首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Amphetamine and analogous compounds have been labeled with 4-fluoro-7-nitrobenzofurazane and analyzed on a microfabricated chip. Separation of norephedrine, ephedrine, cathinone, pseudoephedrine, methcathinone, amphetamine and methamphetamine is demonstrated using micellar electrokinetic capillary chromatography (MEKC) and laser-induced fluorescence (LIF) detection. Chiral separations of individual drugs were studied using neutral and negatively charged cyclodextrins (CDs) with and without the addition of an organic modifier and/or sodium dodecyl sulfate (SDS). The best results were obtained using a highly sulfated gamma-CD (HS-gamm-CD) in combination with a low concentration of SDS. To obtain complete separation of a mixture of (+/-)-norephedrine, (+/-)ephedrine, (+/-)-pseudoephedrine, (+/-)-methcathinone, (+/-)-amphetamine and (+/-)-methamphetamine it was necessary to add a small amount (1.5 mM) of SDS to the separation buffer. Optimized chiral separation was achieved within 7 min using an S-folded separation channel, a separation voltage of 8 kV and a buffer consisting of 50 mM phosphate (pH 7.35), 10 mM HS-gamma-CD and 1.5 mM SDS.  相似文献   

2.
Hou J  Zheng J  Rizvi SA  Shamsi SA 《Electrophoresis》2007,28(9):1352-1363
In this work, simultaneous separation of eight stereoisomers of ephedrine and related compounds ((+/-)-ephedrine, (+/-)-pseudoephedrine, (+/-)-norephedrine and (+/-)-N-methylephedrine) was accomplished using a polymeric chiral surfactant, i.e. polysodium N-undecenoxycarbonyl-L-leucinate (poly-L-SUCL) by chiral (C)MEKC-ESI-MS. The conditions of CMEKC were first investigated. The baseline separation of all eight stereoisomers of ephedrine and related compounds was achieved under optimum CMEKC conditions (35 mM poly-L-SUCL, 15 mM NH(4)OAc, pH 6.0, 30% v/v ACN, 30 kV and 20 degrees C) in less than 30 min. Next, a central composite design for response surface modeling has been described to evaluate the electrospray chamber parameters and the sheath liquid conditions. Optimum mass abundance of stereoisomers of ephedrine and related compounds was observed using the spray chamber parameters, namely 250 degrees C drying gas temperature and 8 L/min drying gas flow rate at a nebulizer pressure of 4 psi. Furthermore, the experimental design indicates that the optimum mass abundance of the stereoisomers of ephedrine and related compounds can be obtained using a sheath liquid containing 80:20 v/v methanol-water, 5 mM NH(4)OAc at pH 8.5 delivered at 5 microL/min. Finally, compared to MEKC-UV, the use of poly-L-SUCL in MEKC-MS provided significantly higher sensitivity for stereoisomers of ephedrine and related compounds.  相似文献   

3.
A capillary electrophoresis method with ultraviolet (UV) detection was developed and optimized for the enantiomer separation of norepinephrine (NE), epinephrine (EP) and isoprenaline (IP) using dual cyclodextrins (CDs) of 2-hydroxypropyl-beta-CD (HP-beta-CD) and heptakis (2,6-di-o-methyl)-beta-CD (DM-beta-CD) as chiral selectors. Optimal separation was obtained using a running buffer of 50mM phosphate containing 30mM HP-beta-CD and 5mM DM-beta-CD at pH 2.90 and a field strength of 20kV in 45cmx75mum (40cm effective length) uncoated capillary. The UV absorbance detection was set at 205nm. A 0.1% (w/w) polyethylene glycol or 0.1% (v/v) acetonitrile was used to enhance the detection sensitivity. There was a wide and excellent linear calibration graph for each enantiomer in the range 1.0x10(-3) to 1.0x10(-6)M and the detection limit (S/N=3) was found from 8.5x10(-7) to 9.5x10(-7)M. The method has been applied for the determination of isoprenaline in isoprenaline hydrochloride aerosol and to the analysis of serum samples. The recoveries of NE and EP in serum and IP in drug were ranged from 90 to 110%. The relative standard deviations of all the analyte peaks were less than 2.8% for migration time and less than 4.8% for peak area.  相似文献   

