首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Gezici O  Kara H 《Talanta》2011,85(5):2405-2410
In the present study, metal binding property of humic acid (HA) was successfully adapted to the ligand-exchange concept, and metal-loaded immobilized humic acid was used as a ligand exchanger stationary phase for separation of some nucleosides. Humic-acid bonded aminopropyl silica (EC-HA-APS) was turned into ligand exchanger forms by loading aqueous solutions of Cu2+, and Co2+ to the column (4.6 × 150; as mm) packed with EC-HA-APS. Metal ion solutions were loaded to the column in a stepwise manner where the concentration of metal ion solution being loaded to the column was increased gradually between 5 and 100 mM. The progress of metal loading process was monitored via the breakthrough curves propagated stepwise. Ligand-exchange chromatography (LEC) studies were performed on an HPLC system, and chromatographic behaviors of the studied nucleosides (i.e. uridine, Urd; thymidine, Tyd; cytidine, Cyd; adenosine, Ado; and guanosine, Guo) were investigated on Cu2+ and Co2+ loaded forms of the EC-HA-APS (Cu-EC-HA-APS and Co-EC-HA-APS). Effect of mobile phase composition, temperature, and the type of metal ion loaded to the column on the retentive behaviors of the compounds was studied, in detail. The studied solutes exhibited mixed-mode RPLC/LEC behavior on the stationary phase. Metal-loaded column (M-EC-HA-APS) was easily regenerated into its original form, EC-HA-APS, with 98 ± 2% metal recoveries, by using aqueous mixture of EDTA + NH3 at pH = 7.5. Thus, the stationary phase exhibited a high flexibility between RPLC and LEC modes. This property, also, made it possible to convert the stationary phase into various ligand exchanger forms by loading different metal ions. Hence, capacity and selectivity of the stationary phase towards the studied species was manipulated easily by loading different metal ions to the stationary phase. Baseline separation for the studied species was achieved on Cu-EC-HA-APS and Co-EC-HA-APS and some differentiations were observed in capacity and selectivity, depending on the type of metal loaded. Thus, being as the first endeavor on usability of immobilized HA as a ligand exchanger stationary phase, the present study is believed to be useful to understand multifunctional character of HA-based solid/stationary phases.  相似文献   

2.
Singh P  Rawat JP  Rahman N 《Talanta》2003,59(3):443-452
Samples of zirconium(IV) iodovanadate have been synthesized under varying mixing ratios by adding a mixture of aqueous solution of 0.1 M potassium iodate and 0.1 M sodium metavanadate to aqueous solution of 0.1 M zirconium oxychloride at pH 1. The ion exchange capacity of the material for Na+ ion was found to be 2.20 meq g−1 of dry exchanger. The material has been characterized on the basis of chemical composition, FTIR and TGA. The chemical stability of the product has been checked in neutral, acidic and basic media. The product has been used as electron exchanger. The oxidation of Fe(II), Sn(II), ascorbic acid and thioglycolic acid was achieved by batch-equilibrium technique successfully. The maximum redox capacity of the exchanger has been found to be 4.20 meq g−1 of exchanger by column process.  相似文献   

3.
B. Rezaei  R. Khademi 《Talanta》2009,79(3):669-675
Application of electrospray ionization ion mobility spectrometry (ESI-IMS) as the detection technique for separation method based on molecular imprinted polymer (MIP) was investigated and evaluated. The method is exhaustively validated, including sensitivity, selectivity, recovery, reproducibility, and column capacity. The linear dynamic range of 0.02-2.00 μg mL−1 was obtained for primidone analysis with ESI-IMS. The recovery of drug analyzed was calculated to be above 90% and the relative standard deviation (RSD), was below 3% for all experiments. Various real samples were analyzed with the coupled techniques, and the results obtained revealed the efficient clean-up of the samples using MIP separation before the analysis by ESI-IMS as a detection technique.  相似文献   

