共查询到20条相似文献,搜索用时 0 毫秒
1.
Determination of polybrominated diphenyl ethers in soil by ultrasonic assisted extraction and gas chromatography mass spectrometry 总被引:4,自引:0,他引:4
An analytical method for the determination of polybrominated diphenyl ethers (PBDEs) in soil was developed. Soil samples were placed in small glass columns and PBDEs extracted from soil, with a low volume of ethyl acetate (5 mL, 2× 15 min), assisted by sonication. PBDEs were determined by gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC–MS–SIM) and residues were confirmed by their retention times, selected ions and qualifier–target abundance ratios. Recovery studies were performed at 10, 1, 0.1 and 0.05 μg/kg fortification levels, and the recoveries obtained ranged from 81 to 104% with a relative standard deviation between 1 and 9%. The detection limit of the method varied from 2 to 30 pg/g and the quantification limit ranged from 7 to 100 pg/g for the different PBDEs studied. The developed method was linear over the range assayed, 0.01–10 μg/kg with determination coefficients equal or higher than 0.997. The proposed method was used to determine PBDEs levels in soil samples from different areas of Spain and PBDEs were detected in some samples with values ranging from 1.3 to 5.6 μg/kg. 相似文献
2.
《Analytica chimica acta》2004,520(1-2):237-243
In the Czech Republic no study on the levels of brominated flame retardants in human milk has been conducted, yet. In the first step analytical method for determination of PBDEs in this bioindicator matrix was implemented. Liquid–liquid extraction (LLE) (hexane, diethyl ether), followed by gel permeation chromatography was employed for isolation of PBDEs. Identification and quantification of PBDEs was carried out by GC–MS operated in negative chemical ionisation (NCI). Two mass spectrometric technologies, one employing quadrupole and the other one high resolution (HR) time-of-flight (TOF) analyzer, etc. were used in our study. Detection limits (LODs) obtained by quadrupole analyzer ranged from 0.02 to 0.05 ng g−1 lipid weight, using high resolution time-of-flight analyzer LODs were significantly lower, ranging from 0.002–0.005 ng g−1 lipid weight, what enabled detection of minor PBDE congeners.
Within this pilot study 103 breast milk samples, obtained from mothers living in Olomouc region, were examined. Ten PBDE congeners were determined. All samples examined till now contained PBDEs residues, the dominating contaminant representing this group was congener BDE 47. In most of analysed samples levels of this compound ranged from 0.2 to 2 ng g−1 of lipid weight. Three exceptionally contaminated samples, containing levels of PBDEs 5–10 times higher than other samples, were found. 相似文献
3.
大流量采样高分辨气相色谱/高分辨质谱法测定大气中的多氯联苯和多溴联苯醚 总被引:1,自引:0,他引:1
建立了大流量空气采样高分辨气相色谱/高分辨质谱(HRGC/HRMS)同时分析测定大气样品中多氯联苯(PCBs)和多溴联苯醚(PBDEs)的分析方法。结果表明在采样过程中污染物没有发生穿透。通过添加 13C同位素标准物质进行评价,PCBs和PBDEs的加标回收率分别为60.7%~121.4%和69.9%~140.4%,均符合美国环保署相关方法的要求。PCBs和PBDEs的方法检出限分别低于0.019 pg/m3和0.189 pg/m3;色谱分离效果良好,可以满足大气样品中PCBs和PBDEs的监测需要。 相似文献
4.
建立了室内灰尘样品中8种常见多溴联苯醚(PBDEs: BDE-28、BDE-47、BDE-99、BDE-100、BDE-153、BDE-154、BDE-183和BDE-209)的气相色谱-负化学电离源质谱(GC-NCI/MS)分析方法。样品经吸尘器采集、正己烷超声萃取、浓缩后,采用GC-NCI/MS测定。结果表明,方法的加标回收率为53.2%~107.6%,日内测定的相对标准偏差(RSD)为2.8%~16.5%,日间测定的RSD为6.4%~22.6%。除了BDE-209的检出限(信噪比为3)为0.15 ng/g外,其他多溴联苯醚的检出限为0.003~0.015 ng/g。该方法灵敏度高,准确度和精密度好,简便快速,溶剂消耗量少,适用于灰尘中三溴~十溴联苯醚的测定。 相似文献
5.
