首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ye F  Xie Z  Wong KY 《Electrophoresis》2006,27(17):3373-3380
A silica-based monolithic column as polar stationary phase is proposed for pressurized CEC (pCEC). The monolithic silica matrix from a sol-gel process was chemically modified by 3-aminopropyltrimethoxysilane to produce a column for hydrophilic interaction applications. The amino groups on the surface of the polar stationary phase generated anodic EOF under acidic conditions and served at the same time as a weak anion-exchanger. The anion solutes such as nucleotides were separated by the mixed mode mechanism, which comprised hydrophilic interaction, weak anion-exchange, and electrophoresis. The influences of buffer concentration and organic modifier content on the separation of nucleotides by pCEC have been investigated. In addition, the monolithic silica columns were also able to separate various polar compounds such as phenols, nucleic acid bases, and nucleosides in the hydrophilic interaction CEC mode.  相似文献   

2.
A polar and neutral polymethacrylate-based monolithic column was evaluated as a hydrophilic interaction capillary electrochromatography (HI-CEC) stationary phase with small polar–neutral or charged solutes. The polar sites on the surface of the monolithic solid phase responsible for hydrophilic interactions were provided from the hydroxy and ester groups on the surface of the monolithic stationary phase. These polar functionalities also attract ions from the mobile phase and impart the monolithic solid phase with a given zeta potential to generate electro-osmotic flow (EOF). The monolith was prepared by in situ copolymerization of a neutral monomer 2-hydroxyethyl methacrylate (HEMA) and a polar cross-linker with hydroxy group, pentaerythritol triacrylate (PETA), in the presence of a binary porogenic solvent consisting cyclohexanol and dodecanol. A typical HI-CEC mechanism was observed on the neutral polar stationary phase for both neutral and charged analytes. The composition of the polymerization mixture was systematically altered and optimized by altering the amount of HEMA in the polymerization solution as well as the composition of the porogenic solvent. The monoliths were tested in the pCEC mode. The resulting monoliths had different characteristics of hydrophilicity, column permeability, and efficiency. The effects of pH, salt concentration, and organic solvent content on the EOF velocity and the separation of nucleic acids and nucleosides on the optimized monolithic column were investigated. The optimized monolithic column resulted in good separation and with greater than 140,000 theoretical plates/m for pCEC.  相似文献   

3.
Lin J  Liu S  Lin J  Lin X  Xie Z 《Journal of chromatography. A》2011,1218(29):4671-4677
A novel highly hydrophilic polymethacrylate-based monolithic stationary phase based on the copolymerization of 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) and pentaerythritol triacrylate (PETA) was designed for pressurized capillary electrochromatography. A typical hydrophilic interaction chromatography mechanism could be observed when the content of acetonitrile (ACN) in the mobile phase exceeded 25%. Slight swelling or shrinking with mobile phases of different polarity was observed in permeability studies. Good retentions and efficient separations of polar analytes, such as neutral amides and phenols, were well achieved in hydrophilic interaction chromatography mode with only about 50% ACN content in the mobile phase. It was remarkably lower than the content of ACN (>90%) used on the hydrophilic polymethacrylate-based monoliths reported previously. Additionally, a mixed mode of hydrophilic interaction (HI) and strong cation-exchange (SCX) could be also obtained in the analysis of charged peptides, and high column efficiency up to 80,000 plates/m was achieved without peak tailing. The prepared hydrophilic stationary phase might provide a potential environmental friendly separation media for polar solutes as it consumes a low volume of organic solvents.  相似文献   

4.
A monolithic silica based strong cation-exchange stationary phase was successfully prepared for capillary electrochromatography. The monolithic silica matrix from a sol-gel process was chemically modified by treatment with 3-mercaptopropyltrimethoxysilane followed by a chemical oxidation procedure to produce the desired function. The strong cation-exchange stationary phase was characterized by its substantial and stable electroosmotic flow (EOF), and it was observed that the EOF value of the prepared column remained almost unchanged at different buffer pH values and slowly decreased with increasing phosphate concentration in the mobile phase. The monolithic silica column with strong cation-exchange stationary phase has been successfully employed in the electrochromatographic separation of beta-blockers and alkaloids extracted from traditional Chinese medicines (TCMs). The column efficiencies for the tested beta-blockers varied from 210,000 to 340,000 plates/m. A peak compression effect was observed for atenolol with the mobile phase having a low phosphate concentration.  相似文献   

