首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
Fluorescence lifetime imaging microscopy (FLIM) is a new methodology for studying the spatial and temporal dynamics of macromolecule, molecules, and ions in living cells. In FLIM image contrast is derived from the mean fluorescence lifetime at each point in a two-dimensional image. In our case the lifetime was measured by the phase-modulation method. We describe our FLIM apparatus, which consists of a fluorescence microscope, high-speed gated proximity focused MCP image intensifier, and slow-scan CCD camera. To accomplish subnanosecond time-resolved imaging, the gain of the image intensifier is modulated with a high-frequency signal, resulting in stationary phase-sensitive intensity images on the image intensifier. These images are recorded using a cooled slow-scan CCD camera and stored in an image processor. The lifetime images are created from a series of phase-sensitive images at various phase shift of the gain-modulation signal. We demonstrate calcium concentration imaging in living COS cells based on Ca2+-induced lifetime changes of Quin-2. The phase-angle image is mapped to the Ca2+ concentration image using anin vitro-determined calibration curve. The Ca2+ concentration was found to be uniform throughout the cell. In contrast, the intensity image shows significant spatial differences, which likely reflect variations in the thickness and distribution of probe within the cell.  相似文献   

2.
刘雄波  林丹樱  吴茜茜  严伟  罗腾  杨志刚  屈军乐 《物理学报》2018,67(17):178701-178701
由于荧光寿命不受探针浓度、激发光强度和光漂白效应等因素影响,荧光寿命显微成像技术(fluorescence lifetime imaging microscopy, FLIM)在监测微环境变化、反映分子间相互作用方面具有高特异性、高灵敏度、可定量测量等优点,近年来已被广泛应用于生物医学等领域.然而,尽管FLIM的发明和发展已历经数十年时间,其在实际应用中仍然面临着许多挑战.例如,其成像分辨率受衍射极限限制,而其成像速度与成像质量和寿命测量精度则存在相互制约的关系.近几年来,相关硬件和软件的快速发展及其与其他光学技术的结合,极大地推动了FLIM技术及其应用的新发展.本文简要介绍了基于时域和频域的不同寿命探测方法的FLIM技术的基本原理及特点,在此基础上概述了该技术的最新研究进展,包括其成像性能的提升和在生物医学应用中的研究现状,详细阐述了近几年来研究者们通过硬件和软件算法的改进以及与自适应光学、超分辨成像技术等新型光学技术的结合来提升FLIM的成像速度、寿命测量精度、成像质量和空间分辨率等方面所做的努力,以及FLIM在生物医学基础研究、疾病诊断与治疗、纳米材料的生物医学研究等方面的应用,最后对其未来发展趋势进行了展望.  相似文献   

3.
Ca2+ concentrations in biological cells are widely studied with fluorescent probes. The probes have a high selectivity for free calcium and exhibit marked changes in their photophysical properties upon binding. The differences in the fluorescent lifetime of the probes can now be used as a contrast mechanism for imaging purposes. This technique can be further exploited for the quantitative determination of ion concentrations within the cells. We describe the use of a fast fluorescence lifetime imaging method in combination with a standard confocal laser scanning microscope for the determination of Ca2+ concentrations in single rat cardiac myocytes using the intensity probe Calcium Green.  相似文献   

4.
This article describes the design and characterization of a wide-field, time-domain fluorescence lifetime imaging microscopy (FLIM) system developed for picosecond time-resolved biological imaging. The system consists of a nitrogen-pumped dye laser for UV–visible–NIR excitation (337.1–960 nm), an epi-illuminated microscope with UV compatible optics, and a time-gated intensified CCD camera with an adjustable gate width (200 ps-10-3 s) for temporally resolved, single-photon detection of fluorescence decays with 9.6-bit intensity resolution and 1.4-μm spatial resolution. Intensity measurements used for fluorescence decay calculations are reproducible to within 2%, achieved by synchronizing the ICCD gate delay to the excitation laser pulse via a constant fraction optical discriminator and picosecond delay card. A self-consistent FLIM system response model is presented, allowing for fluorescence lifetimes (0.6 ns) significantly smaller than the FLIM system response (1.14 ns) to be determined to 3% of independently determined values. The FLIM system was able to discriminate fluorescence lifetime differences of at least 50 ps. The spectral tunability and large temporal dynamic range of the system are demonstrated by imaging in living human cells: UV-excited endogenous fluorescence from metabolic cofactors (lifetime ∼1.4 ns); and 460-nm excited fluorescence from an exogenous oxygen-quenched ruthenium dye (lifetime ∼400 ns). Received: 23 February 2003 / Published online: 22 May 2003 RID="*" ID="*"Corresponding author. Fax: +1-734/9361-905, E-mail: mycek@umich.edu  相似文献   