4.
A simple, sensitive and selective method for the simultaneous determination of nitrite and nitrate in water samples has been developed. The method is based on ion-exchange separation, online photochemical reaction, and luminol chemiluminescence detection. The separation of nitrite and nitrate was achieved using an anion-exchange column with a 20 mM borate buffer (pH 10.0). After the separation, these ions were converted to peroxynitrite by online UV irradiation using a low-pressure mercury lamp and then mixed with a luminol solution prepared with carbonate buffer (pH 10.0). The calibration graphs of the nitrite and nitrate were linear in the range from 2.0 × 10−9 to 2.5 × 10−6 M and 2.0 × 10−8 to 2.5 × 10−5 M, respectively. Since the sensitivity of nitrite was about 10 times higher than that of nitrate, the simultaneous determination of nitrite and nitrate in the water samples could be efficiently achieved. This method was successfully applied to various water samples – river water, pond water, rain water, commercial mineral water, and tap water – with only filtration and dilution steps.  相似文献   

5.
In this work, a new, simple and sensitive flow injection catalytic kinetic spectrophotometric determination of nitrite is reported based on catalytic effect of nitrite on the redox reaction between sulfonazo III and potassium bromate in acidic media. The reaction was monitored by measuring the decrease in the absorbance of sulfunazo III at 570 nm. Various chemical (such as the effect of acidity, reagents concentrations) and instrumental parameters (flow rate, reaction coil length, injection volume and temperature) were studied and were optimized. Under the optimum conditions calibration graph was linear in the nitrite concentration ranges of 8.00 × 10−3-3.00 × 10−1 μg/ml (with slope of 2.40) and 3.50 × 10−1-1.80 μg/ml (with slope of 0.42). The detection limit was 6.00 × 10−3 μg/ml of nitrite, the relative standard deviation (n = 10) was 1.25% and 0.88% for 5.00 × 10−2 and 2.00 × 10−1 μg/ml of nitrite respectively. About 60 samples in 1 h can be analyzed. The interfering effects of various chemical species were studied. The method was successfully applied in the determination of nitrite in food and environmental samples.  相似文献   

6.
7.
In this work, it was developed a method for the determination of nitrite and nitrate in groundwater by high-resolution continuum source electrothermal molecular absorption spectrometry of NO produced by thermal decomposition of nitrate in a graphite furnace. The NO line at 215.360 nm was used for all analytical measurements and the signal obtained by integrated absorbance of three pixels. A volume of 20 μL of standard solution or groundwater sample was injected into graphite furnace and 5 μL of a 1% (m/v) Ca solution was co-injected as chemical modifier. The pyrolisis and vaporization temperatures established were of 150 and 1300 °C, respectively. Under these conditions, it was observed a difference of thermal stability among the two nitrogen species in the presence of hydrochloric acid co-injected. While that the nitrite signal was totally suppressed, nitrate signal remained nearly stable. This way, nitrogen can be quantified only as nitrate. The addition of hydrogen peroxide provided the oxidation of nitrite to nitrate, which allowed the total quantification of the species and nitrite obtained by difference. A volume of 5 μL of 0.3% (v/v) hydrochloric acid was co-injected for the elimination of nitrite, whereas that hydrogen peroxide in the concentration of 0.75% (v/v) was added to samples or standards for the oxidation of nitrite to nitrate. Analytical curve was established using standard solution of nitrate. The method described has limits of detection and quantification of 0.10 and 0.33 μg mL−1 of nitrogen, respectively. The precision, estimated as relative standard deviation (RSD), was of 7.5 and 3.8% (n = 10) for groundwater samples containing nitrate–N concentrations of 1.9 and 15.2 μg mL−1, respectively. The proposed method was applied to the analysis of 10 groundwater samples and the results were compared with those obtained by ion chromatography method. In all samples analyzed, the concentration of nitrite–N was always below of the limit of quantification of both the methods. The concentrations of nitrate–N varied from 0.58 to 15.5 μg mL−1. No significant difference it was observed between the results obtained by both methods for nitrate–N, at the 95% confidence level.  相似文献   

