首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatographic (HPLC) method for quantifying unsaturated hexasaccharide and tetrasaccharide from Streptomyces hyaluronidase enzyme digestion products of hyaluronic acid was developed using a gel-permeation column packed with a sulphated polystyrene-divinylbenzene gel. For the oligosaccharides, the separation was accomplished in less than 7 min with a detection limit of 65 ng. An unsaturated non-sulphated disaccharide prepared from hyaluronic acid (delta Di-HA) and an unsaturated sulphated disaccharide (delta Di-4S) were analyzed by a HPLC method using a combination of two different gel-permeation columns. The separation of the disaccharides required less than 17 min at a flow rate of 0.7 ml/min with detection limits of as little as 4 ng for delta Di-HA and 5 ng for delta Di-4S. Both chromatographic methods were used for assay of a major component of hyaluronic acid and trace amounts of chondroitin sulphates in rabbit synovial fluid. The resulting contents of hyaluronic acid were compared to the values of polymeric hyaluronic acid directly measured by a HPLC method using two gel-permeation columns packed with a poly(hydroxyalkyl methacrylate) gel and the amounts of hyaluronic acid converted from uronic acid content determined by a colorimetric method.  相似文献   

2.
Abstract

A specific and sensitive HPLC method has been developed for the assay of meclizine dihydrochloride in dog serum using an internal standard technique with a single step extraction. The extracts are injected into a reversed phase ion pair HPLC system using a solvent containing camphorsulfonate as paring anion. The detection limit is 5 ng/ml and the range of linearity is 5–250 ng/ml. The method has been used to quantitate meclizine dihydrochloride levels in bioavailability and pharmacokinetic studies in dogs.  相似文献   

3.
A sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of tibenelast, 5,6-diethoxybenzo[b]thiophene-2- carboxylic acid, in plasma and urine. The plasma assay involves protein precipitation with 4% trichloroacetic acid, while the urine assay is an automated solid-phase extraction procedure that utilizes the Waters Millilab workstation. The analysis was achieved by reversed-phase HPLC with ultraviolet detection at 313 nm. The quantitation limit of the assay was 50 ng/ml in plasma and 100 ng/ml in urine. The intra-day coefficient of variation for the plasma analysis was between 2.2 and 8.4%, while the overall inter-day coefficient of variation was 5.5 and 6.0% for the high and low calibration curves, respectively. The intra-day coefficient of variation for the urine analysis was between 0.3 and 3.0%, while the inter-day coefficient of variation was 2.1% for both the low and high validation samples. The assay methodology has been used in the evaluation of samples from pharmacokinetic and clinical safety studies.  相似文献   

4.
《Journal of chromatography. A》1993,630(1-2):415-417
A rapid and simple HPLC method for the determination of Lovastatin (mevinolin) and mevinolinic acid in fermentation fluids of Aspergillus terreus using a Separon SGX C18 column and methanol-18 mM orthophosphoric acid (77.5:22.5, v/v) as mobile phase with detection at 238 nm is described. The detection limit of Lovastatin and mevinolinic acid was 20–30 ng/ml.  相似文献   

5.
A single high-performance liquid chromatographic (HPLC) assay for the quantitative determination of dilevalol, the R,R isomer of labetalol, was developed for both plasma and urine. A significantly improved limit of detection for dilevalol in plasma was accomplished by extensive modification of an HPLC assay originally developed in our laboratory for labetalol. This simplified method is readily adaptable to urine and represents the first reported HPLC assay for the quantitative determination of dilevalol in this biofluid. Drug was recovered from plasma or urine by partition into diethyl ether under mildly alkaline conditions and back-extraction into dilute acid. Reversed-phase separation of dilevalol and the internal standard was accomplished on a 150 X 4.1 mm column commercially packed with a spherical (5 micron) macroporous copolymer (PRP-1). No interferences were observed in extracts obtained from drug-free plasma or urine. Selectivity for dilevalol in the presence of other beta-blockers was established. This method demonstrated a linear detector response to concentrations of unchanged drug typically observed in urine and plasma following once-a-day treatment with dilevalol hydrochloride (100-800 mg). The lowest limit of reliable quantitation was established at 1 ng/ml in plasma. The intra-assay precision (coefficient of variation) remained less than 6% at all concentrations evaluated from 1 to 800 ng/ml. In urine, the lowest limit of quantitation was validated to 20 ng/ml where the intra-assay precision (coefficient of variation) for unchanged drug was less than 4% at all concentrations evaluated up to 400 ng/ml. This method is suitable for routine quantitation of unchanged drug in human plasma and urine following the administration of therapeutically effective doses of dilevalol hydrochloride.  相似文献   