5.
We describe a new fluorescence imaging device for clinical cancer photodetection in hollow organs in which the tumor/normal tissue contrast is derived from the fluorescence lifetime of endogenous or exogenous fluorochromes. This fluorescence lifetime contrast gives information about the physicochemical properties of the environment which are different between normal and certain diseased tissues. The excitation light from a CW laser is modulated in amplitude at a radio frequency by an electrooptical modulator and delivered by an optical fiber through an endoscope to the hollow organ. The image of the tissue collected by the endoscope is separated in two spectral windows, one being the backscattered excitation light and the other the fluorescence of the fluorochrome. Each image is then focused on the photocathode of image intensifiers (II) whose optical gain is modulated at the same frequency as the excitation intensity, resulting in homodyne phase-sensitive images. By acquiring stationary phase-sensitive frames at different phases between the excitation and the detection, it is possible to calculate in quasi-real time the apparent fluorescence lifetime of the corresponding tissue region for each pixel. A result obtained by investigating the endogenous fluorochromes present in the mucous membrane of an excised human bladder is presented to illustrate this method and most of the optical parameters which are of major importance for this photodetection modality have been evaluated.  相似文献   

6.
The biosciences require the development of methods that allow a non-invasive and rapid investigation of biological systems. In this aspect, high-end imaging techniques allow intravital microscopy in real-time, providing information on a molecular basis. Far-field fluorescence imaging techniques are some of the most adequate methods for such investigations. However, there are great differences between the common fluorescence imaging techniques, i.e., wide-field, confocal one-photon and two-photon microscopy, as far as their applicability in diverse bioscientific research areas is concerned. In the first part of this work, we briefly compare these techniques. Standard methods used in the biosciences, i.e., steady-state techniques based on the analysis of the total fluorescence signal originating from the sample, can successfully be employed in the study of cell, tissue and organ morphology as well as in monitoring the macroscopic tissue function. However, they are mostly inadequate for the quantitative investigation of the cellular function at the molecular level. The intrinsic disadvantages of steady-state techniques are countered by using time-resolved techniques. Among these fluorescence lifetime imaging (FLIM) is currently the most common. Different FLIM principles as well as applications of particular relevance for the biosciences, especially for fast intravital studies are discussed in this work.   相似文献   

7.
We report a wide-field fluorescence lifetime imaging (FLIM) system that uses a blue picosecond pulsed diode laser as the excitation source. This represents a significant miniaturization and simplification compared with other time-domain FLIM instruments that should accelerate the development of clinical and real-world applications of FLIM. We have demonstrated this instrument in two configurations: a macroimaging setup applied to multiwell plate assays of chemically and biologically interesting fluorophores and a microscope system that has been applied to imaging of tissue sections. The importance of the adjustable repetition rate of this laser source is discussed with respect to noise reduction and precision in the lifetime determination, illustrating a further significant advantage over conventional mode-locked solid-state lasers.  相似文献   

8.
多光子成像技术是一种层析能力好、信噪比高的新型光学成像技术。在皮肤光学三维检测中,多光子技术已经应用于无创在体成像,且已得到产业化开发。本文将首先介绍多光子皮肤检测系统的若干核心技术,即双光子自发荧光技术、二次谐波成像技术、荧光寿命成像技术、相干反斯托克斯-拉曼成像技术等,然后简要介绍多光子成像系统在皮肤疾病成像检测上的应用,最后分析该系统的优势和未来可能的发展趋势。  相似文献   

9.
利用一种基于时间相关单光子计数器的双光子激发荧光寿命显微成像技术,对猪眼底视网膜色素上皮层细胞内的脂褐素和氧化黑色素颗粒的空间分布及其荧光寿命特性进行了研究,尤其对于这些色素颗粒在光致氧化环境中的荧光寿命差异进行了分析.结果表明,利用荧光寿命测量能有效区分视网膜色素上皮层细胞中的多组分荧光团,利用荧光寿命的衰减参数可分辨正常及异常的荧光现象.该方法有望发展成为一种用于眼科临床诊断及病理学研究的高灵敏度的工具,对眼底细胞随年龄增长的衰老机理的研究具有重要的意义. 关键词: 双光子激发荧光 荧光寿命成像 视网膜色素上皮层  相似文献   

