首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
A new high-pressure liquid chromatography method with electrochemical detection is described that allows the simultaneous determination of dopamine, serotonin, 3,4-dihydroxyphenylacetic acid, 3-methoxy-4-hydroxyphenylacetic acid, 5-hydroxytryptophan and 5-hydroxyindoleacetic acid in microdissected nuclei from individual rat brains. No sample pre-treatment steps are required. Resolution and analysis time were optimized by a simple limited optimization procedure, involving two-parameter factorial design.  相似文献   

2.
A combined procedure based on reversed-phase liquid chromatography with electrochemical detection has been developed for the determination in the picomole range of the monoamines dopamine, norepinephrine, epinephrine and serotonin, and their major metabolites 3,4-dihydroxyphenylacetic acid, homovanillic acid, 3-methoxy-4-hydroxyphenylethylene glycol, 5-hydroxyindoleacetic acid, normetanephrine, metanephrine and 3-methoxytyramine. Sample pretreatment consists of the extraction of the neutral and acidic metabolites with ethyl acetate, followed by the extraction into heptane of the catecholamines with tetraoctylammonium bromide as counter-ion in the presence of diphenylborate. The residual supernatant is directly injected in the chromatographic system for quantification of serotonin, normetanephrine, metanephrine and 3-methoxytyramine.  相似文献   

3.
The effects of pH, ionic strength, organic modifier, heptanesulphonic acid and citric acid content of a high-performance liquid chromatography mobile phase on the chromatographic and electrochemical behaviour of norepinephrine, epinephrine, dopamine, 3,4-dihydroxybenzylamine, 3,4-dihydroxyphenylethylene glycol, 3,4-dihydroxyphenylalanine and 3,4-dihydroxyphenylacetic acid in a reversed-phase system have been systematically studied. Optimal mobile phase conditions have been derived allowing the separation and reductive-mode detection of these compounds, applicable to both alumina and ion-paired solvent extracts of plasma. It is demonstrated that mobile phase composition significantly affects the sensitivity of a triple-electrode electrochemical detection system, in reductive and oxidative modes, and that electrochemical pre-treatment of mobile phase is required to attain maximum detector sensitivity in the reductive mode.  相似文献   

4.
The commercially available computer program, Drylab, for optimization of separations by high-performance liquid chromatography (HPLC) using binary solvent mixtures is used to improve an HPLC method for separation of the bitter principle, limonin, in grapefruit and navel orange juices. Best conditions for separation of limonin in a reasonable time are 30 to 32% acetonitrile in water at 0.9 mL/min using a 5-micron C18 column 10 cm long. These conditions are used to analyze grapefruit and navel orange juice samples, and these HPLC results are compared with values determined by enzyme immunoassay or thin-layer chromatography (TLC) on the same samples.  相似文献   

5.
A procedure for determining human platelet monoamine oxidase (MAO) with dopamine (DA) as substrate is described. High-performance liquid chromatography (HPLC) with electrochemical detection (ED) was used to separate and detect components of the reaction mixture. The method for platelet preparation was also improved and only 2 ml of blood were required. Following a 10-min incubation of the platelet preparation with DA in 0.1 M Tris buffer (pH 9.0), excess DA substrate was removed by adsorption on a cation-exchange resin. The reaction product, 3,4-dihydroxyphenylacetaldehyde, was adsorbed on acid-washed alumina, eluted with 0.1 M perchloric acid and analyzed by HPLC. Simple, clean chromatograms were obtained with good reproducibility using 3,4-dihydroxybenzylamine as an internal standard. The within-sample, between-samples and between-day relative standard deviations were 0.9, 3.7 and 6.1%, respectively. The apparent Michaelis constant and maximum velocity were 0.10 mM and 0.37 nmol/min.mg protein, respectively. This HPLC-ED method offers a good alternative to methods using radioactivity.  相似文献   

