首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
室内脉冲声场中声强的测量研究   总被引:1,自引:0,他引:1  
采用多次重复发射的声源配合装置在缓慢转动平台上的接收传声器所组成的测量系统(简称为RRS),它等效于多个完全匹配的传声器组成的圆型阵列。文中着重阐述了借助此技术测量房间内脉冲声场中声强的时间与空间分布特性。阐明了以RRS测量入射脉冲声强的理论基础,分别对离散的脉冲声场及扩散声场提出了测量声强的定量关系式,对实验结果及应用作了分析与讨论。  相似文献   

2.
A technique for the recording of large sets of room impulse responses or head-related transfer functions is presented. The technique uses a microphone moving with constant speed. Given a setup (e.g., length of the room impulse response), a careful choice of the recording parameters (excitation signal, speed of movement) leads to the reconstruction of all impulse responses along the trajectory. In the case of a moving microphone along a circle, the maximal angular speed is given as a function of the length of the impulse response, its maximal temporal frequency, the speed of sound propagation, and the radius of the circle. As a result of the presented algorithm, head-related transfer functions sampled at 44.1 kHz can be measured at all angular positions along the horizontal plane in less than 1 s. The presented theory is compared with a real system implementation using a precision moving microphone holder. The practical setup is discussed together with its limitations.  相似文献   

3.
The decay function for the evaluation of the reverberation time is often obtained by the method of the backward integration of a squared room impulse response as suggested by M.R. Schroeder more than four decades ago. Since then much work has been published about its implementation. However, soon after the initial exploitation of the method, it was realized that the effects of the background noise contaminating the room impulse response required a careful consideration for accomplishing better results.This paper describes an alternative method dealing with the problem of the backward integration of noisy room impulse responses. This method is based on the processing of two impulse responses sequentially recorded for a fixed source and receiver arrangement in a room. Statistical criteria are proposed to identify how the effect of the noise corrupts the level decay curve using a noise-free synthesized room impulse response as well as measurements performed in a real room.  相似文献   

4.
许凡  申雨晨  冯雪磊  沈勇 《应用声学》2021,40(2):200-212
在多输入多输出系统中,诸多情况下需并行测量任意输入输出之间的脉冲响应。虽然利用以Kasami序列集为代表的二元伪随机序列集良好的相关特性可以实现多声源并行测量,但是囿于其编解码信号相同且为二元信号的特点,使得其相关特性仍存在较大的可优化空间。该文提供了一种基于三元伪随机序列集的多声源房间脉冲响应测量方法,具有更好的相关特性,提高了测量准确度。仿真和实验验证了该测量方法的可行性和准确性。在封闭空间几何模型构建等领域中,可使用该方法提高测量效率并降低由于各通道不同步导致的误差。  相似文献   

5.
The modal expansion method has been used to formulate expressions for real and imaginary parts of the complex sound intensity inside enclosures. Based on theoretical results, the computer program has been developed to simulate the acoustic intensity vector field inside the irregular room whose shape resembles the capital letter L. Calculation results have shown that a low-frequency distribution of the acoustic intensity is strongly influenced by the modal localization and the characteristic objects in the active intensity field are energy vortices and saddle points positioned irregularly inside the room. It was found that for small sound damping the vortex centers lie exactly on the lines corresponding to zeros of the eigenfunction for a dominant mode. An increase in a sound attenuation results in the change of vortex positions and can cause the formation of new vortices. Finally, an influence of the wall impedance on the quantitative relation between the acoustic and reactive intensities was studied and it was concluded that for very small sound damping the behavior of the sound intensity is basically only oscillatory.  相似文献   

6.
简正波法是求解室内声场的一种较准确的数值计算方法,准确度由所取级数的项数而定,本文详细讨论了数值计算方法、级数的收敛性,并以图线来表明在声源点级数的发散及在声源附近计算的困难,本文还讨论声强测量的理论误差,用一般声强计在混响场中测量声强,误差是很大的,以致所得结果完全不可信任,如将传声器易位、前后两次测得的声强取平均,测量误差就可大大减小,若能采用精密仪器,使两个通道的相位差小于0.05°,则测量结果的统计误差可控制在合理范围内。  相似文献   