10.
利用一种基于时间相关单光子计数器的双光子激发荧光寿命显微成像技术,对猪眼底视网膜色素上皮层细胞内的脂褐素和氧化黑色素颗粒的空间分布及其荧光寿命特性进行了研究,尤其对于这些色素颗粒在光致氧化环境中的荧光寿命差异进行了分析.结果表明,利用荧光寿命测量能有效区分视网膜色素上皮层细胞中的多组分荧光团,利用荧光寿命的衰减参数可分辨正常及异常的荧光现象.该方法有望发展成为一种用于眼科临床诊断及病理学研究的高灵敏度的工具,对眼底细胞随年龄增长的衰老机理的研究具有重要的意义.  相似文献   

11.
We present a time-gated, optically sectioned, hyperspectral fluorescence lifetime imaging (FLIM) microscope incorporating a tunable supercontinuum excitation source extending into the UV. The system is capable of resolving the excitation spectrum, emission spectrum, and fluorescence decays in an optically sectioned image.  相似文献   

12.
With the increased development and use of fluorescence lifetime-based sensors, fiber optic sensors, fluorescence lifetime imaging microscopy (FLIM), and plate and array readers, , calibration standards are essential to ensure the proper function of these devices and accurate results. For many devices that utilize a “front face excitation” geometry where the excitation is nearly coaxial with the direction of emission, scattering-based lifetime standards are problematic and fluorescent lifetime standards are necessary. As more long wavelength (red and near-infrared) fluorophores are used to avoid background autofluorescence, the lack of lifetime standards in this wavelength range has only become more apparent . We describe an approach to developing lifetime standards in any wavelength range, based on Förster resonance energy transfer (FRET). These standards are bright, highly reproducible, have a broad decrease in observed lifetime, and an emission wavelength in the red to near infrared making them well suited for the laboratory and field applications as well. This basic approach can be extended to produce lifetime standards for other wavelength regimes.  相似文献   

13.
This article describes a method for reducing the acquisition time in three-dimensional (3D) continuous-wave electron paramagnetic resonance (CW-EPR) imaging. To visualize nitroxyl spin probes, which have a short lifetime in living organisms, the acquisition time for a data set of spectral projections should be shorter than the lifetime of the spin probes. To decrease the total time required for data acquisition, the duration of magnetic field scanning was reduced to 0.5 s. Moreover, the number of projections was decreased by using the concept of a uniform distribution. To demonstrate this faster data acquisition, two kinds of nitroxyl radicals with different decay rates were measured in mice. 3D EPR imaging of 4-hydroxy-2,2,6,6-tetramethylpiperidine-d17-1-15N-1-oxyl in mouse head was successfully carried out. 3D EPR imaging of nitroxyl spin probes with a half-life of a few minutes was achieved for the first time in live animals.  相似文献   

14.
鲍振川  潘永乐 《光学学报》1991,11(9):81-785
本文研究了钠分子高位三重态荧光寿命的测量方法。利用倍频晶体模拟等频双光子激发过程和对荧光衰变曲线求卷积的数值计算方法。有效地消除了测量仪器响应函数的影响,测量了Na_2高位三重态2~3∏_g→a~3∑_u~+的荧光寿命。  相似文献   

15.
《Current Applied Physics》2015,15(12):1634-1640
To study the mechanisms of and conditions for adipogenesis, an accurate in situ observation tool is necessary to monitor the quantity of intracellular neutral lipids in differentiating preadipocytes. Although conventional fluorescence intensity imaging is a powerful tool for observing the formation and growth of an individual lipid droplet, it suffers from photobleaching and ambiguous autofluorescence or background signals from cells. In this paper, we present a fluorescence lifetime imaging microscopy (FLIM) technique that has the potential to quantify the ratio of neutral to polar lipids in a cell. Measurement of time-lapse FLIM images of differentiating 3T3-L1 cells that contained the Nile Red (NR) probe showed that the average lifetime of NR decreased from 4 ns in preadipocytes to 3 ns in fully differentiated adipocytes after 10 days of differentiation. This large change in the lifetime of NR can be used to monitor the early stages of adipogenesis, even when the lipid droplet is too small to be identified with a conventional microscope.  相似文献   