5.
Lin J  Huang G  Lin X  Xie Z 《Electrophoresis》2008,29(19):4055-4065
A novel porous polymethacrylate-based monolithic column by in situ copolymerization of 3-sulfopropyl methacrylate (SPMA) and pentaerythritol triacrylate in a binary porogenic solvent consisting of cyclohexanol/ethylene glycol was prepared. The monolith possessed in their structures bonded sulfonate groups and hydroxyl groups and was evaluated as a hydrophilic interaction and strong cation-exchange stationary phases in capillary liquid chromatography (cLC) and pressure-assisted CEC using small polar neutral and charged solutes. While the SPMA was introduced as multifunctional monomer, the pentaerythritol triacrylate was used to replace ethylene glycol dimethacrylate as cross-linker with much more hydrophilicity due to a hydroxyl sub-layer. The different characterization of monolithic stationary phases were specially designed and easily prepared by altering the amount of SPMA in the polymerization solution as well as the composition of the porogenic solvent for cLC and pressure-assisted CEC. The resulting monolith showed the different trends about the effect of the permeabilities on efficiency in the pressure-assisted CEC and cLC modes. A typical hydrophilic interaction chromatography mechanism was observed at higher organic solvent content (ACN%>70%) for polar neutral analytes. For polar charged analytes, both hydrophilic interaction and electrostatic interaction contributed to their retention. Therefore, for charged analytes, selectivity can be readily manipulated by changing the composition of the mobile phase (e.g., pH, ionic strength and organic modifier). With the optimized monolithic column, high plate counts reaching greater than 170 000 plates/m for pressure-assisted CEC and 105 000 plates/m for cLC were easily obtained, respectively.  相似文献   

6.
Huang G  Lian Q  Zeng W  Xie Z 《Electrophoresis》2008,29(18):3896-3904
A silica-based monolith as polar stationary phase was described for hydrophilic interaction pressurized capillary electrochromatography (HI-pCEC). The polar monolithic column was prepared by on-column reaction of lysine with epoxy groups on a gamma-glycidoxypropyltrimethosysilane-modified silica monolith. The stationary phase yielded strong hydrophilic interaction due to the slightly polar hydroxyl groups, and the strong polar lysine ligand with amino groups and carboxylic groups contained on the surface of the monolith. In order to evaluate the hydrophilic character of lysine ligand, the chromatographic behaviors of epoxy monolith (before lysine bonded) and diol monolith (hydroxyl groups contained) were also investigated. Two groups of comparative experiment were developed in terms of the separation of typical neutral non-polar and polar compounds performed in a mobile phase of aqueous-acetonitrile solution. Results showed that the lysine monolith was much more hydrophilic than the diol monolith, which presented less hydrophobic than the epoxy monolith. For further study on its hydrophilic character, the lysine monolith was demonstrated in the HI-pCEC mode for the separations of various polar compounds such as phenols, nucleic acid bases and nucleosides.  相似文献   

7.
亲水作用毛细管电色谱是当前微分离技术的研究热点之一,其固定相的研究受到了广泛的关注。本文介绍了亲水作用毛细管电色谱开管柱、填充柱和整体柱的研究进展,重点对近年来发展的亲水作用电色谱整体柱的制备技术进行了系统阐述。引用文献68篇。  相似文献   