8.
A pyrimethanil-imprinted polymer (P1) was prepared by iniferter-mediated photografting a mixture of methacrylic acid and ethylene dimethacrylate onto homemade near-monodispersed chloromethylated polydivinylbenzene beads. The chromatographic behaviour of a column packed with these imprinted beads was compared with another column packed with irregular particles obtained by grinding a bulk pyrimethanil-imprinted polymer (P2). The comparison was made using the kinetic model of non-linear chromatography, studying the elution of the template and of two related substances, cyprodinil and mepanipyrim. Extension of the region of linearity, capacity factors for the template and the related substances, column selectivity, binding site heterogeneity, apparent affinity constant (K) and lumped kinetic association (ka) and dissociation rate constant (kd) were studied during a large interval of solute concentration, ranging between 1 and 2000 μg/ml. From the experimental results obtained, in the linearity region of solute concentration column selectivity and binding site heterogeneity remained essentially the same for the two columns, while column capacity (at 20 μg/ml, P1 = 23.1, P2 = 11.5), K (at 20 μg/ml, P1 = 8.3 × 106 M−1, P2 = 2.5 × 106 M−1) and ka (at 20 μg/ml, P1 = 3.5 μM−1 s−1, P2 = 0.47 μM−1 s−1) significantly increased and kd (at 20 μg/ml, P1 = 0.42 s−1, P2 = 0.67 s−1) decreased for the column packed with the imprinted beads. These results are consistent with an influence of the polymerisation method on the morphology of the resulting polymer and not on the molecular recognition properties due to the molecular imprinting process.  相似文献   

9.
Mercury-pyrrolidinedithiocarbamate complexes are first time used for speciation of aquatic mercury with high-performance liquid chromatographic/ion trap-mass spectrometric method utilizing atmospheric pressure chemical ionization (APCI). The separation of the four mercury species was achieved in less than 5 min with a linear gradient profile of aqueous methanol from 70 up to 100% (v/v) in 4th min, isocratic elution at 100% up to 5th min and followed by a negative gradient to 70% in 6th min. The best separation was achieved on a reverse phase Zorbax Eclipse XDB C18 column (50 mm × 2.1 mm i.d., 1.8 μm particle size). The on-column limits of detection (injection volume 1 μL) were 370 pg for methylmercury (MeHg+), 280 pg for ethylmercury (EtHg+), 250 pg for phenylmercury (PhHg+) and 90 pg for inorganic mercury (Hg2+) when the data were collected in selective ion monitoring (SIM) mode. A method of isolation and preconcentration of the mercury species using a “home-made” C18 solid phase extraction (SPE) microcolumns was developed to enhance sensitivity of the method. The preconcentration factor as much as 2500 was achieved with on-column complex formation of mercury-pyrrolidinedithiocarbamate. Methanol (100%) was chosen for elution of preconcentrated mercury species. The method was applied for the determination of mercury species in river water samples.  相似文献   

10.
The sorption behaviour of 2.5 × 10−5 M solution of Cd(II) on polyurethane foam (PUF) from iodide medium have been investigated. The conditions were optimized from aqueous solutions of different pH (1-10) and of acids of varied concentration (0.01-1.0 M). The maximum concentration of KI was found to be 0.24 M and equilibration time was established to be 20 min. The data successfully followed the Freundlich and Dubinin-Radushkevich (D-R) isotherms at low metal ion concentration while Langmuir isotherm followed at higher metal ion concentration. The Freundlich parameter 1/n = 0.66 ± 0.02 have been evaluated whereas D-R isotherm yields the sorption free energy E = 10.5 ± 0.1 kJ mol−1 indicating ion exchange type chemisorption. The monolayer coverage (XL) constant of Langmuir isotherm was found to be 23.7 ± 0.4 mg g−1. The numerical values of thermodynamics parameters enthalpy (ΔH), entropy (ΔS) and Gibbs free energy (ΔG) indicated the endothermic and spontaneous nature of sorption. The Scatchard plot analysis was tested to evaluate the binding sites of the PUF and stability constants of sorption were determined. On the basis of these parameters, the sorption mechanism was discussed. Among the foreign ions tested, Pb(II), Hg(II), cyanide and nitrite should be absent. The clean separation of Cd(II) from Zn(II) ions in the ratio 1:250, respectively, was achieved by column chromatography.  相似文献   

11.
Ahmed S  Atia NN  Mohamed NA 《Talanta》2011,84(3):666-672
A simple, reproducible and efficient dual separation mode high performance liquid chromatographic (HPLC) method was developed for simultaneous determination of antihypertensive drug combinations including; hydrochlorothiazide (HCTZ), valsartan (VAL), amiloride (AML) and captopril (CAP). The newly developed Platinum™ column, which provides a dual-mode separation with its polar and non-polar sites, was used for rapid separation of these co-administered drugs. Good resolution was obtained when Platinum™ column was used compared with C18 column. Additionally, simple isocratic mode with mobile phase containing methanol and 0.02 mole L−1 phosphate buffer adjusted to pH 3.0 (45:55, v/v) was used for separation. The flow rate was 0.5 mL min−1 and effluent was monitored at 270 nm. All the investigated drugs were completely separated within less than 6 min. The linearity range obtained for the developed HPLC method was 0.5-100 μg mL−1 with detection limits of 0.13-1.2 μg mL−1 for all the studied drugs. The method was validated in accordance with the requirements of ICH guidelines and shown to be suitable for intended applications. The method was successfully used for determination of the studied drugs in pure form and pharmaceutical dosage forms without prior need for separation. The method is valuable for quality control laboratories for simultaneous determination of these co-administered antihypertensive drugs in binary, ternary and quaternary mixtures.  相似文献   