4.
A new micellar electrokinetic chromatographic method has been developed to analyse human urine samples containing a combination of a drug used for the treatment of breast cancer (letrozole), an antidepressant (citalopram) and their main metabolites. Best results were obtained by using 15 mM borate buffer (pH 9.2) containing 20 mM sodium dodecyl sulphate and 12% (v/v) 2-propanol as the background electrolyte. The separation was performed through a fused silica capillary at 40 degrees C with the application of 6s (3.45 kPa) of hydrodynamic injection and 30 kV of separation voltage. Detection wavelength was 240 nm. Under these conditions, the migration times for all the studied compounds were ranged between 3.0 and 8.0 min. Linearity ranges were determined as 0.4-5.0 microg/mL for all the compounds. Detection limits between 12.5 and 25 ng/mL were determined in urine samples. According to the validation study, the developed method has been proven to be accurate, precise, sensitive, specific, rugged and robust. This method has been used to determine letrozole, citalopram and their metabolites in human urine at clinical levels. Prior to determination, the samples are purified and enriched by means of an extraction-preconcentration step with a preconditioned C(18) cartridge and by eluting the compounds with methanol. The developed method was applied to the determination of these analytes in three urine samples from patients undergoing treatment with letrozole or citalopram.  相似文献   

5.
This article presents a new, simple and rapid continuous separation method by combination of flow injection with capillary electrophoresis designed for the analysis of basic traditional Chinese medicines. The device was produced using commercial capillary and components readily available in analytical laboratory. In double-T configuration, the designed horizontal separation channel was 25 microm i.d. x 146 mm length (an effective separation length of 93 mm) quartz capillary, with two vertical elicitation arms produced from 0.5 mm i.d. pump tubing. The capillary was embedded in a 40 x 20 x 3 mm organic glass base. Using the double-T configuration, continuous introduction of a series of samples was achieved. More than 3.00 resolution for ephedrine and pseudo-ephedrine were obtained using 100 mm borate buffer (pH 9.80) within 8 min in 25 microm separation channel with an electrical field strength of 137 V/cm (UV detection at 215 nm). The linear calibration range was 50-1500 microg/mL (ephedrine, r = 0.9982; pseudo-ephedrine, r = 0.9990) for both analytes. The limits of detection were 2.65 micro g/mL for ephedrine and 2.92 microg/mL for pseudo-ephedrine. In this device, the contents of ephedrine and pseudo-ephedrine in five Chinese medicinal preparations were determined with RSDs (n = 5) in range 1.16-4.51% and recoveries in range 90.4-114.6%.  相似文献   

6.
Capillary zone electrophoresis was developed to analyze low-molecular-mass organic acids including oxalic, tartaric, formic, malic, citric, succinic, glutaric, acetic and lactic acid. The influences of some crucial parameters such as buffer concentration, pH value, surfactant concentration and separation temperature, on electrophoretic separation were investigated. Under the conditions of 15 mM phthalate containing 0.6 mM tetradecyltrimethylammonium bromide as the run buffer (pH 5.6); separation voltage -15 kV (-263.2 V/cm) and temperature 25 degrees C, a satisfactory separation of nine organic acids was accomplished within 7 min. The detection limits (S/N=3) ranged from 0.008 to 0.08 microg/ml and the quantification limits ranged from 0.01 to 0.1 microg/ml for electrokinetic injection. The method was successfully applied to analyze organic acids in different parts of Var splendens (an edible vegetable in China). The recoveries of organic acids in real samples ranged from 88 to 121%.  相似文献   

7.
A micellar electrokinetic chromatography method is proposed for the determination of morphine, codeine, and paclitaxel at clinical relevant levels in human serum and plasma, which are employed in the treatment of patients with cancer. Optimal conditions for the separation were investigated. A background electrolyte solutions consisting of 20 mM borate buffer adjusted to pH 8.5, sodium dodecyl sulphate 60 mM and 15% methanol, hydrodynamic injection, and 25 kV as separation voltage were used. Detection wavelength was 212 nm for morphine and codeine and 200 nm for paclitaxel. Aspects such as stability of the solutions, linearity, accuracy, precision, and robust and ruggedness were examined in order to validate the proposed method. Detection limits obtained for all the studied compounds ranged between 26 and 52 ng/mL. Before micellar electrokinetic chromatography determination, the samples were purified and enriched by means of an extraction-preconcentration step with a preconditioned C(18) cartridge. This method was applied to the analysis of serum and plasma samples from different cancer patients undergoing treatment with paclitaxel or/and codeine.  相似文献   

