首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ye X  Tao LJ  Needham LL  Calafat AM 《Talanta》2008,76(4):865-871
We developed a method using on-line solid phase extraction (SPE) coupled to high performance liquid chromatography–isotope dilution tandem mass spectrometry (HPLC–MS/MS) to measure the serum concentrations of seven environmental phenols and five parabens: bisphenol A; ortho-phenylphenol; 2,4-dichlorophenol; 2,5-dichlorophenol; 2,4,5-trichlorophenol; benzophenone-3; triclosan; and methyl-, ethyl-, propyl-, butyl-, and benzyl-parabens. The phenols and parabens present in serum were retained and concentrated on a C18 reversed-phase size-exclusion SPE column, back-eluted from the SPE column while the eluate was diluted through a mixing Tee (analyte peak focusing), separated using a pair of monolithic HPLC columns, and detected by isotope dilution-MS/MS. Sample preparation did not require protein precipitation, only dilution of the serum with 0.1 M formic acid. This method, which combines an on-line SPE with analyte peak focusing feature and the selective atmospheric pressure photoionization MS detection, resulted in limits of detection ranging from 0.1 to 0.5 ng/mL for most of the analytes. The high throughput and adequate sensitivity with yet a relative low serum volume used (100 μL) confirm that analytically it is possible to measure simultaneously these phenols and parabens with the precision and accuracy at sub-parts-per-billion levels required for biomonitoring. However, important additional factors, including validated sample collecting, handling, and storing protocols, as well as toxicokinetic data, are required if these measures are used for exposure assessment.  相似文献   

2.
陈静  刘召金  戴振宇  安保超  许群  张祥民 《色谱》2013,31(9):894-897
建立了一个简单、快速、有效的适用于质谱或液相色谱-质谱联用的在线固相萃取(SPE)高通量除盐方法。方法分为单柱和双柱模式,借助于包含双梯度泵(上样泵/分析泵)、自动进样器和配有十通切换阀的柱温箱的高效液相色谱系统,完成样品的自动化在线除盐。单柱模式通过上样泵实现在SPE柱上进样和除盐,被分析物则保留在SPE柱上;除盐完成后,通过阀切换利用分析泵洗脱富集在SPE柱上的被分析物。双柱模式则在单柱模式基础上增加了1根SPE柱,在色谱管理软件控制下2根SPE柱轮流工作,高效率完成样品的在线除盐。该方法在结合质谱分析蛋白质、多肽等领域具有较好的应用前景。  相似文献   

3.
An on-line liquid chromatography/tandem mass spectrometry (LC-MS/MS) procedure, using the Prospekt- 2 system, was developed and used for the determination of the levels of the active ingredients of cough/cold medications in human plasma matrix. The experimental configuration allows direct plasma injection by performing on- line solid phase extraction (SPE) on small cartridge columns prior to elution of the analyte(s) onto the analytical column and subsequent MS/MS detection. The quantitative analysis of three analytes with differing polarities, dextromethorphan (DEX), dextrorphan (DET) and guaifenesin (GG) in human plasma presented a significant challenge. Using stable-isotope-labeled internal standards for each analyte, the Prospekt-2 on-line methodology was evaluated for sensitivity, suppression, accuracy, precision, linearity, analyst time, analysis time, cost, carryover and ease of use. The lower limit of quantitation for the on-line SPE procedure for DEX, DET and GG was 0.05, 0.05 and 5.0 ng mL(-1), respectively, using a 0.1 mL sample volume. The linear range for DEX and DET was 0.05-50 ng mL(-1) and was 5-5,000 ng mL(-1) for GG. Accuracy and precision data for five different levels of QC samples were collected over three separate days. Accuracy ranged from 90% to 112% for all three analytes, while the precision, as measured by the %RSD, ranged from 1.5% to 16.0%  相似文献   