6.
赵燕燕  刘丽艳  韩媛媛  白洁  杜光玲  高茜 《色谱》2011,29(2):146-151
采用高效液相色谱-荧光检测法同时测定了大鼠不同脑区中的左旋多巴、去甲肾上腺素、肾上腺素、多巴胺、二羟基苯乙酸、5-羟色胺、5-羟基吲哚乙酸及高香草酸8种单胺类神经递质的含量。样品经组织裂解液(0.60 mol/L高氯酸、0.50 mmol/L Na2EDTA、0.1 g/L L-半胱氨酸的混合水溶液)处理后,冷冻离心得到上清液;上清液中加入高氯酸沉淀剂(1.20 mol/L K2HPO4、2.00 mmol/L Na2EDTA的混合水溶液)处理后,冷冻离心、过滤。在该优化的色谱条件下,8种单胺类神经递质在1.25~5000 μg/L范围内线性关系良好(r>0.9999),最低检出限在0.20~5.00 μg/L之间,平均回收率在94.83%~99.19%之间,相对标准偏差在0.08%~2.51%之间。该方法具有操作简便、快捷、回收率高、检出限低、分离度好、结果准确可靠等优点,可以用于体内8种单胺类神经递质的同时检测与分析。  相似文献   

7.
A highly selective and sensitive high-performance liquid chromatographic method for the determination of catecholamines (norepinephrine, epinephrine and dopamine) and related compounds (L-DOPA, normetanephrine, metanephrine, 3-methoxytyramine, 3,4-dihydroxymandelic acid, 3,4-dihydroxyphenylacetic acid, homovanillic acid, vanillylmandelic acid, 3,4-dihydroxyphenylethylene glycol, 4-hydroxy-3-methoxyphenylethylene glycol and 4-hydroxy-3-methoxyphenylethanol) with a post-column technique involving coulometric oxidation followed by fluorescence derivatization is described. These compounds, 3,4-dihydroxybenzylamine and ferulic acid are separated within 35 min by ion-pair reversed-phase chromatography using acidic buffers (pH 3.1) with methanol-acetonitrile (3:2, v/v) gradient elution, and then oxidized by a commercial coulometric detector to the corresponding o-quinones, which are converted into fluorescent derivatives by reaction with 1,2-diphenylethylenediamine. The detection limits (signal-to-noise ratio = 3) on-column are 1.5-4 pmol for the two mandelic acids, 600 fmol for L-DOPA and 20-70 fmol for the others.  相似文献   

8.
A simple and sensitive procedure for simultaneous determination of monoamine transmitters and related substances including precursors and metabolites has been developed for a single mouse brain. The proposed procedure involves (1) primary butanol extraction, (2) separation of the substances into either acid or alkaline aqueous layers according to their physicochemical properties, and (3) determination by means of high-performance liquid chromatography with electrochemical detection. Three transmitters (noradrenaline, dopamine and 5-hydroxytryptamine) and their precursors (tyrosine, 3,4-dihydroxyphenylalanine and tryptophan) and major metabolites (normethanephrine, 3-methoxy-4-hydroxyphenylethylene glycol, 3-methoxytyramine, 3,4-dihydroxyphenylacetic acid, 3-methoxy-4-hydroxyphenylacetic acid and 5-hydroxyindoleacetic acid) were selectively separated and sensitively detected in mouse whole brain sample. Although 3-methoxy-4-hydroxymandelic acid was also separated from other substances by authentic chromatography, the substance was not detected in mouse brain. Changes in levels of these substances were examined for drugs whose effects had been previously confirmed. These changes reflected putative effects of the drugs and confirmed that the procedure is effective for neurochemical research into the transmitter system.  相似文献   

9.
Summary Formal procedures used for optimizing chromatographic selectivity require objective, numerical functions to assess the quality of each chromatogram obtained during the process. Many of such optimization criteria have been suggested for chromatograms in which all or a number of well-shaped peaks need to be separated. This paper describes a method by which resolution can be measured in chromatograms in which very large, highly non-symmetrical background peaks,e.g. typical solvent peaks, are present. Using this method, various optimization criteria can be calculated. The method is evaluated using a simulation program which constructs chromatograms from the recorded profiles of individual experimental peaks. It is also demonstrated for use in an experimental optimization procedure in reversed-phase liquid chromatography.  相似文献   

