sample pretreatment (preseparation, preconcentration) so that no external sample preparation (except for the dilution) was necessary for the separation of the analyte in the multicomponent ionic matrices. Due to the ITP sample preconcentration and intrinsic sensitivity of the LIF detection, very low concentration LOD (as low as 77 pg/mL), were reached at the same time. This was ca. two orders lower than the corresponding LOD achieved by the same 2D separation system with UV absorbance detection. Compared to the single column CE‐LIF methods applied for this model analyte and matrix, this method was found to be superior in terms of concentration LOD, with acceptable selectivity and benefits of the on‐line sample preparation. A food control and bioanalytical application clearly illustrates great practical possibilities and routine use of the proposed modular ITP–CZE–LIF technique.  相似文献   

10.
The relationships between electromigration dispersion (EMD) and on-line isotachophoresis-capillary zone electrophoresis (ITP-CZE) are described for several basic model proteins and interleukin-6 (rhIL-6). During CZE separation of the highly concentrated analyte zones which were generated during the initial ITP step EMD evolves from intrinsic differences in conductivity between the focused ITP zones and the leading electrolyte. Nearly triangular peaks with a sharp front and diffuse rear side were observed. An electromigration dispersion factor (FEMD) was introduced to measure peak asymmetry. EMD of individual peaks was shown to increase with the absolute amount of the respective analyte injected and with analyte mobility. Good linearity was observed when FEMD was plotted against protein mobility (r > 0.95). The slope of the graphs describing this relationship increased with the amount of analyte injected. The influence of EMD on the separation efficiency of neighboring peaks appeared to be less pronounced than expected. Consecutive release from the ITP-stack during transition from ITP to CZE might be an explanation for this observation.  相似文献   

11.
A new multidimensional analytical approach for the ultra‐trace determination of target chiral compounds in unpretreated complex real samples was developed in this work. The proposed analytical system provided high orthogonality due to on‐line combination of three different methods (separation mechanisms), i.e. (1) isotachophoresis (ITP), (2) chiral capillary zone electrophoresis (chiral CZE), and (3) triple quadrupole mass spectrometry (QqQ MS). The ITP step, performed in a large bore capillary (800 μm), was utilized for the effective sample pretreatment (preconcentration and matrix clean‐up) in a large injection volume (1–10 μL) enabling to obtain as low as ca. 80 pg/mL limits of detection for the target enantiomers in urine matrices. In the chiral CZE step, the different chiral selectors (neutral, ionizable, and permanently charged cyclodextrins) and buffer systems were tested in terms of enantioselectivity and influence on the MS detection response. The performance parameters of the optimized ITP – chiral CZE‐QqQ MS method were evaluated according to the FDA guidance for bioanalytical method validation. Successful validation and application (enantioselective monitoring of renally eliminated pheniramine and its metabolite in human urine) highlighted great potential of this chiral approach in advanced enantioselective biomedical applications.  相似文献   

12.
A feasibility study was performed using zone electrophoresis (ZE) coupled on‐line with isotachophoresis (ITP) sample pretreatment on a poly(methyl methacrylate) column‐coupling chip with integrated conductivity detection for direct determination of drugs in serum. Valproic acid (an antiepileptic drug), having a therapeutic range of 0.35–0.69 mmol/L (50–100 mg/L), was a test analyte while reference serum samples served as proteinaceous matrices. ITP provided in the ITP‐ZE combination a multitask sample pretreatment: (1) separation of the analyte from the serum matrix and its concentration into a narrow ITP band, (2) removal of the matrix constituents migrating in the ITP stack from the separation compartment of the chip, (3) ITP stacking of the drug released on a continuous electrophoretic decomposition of the drug‐protein complex. A high sample loadability, closely linked with the use of ITP in the first separation stage, made it possible to inject diluted serum samples with the aid of a 0.95 μL sample channel of the chip. Consequently, a 1–2 μmol/L concentration limit of quantitation for valproate from the response of the conductivity detector in the ZE stage of the combination was reached. The drug could be reliably determined in less than 10 minutes also in instances when its concentration in serum was below the lower value of the therapeutic range. 90–94% recoveries of valproate from serum samples were obtained in its direct ITP‐ZE determination when the filtration of the diluted serum (a 0.45 μm pore size filter) was the only pre‐column sample handling operation. No disturbances attributable to the precipitation of proteins from the loaded samples in the chip channels were detected.  相似文献   