4.
软骨藻酸(domoic acid, DA)是一种由海洋硅藻产生的生物毒素,具有强烈的神经毒性,近海水环境中的DA严重威胁海洋渔业生物和人类健康,因此对近海水环境中的DA进行有效监测至关重要。该文基于固相萃取-液相色谱-串联质谱联用技术(SPE-LC-MS/MS),建立了适用于海水中痕量、超痕量DA的检测方法。针对近海水生环境中DA浓度相对较高的情况下,采用在线SPE-LC-MS/MS检测模式,可减少前处理过程,提高样品的分析效率。离线SPE结合在线SPE-LC-MS/MS可实现大洋和极地海水中含量更低的DA的检测。通过对在线固相萃取条件和液相色谱、质谱条件的优化,海水样品经过滤和酸化简单处理后直接进样0.6 mL进行在线SPE-LC-MS/MS检测,DA在10.0~500.0 ng/L范围内线性关系良好(线性相关系数R2=0.9992),检出限(LOD)和定量限(LOQ)分别为4.0和10.0 ng/L,并且具有较好的方法回收率(≥81.0%)和精密度(RSD≤4.2%),表明方法可用于近海海水中痕量DA的检测。通过对离线固相萃取柱的选择和酸化条件的优化,80.0 mL海水样品经离线HLB固相萃取柱富集后,进行在线SPE-LC-MS/MS检测,DA在0.3~50.0 ng/L范围内线性关系良好(R2=0.9990),回收率(≥69.2%)和精密度(RSD≤4.4%)较好,LOD和LOQ分别为0.1和0.3 ng/L,说明方法的灵敏度较直接进样法大幅提升,实现了海水中超痕量DA的准确测定。这两种检测方法操作简单,样品用量小,灵敏度高,可满足近海养殖区及远岸海水中DA监测的要求。  相似文献   

5.
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min.  相似文献   

6.
An on-line solid-phase extraction liquid chromatography/tandem mass spectrometry (SPE LC/MS/MS) assay using a newly developed SPE column and a monolithic column was developed and validated for direct analysis of plasma samples containing multiple analytes. This assay was developed in an effort to increase bioanalysis throughput and reduce the complexity of on-line SPE LC/MS/MS systems. A simple column-switching configuration that requires only one six-port valve and one HPLC pumping system was employed for on-line plasma sample preparation and subsequent gradient chromatographic separation. The resulting analytical method couples the desired sensitivity with ease of use. The method was found to perform satisfactorily for direct plasma analysis with respect to assay linearity, specificity, sensitivity, precision, accuracy, carryover, and short-term stability of an eight-analyte mixture in plasma. A gradient LC condition was applied to separate the eight analytes that cannot be distinctly differentiated by MS/MS. With a run time for every injection of 2.8 min, a minimum of 300 direct plasma injections were made on one on-line SPE column without noticeable changes in system performance. Due to the ruggedness and simplicity of this system, generic methods can be easily developed and applied to analyze a wide variety of compounds in a high-throughput manner without laborious off-line sample preparation.  相似文献   

7.
采用自动前处理LC/MS进行血浆中药物的快速分析   总被引:3,自引:0,他引:3  
药物研究的发展对高通量的样品处理分析提出了越来越高的要求,减少样品制备时间和分析时间是解决问题的关键。我们新近发展了一种具有在线稀释旁路和新的样品预处理柱的Shim-Pack MAYI-ODS自动柱切换HPLC和LC/MS系统,该系统无需样品前处理,可直接进样进行血浆、血清中的药物分析。本文利用自动样品前处理LC/MS系统,用ODS整体柱实现了血浆中药物的快速分析。包括样品预处理,整个分析仅需1.2min完成。  相似文献   

8.
A method using automated on-line solid-phase extraction (SPE) liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of 8-iso-PGF2α in human exhaled breath condensate (EBC) was developed and validated. A C18 SPE column with an affinity sorbent was used for on-line extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. 8-iso-PGF2α-d4 was used as an internal standard for quantitative determination. The extraction, cleanup and analysis procedures were controlled by a fully automated six-port switch valve. Identification and quantification were based on the following transitions: m/z 353 → 193 for 8-iso-PGF2α and m/z 357 → 197 for 8-iso-PGF2α-d4, respectively. Good recoveries from 98.94 to 99.86% were measured and satisfactory linear ranges for these analytical compounds were determined. Intra-day and inter-day precision showed that coefficients of variance (CV) ranged from 6.5 to 8.0% and 5.2 to 6.3%, respectively. The applicability of this newly developed method was demonstrated by analyzing human EBC samples for an evaluation of the future risk of human exposure to nanoparticles.  相似文献   