An effective multi‐residue pretreatment technique, solid‐phase extraction (SPE) combined with dispersive liquid–liquid microextraction (DLLME), was proposed for the trace analysis of 14 polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in milk samples using gas chromatography–mass spectrometry (GC‐MS). Interesting analytes in milk samples were extracted with hexane after protein precipitation. The hexane extracts were loaded on an LC‐Florisil column to isolate analytes from the milk matrix. The elutes were dried and dissolved in acetone, which was used as the disperser solvent in subsequent DLLME procedures. The effects of several important parameters on the extraction efficiency were evaluated. Under the optimized conditions, a linear relationship was obtained in the range of 0.02–10.00 μg/L (PCBs) and 0.5–100.00 μg/L (PBDEs). The LOD (S/N=3) and relative standard deviations (RSDs, n=5) for all analytes were 0.01–0.4 μg/L and 0.6–8.5%, respectively. The recoveries of the standards added to raw bovine milk samples were 74.0–131.8%, and the repeatabilities of the analysis results were 1.12–17.41%. This method has been successfully applied to estimating PCBs and PBDEs in milk samples. 相似文献
6.
针对环境监测的特点和要求,建立了同位素稀释-高分辨气相色谱/高分辨质谱测定大气中多溴联苯醚(PBDEs)和多溴联苯153(BB153)的方法。采用正己烷/二氯甲烷(1:1, v/v)及正己烷分别对PBDEs和BB153进行快速溶剂萃取,并通过复合硅胶柱净化。在校准曲线最高浓度的10%和90%加标水平下得到的天然内标的平均回收率分别为100%和104%,平均相对标准偏差(n=7)分别为5%和6%;二至十溴代联苯醚和BB153相应的13C同位素标准物质回收率在36.5%~133%之间;而一溴代联苯醚13C同位素标准物质回收率较差,可能是由于物化性质与其他化合物不同。在实际采样体积为300 m3的情况下,未发生污染物穿透现象;分析物检出限低于2×10-4 ng/Nm3,提取内标回收率在56%~126%之间(一溴代联苯醚除外)。实验结果表明该方法能对化合物准确定量,适用于大气中二至十溴代联苯醚和BB153的分析。 相似文献
7.
气相色谱-负化学源质谱快速测定母乳中的多溴联苯醚 总被引:1,自引:0,他引:1
建立了母乳中8种多溴联苯醚(PBDEs:BDE28,BDE47,BDE99,BDE100,BDE153,BDE154,BDE183,BDE209)的气相色谱-负化学源质谱测定方法(GC-NCI/MS)。样品经索氏提取、酸化硅胶除脂、硅胶氧化铝色谱柱净化后,在7 m长的毛细管气相色谱柱上快速分离,NCI/MS以选择离子监测模式测定目标化合物。其中,三溴~七溴联苯醚采用内标法定量,十溴联苯醚(BDE209)采用同位素稀释法定量。8种PBDEs的检出限为1.74~6.35 pg/g(以脂肪计)。加标回收试验的回收率为61.5%~108%,相对标准偏差为2.06%~10.1%(n=6)。并采用母乳参考物质进一步证实了该方法的准确可靠。该方法提高了BDE209的分析灵敏度,而且分析成本相对较低,分析时间短,适于推广。 相似文献
8.
Time-of-flight (TOF) instruments have recently gained popularity in quantitative analyses. Normally, TOF mass spectrometers are used for accurate mass measurements for empirical formula verification. However, over the past decade, they have been used quantitatively as well. Because of the fast separations and narrow peaks that result from gas chromatography separations, scanning mass spectrometers are not ideal detectors. TOF mass spectrometers, however, have the ability to collect spectra at a faster rate. Two-dimensional gas chromatography has also been introduced to further resolve peaks from complex matrices. Two-dimensional gas chromatography results in a faster separation as well as narrower peaks. This paper reviews the methods currently in the literature for the quantitation of compounds using one- and two-dimensional gas chromatography and TOF mass spectrometry detection. 相似文献
9.
A one-step extraction and clean-up method using pressurized liquid extraction (PLE) (selective PLE) combined with gas chromatography-ion-trap tandem mass spectrometry (GC-ITMS-MS) was evaluated for the analysis of polybrominated diphenyl ethers (from tri- to hepta-PBDEs) at low concentrations in fish and shellfish samples. To this end, the performance of an on-line PLE extraction/clean-up method and of a classical Soxhlet extraction and clean-up method using a multi-layer modified silica column were compared. The two sample treatment methods provided similar results, although an important reduction in the sample treatment time (40 min per sample) was achieved using the selective PLE method. In addition, the suitability of the PLE combined with GC-ITMS-MS method was evaluated by comparing the results obtained in the analysis of fish samples with those obtained by gas chromatography-high resolution mass spectrometry (GC-HRMS). Good agreement between both techniques was obtained with differences between the mean values of less than 16%. The selective PLE method coupled to GC-ITMS-MS produced accurate results for PBDE determination with low limits of detection (1.0-16.8 pg g−1 wet weight) and quantification (3.1-51 pg g−1 wet weight) as well as good precision (RSD < 16%). This method has been applied to the analysis of PBDEs in fish and shellfish samples collected at fish markets in Catalonia (NE Spain). 相似文献
10.