6.
《Analytical letters》2012,45(10):805-816
Abstract

A sensitive and specific high performance liquid chromatographic (HPLC) assay for the determination of saccharin in plasma and urine was developed. Saccharin is extracted into diethyl ether at acid pH, evaporated, and reconstituted prior to instrumental analysis. Overall recovery of saccharin is 86.9 + 8.6% and the sensitivity limits of detection is 0.15 μg per ml of plasma or urine using a fluorescence detector. The sensitivity limit in plasma can be extended to 20 ng per ml by use of a 2 ml assay volume and detector attenuation. The assay was used for the determination of saccharin in plasma and urine of rats following oral doses of 5 mg/kg.  相似文献   

7.
A rapid, sensitive, and specific high performance liquid chromatographic (HPLC) assay was developed for the determination of 2-methoxy-11-oxo-11H-pyrido-[2,1-b]quinazoline-8-carboxylic acid (I) from biological fluids. The overall recovery from blood and plasma is 69 +/- 10% (S.D.) and 84 +/- 6% (S.D.), respectively, and the sensitivity limit of quantitation is 100 ng/ml by UV absorption and 5 ng/ml by fluorescence detection using a 1 ml specimen. The assay was used in the determination of blood levels of compound in the Rhesus monkey following intravenous administration of a 10 mg/kg dose, and of blood and urine levels of compound I in a dog following intravenous and oral administration of a 1 mg/kg dose.  相似文献   

8.
A method is described for the extraction of a phosphonic acid angiotensin-converting enzyme inhibitor from either urine or plasma, and subsequent quantitation using high-performance liquid chromatographic (HPLC) analysis and post-column o-phthalaldehyde reagent derivatization. The compound cannot be quantitatively extracted from the body fluids, but use of a fluorinated internal standard allowed for the computation of accurate results. With the use of an internal standard, excellent precision, linearity, and recovery were obtained for analyte response in both urine and plasma. In urine a working range of 0.2-10 micrograms/ml was found, with a limit of detection of 0.1 micrograms/ml. For plasma the working range was found to be 2-500 ng/ml, and the limit of detection was established as 1 ng/ml. Due to the non-polar character of the analyte at low pH values, it was possible to use novel extraction (solid-phase C8 column) and HPLC [poly(styrenedivinyl benzene) HPLC column] conditions to separate and quantitate the compound from plasma and urine.  相似文献   

9.
《Analytical letters》2012,45(11-12):1297-1310
Abstract

A simple, sensitive HPLC assay using flurescence detection was developed for quantitation of verapamil and its active metabolite, norverapamil in 100-200 μl blood samples from the rat. Baseline separation of verapamil, normverapamil and internal standard, propranolol, was attained within 14 minutes. Standard curves for verapamil and norverapamil were linear from 7 ng/ml to 1000 ng/ml with limit of detection of 4 ng/ml for both Compounds. the intraday and interday coefficients of variation in verapamil and norverapamil concentrations, determined from spiked whole blood samples, were less than 10%.  相似文献   

10.
A sensitive high-performance liquid chromatographic (HPLC) assay using fluorescence detection for quantifying lidocaine levels in plasma (in the ng/ml range) was developed. This novel HPLC assay has made possible the simultaneous monitoring of lidocaine levels in coronary and peripheral plasma obtained after myocardial controlled-release matrix administration (0.92 mg/kg during 4 h) in the arrhythmic dog. The method employed extracts the drug from plasma using 1-chlorobutane and a subsequent derivatization with 9-fluorenylmethylchloroformate in acetonitrile at 110 degrees C. The derivative was chromatographed on a C18 reversed-phase column and measured with fluorescence detection (excitation 254 nm, emission 313 nm). N-Methylephedrine was found to be suitable as an internal standard, post-derivatization. The derivatization product of lidocaine was identified and characterized by mass spectral analysis. It was found to have a unique and reproducible dicarbamate structure, which was stable for at least three days at room temperature. The method was tested with human plasma as well as on dog plasma. Analytical recoveries were 88.6 +/- 3.6 and 77.4 +/- 3.0% (mean +/- S.E.), respectively, at levels ranging from 25 to 200 ng/ml. The lower detection limit was 1 ng/ml lidocaine. In conclusion, this rapid and convenient analysis was found to be suitable for the bioavailability pharmacokinetic assessment of lidocaine following low-dose regional drug administration.  相似文献   