12.
In the Sequential Injection Chromatography (SIC) only monolithic columns for chromatographic separations have been used so far. This article presents the first use of fused-core particle packed column in an attempt to extend of the chromatographic capabilities of the SIC system. A new fused-core particle column (2.7 μm) Ascentis® Express C18 (Supelco™ Analytical) 30 mm × 4.6 mm brings high separation efficiency within flow rates and pressures comparable to monolithic column Chromolith® Performance RP-18e 100-3 (Merck®) 100 mm × 3 mm. Both columns matches the conditions of the commercially produced SIC system - SIChrom™ (8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with 4 mL reservoir - maximal work pressure 1000 PSI) (FIAlab®, USA). The system was tested by the separation of four estrogens with similar structure and an internal standard - ethylparaben. The mobile phase composed of acetonitrile/water (40/60 (v/v)) was pumped isocratic at flow rate 0.48 mL min−1. Spectrophotometric detection was performed at wavelength of 225 nm and injected volume of sample solutions was 10 μL. The chromatographic characteristics of both columns were compared. Obtained results and conclusions have shown that both fused-core particle column and longer narrow shaped monolithic column bring benefits into the SIC method.  相似文献   

13.
Filik H  Giray D  Ceylan B  Apak R 《Talanta》2011,85(4):1818-1824
A novel fiber optic spectrophotometric method for nitrite determination in different samples is suggested, based on the reaction of nitrite with Safranin O in acidic medium to form a diazo-safranin, which is subsequently coupled with pyrogallol in alkaline medium to form a highly stable, red azo dye, followed by cloud point extraction (CPE) using a mixed micelle of a nonionic surfactant, Triton X-114, with an anionic surfactant, sodium dodecyl sulphate (SDS). The reaction and extraction conditions (e.g., acidity for diazotization and alkalinity for pyrogallol coupling, and other reagent concentrations, time, and tolerance to other ions) were optimized. Linearity was obeyed in a concentration range up to 230 μg L−1, and the detection limit of the method is 0.5 μg L−1 of nitrite ion. The molar absorptivity for nitrite of the Safranin-diazonium salt (?610 nm = 4 × 103 L mol−1 cm−1) existing in literature was greatly enhanced by pyrogallol coupling and CPE enrichment (?592 nm = 1.39 × 105 L mol−1 cm−1). The method was applied to the determination of nitrite in tap water, lake water and milk samples with an optimal preconcentration factor of 20.  相似文献   

14.
The development of a highly sensitive amperometric sensor for nitrite using a glassy carbon electrode modified with alternated layers of iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin (FeT4MPyP) and cobalt(II) tetrasulfonated phthalocyanine (CoTSPc) is described. The modified electrode showed an excellent catalytic activity and stability for the nitrite oxidation decreasing the peak potentials about 200 mV toward less positive values and presenting much higher peak currents than those obtained on the bare GC electrode. A linear response range of 0.2-8.6 μmol l−1, with a sensitivity of 0.37 μA l μmol−1 and detection limit of 0.04 μmol l−1 were obtained with this sensor. The repeatability of the proposed sensor, evaluated in term of relative standard deviation, was verified to be 1.4% for 10 measurements of 0.2 μmol l−1 nitrite solution. Interference caused by common ions has been investigated in simulated mixtures containing high concentration level of interfering ions and the sensor was found to be tolerant against these ions. The developed sensor was applied for the nitrite determination in water samples and the results were in agreement with those obtained by a comparative method described in the literature. The average recovery for these samples was 100.1 (±0.7)%.  相似文献   