8.
A silica-based monolithic stationary phase prepared by the sol-gel process in a 100 microm I.D. fused-silica (FS) capillary has been modified chemically with 3-mercaptopropyl trimethoxysilane followed by immobilization of a strong cation-exchange (SCX) type chiral selector, (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutane phosphonic acid, by radical addition reaction onto the reactive sulfhydryl surface. After a fine-tuning of the mobile phase composition, the enantioselective capillary column was evaluated for the separation of various chiral basic drugs by enantioselective non-aqueous capillary electrochromatography (CEC), in comparison to capillary column analogs packed with 3.5 microm silica particles having attached the same selector. The performance of the monolithic silica column was further compared to corresponding polymethacrylate-based organic polymer monoliths. The study indicated that strong counter-ions such as 2-aminobutanol or N,N,N',N'-tetramethylethylenediamine are needed, although they reduce the electroosmotic flow velocity and separation factors in comparison to less efficient counter-ions, in order to allow the elution of the oppositely charged solutes in the ion-exchange retention mode within reasonable run time and as sharp zones. In contrast, weak counter-ions such as N,N-diisopropylethylamine (Huenig base) provided stronger electroosmotic flow and much better separation factors, but relatively poor peak efficiencies. Overall, with the chemically functionalized monolithic silica column the high quality separations of packed column analogs could be approximated, with regards to both separation factors and peak performances. On the other hand, the monolithic capillary column certainly outperformed the packed column in terms of system robustness under capillary electrochromatography conditions and showed excellent column longevity. The enantioselective strong cation-exchange-type monolithic silica column performed also well in comparison to the organic polymer monolith.  相似文献   

9.
胡静  刘让东  王薇薇  王彦  闫超 《色谱》2019,37(5):551-557
采用改良Stöber法合成580 nm亚微米单分散的二氧化硅微球,并以此为基质,通过"巯基-烯"点击化学反应将半胱氨酸成功键合到修饰有乙烯基团的二氧化硅微球表面,合成了一种新型亚微米亲水作用固定相(Cys-VTMS-SiO2)。采用高压匀浆法制备了新型亚微米亲水色谱填充柱,通过不同乙腈比例、缓冲盐浓度和pH条件下对甲苯、丙烯酰胺和硫脲的分离分析揭示其亲水机理。依托加压毛细管电色谱平台,成功实现了对核苷、酚类、胺类及多肽等亲水性物质的快速有效分离,其有望应用于其他强极性和亲水性化合物的分离分析。  相似文献   

10.
A novel and convenient protocol for the preparation of an open-tubular column coated with chitosan-silica hybrid using chitosan and silane-coupling agent (γ-glycidoxy-propyltrimethoxysilane) was developed for CEC, in which, chitosan was covalently bonded to the inner wall of a fused-silica capillary using γ-glycidoxy-propyltrimethoxysilane as a cross-linking agent. The stationary phase was hydrophilic due to the chitosan-silica hybrid with abundant amine and hydroxyl functional groups. The chromatographic characteristics of the column were evaluated by the separation of some organic acids and inorganic anions. The column showed good selectivity for nucleotides, aromatic acids, and inorganic anions. The mechanism for the separation of these compounds was primarily based on the hydrophilic and electrostatic interactions combined with the electrophoretic mechanism. The CEC method on the column for the separation of these compounds was compared with CE method in a bare capillary.  相似文献   

11.
Qin F  Xie C  Yu Z  Kong L  Ye M  Zou H 《Journal of separation science》2006,29(10):1332-1343
Monolithic materials have become a well-established format for stationary phases in the field of capillary electrochromatography. Four types of monoliths, namely particle-fixed, silica-based, polymer-based, and molecularly imprinted monoliths, have been utilized as enantiomer-selective stationary phases in CEC. This review summarizes recent developments in the area of monolithic enantiomer-selective stationary phases for CEC. The preparative procedure and the characterization of these columns are highlighted. In addition, the disadvantages and limitations of different monolithic enantiomer-selective stationary phases in CEC are briefly discussed.  相似文献   

12.
Lin X  Wang J  Li L  Wang X  Lü H  Xie Z 《Journal of separation science》2007,30(17):3011-3017
A method for the separation and determination of five major opium alkaloids (narcotine, papaverine, thebaine, codeine, and morphine) in pericarpium papaveris by pressurized CEC (pCEC) with monolithic column has been developed. Under the optimum condition, linear calibration ranges of narcotine, papaverine, thebaine, codeine, and morphine were obtained as 2-85, 2-85, 5-75, 10-65, and 10-65 microg/mL, respectively. LODs of these analytes were 1.5-6.0 microg/mL. The RSD (n=7) of the migration time and peak area were 1.94-5.24 and 4.05-8.21%, respectively. The proposed method was successfully applied to the analysis of pericarpium papaveris samples. Average recoveries of 79.0-95.9% at different fortified levels of alkaloids were achieved with RSD less than 4.6%. Meanwhile, the mechanism of the separation of the alkaloids on the monolithic column was also discussed. The result showed that the separation of alkaloids was mainly based on the mixed mode of hydrophilic interaction (HI) and cation exchange.  相似文献   