8.
Li F  Ding Z  Cao QE 《Electrophoresis》2008,29(3):658-664
A CZE method using a complex of 2.5 mM Cu(II)-L-lysine (molar ratio is 1:2) as additive in a run buffer solution composed of Tris-H(3)PO(4) (pH 4.5) was developed for the simultaneous determination of ephedrine and pseudoephedrine within 4 min. The effects of pH, composition, and concentration of run buffer as well as the composition and concentration of the Cu(II)-L-lysine complex on the separation were investigated. The linear ranges for the determination of ephedrine and pseudoephedrine were 15.0-225.0 and 20.0-250.0 mg/L with LODs both of 5.0 mg/L. Satisfactory result for the determination of ephedrine and pseudoephedrine in Ephedrae Herba from different producing area was obtained by the proposed method. Ephedrine and pseudoephedrine were separated effectively with each other and with the other compounds in the sample. The RSD for the determination of the two constituents in the samples varied from 1.82 to 2.76%, and the recovery ranged between 95.0 and 104.0%.  相似文献   

9.
A cyclodextrin-modified capillary zone electrophoresis method was developed for the separation and determination of three isomeric compounds (ursolic acid, oleanolic acid and betulinic acid), caffeic acid, p-coumaric acid, rosmarinic acid, rutin and quercetin. Without the addition of beta-cyclodextrin (beta-CD) and methanol, the separation of these analytes was poorly resolved. These eight compounds, however, were well separated from each other within 20 min with a borax running buffer (40 mM of borax, pH 9.4) containing 2mM beta-CD and 4% (v/v) methanol at the voltage of 25 kV, temperature of 25 degrees C and detection wavelength of 210 nm. The relative standard deviations (RSDs) of migration time ranged from 0.16 to 0.74% while those of the peak area ratios ranged from 2.17 to 4.61% for six determinations of the analytes at concentration of 10 and 25 microg mL(-1). The correlation coefficients of the calibration curves of the analytes were all >0.998, and the recoveries were from 96.8 to 103.6%. The method was successfully applied to determine these bioactive components in the samples of Prunella vulgaris L. and its beverage drink products. Our results reveal that only the isomeric compounds and rosmarinic acid could be detected in the spikes of P. vulgaris L.; other components were either too low to be detected or not present while only rosmarinic acid was detected in the beverage products.  相似文献   

10.
MEKC was used for the separation of nine acetylcholinesterase inhibitors (AChEIs). AChEIs are an important group of drug compounds that are used medicinally to treat Alzheimer's disease and Myasthenia Gravis. At the time of the experiment, this is the first time that nine AChEIs are used simultaneously in a study. Several chromatographic parameters, such as buffer concentration, pH, surfactants and their concentration, background electrolyte composition, etc., were evaluated to optimize the separation. The optimum separation of the nine AChEIs was achieved in less than 15 min by using 12.5 mM Na(2)HPO(4), 12.5 mM Na(2)B(4)O(7) and 20 mM SDS at pH 10, an applied voltage of 30 kV and a temperature of 25 °C. The reproducibility of the method was also evaluated by computing the RSDs of the migration times and the areas of the nine analyte-peaks, and the migration time and the area of the peak that corresponds to rivastigmine added in the blood sample. The RSD values of the migration times and the peak areas were less than 2% and 6%, respectively, in most cases. The limits of detection and quantification were 0.5 μg/mL and 1.7 μg/mL, respectively. The MEKC method developed was applied to a real blood sample that was obtained from a patient who was not under any of this medication. The sample was spiked with rivastigmine in order to establish the ability of the method to separate the drug from other components that might exist in the blood sample.  相似文献   