11.
Abstract

A reversed phase HPLC assay is described for the quantitation of allopurinol and oxipurinol in human plasma. The strategies for the development of this method are discussed. The analysis is performed on a C-18 column using an acidic aqueous mobile phase. Sample preparation consists of protein precipitation with a mixture of trichloracetic acid and perchloric acid. The detection limit of the assay for both substances is in the region of 30ng/ml. This method has been applied to an investigation of the relative bioavailability of two commercial preparations of 300mg allopurinol tablets in eight healthy volunteers.  相似文献   

12.
Simple and reproducible high-performance liquid chromatographic (HPLC) and gas chromatographic-mass spectrometric (GC-MS) methods have been developed for the simultaneous analysis of several acidic drugs in horse plasma and urine. Although the capillary GC-MS column provided better separation of the drugs than the reversed-phase C8 (3 microns, 75 mm) HPLC column, the total analysis time with HPLC was shorter than the total analysis time with GC-MS. The HPLC system equipped with a diode-array detector provided simultaneous screening (limit of detection 100-500 ng/ml) and confirmation (limit 1.0 micrograms/ml) of the drugs. The HPLC system equipped with fixed-wavelength ultraviolet and fluorescence detectors provided a relatively sensitive screening [limit of detection 50-150 ng/ml for ultraviolet and 10 ng/ml for fluorescence (naproxen only) detectors] of the drugs. However, the positive samples had to be confirmed by using either the diode-array detector or the GC-MS system. The GC-MS system provided simultaneous screening and confirmation of the drugs at very low concentrations (20-50 ng/ml).  相似文献   

13.
A sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the quantitation of mitoxantrone in plasma using electrochemical detection. Bisantrene was chosen as the internal standard. A reversed-phase, 10-microns muBondapak C18 analytical column (30 cm X 3.9 mm) with an isocratic mobile phase of 28% acetonitrile in 80 mM sodium formate buffer (pH 3.0) was used. The eluent was monitored by both electrochemical detection at an applied potential of +0.75 V vs. Ag/AgCl and visible absorbance at 660 nm. Only electrochemical detection was able to quantitate the internal standard and provided ten times higher sensitivity than visible absorbance for mitoxantrone with a detection limit as low as 0.1 ng/ml. Calibration curves in the range 0.1-1000 ng/ml showed good linearity (r = 0.998) and precision (coefficient of variation less than 10%). This HPLC method utilized a reproducible and inexpensive liquid-liquid extraction procedure. Using methylene chloride, the extraction efficacy of mitoxantrone from plasma was 85.3% with a coefficient of variation less than 2.1%. This new assay was then applied to measure mitoxantrone concentrations in plasma obtained from two leukemic patients receiving 12 mg/m2 mitoxantrone as a 1-h infusion.  相似文献   

14.
Abstract

A sensitive and rapid assay has been developed for the determination of LY217332, a 3'-imidazolo[4,5-c]pyridinium cephalosporin, in plasma. The method utilizes cyano solid phase column extraction and HPLC with ultraviolet detection. The lower limit of detection is 5 ng/ml plasma and the relative standard deviation for precision and accuracy was 5% or less from 50–500 ng/ml. The method is applicable to the assay of ceftazidime, cephaloridine, cefpirome and BMY-28142 with minor modification of the mobile phase and the detection wavelength.  相似文献   

15.
A high-performance liquid chromatographic (HPLC) method with electrochemical detection for the determination of oxilofrine [1-(4-hydroxyphenyl)-2-methylaminopropanol] in human plasma and urine (before and after cleavage of the metabolic conjugates) is described. Isolation from biological fluids is performed batchwise by weak acid cation exchange. Separation of plasma and urine components is achieved on a reversed-phase C18 column as an ion pair with heptanesulphonic acid. For amperometric detection the potential of the electrode was set at 0.95 V versus an Ag/AgCl reference electrode. The detection limit for oxilofrine in plasma is 1 ng/ml and in urine 12.5 ng/ml at a signal-to-noise ratio of 2.0 using 1.0 ml of plasma and 0.02 ml of urine. The method was compared with a gas chromatographic-mass spectrometric method and showed a good concordance for plasma (r = 0.996) and urine (r = 0.994). With the HPLC method it is also possible to determine related sympathomimetic drugs, e.g., etilefrine, norefenefrine or octopamine, after a slight modification of the mobile phase.  相似文献   