13.
The possibility to apply charged chiral selector as buffer additive in capillary zone electrophoresis (CZE) on-line coupled with capillary isotachophoresis (CITP) was studied. Enantioseparations and determinations of trace (ng/ml) antihistaminic drugs [pheniramine (PHM), dimethindene (DIM), dioxopromethazine (DIO)] present in samples of complex ionic matrices (urine) served as model examples. A negatively charged carboxyethyl-β-cyclodextrin (CE-β-CD) was used as a chiral selector in analytical CZE stage following upon a sample pretreatment by CITP (preconcentration of the analytes from 5 to 20-times diluted urine samples, partial sample clean up removing macroconstituents from the sample matrices). A high recognition capability of the oppositely charged CE-β-CD was demonstrated by enantioselective retardation of the drugs in presence of micro-and semi-macroconstituents migrating in CZE stage and detectable by UV detector. In this way, enantiomers of the drugs could be easily separated and determined. Due to lack of interferences between the drugs and sample-matrix constituents in presence of charged CE-β-CD, demands on both spacers in CITP step and multiple column-switching were minimized. CITP-CZE method with charged selector appeared to be a useful analytical approach for the trace enantiomers in complex ionic matrices as it combined enhanced separation selectivity and sample loadabitlity with high separation efficiency and provided favorable performance parameters including sensitivity, linearity, precision, accuracy/recovery and robustness with minimal demands on sample preparation. Analysis of urine sample taken from a patient treated by PHM, showing concentration profile of PHM enantiomers and their metabolites, illustrated potentialities of the method in clinical research.  相似文献   

14.
The combination of capillary isotachophoresis (ITP) and capillary zone electrophoresis (CZE) in the column coupling configuration was optimized in a mode where the electrolyte for the CZE step is different from the leading and terminating ITP electrolytes. Two colored markers, picric acid and 1-nitroso-2-naphthol, were used for exact timing of the transfer of isotachophoretically stacked analyte zones into the CZE column and for the control of the residual amount of the leading and terminating ITP electrolytes entering the CZE capillary together with the analytes, thus controlling the duration of transient ITP migration in the CZE capillary and ensuring good separation of the analytes and reproducibility of the migration times (relative standard deviations 1%). ITP-CZE was applied to the simultaneous assay of several cinnamic acid derivatives and flavonoids in methanolic extracts of Sambucus flowers and Crataegus leaves and flowers. The preconcentrating and cleansing effect of the ITP step allowed injection of relatively large sample volumes (30 microL). The limits of detection were approximately 20-50 ng x mL(-1) and 100 ng x mL(-1) for the acids and flavonoids, respectively ( thick similar 200-times lower compared to conventional CE) with spectrophotometric detection at 254 nm. The ITP-CZE exhibited satisfactory linearity and precision when using CZE buffer of pseudo "pH" 9.0; 1-nitroso-2-naphthol was employed as the internal standard. The separation took approximately 35 min. The ITP-CZE results for rutin, hyperoside, and vitexin-2-O"-rhamnoside were in good accordance with those obtained previously by high-performance liquid chromatography.  相似文献   

15.
Summary The separation of the mycotoxins ochratoxin A, ochratoxin B, zearalenone and moniliformin by standard capillary zone electrophoresis (CZE) and cyclodextrins modified CE is described. In addition, reversed electroosmotic flow (EOF) conditions via quarternary ammonium running buffer additives have been briefly examined. Parameters influencing selectivity and mobility as well as spectroscopic properties of the analytes have also been investigated. Separations performed at pH values from 5 to 11 show a marked pH dependency of the mobilities accompanied by pronounced shifts of the UV/VIS and/or fluorescence spectra of the compounds. In general, the on-line recording of spectra by diodearray detection (DAD), proved to be highly versatile for peak tracking simultaneously with the structure elucidation and thus for the optimization of sample introduction, peak resolution and detection conditions.  相似文献   

16.
An Y  Cooper JW  Balgley BM  Lee CS 《Electrophoresis》2006,27(18):3599-3608
Besides the complexity in protein samples of biological origin, probably the greatest challenge presently facing comprehensive proteome analysis is related to the large variation of protein relative abundances (>6 orders of magnitude), having potential biological significance in mammalian systems. As demonstrated in this work, transient capillary ITP/zone electrophoresis (CITP/CZE) provides selective analyte enrichment through electrokinetic stacking and extremely high resolving power toward protein and peptide mixtures. The result of the CITP process is that major components may be diluted, but trace compounds are concentrated. The on-column transition of CITP to CZE minimizes additional band broadening while providing superior analyte resolution. Online coupling of transient CITP/CZE with nano-ESI-MS allows ultrasensitive detection of trace peptides at levels of subnanomolar concentration or subfemtomole mass in complex peptide mixtures. More importantly, selective enrichment of trace peptides enables the identification and sequence analysis of low-abundance peptides co-migrated with highly abundant species at a concentration ratio of 1:500,000. The combined CITP/CZE-nano-ESI-MS system is demonstrated to be at least one to two orders of magnitude more sensitive than that attained in conventional electrophoretic and chromatographic-based proteome technologies over a wide dynamic concentration range, potentially allowing comprehensive analysis of protein profiles within a small cell population and limited tissue samples using conventional mass spectrometers. Furthermore, the speed of CITP/CZE separation and the lack of column equilibration in CITP/CZE not only improve the throughput of proteome analysis, but also facilitate its seamless integration with other separation technologies in a multidimensional protein identification platform.  相似文献   