11.
Ritalin, [(+)-threo]methylphenidate hydrochloride, is a chiral drug substance with two chiral centers. The drug substance may contain three pairs of enantiomers, [(+)-threo], [(-)-threo], [(+)-erythro] and [(-)-erythro] isomers, and its degradation products, threoritalinic acid racemate. Determination of the optical purity of ritalin drug substance and the amount of its by-product isomers is a critical step in the single-isomer drug development. In order to efficiently recognize the three pairs of enantiomers by one method, capillary electrophoresis (CE) was employed for the separation. The three pairs of enantiomers in CE showed different enantioselectivities with eight different types of CDs. Only 2,6-di-o-methyl-beta-cyclodextrin (DM-beta-CD) and carboxymethyl-beta-cyclodextrin (CM-beta-CD) showed enantioselectivity to all these pairs of enantiomers. With respect to separation resolution and efficiency, DM-beta-CD was chosen as the chiral selector. For optimization of the separation conditions, the concentration of DM-beta-CD, pH of the buffer solution, and temperature of the capillary were further studied.  相似文献   

12.
Tian K  Qi S  Cheng Y  Chen X  Hu Z 《Journal of chromatography. A》2005,1078(1-2):181-187
In this paper, a micellar electrokinetic chromatographic (MEKC) method using ionic liquid as modifier for the quantification of the active components of lignans found in the medicinal herbs Schisandra species was developed for the first time. Preliminary investigations employing sodium dodecyl sulfate (SDS) as surfactant did not lead to the necessary resolution of the studied compounds, the addition of ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate (BMIM-BF4) to the SDS micellar system resulted in the complete separation of all the compounds. The effects on the separation by several parameters such as BMIM-BF4 and SDS concentration, applied voltage, background electrolyte pH and concentration, were evaluated. Under the optimal conditions (5 mM borate-5 mM phosphate buffer in the presence of 20 mM SDS and 10 mM BMIM-BF4, pH 9.2, applied voltage 25 kV and detection at 254 nm), the method successfully applied to the determination of lignans in extracts of Schisandra chinensis (Turcz.) Baill. and Schisandra henryi C.B. Clarke in less than 13 min. The separation mechanism was also discussed.  相似文献   

13.
A method was developed for the determination of phosphoamino acids by capillary zone electrophoresis-laser-induced fluorescence detection (argon ion laser, excitation at 488 nm and emission at 520 nm) using derivatization with N-hydroxysuccinimidyl fluorescein-O-acetate (SIFA). Different variables affecting the derivatization (SIFA concentration, derivatization pH, reaction temperature and reaction time) and the separation (type, pH and concentration of buffer, applied voltage and injection mode) were investigated in detail. The optimized separation conditions were 40 mM boric acid buffer (pH 9.2) for background electrolyte, 25 kV for the separation voltage, 25 degrees C for the capillary temperature and 5 s at 0.5 psi for the sample injection. Under the optimal conditions, the SIFA-labeled phosphoamino acids were fully separated within 7 min. The detection limits ranged from 0.1 to 0.3 nM, which are the lowest values reported for capillary electrophoresis (CE) methods. The proposed methodology allowed the rapid, sensitive and selective determination of phosphoamino acids in hen egg yolk phosvitin by the standard addition method. The recovery of these compounds in real sample was 94.0-103.5%. The developed method surpasses previously published CE methods in terms of detection limit, separation time, stability and simplicity of the electrophoretic procedure.  相似文献   

14.
A new chiral derivatizing reagent, dehydroabietylisothiocyante (DHAIC), was synthesized and used for the enantiomeric separation of chiral compounds in capillary electrophoresis (CE). The synthetic route to obtain DHAIC is described. The separation conditions for the chiral separation of several chiral compounds, such as protein amino acids and chiral drug DOPA were optimized. Best results for the chiral separation of DHAIC derivatized amino acids and DOPA were obtained in a running buffer consisted of 50 mM borate (pH 9.5), 5 mM sodium dodecyl sulphate (SDS) and 20% acetonitrile for amino acids and 60 mM Na2HPO4 (pH 8.0), 17 mM SDS and 25% acetonitrile for DOPA. Under the conditions studied, chiral separation of five amino acids including Ser, Val, Ala, Thr, Cys and a chiral drug DOPA as their diastereomeric DHAIC derivatives has been achieved by micellar electrokinetic chromatography (MEKC).  相似文献   