13.
A monolithic stationary phase is the continuous unitary porous structure prepared by in situ polymerization or consolidation inside the column tubing and, if necessary, the surface is functionalized to convert it into a sorbent with the desired chromatographic binding properties [J. Chromatogr. A 855 (1999) 273]. Monolithic stationary phases have attracted considerable attention in liquid chromatography and capillary electrochromatography in recent years due to their simple preparation procedure, unique properties and excellent performance, especially for separation of biopolymers. This review summarizes the preparation, characterization and applications of the monolithic stationary phases. In addition, the disadvantages and limitations of the monolithic stationary phases are also briefly discussed.  相似文献   

14.
A novel monolithic stationary phase with mixed mode of hydrophilic and strong anion exchange (SAX) interactions based on in situ copolymerization of pentaerythritol triacrylate (PETA), N,N‐dimethyl‐N‐methacryloxyethyl N‐(3‐sulfopropyl) ammonium betaine (DMMSA) and a selected quaternary amine acrylic monomer was designed as a multifunctional separation column for CEC. Although the zwitterionic functionalities of DMMSA and hydroxy groups of PETA on the surface of the monolithic stationary phase functioned as the hydrophilic interaction (HI) sites, the quaternary amine acrylic monomer was introduced to control the magnitude of the EOF and provide the SAX sites at the same time. Three different quaternary amine acrylic monomers were tested to achieve maximum EOF velocity and highest plate count. The fabrication of the zwitterionic monolith (designated as HI and SAX stationary phase) was carried out when [2‐(acryloyloxy)ethyl]trimethylammonium methylsulfate was used as the quaternary amine acrylic monomer. The separation mechanism of the monolithic column was discussed in detail. For charged analytes, a mixed mode of HI and SAX was observed by studying the influence of mobile phase pH and salt concentration on their retentions on the poly(PETA‐co‐DMMSA‐co‐[2‐(acryloyloxy)ethyl]trimethylammonium methylsulfate) monolithic column. The optimized monolith showed good separation performance for a range of polar analytes including nucleotides, nucleic acid bases and nucleosides, phenols, estrogens and small peptides. The column efficiencies greater than 192 000 theoretical plates/m for estriol and 135 000 theoretical plates/m for charged cytidine were obtained.  相似文献   

15.
黄桂华  陈思谨  林旭聪  谢增鸿 《色谱》2010,28(12):1173-1178
以2-羟基乙基甲基丙烯酸酯(HEMA)为单体,乙二醇二甲基丙烯酸酯(EDMA)为交联剂,制备了亲水分离模式的聚HEMA-co-EDMA新型毛细管电色谱(CEC)整体柱。考察了整体柱的结构特征及其CEC性能,研究了极性物质的保留行为,并对其可能的保留机理进行了探讨。所制备的整体柱稳定性好,固定相表面带有极性羟基功能团,不仅能提供亲水相互作用位点,且能吸附流动相中的阴离子产生阳极电渗流(EOF)。在流动相中乙腈含量较高(>62%,体积分数)的条件下,整体柱表现出典型的亲水作用,实现了对核苷、碱基和苯胺类带有碱性的强极性化合物的高效分离,并成功分离了苯酚类、苯甲酸类等中性或酸性的极性化合物。  相似文献   

16.
Chen JL 《Electrophoresis》2006,27(4):729-735
A synthetic coppermesogenic polymer is prepared and then covalently bonded to the siloxane-based deactivated column as the stationary phases of open-tubular CEC with essentially high phase ratio. The EOF generated from the modified phase is surveyed through conventional aqueous buffers and hydroorganic mobile phases. Zeta potentials, which are computed from the EOF data and the ratio of dielectric constant to viscosity, are plotted as a function of pH, ionic molarity, and compositional range. These plots responsible for the electroosmotic characteristic of the bonded phases are found to be like those of bare fused-silica or deactivated columns through decreasing or increasing the ACN content in the mobile phase, respectively. This two-phase characteristic is basically derived from the polymeric configuration with carboxylato ligands attached onto the polysiloxane backbone. Phthalates and amino acids are suitable probes to examine the two phenomena, more-polar and less-polar mediums, respectively, and to judge whether the chromatographic retention is the major source of separation mechanism. With the mixing modes of Lewis acid-base interaction, dispersive force, and shape discrimination, the chromatographic partition adequately accomplishes the uneasily resolved separations by only CZE mode, although the electrophoretic migration is truly somewhat involved.  相似文献   