10.
The Aria LX4 staggered parallel high performance liquid chromatography (HPLC) system is evaluated for application to good laboratory practice (GLP) level quantitative analysis by liquid chromatography/tandem mass spectrometry (LC/MS/MS). This system consists of four fully independent binary HPLC pumps, a modified autosampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Validation results for four different compounds, each analyzed on a separate channel of the Aria system, show precision and accuracy equivalent to that required of a single-channel system. The results show that sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The flexibility and ease of use of the Aria system suggest that it should be possible to quickly implement it in any analytical LC/MS/MS environment.  相似文献   

11.
An appropriate optimization strategy should be used to find a desired resolution or selectivity with a minimum number of experiments in a limited time, which could assure the baseline separation of all target compounds. It was usually realized by means of a specialized computer program. In this paper, mapping optimization method and overlapping resolution mapping were compared for the optimization of a reversed-phase high-performance liquid chromatography (HPLC) isocratic separation of neutral compounds. The calculated resolutions and separation time of 7 to 10 experiments are fitted by different equations, which were used to build a contour plot with a minimum effective resolution and maximum retention time as a function of a mobile phase composition. The balance between resolution and analysis time could be easily realized by the overlapping of the final overlapping resolution mapping and analysis time mapping. The validity of the two methods was confirmed by some typical experiments. The models are simple, visual, and common without theoretical arithmetic.  相似文献   

12.
A combined extraction system for the selective and quantitative isolation of the monoamines norepinephrine, epinephrine, dopamine, serotonin (5-hydroxytryptamine) and their metabolites 3-methoxy-4-hydroxyphenylethylene glycol, 3,4-dihydroxyphenylacetic acid, 5-hydroxyindoleacetic acid, homovanillic acid and 3-methoxytyramine from one single brain tissue sample is described. The extraction system is a combination of an ethyl acetate extraction for 3-methoxy-4-hydroxyphenylethylene glycol, 3,4-dihydroxyphenylacetic acid, 5-hydroxyindoleacetic acid and homovanillic acid, and two successive ion-pair extractions. In a first step, the catecholamines are quantitatively isolated by extracting with heptane--octanol (99:1) containing 0.25% tetraoctylammonium bromide as an ion-pairing agent in the presence of 0.2% diphenylborate. In a second step, 3-methoxytyramine and 5-hydroxytryptamine are isolated from the aqueous phase with di(2-ethylhexyl)phosphoric acid as counter-ion in chloroform. Dihydroxybenzylamine, isohomovanillic acid and 5-hydroxy-N-methyltryptamine are used as the internal standards.  相似文献   

13.
In this paper, a fast strategy for determining the total antioxidant capacity of Chinese green tea extracts is developed. This strategy includes the use of experimental techniques, such as fast high-performance liquid chromatography (HPLC) on monolithic columns and a spectrophotometric approach to determine the total antioxidant capacity of the extracts. To extract the chemically relevant information from the obtained data, chemometrical approaches are used. Among them there are correlation optimized warping (COW) to align the chromatograms, robust principal component analysis (robust PCA) to detect outliers, and partial least squares (PLS) and uninformative variable elimination partial least squares (UVE-PLS) to construct a reliable multivariate regression model to predict the total antioxidant capacity from the fast chromatograms.  相似文献   

14.
The computer package calculates the coefficients of the terms of orthogonal polynomial series used to approximate the analytical signal. Two different polynomial series (Hermite and Chebyshev) are used, depending on the number of peaks and spreading of the error of the approximation over the interval. The package is applied for data reduction and filtering of the analytical signal. Part of the package facilitates optimization in chromatography, by calculating the effect of varying chromatogram parameters on polynomial terms. Some scaling methods for the analytical signal are discussed. For testing purposes, a program that generates chromatograms is added to the computer package. The program simulates chromatographic peaks with user-defined peak parameters; noise can be added. The theoretical background is described and some results are presented.  相似文献   

15.
A four-step development, optimization and validation strategy for high-performance liquid chromatography (HPLC) fingerprints of Ginkgo biloba extract is described. A suitable chromatographic system was selected first. The following step was performing a screening design to select important parameters. After selecting some controllable parameters and their range to further optimize, gradient optimization with uniform design was done. At last, method validation including determination of injection precision, repeatability, and a sample stability test, was performed. Through this effective and integrated four-step method, a feasible and reliable HPLC fingerprint to identify and assess the Ginkgo biloba quality can easily be established using a linear gradient elution with acetonitrile/0.1% phosphoric acid (from 14/86 to 30/70, v/v, in 40 min) as mobile phase, a column temperature of 30 degrees C and a detection wavelength of 350 nm. The strategy can also be applied for the development of fingerprints in the quality control of other herbal medicines.  相似文献   