7.
A method is presented of measuring the free field frequency and impulse response of microphones by using a pulse technique in an ordinary laboratory environment. The pressure transient generated by exciting a loudspeaker with a narrow pulse is detected at some point in the loudspeaker's far field by a “reference” microphone whose response is assumed flat over the frequency range of interest. The microphone to be tested is then substituted in exactly the same position and its response to the transient measured. The outputs of the two microphones are accurately sampled and deconvolved by using a discrete Fourier transform technique to give the magnitude and phase parts of the “test” microphone's frequency response, and hence, via the discrete Fourier transform, its response to a delta function of pressure propagating in the free field. The computed impulse responses are presented and the accuracy of the method discussed.To illustrate the use of the method, the free field frequency response and free field correction curves of a one inch instrumentation microphone are measured. The method is then used to measure the pressure which occurs at the centre of the flat end-face of a long a cylinder when excited by an impulse of acoustic pressure propagating in the free field from various angles of incidence.  相似文献   

8.
The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and acoustic characteristics. The limitations in identifying the pivotal specular reflections of the geometrical acoustics model in measured room impulse responses are examined both theoretically and experimentally. The eigenmode method uses the theoretical expression for the Schroeder frequency and the difficulty of accurately estimating this frequency from the varying statistics of the room transfer function is highlighted. Reliable results are only obtained with the diffuse field model and a part of the observed variance in the experimental results is explained by theoretical expressions for the standard deviation of the reverberant sound pressure and the reverberation time. The limitations due to source and receiver directivity are discussed and a simple volume estimation method based on an approximate relationship with the reverberation time is also presented.  相似文献   

9.
王怀应 《应用声学》1998,17(3):15-19
本文介绍了强测量技术在水下结构辐射近场测量中的实际测量系统,特别是水下声系统的扫描平面的实现方法及定位误差控制方法,最后讨论和分析了实际测量结果,从而说明该系统用水下声强测量是可行的。  相似文献   

10.
This paper deals with the construction and characteristics of a specially designed wooden clapper intended to operate as an impulse sound source for measurements in rooms. It is to be used as an alternative impulse sound source for experimental estimations of impulse responses of rooms located at remote and specific places where none of the standard sound sources - an omnidirectional loudspeaker system, etc. - can be used. The paper describes the spectral characteristics and directivity of the clapper impulse. Its features are compared with other impulse sources.  相似文献   

11.
12.
We carry out an ultra-low-field nuclear magnetic resonance (NMR) experiment based on high-T c superconducting quantum interference devices (SQUIDs). The measurement field is in a micro-tesla range (~10 μT-100 μT) and the experiment is conducted in a home-made magnetically-shielded-room (MSR). The measurements are performed by the indirect coupling method in which the signal of nuclei precession is indirectly coupled to the SQUID through a tuned copper coil transformer. In such an arrangement, the interferences of applied measurement and polarization field to the SQUID sensor are avoided and the performance of the SQUID is not destroyed. In order to compare the detection sensitivity obtained by using the SQUID with that achieved using a conventional low-noise-amplifier, we perform the measurements using a commercial room temperature amplifier. The results show that in a wide frequency range (~1 kHz-10 kHz) the measurements with the SQUID sensor exhibit a higher signal-to-noise ratio. Further, we discuss the dependence of NMR peak magnitude on measurement frequency. We attribute the reduction of the peak magnitude at high frequency to the increased field inhomogeneity as the measurement field increases. This is verified by compensating the field gradient using three sets of gradient coils.  相似文献   

13.
The measurement of room impulse response (RIR) when there are high background noise levels frequently means one must deal with very low signal-to-noise ratios (SNR). If such is the case, the measurement might yield unreliable results, even when synchronous averaging techniques are used. Furthermore, if there are non-linearities in the apparatus or system time variances, the final SNR can be severely degraded. The test signals used in RIR measurement are often disturbed by non-stationary ambient noise components. A novel approach based on the energy analysis of ambient noise - both in the time and in frequency - was considered. A modified maximum length sequence (MLS) measurement technique, referred to herein as the hybrid MLS technique, was developed for use in room acoustics. The technique consists of reducing the noise energy of the captured sequences before applying the averaging technique in order to improve the overall SNRs and frequency response accuracy. Experiments were conducted under real conditions with different types of underlying ambient noises. Results are shown and discussed. Advantages and disadvantages of the hybrid MLS technique over standard MLS technique are evaluated and discussed. Our findings show that the new technique leads to a significant increase in the overall SNR.  相似文献   