17.
Several chiral drugs, promethazine, carteolol, celiprolol, and albuterol, were resolved with vancomycin as the chiral stationary phase by pressurized capillary electrochromatography (pressurized CEC) and capillary HPLC. The effects of pressure and electrical field strength on efficiency, resolution, and capacity factor in pressurized CEC were investigated. A mathematical model describing the relationship of capacity factor in pressurized CEC with voltage, pressurized flow velocity, electroosmotic mobility, and electrophoretic mobility was established, which was in good agreement with the experimental data.  相似文献   

18.
A 2-D separation platform was constructed using micro strong cation-exchange liquid chromatography (μ-SCXLC) and reversed-phase pressurized capillary electrochromatography (RP-pCEC) for the analysis of complex samples. Samples were fractionated by the first-dimension μ-SCXLC with a linear solvent gradient and then injected into the second-dimension RP-pCEC for further separation. The μ-SCXLC/RP-pCEC 2-D system with three separation mechanisms, namely strong cation-exchange, reversed-phase chromatography and electrophoresis, provided high selectivity, high resolution and high peak capacity compared to one-dimensional chromatographic approaches. Separation effectiveness of this 2-D system was demonstrated by the analysis of different kinds of complex samples, such as traditional Chinese medicine Cortex Phellodendri, bovine serum albumin (BSA) tryptic digest and real serum tryptic digest. A theoretical peak capacity of approximately 1200 was achieved, which proves its promising potential for the separation and analysis of complex samples.  相似文献   

19.
李新燕  王彦  谷雪  陈妍  阎超 《色谱》2010,28(3):231-235
以甲基丙烯酸丁酯(BMA)和3-[N,N-二甲基-[2-(2-甲基丙-2-烯酰氧基)乙基]铵]丙烷-1-磺酸内盐(SPE)为单体,制备了新型的亲水作用毛细管整体柱,并通过三聚氰胺在此柱上的保留行为证明其具有亲水性。以加压毛细管电色谱(pCEC)技术为平台,优化了整体柱基于亲水作用分离分析奶制品中三聚氰胺的色谱条件。当流动相中乙腈与10 mmol/L磷酸盐缓冲液的体积比为80:20, pH为3.0,电压为3 kV,检测波长为215 nm时,三聚氰胺能获得很好的分离。方法学考察结果表明,合成的亲水整体柱具有良好的重现性和渗透性,建立的pCEC分析方法的检出限为0.05 mg/L。该方法简单方便,回收率较高,而且流动相中无需添加离子对试剂,适合于奶制品中三聚氰胺的定量测定。  相似文献   

20.
A monolithic capillary column with a mixed‐mode stationary phase of reversed‐phase/hydrophilic interaction chromatography was prepared for capillary liquid chromatography. The monolith was created by an in‐situ copolymerization of a homemade monomer N,N‐dimethyl‐N‐acryloxyundecyl‐N‐(3‐sulfopropyl) ammonium betaine and a crosslinker pentaerythritol triacrylate in a binary porogen agent consisting of methanol and isopropanol. The functional monomer was designed to have a highly polar zwitterionic sulfobetaine terminal group and a hydrophobic long alkyl chain moiety. The composition of the polymerization solution was systematically optimized to permit the best column performance. The columns were evaluated by using acidic, basic, polar neutral analytes, as well as a set of alkylbenzenes and Triton X100. Very good separations were obtained on the column with the mixed‐mode stationary phase. It was demonstrated that the mixed‐mode stationary phase displayed typic dual retention mechanisms of reversed‐phase/hydrophilic interaction liquid chromatography depending on the content of acetonitrile in the mobile phase. The method for column preparation is reproducible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号