15.
Anion-exchange (AEX) columns were prepared by on-column polymerization of acrylates and methacrylates containing tertiary amino or quaternary ammonium groups on monolithic silica in a fused silica capillary modified with anchor groups. The columns provided a plate height (H) of less than 10 μm at optimum linear velocity (u) with keeping their high permeability (K = 9–12 × 10−14 m2). Among seven kinds of AEX columns, a monolithic silica column modified with poly(2-hydroxy-3-(4-methylpiperazin-1-yl)propyl methacrylates) (HMPMA) showed larger retentions and better selectivities for nucleotides and inorganic anions than the others. The HMPMA column of 410 mm length produced 42 000–55 000 theoretical plates (N) at a linear velocity of 0.97 mm/s with a backpressure of 3.8 MPa. The same column could be employed for a fast separation of inorganic anions in 1.8 min at a linear velocity of 5.3 mm/s with a backpressure of 20 MPa. In terms of van Deemter plot and separation impedance, the HMPMA column showed higher performance than a conventional particle-packed AEX column. The HMPMA column showed good recovery of a protein, trypsin inhibitor, and it was applied to the separation of proteins and tryptic digest of bovine serum albumin (BSA) in a gradient elution, to provide better separation compared to a conventional particle-packed AEX column.  相似文献   

16.
The feasibility of a microcolumn electrophoresis technique was investigated with a 100 mm length, 2 mm I.D. fused-silica microcolumn packed with uniform quartz microncrystals prepared by hydrothermal synthesis. To evaluate the separation technique, tryptophan, phenylalanine and tyrosine were primarily separated by the microcolumn electrophoresis and detected at 216 nm without derivatization by an ordinary spectrophotometer. The separation conditions of the amino acids were optimized. With 1.5 mmol/L disodium phosphate buffer solution (pH 11.5) containing 25% (v/v) methanol and 10% (v/v) acetonitrile, the three amino acids were separated and the separation efficiency of tryptophan was 4.5 × 104 plates/m. The limits of detection were 0.035, 0.22 and 0.20 μmol/L, respectively. The sample capacity of the electrophoretic microcolumn achieved 35 μL. The proposed method was used to determine these amino acids in compound amino acid injection samples without derivatization. For the simplicity and portability of the microcolumn electrophoresis, it is studied as one of the high-performance separation techniques for an in situ and real-time electrokinetic flow analysis system. For its high detection sensitivity and large sample capacity, it can be developed for preparative electrophoresis.  相似文献   

17.
The paper describes a research of possible application of UTEVA and TRU resins and anion exchanger AMBERLITE CG-400 in nitrate form for the isolation of uranium and thorium from natural samples. The results of determination of distribution coefficient have shown that uranium and thorium bind on TRU and UTEVA resins from the solutions of nitric and hydrochloric acids, and binding strength increases proportionally to increase the concentration of acids. Uranium and thorium bind rather strongly to TRU resin from the nitric acid in concentration ranging from 0.5 to 5 mol L−1, while large quantities of other ions present in the sample do not influence on the binding strength. Due to the difference in binding strength in HCl and HNO3 respectively, uranium and thorium can be easily separated from each other on the columns filled with TRU resin. Furthermore, thorium binds to anion exchanger in nitrate form from alcohol solutions of nitric acid very strongly, while uranium does not, so they can be easily separated. Based on these results, we have created the procedures of preconcentration and separation of uranium and thorium from the soil, drinking water and seawater samples by using TRU and UTEVA resins and strong base anion exchangers in nitrate form. In one of the procedures, uranium and thorium bind directly from the samples of drinking water and seawater on the column filled with TRU resin from 0.5 mol L−1 HNO3 in a water sample. After binding, thorium is separated from uranium with 0.5 mol L−1 HCl, and uranium is eluted with deionised water. By applying the described procedure, it is possible to achieve the concentration factor of over 1000 for the column filled with 1 g of resin and splashed with 2 L of the sample. Spectrophotometric determination with Arsenazo III, with this concentration factor results in detection limits below 1 μg L−1 for uranium and thorium. In the second procedure, uranium and thorium are isolated from the soil samples with TRU resin, while they are separated from each other on the column filled with anion exchanger in alcohol solutions. Anion exchanger combined with alcohol solutions enables isolation of thorium from soil samples and its separation from a wide range of elements, as well as spectrophotometric determination, ICP-MS determination, and other determination techniques.  相似文献   