9.
建立了同时检测水稻中6种内源性植物激素脱落酸( Abscisic acid,ABA)、吲哚-3-乙酸( Indole-3-acetic acid, IAA)、水杨酸( Salicylic acid,SA)、茉莉酸( Jasmonic acid,JA)、吲哚-3-丙酸( Indole-3-propionic acid, IPA)和吲哚-3-丁酸( Indole-3-butyric acid,IBA)的全自动在线固相萃取-液相色谱-串联质谱方法。植物样品经过甲醇提取,采用C18固相萃取柱富集净化,流动相将待测物洗脱至C18分析色谱柱进行分离,最终使用串联四极杆质谱进行检测。方法的线性范围为8~320μg/L,相关系数为R2≥0.99;方法的检出限(S/N=3)范围为0.1~0.8μg/kg;实际样品中方法回收率范围为71.2%~126%,RSD<13%。应用本方法快速、准确地检测了水稻幼穗中多种内源性植物激素的含量,并与目前植物学领域内常用的检测方法进行了比较。同时,本方法对水稻受伤叶片的内源植物激素含量变化进行了定量分析,其含量随受伤时间的变化趋势与其生物背景的实验结果相吻合。  相似文献   

10.
In this study, an automated on-line solid-phase extraction coupled to fast liquid chromatography–tandem mass spectrometry (on-line SPE fast LC–MS/MS) method was developed for the simultaneous analysis of bisphenol A (BPA), bisphenol F (BPF), bisphenol E (BPE), bisphenol B (BPB) and bisphenol S (BPS) in canned soft drinks without any previous sample treatment. A C18 (12 μm particle size) loading column was used for the SPE on-line preconcentration before the liquid chromatography baseline separation of bisphenol compounds using a C18 Fused-Core™ (50 mm × 2.1 mm i.d.) column, which took less than 3 min. Gradient elution and heated electrospray were used to reduce matrix effect and improve ionization efficiency. To select the most intense and selective transitions, fragmentation studies were performed by multiple-stage mass spectrometry in an ion trap mass analyzer and tandem mass spectrometry in a triple quadrupole instrument, this latter instrument being used for quantitation in SRM mode. Quality parameters of the method were established and we obtained a simple, fast, reproducible (RSD values lower than 10%) and accurate (precision higher than 93%) method for the analysis of bisphenols in canned soft drinks at the ng L−1 level using matrix-matched calibration.  相似文献   

11.
A method using automated on-line solid phase extraction (SPE) directly coupled to liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed for the analysis of six pharmaceuticals by isotope dilution. These selected pharmaceuticals were chosen as representative indicator compounds and were used to evaluate the performance of the on-line SPE method in four distinct water matrices. Method reporting limits (MRLs) ranged from 10 to 25 ng/L, based on a 1 mL extraction volume. Matrix spike recoveries ranged from 88 to 118% for all matrices investigated, including finished drinking water, surface water, wastewater effluent and septic tank influent. Precision tests were performed at 50 and 1000 ng/L with relative standard deviations (RSDs) between 1.3 and 5.7%. A variety of samples were also extracted using a traditional off-line automated SPE method for comparison. Results for both extraction methods were in good agreement; however, on-line SPE used approximately 98% less solvent and less time. On-line SPE coupled to LC-MS/MS analysis for selected indicators offers an alternative, more environmentally friendly, method for pharmaceutical analysis in water by saving time and costs while reducing hazardous waste and potential environmental pollution as compared with off-line SPE methods.  相似文献   

12.
A 2D liquid chromatography (LC) system using hydrophilic interaction chromatography (HILIC) and reversed phase columns has been employed for comprehensive (LC × LC) separation of rat muscle tissue micro-dialysate. Incorporation of an on-line reverse-phase solid phase extraction (SPE) enrichment column in front of the first dimension enabled aqueous samples with high salt concentrations to be injected directly without compromising the chromatographic performance of the HILIC column. Since the SPE enrichment column allowed injection of large sample volumes (e.g. 450 μL), a capillary HILIC column (inner diameter 0.3 mm) could be employed instead of a larger column which is often used in the first dimension to load sufficient amounts of sample. The two chromatographic dimensions were connected using a column selector system with 18, 1.0 mm I.D. C18 “transition” SPE columns. A PLRP C18 column was used in the second dimension. The 2D LC system’s performance was evaluated with a tryptic digest mixture of three model proteins. Good trapping accuracy (HILIC→transition SPE→RP recovery >95%) and repeatability (within-and between day retention time RSDs of first and second dimension chromatography >1%) was achieved. A dialysis sample of rat muscle tissue was separated with the 2D system, revealing complexity and large differences in concentrations of the various compounds present, factors which could potentially interfere with the quantification and monitoring of two target analytes, arg-bradykinin and bradykinin. Subsequently, “Heart-cut” 2D LC-electrospray–mass spectrometry (ESI–MS) with post-column on-line standard injection was employed to monitor arg-bradykinin and bradykinin levels as a function of various muscle conditions. The method’s quantification precision was RSD = 3.4% for bradykinin.  相似文献   