16.
A high-performance liquid chromatographic (HPLC) procedure has been developed for the quantification of Melanotan-II (MT-II), a cyclic heptapeptide which promotes rapid tanning of the skin, in rat plasma. The method involves precipitation of plasma proteins followed by direct-injection HPLC with ultraviolet detection. Calibration curves were linear over the range 100-1000 ng/ml for rat plasma. The method is reproducible and reliable with a detection limit of 50 ng/ml in plasma. Within- and between-day precision and accuracy reported as coefficient of variation and relative error, respectively, were < 7%. The application of the assay was successfully demonstrated by quantifying the concentration of MT-II in rat plasma samples following an intravenous dose of 0.3 mg/kg.  相似文献   

17.
An improved method for the determination of 4-amino-1-hydroxybutane-1,1-bisphosphonic acid (alendronate) in human urine and an assay in human plasma are described. The methods are based on co-precipitation of the bisphosphonate with calcium phosphates, automated pre-column derivatization of the primary amino group of the bisphosphonic acid with 2,3-naphthalene dicarboxyaldehyde (NDA)-N-acetyl-D-penicillamine (NAP) or cyanide (CN-) reagents, and high-performance liquid chromatography (HPLC) with electrochemical (ED) or fluorescence detection (FD). The feasibility of ED of the NDA-CN- derivative of aldendronate has been demonstrated, and a HPLC-ED assay in human urine has been validated in the concentration range 2.5-50.0 ng/ml. In order to eliminate the cyanide ion from the assay procedure, several other nucleophiles in the NDA derivatization reaction were evaluated. An NDA-NAP reagent was found to produce highly fluorescent derivatives of alendronate. The assay in urine based on NDA-NAP derivatization and HPLC-FD has been developed and fully validated in the concentration range 1-25 ng/ml. Based on the same NDA-NAP derivatization, an assay in human plasma with a limit of quantification of 5 ng/ml has also been developed. Both HPLC-FD assays were utilized to support various human pharmacokinetic studies with alendronate.  相似文献   

18.
A rapid high-performance liquid chromatographic (HPLC) method for the simultaneous determination of cortisol and cortisone in a single extract of 1 ml of serum is described. The method employs meprednisone as the internal standard. The steroids were analysed isocratically by reversed-phase HPLC with an octadecylsilane-bonded (ODS) column using ultraviolet detection. The matrix effect was reduced by lowering the sample pH by adding glacial acetic acid to the sera. The samples were then filtered through regenerated cellulose membranes at 4 degrees C and extracted with diethyl ether. The dried eluates were redissolved in the mobile phase and injected into the column. The detection limit of the assay for both steroids was 500 ng/l. Cortisol was determined in twenty serum samples by both HPLC and radioimmunoassay (RIA). The results were similar. Interference by other steroids and certain steroid analogue drugs was also studied. The HPLC method yielded no cross-reactivity between the different steroids as may occur with the RIA technique. The HPLC method was technically easy to perform and it allowed us to quantify both cortisol and cortisone in a single serum extract with high specificity.  相似文献   

19.
A sensitive, rapid and selective high-performance liquid chromatographic (HPLC) method has been developed to measure plasma levels of pyrimethamine in human subjects dosed with the antimalarials Fansidar or Fansidar and mefloquine. The drug was extracted from plasma at basic pH with n-butyl chloride-dichloromethane (96:4, v/v) and quantified on a normal-phase HPLC column with fluorescence detection (excitation 290 nm, emission 345 nm). Pyrimethamine was almost quantitatively extracted from plasma in the concentration range 20-200 ng/ml. The sensitivity limit was about 10 ng/ml of plasma, using a 0.5-ml specimen. The method was shown to be specific with respect to the other two components in the antimalarial combinations, namely sulfadoxine and mefloquine, and their metabolites. The assay was applied to pharmacokinetic studies of pyrimethamine in man following the oral administration of Fansidar of Fansidar and mefloquine.  相似文献   

20.
The chromatographic behaviour of ofloxacin on various sorbents, including ODS, C8, C1, nitril, phenyl and tert,-butyl, as stationary phases was investigated and a high-performance liquid chromatography (HPLC) assay was developed for the determination of ofloxacin in serum. The serum samples were directly introduced onto an HPLC column after filtering through a Morcut II membrane filter to remove proteins. The filtrate was concentrated on a pre-column using a phenyl stationary phase and was then introduced to an analytical column with an ODS stationary phase by column switching. Ofloxacin and enoxacin as an internal standard were detected by ultraviolet absorbance at 300 nm. Determination was possible for ofloxacin over the concentration range 50-2000 ng/ml; the limit of detection was 20 ng/ml. The recovery of ofloxacin added to serum was 88.8-101.7% with a coefficient of variation of less than 5.2%. This method is applicable to pharmacokinetic studies of patients after treatment with ofloxacin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号