14.
The problem of retrieving a complex function from the modulus of its Fourier transform has non-unique solutions in one dimension. Therefore iterative phase retrieval methods cannot in general be confidently applied to one-dimensional problems, due to the presence of ambiguities. We present a method for a posteriori reduction of the ambiguities based on the correlation analysis of the solution of a large number of runs of an iterative phase retrieval algorithm with different random starting phases. The method is applied to experimentally measured diffraction patterns from an x ray waveguide illuminated by hard x rays. We demonstrate the possibility of retrieving the complex wave field at the exit face of the waveguide and compare the result with theoretical prediction.  相似文献   

15.
16.
光纤扫描式激光光斑测量仪   总被引:1,自引:0,他引:1       下载免费PDF全文
 设计并开发了光纤扫描式激光光斑测量仪。光纤探头采用逐行扫描的方式对激光光斑进行扫描,采集的光信号经能量转换、数据采集,最终传输到电脑,再由软件绘制出光斑图像。针对于大口径、脉冲激光光斑的测量提出了一种快速扫描的方案,并在此基础上计算分析了仪器的测量精度和测量时间这两个重要参数。与CCD摄像法进行了对比实验研究,结果表明:相对于CCD摄像法会受到接收屏的散射及成像系统误差带来的影响;此设备采用直接测量的手段,能够更加准确地获得光斑的实际尺寸以及光斑能量的空间分布。应用该仪器成功地进行了聚焦光束传输质量的测量。  相似文献   

17.
在构建混响语声数据集时,由于缺乏真实长混响房间脉冲响应且模拟的房间脉冲响应与真实不符,因而导致数据驱动的混响时间盲估计模型性能下降。提出了一种基于条件生成对抗网络的房间脉冲响应模拟法,该方法利用真实的房间脉冲响应训练条件生成对抗网络,可以根据指定的混响时间模拟更加真实的房间脉冲响应。使用不同方法模拟的房间脉冲响应构建训练集用于训练盲估计模型,通过声学实验评估模型性能。实验结果表明,由该方法模拟的房间脉冲响应训练的估计模型在不同信噪比下均具有最小的均方根误差且在长混响情况下显著优于其他模型。  相似文献   

18.
测量了高强度三倍频实验的1ω 光和3ω 光的近场光束质量,将测量和模拟计算所得到3ω 光近场光束质量作了对比,重点对模拟计算得到的3ω 光近场光束质量所存在的误差进行了探讨,分析了现有的模拟计算程序中还未考虑到的影响3ω 光光束质量的主要因素,建议在以后的模拟计算程序中再进行优化设计,并讨论了改善3ω 光光束质量应采取的必要措施。  相似文献   

19.
Binaural room impulse responses (BRIRs) were measured in a classroom for sources at different azimuths and distances (up to 1 m) relative to a manikin located in four positions in a classroom. When the listener is far from all walls, reverberant energy distorts signal magnitude and phase independently at each frequency, altering monaural spectral cues, interaural phase differences, and interaural level differences. For the tested conditions, systematic distortion (comb-filtering) from an early intense reflection is only evident when a listener is very close to a wall, and then only in the ear facing the wall. Especially for a nearby source, interaural cues grow less reliable with increasing source laterality and monaural spectral cues are less reliable in the ear farther from the sound source. Reverberation reduces the magnitude of interaural level differences at all frequencies; however, the direct-sound interaural time difference can still be recovered from the BRIRs measured in these experiments. Results suggest that bias and variability in sound localization behavior may vary systematically with listener location in a room as well as source location relative to the listener, even for nearby sources where there is relatively little reverberant energy.  相似文献   

20.
Kang Yang 《中国物理 B》2022,31(7):70701-070701
For a magnetocardiography (MCG) system inside a magnetically shielded room (MSR), the residual field should be further suppressed to obtain high-quality MCG signals. In this paper, a compensation system has been developed based on the bi-planar coil and the proportional-integral-derivative (PID) controller. The bi-planar coil, derived from the target-field theory and the Tikhonov regularization method, is utilized to generate magnetic field with high uniformity in the pre-defined target region. And the PID controller is introduced to provide dynamic compensation current for the coil, according to the residual field change monitored by a reference SQUID magnetometer. The measurement results show that the noise suppression ratio (NSR) can reach above 20 dB in the low-frequency range from 0.1 Hz to 50 Hz. The DC component and the fluctuation of the residual field in time-domain can be respectively suppressed to 0 pT and 4 pT, indicating that this proposed compensation method is useful for the MCG measurement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号