13.
This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L−1.This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L−1).  相似文献   

14.
A high-throughput bioanalytical method for simultaneous quantitation of pravastatin and its metabolite (M1) in human serum was developed and validated using on-line extraction following liquid chromatography tandem mass spectrometry (LC-MS/MS). The on-line extraction was accomplished by the direct injection of a 50 microL serum sample, mixed 4:1 with an aqueous internal standard solution, into one of the extraction columns with aqueous 1 mm formic acid at flow rate of 3 mL/min. The separation and analysis were achieved by back-eluting the analytes from the extraction column and the analytical column to the mass spectrometer with an isocratic mobile phase consisting of 62% aqueous 1 mm formic acid and 38% acetonitrile at a flow rate of 0.8 mL/min. The second extraction column was being equilibrated while the first column was being used for analysis, and vice versa. The standard curve range was 0.500-100 ng/mL for pravastatin and M1. The lower limit of quantitation, 0.500 ng/mL for all the analytes, was achieved when 50 microL of human serum was used. The intra- and inter-day precisions were within 7.4%, and the accuracy was between 95 and 103%. The on-line extraction was finished in 0.5 min and total analysis time was 2.5 min per sample.  相似文献   

15.
The presented procedure combines experience from two LC-MS/MS methods previously developed by our team for NSAIDs determination in meat and milk. The novelty was a modification of sample preparation and combining LC-MS/MS method for milk and muscle. The clean-up procedure was investigated, leading to a change from SPE to dSPE with C18 bulk sorbent. Unlike most of the existing methods, chromatographic separation was achieved on a C8 chromatographic column. This method was developed and validated under European Commission Decision 2002/657/EC. Recovery for milk samples values between 86.3% to 108%, with the coefficient of variation, varied from 5.51% to 16.2%. The recovery for muscle was calculated to be between 85.0% and 109%, and the coefficient of variation was—4.73% to 16.6%. The validation results prove that the method is suitable for confirmatory purposes in milk and muscle. Of 452 samples tested in 2019 and 2020, two have been identified as non-compliant.  相似文献   

16.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry (LC-MS/MS) quantitative detection method, using cefalexin as internal standard, was developed for the analysis of faropenem in human plasma and urine. After precipitation of the plasma proteins with acetonitrile, the analytes were separated on a C18 reversed-phase column with 0.1% formic acid-methanol (45:55, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves with good linearities (r=0.9991 for plasma sample and r=0.9993 for urine sample) were obtained in the range 5-4000 ng/mL for faropenem. The limit of detection was 5 ng/mL. Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of faropenem in humans, and to our knowledge, it is the first time the pharmacokinetic of faropenem has been elucidated in vivo using LC-MS/MS.  相似文献   

17.
The presence of pesticide residues in water is a huge worldwide concern. In this paper we described the development and validation of a new liquid chromatography tandem mass spectrometric (LC-MS/MS) method for both screening and quantification of pesticides in water samples. In the sample preparation stage, the samples were buffered to pH 7.0 and pre-concentrated on polymeric-based cartridges via solid-phase extraction (SPE). Highly sensitive detection was carried out with mobile phases containing only 5 mM ammonium formate (pH of 6.8) as an eluent additive and using only positive ionization mode in MS/MS instrument. Hence, only 200-fold sample enrichment was required to set a screening detection limit (SDL) and reporting limit (RL) of 10 ng/L. The confirmatory method was validated at 10 and 100 ng/L spiking levels. The apparent recoveries obtained from the matrix-matched calibration (5–500 ng/L) were within the acceptable range (60–120%), also the precision (relative standard deviation, RSD) was not higher than 20%. During the development, 480 pesticides were tested and 330 compounds fulfilled the requirements of validation. The method was successfully applied to proficiency test samples to evaluate its accuracy. Moreover, the method robustness test was carried out using higher sample volume (500 mL) followed by automated SPE enrichment. Finally, the method was used to analyze 20 real samples, in which some compounds were detected around 10 ng/L, but never exceeded the assay maximum level.  相似文献   