16.
Near infrared (NIR) multi-photon excitation of the NIR-emitting lanthanides neodymium (Nd3+) and ytterbium (Yb3+) sensitized by a fluorescein-linked chelator was demonstrated. Because tissues display minimal absorbance near the excitation wavelength of 800 nm, and because the lanthanides display long decay times, these results suggest the use of Nd3+ and Yb3+ as luminescent probes in tissues with multi-photon excitation.  相似文献   

17.
Fluorescence lifetime imaging microscopy (FLIM) based on time-correlated single photon counting (TCSPC) is a widely used method for fluorescence resonance energy transfer (FRET). Here we report a feasible add-on approach to upgrade a commercial two-photon FLIM microscope into a single-photon FLIM microscope which provides optimal FLIM-FRET imaging of FRET pairs consisting of cyan fluorescent proteins (CFPs) as the donor and yellow fluorescent proteins (YFPs) as the acceptor. The capability of the upgraded system is evaluated and discussed, and the imaging performance of the system is demonstrated using FLIM-FRET experiments with a representative CFP-YFP FRET pair (mCerulean-mCitrine).  相似文献   

18.
Digitized video microscopy is rapidly finding uses in a number of fields of biological investigation because it allows quantitative assessment of physiological functions in intact cells under a variety of conditions. In this review paper, we focus on the rationale for the development and use of quantitative digitized video fluorescence microscopic techniques to monitor the molecular order and organization of lipids and phospholipids in the plasma membrane of single living cells. These include (1) fluorescence polarization imaging microscopy, used to measure plasma membrane lipid order, (2) fluorescence resonance energy transfer (FRET) imaging microscopy, used to detect and monitor phospholipid domain formation, and (3) fluorescence quenching imaging microscopy, used to spatially map fluid and rigid lipid domains. We review both the theoretical as well as practical use of these different techniques and their limits and potential for future developments, and provide as an illustrative example their application in studies of plasma membrane lipid order and topography during hypoxic injury in rat hepatocytes. Each of these methods provides complementary information; in the case of hypoxic injury, they all indicated that hypoxic injury leads to a spatially and temporally heterogeneous alteration in lipid order, topography, and fluidity of the plasma membrane. Hypoxic injury induces the formation of both fluid and rigid lipid domains; the formation of these domains is responsible for loss of the plasma membrane permeability barrier and the onset of irreversible injury (cell death). By defining the mechanisms which lead to alterations in lipid and phospholipid order and organization in the plasma membrane of hypoxic cells, potential sites of intervention to delay, prevent, or rescue cells from hypoxic injury have been identified. Finally, we briefly discuss fluorescence lifetime imaging microscopy (FLIM) and its potential application for studies monitoring local lipid and phospholipid molecular order and organization in cell membranes.  相似文献   

19.
The current advances of fluorescence microscopy and new fluorescent probes make fluorescence resonance energy transfer (FRET) a powerful technique for studying protein-protein interactions inside living cells. It is very hard to quantitatively analyze FRET efficiency using intensity-based FRET imaging microscopy due to the presence of autofluorescence and spectral crosstalks. In this study, we for the first time developed a novel photobleaching-based method to quantitatively detect FRET efficiency (Pb-FRET) by selectively photobleaching acceptor. The Pb-FRET method requires two fluorescence detection channels: a donor channel (CH 1 ) to selectively detect the fluorescence from donor, and a FRET channel (CH 2 ) which normally includes the fluorescence from both acceptor and donor due to emission spectral crosstalk. We used the Pb-FRET method to quantitatively measure the FRET efficiency of SCAT3, a caspase-3 indicator based on FRET, inside single living cells stably expressing SCAT3 during STS-induced apoptosis. At 0, 6 and 12 h after STS treatment, the FRET efficiency of SCAT3 obtained by Pb-FRET inside living cells was verified by two-photon excitation (TPE) fluorescence lifetime imaging microscopy (FLIM). The temporal resolution of Pb-FRET method is in second time-scale for ROI photobleaching, even in microsecond time-scale for spot photobleaching. Our results demonstrate that the Pb-FRET method is independent of photobleaching degree, and is very useful for quantitatively monitoring protein-protein interactions inside single living cell.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号