18.
An experimental study was performed to investigate the effects of column parameters and gradient conditions on the separation of intact proteins using styrene-based monolithic columns. The effect of flow rate on peak width was investigated at constant gradient steepness by normalizing the gradient time for the column hold-up time. When operating the column at a temperature of 60 °C a small C-term effect was observed in a flow rate range of 1–4 μL/min. However, the C-term effect on peak width is not as strong as the decrease in peak width due to increasing flow rate. The peak capacity increased according to the square root of the column length. Decreasing the macropore size of the polymer monolith while maintaining the column length constant, resulted in an increase in peak capacity. A trade-off between peak capacity and total analysis time was made for 50, 100, and 250 mm long monolithic columns and a microparticulate column packed with 5 μm porous silica particles while operating at a flow rate of 2 μL/min. The peak capacity per unit time of the 50 mm long monolithic column with small pore size was superior when the total analysis time is below 120 min, yielding a maximum peak capacity of 380. For more demanding separations the 250 mm long monolith provided the highest peak capacity in the shortest possible time frame.  相似文献   

19.
A selective method has been developed for the extraction chromatographic trace level separation of Cu(II) with Versatic 10 (liquid cation exchanger) coated on silanised silica gel (SSG-V10). Cu(II) has been extracted from 0.1 M acetate buffer at the range of pH 4.0–5.5. The effects of foreign ions, pH, flow-rate, stripping agents on extraction and elution have been investigated. Exchange capacity of the prepared exchanger at different temperatures with respect to Cu(II) has been determined. The extraction equilibrium constant (Kex) and different standard thermodynamic parameters have also been calculated by temperature variation method. Positive value of ΔH (7.98 kJ mol−1) and ΔS (0.1916 kJ mol−1) and negative value of ΔG (−49.16 kJ mol−1) indicated that the process was endothermic, entropy gaining and spontaneous. Preconcentration factor was optimized at 74.7 ± 0.2 and the desorption constants Kdesorption1(1.4 × 10−2) and Kdesorption2(9.8 × 10−2) were determined. The effect of pH on Rf values in ion exchange paper chromatography has been investigated. In order to investigate the sorption isotherm, two equilibrium models, the Freundlich and Langmuir isotherms, were analyzed. Cu(II) has been separated from synthetic binary and multi-component mixtures containing various metal ions associated with it in ores and alloy samples. The method effectively permits sequential separation of Cu(II) from synthetic quaternary mixture containing its congeners Bi(III), Sn(II), Hg(II) and Cu(II), Cd(II), Pb(II) of same analytical group. The method was found effective for the selective detection, removal and recovery of Cu(II) from industrial waste and standard alloy samples following its preconcentration on the column. A plausible mechanism for the extraction of Cu(II) has been suggested.  相似文献   

20.
Zuo Y  Wang C  Van T 《Talanta》2006,70(2):281-285
A simple, fast, sensitive and accurate reversed-phase ion-pair HPLC method for simultaneous determination of nitrite and nitrate in atmospheric liquids and lake waters has been developed. Separations were accomplished in less than 10 min using a reversed-phase C18 column (150 mm × 2.00 mm i.d., 5 μm particle size) with a mobile phase containing 83% 3.0 mM ion-interaction reagent tetrabutylammonium hydroxide (TBA-OH) and 2.0 mM sodium phosphate buffer at pH 3.9 and 17% acetonitrile (flow rate, 0.4 mL/min). UV light absorption responses at 205 nm were linear over a wide concentration range from 100 μg/mL to the detection limits of 10 μg/L for nitrite and 5 μg/L nitrate. Quantitation was carried out by the peak area method. The relative standard deviation for the analysis of nitrite and nitrate was less than 3.0%. This method was applied for the simultaneous determination of nitrite and nitrate in dew, rain, snow and lake water samples collected in southeast Massachusetts. Nitrate was found being present at 4.79-5.99 μg/mL in dew, 1.20-2.63 μg/mL in rain, 0.32-0.60 μg/mL in snow and 0.12-0.23 μg/mL in lake water. Nitrite was only a minor species in dew (0.62-0.83 μg/mL), rain (<0.005-0.14 μg/mL), snow (0.021-0.032 μg/mL) and lake water (0.12-0.16 μg/mL). High levels of nitrite and nitrate observed in dew water droplets may constitute an important source of hydroxyl radicals in the sunny early morning.  相似文献   