18.
An automated on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) system was developed for the determination of macrolide antibiotics including erythromycin (ETM), roxithromycin (RTM), tylosin (TLS) and tilmicosin (TMC) in environmental water samples. A Capcell Pak MF Ph-1 column packed with restricted access material (RAM) was used as SPE column for the concentration of the analytes and clean-up of the sample. One milliliter water sample was injected into the conditioned SPE column and the matrix was washed out with 3 mL high purity water. By rotation of the switching valve, macrolides (MLs) were eluted in the back-flush mode and transferred to the analytical column by the chromatographic mobile phase. The matrix effect was evaluated by the directly injection LC-MS and on-line SPE-LC-MS methods. The limits of detection (LODs) and limits of quantification (LOQs) obtained are in the range of 2-6 and 7-20 ng L−1, respectively, which means that the proposed method is suitable for trace analysis of MLs at low level concentration. The intra- and inter-day precisions are in the range of 2.9-7.2% and 3.3-8.9%, respectively. In the three fortified levels (20, 200 and 2000 ng L−1), recoveries of MLs ranging from 86.5% to 98.3% are obtained.  相似文献   

19.
Bones J  Macka M  Paull B 《The Analyst》2007,132(3):208-217
A study comparing recently available 100 x 3 mm id, 200 x 3 mm id monolithic reversed-phase columns with a 50 x 2.1 mm id, 1.8 microm particle packed reversed-phase columns was carried out to determine the most efficient approach (using traditional van Deemter analysis and a modern kinetic plot approach) for the rapid screening of samples for 16 illicit drugs and associated metabolites. A plot of column backpressure versus plate number (N) showed a significant advantage of using the monolithic phases, with the 20 cm monolithic column exhibiting a maximum 15,000 plates at a column backpressure of approximately 70 bar, compared to approximately 7000 plates at 150 bar for the 5 cm 1.8 microm particle packed column. Optimum linear velocities were found to be 0.40 mm s(-1), 0.52 mm s(-1) and 0.98 mm s(-1) for the three above columns, respectively. The 20 cm monolithic column was subsequently applied to the separation and determination of illicit drug contamination on Irish euro banknotes, using methanol extraction followed by LC-MS/MS. Method performance data showed that the new LC-MS/MS method was significantly more sensitive than previous GC-MS/MS based methods for this application, with detection limits in the pg note(-1) region, based upon a 20 microL standard injection. All of the notes examined tested positive for trace quantities of cocaine, with benzoylecgonine detected on 12 of the 45 notes sampled. Traces of heroin were also detected on three of the 45 notes.  相似文献   

20.
Restricted access material (RAM) has been used in the packing of a solid-phase extraction (SPE) column for on-line extractions under turbulent flow conditions. The bio-compatible RAM material works by the principle of size exclusion in addition to conventional reversed-phase chromatography, thereby allowing the extraction and preconcentration of small analyte molecules from biological samples such as plasma. Using small column dimensions (0.76 mm x 50 mm) and a consequently high linear velocity, turbulent flow was achieved during online sample extractions. The improved mass-transfer rate characteristic of turbulent flow allows fast sample cleanup without decreased extraction efficiency. The novel use of the RAM column, connected upstream to a C18 monolithic column, allowed the direct injection, extraction, separation, and MS/MS detection of plasma samples spiked with rofecoxib in a span of 5 min. Calibration curves obtained using this RAM turbulent flow coupled column method showed good linearity (R2 > 0.99) and reproducibility (%RSD < or = 7%). The lower limit of quantitation of rofecoxib in plasma samples was found to be 40 ng/ml. The extraction method showed good recovery of rofecoxib from a plasma matrix with minimal signal loss and robustness after more than 200 plasma injections.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号