17.
The applicability of capillary zone electrophoresis (CZE) to ions having relatively low natural occurrences in sea water is limited by method's relatively poor concentration detection sensitivity. A combination of CZE with indirect UV detection and transient isotachophoresis (tITP) pre-concentration was developed to evolve the CZE practical utility towards the quantitative determination of the minor sea water cationic components, strontium and lithium. The ITP stacking criterion at the initial stage of a CZE separation was met by taking a highly mobile sodium, the principle matrix cation, to perform the role of a leading ion, whereas the moderately mobile sample macrocomponents, Ca2+ and Mg2+, acted as the terminating ion. The carrier electrolyte, consisting of 10 mM 4-methylbenzylamine and 1.5 mM citric acid at pH 4.8, was found to be optimal to accommodate both analyte cations in the ITP range and then separate them in the CZE mode, with relative standard deviations for migration times from 0.06-0.15% and for peak areas from 4-8%. The limits of detection were 1.3 mg l(-1) Sr2+ and 0.12 mg l(-1) Li+. The developed method was applied to the analysis of a surface sea water sample and a sea water reference material. The results were in good agreement with those obtained by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and electrothermal atomic absorption spectrometry (ET-AAS).  相似文献   

18.
The present work illustrates the potential of the capillary zone electrophoresis (CZE) separation technique coupled with the on-capillary diode array detector (DAD) for highly reliable determination of curcuminoids (curcumin, CUR, demethoxycurcumin, DCUR, and bisdemethoxycurcumin, BCUR) in substances (commercially available plant extract) and pharmaceutical preparation (commercial pharmaceutical capsules) with minimal sample preparation; (2-hydroxypropyl)-β-cyclodextrin (HP-β-CD) was chosen for an anionic separation of CUR and its structural analogues (DCUR and BCUR) as an appropriate complexing agent (i) providing complete resolution of the curcuminoids and (ii) reducing adsorption of these hydrophobic analytes onto the capillary wall. DAD detection was utilised for characterisation of the composition of the separated zones via differences in the corresponding UV-VIS spectra (scanned at interval of 200–800 nm). Reference and real spectra of the analytes demonstrated that the proposed separation method was sufficiently selective to produce well-separated (i.e. spectrally homogeneous) analyte zones with no interfering compounds present. Successful validation and application of the CZE-DAD method proposed here suggest its routine use in highly effective and reliable analysis of curcuminoids in pharmaceutical samples.  相似文献   

19.
Beckers JL 《Electrophoresis》2000,21(14):2788-2796
A sample stacking procedure to which a specific combination of electrolyte solutions is applied is isotachophoresis (ITP) superimposed on capillary zone electrophoresis (CZE), a so-called ITP/CZE system. In ITP/CZE some components migrate in an ITP fashion on top of a background electrolyte, and the other analytes migrate in a zone electrophoretic manner. For such a system, the leading electrolyte consists of a mixture of an ionic species, L1, of high mobility (the leading ion of the ITP system), an ionic species, L2, of low mobility (the coions of the CZE system), and a buffering counter-ionic species, whereas the terminating solution only contains the ionic species L2 and the buffering counterions. The zones of the components migrating in the ITP/CZE mode are sharp owing to the self-correcting properties of the zones and the concentrations of the L1 ions of the system. Mobility windows can be calculated, indicating which ions can migrate in the ITP/CZE mode. In this article mobility windows are calculated by applying both strong and weak acids as L1 and L2 ions and it appears that mobility windows can be optimized by chosing different ratios of L1 and L2 as well as different pH values. It is possible to construct very narrow mobility windows, and thereby choose which component of a sample solution can be concentrated, and to what concentration, in a very selective way. The big advantage of ITP/CZE compared with applications such as transient ITP and transient stacking is that the stacked sample ionic species migrate in the ITP mode during the whole experiment; furthermore, they do not destack. Experimentally obtained electropherograms validate the calculated mobility windows for the ITP/CZE mode.  相似文献   

20.
The use of capillary zone electrophoresis (CZE) on-line coupled with isotachophoresis (ITP) sample pretreatment (ITP-CZE) on a poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors, to the determination of bromate in drinking water was investigated. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the ITP-CZE separations. A high sample load capacity, linked with the use of ITP in this combination, made possible loading of the samples by a 9.2 microL sample injection channel of the chip. In addition, bromate was concentrated by a factor of 10(3) or more in the ITP stage of the separation and, therefore, its transfer to the CZE stage characterized negligible injection dispersion. This, along with a favorable electric conductivity of the carrier electrolyte solution, contributed to a 20 nmol/L (2.5 ppb) limit of detection for bromate in the CZE stage. Sample cleanup, integrated into the ITP stage, effectively complemented such a detection sensitivity and bromate could be quantified in drinking water matrices when its concentration was 80 nmol/L (10 ppb) or slightly less while the concentrations of anionic macroconstituent (chloride, sulfate, nitrate) in the loaded sample corresponding to a 2 mmol/L (70 ppm) concentration of chloride were still tolerable. The samples containing macroconstituents at higher concentrations required appropriate dilutions and, consequently, bromate in these samples could be directly determined only at proportionally higher concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号