15.
The analysis is described for separating seven beta-adrenergic blocking agents (atenolol, celiprolol, clorprenaline, fenoterol, metoprolol, propranolol, terbutaline) and clenbuterol (sympathomimetic beta-2 receptor stimulating agonist, decongestant and bronchodilator, illicit anabolic used in athletics) by CE with UV detection. In order to simultaneously separate all analytes, Tris-H3PO4 solution was applied containing titanium dioxide nanoparticles (TiO2 NPs) as BGEs. The effects of important factors, such as concentration of TiO2 NPs, optimum pH, run buffer concentration, and separation voltage, were investigated so as to achieve best CE separation. The eight analytes could be well separated applying a separation voltage of 15 kV in 75 mM Tris-H3PO4 buffer at a pH of 2.40, containing 6.0 x 10(-6) g/mL TiO2 NPs. Under these optimal conditions, the RSDs for peak areas and for migration times were less than 2.7 and 2.3%, respectively. The detection limits were 0.1 microg/mL for celiprolol, 0.1 microg/mL for propranolol, 0.2 microg/mL for fenoterol, 1.0 microg/mL for atenolol, 1.0 microg/mL for clenbuterol, 1.0 microg/mL for clorprenaline, 1.0 microg/mL for metoprolol, and 1.0 microg/mL for terbutaline. The proposed method was successfully applied for the rapid CE determination of the frequently applied antihypertensive beta-blocking compounds atenolol, metoprolol, terbutaline, and propranolol in pharmaceutical tablets.  相似文献   

16.
An analytical method for the determination of six sulfophenyl carboxylic acids, namely (p-sulfophenyl)acetic, 2-(p-sulfophenyl)propionic, 2-(p-sulfophenyl)butyric, 3-(p-sulfophenyl)butyric, 4-(p-sulfophenyl)butyric, and 5-(p-sulfophenyl)valerianic acid, in agricultural irrigation water samples was developed. It involves an SPE procedure, an on-line preconcentration normal stacking mode and subsequent separation and determination using CE with UV detection (CE-UV). p-Sulfobenzoic acid was used as internal standard. The compounds were separated with an uncoated capillary and a 25 mM ammonium acetate/acetic acid buffer solution (pH 5.5) with 2-propanol (30% v/v) and 0.75 mM CTAB. Analyses were run at -25 kV, 25 degrees C, and 100 s of hydrodynamic injection with UV detection at 225 nm. Quantification limits found ranged between 4 and 6 ng/mL. The proposed method was validated using a recovery assay. It was satisfactorily used for the determination of these compounds in groundwater samples to track down the biodegradation of linear alkylbenzene sulfonates in an agricultural soil from the fertile plain of Granada (Spain).  相似文献   

17.
A simple CZE method has been developed for the simultaneous determination of eight polyphenolic compounds. The influence of several experimental conditions such as buffer (concentration and pH) and temperature were studied. Optimum separation was achieved in less than 25 min by using a BGE of 50 mM Na(2)B(4)O(7) and 10 mM Na(2)HPO(4) at pH 9.6, a temperature of 25°C and an applied voltage of 25 kV. Good linearities for all eight analytes were obtained with correlation coefficients higher than 0.99. The LODs were between 0.03 and 5.05 μg/mL and the RSD values of the migration times were found to be less than 1%. The optimal separation conditions were then used for the identification and the quantitation of polyphenolic compounds in Cypriot wine samples using six different sample preparation procedures. In particular, two direct injection methods (without any extraction step), three different liquid-liquid extraction procedures and an SPE procedure were examined. These sample pre-treatment methods were also compared in order to determine the one that is the most effective, in regard to analyte recovery, time, difficulty, and reproducibility. Liquid-liquid extraction using diethyl ether as the organic solvent proved to be the most effective.  相似文献   