16.
A high-resolution high-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry method is described for the analysis of porphyrins in blood, urine and faeces. The gradient elution reversed-phase HPLC system using acetonitrile-methanol-1 m ammonium acetate/acetic acid buffer (pH 5.16) as gradient solvent mixtures was able to separate all porphyrin metabolites, including the type I and type III isomers of uroporphyrin, hepta-, hexa- and penta-carboxylic acid porphyrins and coproporphyrin. The porphyrins were positively identified by the protonated molecules [M+H](+) and further characterized by tandem mass spectrometric analysis with each porphyrin giving a characteristic collisioninduced dissociation product ion spectrum. The mass chromatograms obtained by HPLC/ESI MS are useful for the differential diagnosis of the porphyrias, since each type of porphyria has a typical porphyrin excretion pattern.  相似文献   

17.
《Analytical letters》2012,45(8):1691-1709
ABSTRACT

The separation selectivity of eighteen phenolic derivatives in micellar high-performance liquid chromatography was studied as a function of parameters on which it depends: surfactant and organic modifier concentration. The surfactant used in this study was cetyltrimethylammonium bromide, and as organic modifier methanol. An iterative regression optimization strategy for these two parameters has been used. The equation that best explains the experimental

results is 1/k' = A +Bμ + Cφ + DμΦ. We propose the use of this model in conjunction with the appropriate factorial design to predict the solute retention behaviour in micellar liquid chromatography with hibrid eluents.  相似文献   

18.
High‐speed countercurrent chromatography combined with preparative high‐performance liquid chromatography was successfully used to separate seven phenolic compounds from Stenoloma chusanum Ching. A biphasic solvent system composed of hexane/ethyl acetate/methanol/water (1:2:1:2, v/v) was used for the first step high‐speed countercurrent chromatography separation in elution–extrusion mode. A mobile phase composed of acetonitrile (18%) and pure water (82%) was used for further preparative high‐performance liquid chromatography purification. In total, the combined separation yielded seven compounds, including 3,4‐dihydroxy benzoic acid, 3,4‐dihydroxy benzaldehyde, esculetin, caffeic acid, syringic acid, luteolin, and apigenin, at a purity of over 90%. Esculetin was separated from Stenoloma chusanum Ching for the first time. The results suggest that the proposed combination method is a useful strategy for separating compounds from complex samples.  相似文献   

19.
The addition of an ionic liquid into the mobile phase appeared to be useful in optimization of chromatographic separation of peptides. Different behavior of peptides in thin-layer chromatography (TLC) was observed after addition of 1-ethyl-3-methylimidazolium tetra fluoroborate to the eluent in comparison to the system without the ionic liquid. Nonlinear dependence of the retention coefficient, R(M), of peptides on the volume percentage of acetonitrile in the eluent was found in normal-phase TLC with and without immidazolium tetra fluoroborate in the mobile phase. In general, R(M) increased with increasing concentration of acetonitrile. In TLC systems without the ionic liquid, R(M) can be described well with a quadratic function. On the other hand, in a TLC system with an ionic liquid as the additive to the mobile phase, the retention behavior is better described with a third-degree polynomial function. The potential usefulness of ionic liquids for optimization of separation of peptides was demonstrated. Optimization of the separation conditions was supported by a commercially available computer program.  相似文献   

20.
The optimization of an ultrasound-assisted extraction (UAE) method for tartaric and malic acids from grape derived samples is shown. A fractional factorial experimental design allowed for the determination of the effects of seven extraction variables. Relationships between all the variables were examined. By applying graphical analysis, the best extractions conditions were obtained. The most important variables were the extracting liquid and the extraction temperature. Later, a central composite design was applied for optimizing the temperature and the composition of the extracting liquid. The optimized method was applied to grapes and to winemaking by-products. The repeatability of the method was studied and the recovery of tartaric and malic acids was established. Organic acids quantification was done by liquid chromatography (LC) using a post-column buffer and a conductivity detector.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