建立了气相色谱-四极杆高分辨飞行时间串联质谱分析复杂芳烃体系样品中苯甲醛、苯甲醇、苯乙酮与苯乙醛的方法。该方法通过使用高分辨质谱得到目标化合物特征离子的精确质量数,结合色谱保留时间,有效排除了复杂芳烃体系样品本底中碎片离子的干扰,提高了定性与定量分析的准确性。使用目标化合物特征离子的质谱峰面积作为定量计算依据。苯甲醛、苯甲醇、苯乙酮与苯乙醛在各自的质量浓度范围内呈现良好的线性响应,回收率为87.97%~103.01%,定量限分别为0.04、0.10、0.08与0.03 mg/L,检出限分别为0.01、0.03、0.02与0.01 mg/L。对3份实际样品中的苯甲醛、苯甲醇、苯乙酮与苯乙醛进行了定量分析。本研究为气相色谱-四极杆高分辨飞行时间质谱技术应用于复杂体系中的微量杂质分析提供了一种新的思路和手段。通过精确的质量分辨和测定可以降低对色谱分离的依赖,弥补传统气相色谱-四极杆低分辨质谱技术的不足。 相似文献
11.
This paper gives an overview of the potentials of liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QqTOF) in the environmental analysis. Examples of applications of QqTOF instruments for target analysis of pharmaceuticals and pesticides are presented and discussed, as well as applications aimed on the identification of unknown compounds present in environmental waters or on the elucidation of structures of biodegradation and photodegradation products. Specific issues such as uncertainty of mass measurement and quantitative performances are discussed in details. 相似文献
12.
采用OasisHLB固相萃取柱萃取血清中的多溴联苯醚(PBDEs),经浓硫酸柱上除脂后,利用气相色谱-负化学源质谱法测定BDE-17、28、47、66、99、100、153、154、183和209共10种PBDEs组分。BDE-209的测定采用DB-5 ms色谱柱(15 m×0.25 mm×0.1 μm),其他组分采用VF-5 ms色谱柱(30 m×0.25 mm×0.25 μm)。对样品中蛋白质的去除溶剂和固相萃取条件(如洗脱溶剂及其用量)进行了优化。胎牛血清中的加标回收试验结果显示,各PBDEs单体相对于内标的平均回收率为78.5%~109.7%,日内测定的相对标准偏差(RSD)为0.3%~7.4%,日间测定的RSD为1.4%~14.1%。胎牛血清中三溴~七溴联苯醚的检出限(信噪比为3)为0.10~0.27 ng/L;定量限(信噪比为10)除了BDE-209为7.91 ng/L外,其他PBDEs为0.35~0.91 ng/L。采用本方法测定标准参考物质SRM1957和SRM1958,结果在参考值范围内。实验结果表明,本方法灵敏度高、准确度和精密度好,简便快速,溶剂消耗量少,适用于人体血清中三至十位溴取代联苯醚的测定。 相似文献
13.
We report here an efficient and comprehensive analytical methodology based on gas chromatography with high resolution mass spectrometry (GC–HRMS) to simultaneously determine PBDEs from mono to deca brominated and hydroxy (OH-) and methoxy (MeO-) PBDE metabolites in environmental samples, particularly, sediment, fish tissue and milk. Among a number of extraction and clean-up methods tested, pressurized liquid extraction followed by gel permeation chromatography and florisil clean-up proved to be simple, robust and optimized so that all target analytes (parent compounds and metabolites) were collected in a single fraction. Extracts were analyzed by GC–HRMS to identify PBDEs. Following, the same extracts were derivatized and re-analyzed by GC–HRMS to determine 11 target and 35 non-target OH- and MeO-PBDEs. Monitoring of the M+ for MeO-PBDEs and the [M−CH2CO]+ ions for derivatized OH-PBDEs at 10,000 resolution permitted unequivocal identification of the PBDE metabolites in the environmental matrices examined. The method was validated in terms of accuracy, precision, detection limits and long-term stability. The analytical precision obtained with this method was between 0.3 and 17%, and the limits of quantification were lower than 3.28 pg/g dry weight, 20.5 and 41.4 pg/g lipid weight in sediment, milk and fish, respectively. The method was applied to determine PBDEs and target and non-target metabolites in all three matrices. 相似文献
14.