18.
The method of liquid-phase microextraction assisted with voltage was developed and applied on determination of quinolones in water sample in this study. Both of the reproducibility and extraction time were improved with the aid of applying voltage. Four analytes in neutral state such as cinoxacin, oxolinic acid, nalidixic acid, and flumequine were extracted from a sample solution at pH 2.0, through a polypropylene hollow fiber which was immobilized with 2-octanone, and then into a 25 μL of the acceptor phase of 40 mM borate buffer at pH 10.0 by applying voltage of 100 V. Subsequently, the acceptor solution was directly subjected to analysis by LC-MS. The performance of the method for four quinolones was also evaluated. Linearity was obtained in the range of 1.0-25.0 ng/mL with R(2) > 0.996. Limits of detection were below 0.6 ng/mL, and recoveries of water sample were ranged from 90.8 to 109.6%.  相似文献   

19.
Using cyclodextrin capillary zone electrophoresis (CD-CZE), baseline separation of synthetic potential analgesic drug diastereoisomer candidates 6,11-dimethyl-1,2,3,4,5,6-hexahydro-3-[(2'-methoxycarbonyl-2'-phenylc yclopropyl)methyl]-2,6-methano-3-benzazocin-8-ol (MPCB) and 6,11-dimethyl-1,2,3,4,5,6-hexahydro-3-[[2'-methoxycarbonyl-2'(4-chloroph enyl)cyclopropyl]methyl]-2,6-methano-3-benzazocin-8-ol (CCB) was achieved. Among the cyclodextrins tested (hydroxypropyl-, carboxymethyl- and sulfobutyl-beta-cyclodextrin (HP-beta-CD, CM-beta-CD and SBE-beta-CD)) SBE-beta-CD was found to be the most effective complexing agent, allowing good optical isomer separation. Resolution was also influenced by the CD concentration, pH of the buffer and presence of organic modifier in the background electrolyte. The optimum experimental conditions for the separation of studied analgesic drugs were found using 25 mM borate buffer at pH 9 containing 40 mM of SBE-beta-CD and 20% v/v of methanol. Using the above-mentioned background electrolyte, it was also possible to separate, in the same run, the enantiomers of normetazocine (NMZ) as well as the optical isomers of (+/-)-cis-2-chloromethyl-1-phenyl cyclopropancarboxylic acid methyl ester (PCE) or (+/-)-cis-2-chloromethyl-1-(4-chlorophenyl)cyclopropancarboxylic acid methyl ester (CPCE) reagents used in the synthesis of the studied analgesic drugs).  相似文献   

20.
Zheng ZX  Lin JM  Chan WH  Lee AW  Huie CW 《Electrophoresis》2004,25(18-19):3263-3269
A novel chiral microemulsion, which involved the use of chiral alcohols as cosurfactants, was demonstrated for the enantiomeric separation of a number of pharmaceutical drugs in microemulsion electrokinetic chromatography (MEEKC). The chiral alcohols investigated were optically active 2-alkanols, with the alkyl chain length having carbon number ranging from 4 to 7. The data indicated that, except for R-(-)-2-butanol, the use of R-(-)-2-pentanol, R-(-)-2-hexanol or R-(-)-2-heptanol as the chiral cosurfactant resulted in the baseline or partial resolution of most of the test solutes, i.e., (+/-)-norephedrine, (+/-)-ephedrine, DL-nadolol, and DL-propranolol. In addition to the chain length of the chiral 2-alkanols, the effects of other experimental conditions, such as the concentration and chirality of the 2-alkanols, as well as the pH of the run buffer and the oil phase of the microemulsion, on the enantiomeric separation of the test solutes were also investigated. An interesting finding was that the water-immiscible organic solvent (oil core) within the microemulsion droplets appeared to play an important role in the chiral separation mechanism. Also, the importance of hydrogen bonding between the test solutes ((+/-)-ephedrine and related compounds) and the chiral microemulsion was demonstrated, as it was not possible to resolve a pair of enantiomers which lacked a beta-amino proton (i.e., (+/-)-N-methyl ephedrine) under optimized run buffer conditions (e.g., 5.0% R-(-)-2-hexanol, 0.8% n-octane, and 3.5% SDS in 90.7% borate buffer at pH 9.2).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