The analysis by gas chromatography coupled with mass spectrometry (GC/MS) of 40 different congeners of polybrominated diphenyl ethers (PBDEs) containing 1-7 bromine atoms is described. Two different MS approaches were used, negative chemical ionization (NCI-MS) and electron ionization (EI-MS). Operating parameters such as electron energy and source temperature were optimized in order to obtain the maximum sensitivity in the EI-MS study. For NCI-MS analyses, the effects of the moderating gas (methane or ammonia), source temperature and system pressure were studied. The quality parameters of the two approaches tested were compared. NCI-MS gave detection limits between 30 fg and 1.72 pg, whereas EI-MS gave detection limits between 0.53 and 32.09 pg. The main advantage of EI-MS is that it provides better structural information. Moreover, the use of EI-MS allowed the use of an isotope dilution method for quantification, making the analysis more reliable at trace levels. 相似文献
15.
In-source collision-induced dissociation (CID) fragmentation features of multiclass flavonoid glycoconjugates were examined using liquid chromatography electrospray time-of-flight mass spectrometry. Systematic experiments were performed to search for optimal conditions for in-source fragmentation in both positive and negative ion modes. The objective of the study was to attain uniformly appropriate conditions for a wide range of analytes independently of the aglycone, the attached sugar part and the type of bond between the aglycone and the glycan moieties (O- or C-glycosides). Studied substances included representatives of flavonols, flavones, flavanones and anthocyanins and, regarding their glycan parts, mono-, di- and triglycosides with varying distribution of carbohydrate moieties (di-O-glycosides, O-diglycosides, O,C-diglycosides). The breakdown properties of the analytes along with the abundances of the characteristic diagnostic ions required for structural elucidation of complex flavonoid derivatives were evaluated. An optimized value was found for the instrument parameter (fragmentor voltage) affecting the in-source CID fragmentation of the analytes [230 V (ESI+) and 330 V (ESI-)]. Thus, appropriate performance in terms of both highly sensitive full-scan acquisition and fragmentation information was obtained for all the investigated flavonoids. In addition, singularities in the abundance of selected diagnostic ions (e.g. Y(0), Y(1) and Y*) due to variations in the interglycosidic linkage (rutinoside-neohesperidoside) in the glycan part were found and are also evaluated and discussed in detail. The combination of in-source CID fragmentation with high mass accuracy MS detection establishes a working basis for the development of versatile and useful LC-MS methods for wide-scope screening, non-targeted detection and tentative identification of flavonoid derivatives. 相似文献
16.
A column chromatography procedure was developed for the clean-up of solvent-extracted sediment samples for the fractionation of polybrominated diphenyl ethers (PBDEs) and polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs). The procedure included multiple column chromatography steps for clean-up for the separation of PBDEs from PBDD/Fs. The separation of the two chemical groups overcame the mutual interfering problem during the GC-ion trap MS analysis. The method was validated with the analysis of quality control samples. The method accuracy represented with relative error was less than 16% for all targeted PBDEs and PBDD/Fs congeners. Recoveries of the 13C-labeled standards ranged from 64% to 117% with relative standard deviation from 7.3% to 15%. Results from the analysis of environmental sediment samples collected in the vicinity of a recycling site for electronic wastes showed high levels of PBDEs (1.5-12 ng/g, dry weight), trace levels of PBDFs (0.025-0.92 ng/g, dry weight) and non-detectable PBDDs. 相似文献
17.
Mas S Jáuregui O Rubio F de Juan A Tauler R Lacorte S 《Journal of mass spectrometry : JMS》2007,42(7):890-899
We propose an instrumental method based on liquid chromatography coupled to negative ion-spray ionization (ISP(-)) tandem mass spectrometry (MS/MS), for the simultaneous analysis of eight hydroxylated brominated diphenyl ethers (OH-PBDEs) in four different environmental matrices (soil, fish, sludge and particulate matter). The reversed-phase chromatographic separation was performed on a 50 mm Xbridge C18 column, and the compounds were well resolved with a gradient consisting of a ternary mixture of 5 mMammonium acetate, methanol and acetonitrile. Detection was performed in the multiple reaction monitoring (MRM) mode using the [M - H](-) ion as base peak. The fragmentation pathways of the OH-PBDEs varied according to the hydroxyl substitution in the benzene rings and produced characteristic MRM transitions needed for resolving isomeric compounds. The method is acceptable for quantification in the high picogram per gram dry weight (dw) level for all matrices analyzed. Repeatability and reproducibility tested at 75 pg microl(-1) were below 10% using internal standard quantification. The ISP (-) enhancement due to matrix effects was in the 76-132% range and the highest values corresponded to sludge samples. The use of the proposed method based on LC-ISP(-)-MS/MS opens a new way to directly determine OH-PBDEs without the need of derivatization. 相似文献
18.
Identifying unknown proteins has become a central focal point for proteomic and biopharmaceutical development laboratories. Our laboratory investigated using quadrupole time-of-flight mass spectrometry (Qq/TOFMS) for the analysis of intact proteins for the purpose of identifying unknowns while limiting the number of sample-handling steps between protein extraction and identification. Eight standard proteins, both unmodified and disulfide-bonded and ranging in mass from 5 to 66 kDa, were analyzed using nanoelectrospray and collision-induced dissociation to generate peptide sequence tags. An MS analysis, followed by MS/MS analyses on two to five individual protein charge states, were obtained to make an identification. Peptide sequence tags were extracted from the MS/MS data and used, in conjunction with molecular mass and source origin, to obtain protein identifications using the web-based search engine ProteinInfo (www.proteometrics.com). All of the proteins were unambiguously identified from the input data, after which, all of the major product ions were identified for structural information. In most cases, N- and/or C-terminal ions, and also stretches of consecutive product ions from the protein interior, were observed. This method was applied to the analysis and identification of an unknown detected via reversed-phase high-performance liquid chromatography. 相似文献
19.
Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) time-of-flight mass spectrometry (TOFMS) play an essential role in the analysis of biological molecules, not only peptides and proteins, but also DNA and RNA. Tandem mass spectrometry used for sequence analysis has been a major focus of technological developments in mass spectrometry, but accurate mass measurements by high-resolution TOFMS are equally important. This paper describes the role that high mass measurement accuracy can play in DNA composition assignment and discusses the influence of several parameters on mass measurement accuracy in both MALDI and ESI mass spectra. Five oligonucleotides (5-13mers) were used to test the resolving power and mass measurement accuracy obtained with MALDI and ESI instruments with reflectron TOF mass analyzers. The results from the experimental studies and additional theoretical calculations provide a basis to predict the practical utility of high-resolution TOFMS for the analysis of larger oligonucleotides. 相似文献
20.
Adriaensen L Vangaever F Lenaerts J Gijbels R 《Journal of mass spectrometry : JMS》2005,40(5):615-627
A series of cationic, zwitterionic and anionic fluorinated carbocyanine dyes, spin-coated on Si substrates, were measured with time-of-flight static secondary ion mass spectrometry (TOF-S-SIMS) under Ga(+) primary ion bombardment. Detailed fragmentation patterns were developed for all dyes measured. In the positive mode, the resulting spectra showed very intense signals for the precursor ions of the cationic dyes, whereas the protonated signals of the anionic dyes were hardly detected. Differences of three orders of magnitude were repeatedly observed for the secondary ion signal intensities of cationic and anionic dyes, respectively. All measured dyes yielded mass spectra containing several characteristic fragment ions. Although the secondary ion yields were still higher for the cationic than the anionic dye fragments, the difference was reduced to a factor of < or =10. This result and the fact that M(+), [M + H](+) or [M + 2H](+) are even-electron species make it very likely that the recorded fragments were not formed directly out of the (protonated) parent ions M(+), [M + H](+) or [M + 2H](+). In the negative mode, none of the recorded spectra contained molecular information. Only signals originating from some characteristic elements of the molecules (F, Cl), the anionic counter ion signal and some low-mass organic ions were detected. A comparative study was made between TOF-S-SIMS, using Ga(+) primary ions, and other mass spectrometric techniques, namely fast atom bombardment (FAB), electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI). The measurements showed that MALDI, ESI and FAB all give rise to spectra containing molecular ion signals. ESI and FAB produced M(+) and [M + H](+) signals, originating from the cationic and zwitterionic dyes, in the positive mode and M(-) and [M - H](-) signals of the anionic and zwitterionic dyes in the negative mode. With MALDI, molecular ion signals were measured in both modes for all the dyes. Structural fragment ions were detected for FAB, ESI and MALDI in both the positive and negative modes. Compared with the other techniques, TOF-S-SIMS induced a higher degree of fragmentation. 相似文献