首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Within the framework of an international benchmark test, the Soret coefficient S T , the thermodiffusion coefficient D T , and the isothermal mass diffusion coefficient D of the three binary systems formed with dodecane, isobutylbenzene and 1,2,3,4-tetrahydronaphthalene (with a mass fraction of 0.5 in each component at a temperature of 25C) have been measured. Convective coupling in thermogravitational columns has been used to determine D T based on the Furry-Jones-Onsager theory and the so-called open-ended capillary technique for D . The ratio of D T to D , obtained in these two independent experiments, provides the Soret coefficient. In one case, we were able to use laser Doppler velocimetry to measure the modifications of the velocity amplitude due to thermodiffusion, which is also a way to obtain the Soret coefficient. Our results for these three coefficients are in good agreement with those obtained by other benchmark tests.  相似文献   

2.
Gerhard Wittko  Werner Köhler 《哲学杂志》2013,93(17-18):1973-1987

Within the framework of an international benchmark test, the Soret coefficient S T , thermal diffusion coefficient D T and mutual mass diffusion coefficient D of the three binary mixtures of dodecane, isobutylbenzene and 1,2,3,4-tetrahydronaphthalene with a concentration of 50 wt% of each component at a temperature of 25C have been measured with a holographic grating technique. For the analysis of the experimental data a new numerical correction algorithm based on linear response theory has been employed. The corrections applied are on the order of 1% for S T and 5% for D . The coefficients S T , D and D T are determined with relative errors of a few per cent.  相似文献   

3.

Within the framework of an international benchmark test, the thermodiffusion coefficients D T of the three binary systems formed with dodecane, isobutylbenzene and 1,2,3,4-tetrahydronaphthalene (with a mass fraction of 0.5 for each component at a temperature of 25C) have been measured. Convective coupling in cylindrical thermogravitational columns has been used to determine D T based on the Furry-Jones-Onsager theory. For each system, several columns with different gaps and heights were employed. Our results for these three coefficients are in good agreement with those obtained by other benchmark tests; the maximum deviation from the proposed benchmark values is 8.5%, which is not too bad owing to the difficulties of measuring a thermodiffusion coefficient.  相似文献   

4.

With the aim of providing reliable benchmark values, we have measured the Soret, diffusion and thermal diffusion coefficients of the three binary mixtures of dodecane, isobutylbenzene and 1,2,3,4 tetrahydronaphthalene for a concentration of 50 wt% at a temperature of 25C. The experimental techniques applied by the five participating laboratories are transient holographic gratings, annular and parallelepipedic thermogravitational columns, and vertical parallelepipedic columns with velocity amplitude determination by laser doppler velocimetry. The systems have also been studied in a annular thermogravitational column filled with a porous medium in the gap. There is a good agreement between the different experiments with deviations of the order of a few per cent in most cases (8.5% at most). The numerical values are tabulated in the paper.  相似文献   

5.
A. Königer  B. Meier 《哲学杂志》2013,93(10):907-923
We have measured the Soret (S T ), diffusion (D), and thermal diffusion (D T ) coefficients of three binary mixtures of dodecane (DD), isobutylbenzene (IB) and 1,2,3,4-tetrahydronaphthalene (TH) for a concentration of 50 wt% at a temperature of 25°C by means of an optical beam deflection cell. This relevant experimental technique was still missing from a recent benchmark campaign for the measurement of the Soret effect. The measured coefficients agree to within a few percent (10% for S T , D of TH/IB) with the proposed benchmark values. A detailed analysis of the measurement process of the beam deflection cell, which allows for an elegant extension to include temperature gradients within the windows, is given, and improved benchmark values are suggested. In addition, ethanol–water mixtures have been investigated very carefully over a broad concentration and temperature range. Comparison with data of Kolodner and Wiegand gives a generally good agreement with some systematic deviations. Contrary to theoretical predictions, we have not been able to identify a second sign change of S T at high ethanol concentrations.  相似文献   

6.

Argon has been widely used as a diluent for high-temperature reacting flow experiments. Numerical simulation of such process requires accurate diffusion coefficients for the H–Ar pair. All available potential energy functions for the H–Ar system have been empirically extrapolated in the repulsive region and are probably not reliable for prediction of H–Ar binary diffusion coefficient at high temperatures. We perform calculations using the restricted coupled cluster theory with single and double excitation (plus triple corrections) [RCCSD(T)] and suitable basis sets to obtain accurate potential energies. The calculated potential energy function is corrected for basis set superposition error and is validated against molecular beam scattering data. Comparisons with previous literature potential functions are also made. Using the Chapman–Enskog theory we carried out first-principle calculation of high-temperature diffusion coefficients by direct numerical integration of the collision integrals using the RCCSD(T) potential function. The computed diffusion coefficients are validated against available experimental data. Comparisons are also made with results obtained from transport compilations and packages commonly used in combustion simulation.  相似文献   

7.
A variational method is used to obtain estimates of the effective particle transport coefficients in a random static magnetic field. The particle propagation is described by an anisotropic diffusion equation. The diffusion coefficient parallel to the local magnetic field is much greater than the transverse diffusion coefficient. For large-scale magnetic-field variations the diffusion is described by effective coefficients. The variational approach can be used to find the effective parallel and perpendicular diffusion coefficients. It was shown that the instability growth rate of the magnetic field lines determines the upper estimate of the effective transverse diffusion coefficient. Zh. éksp. Teor. Fiz. 114, 398–405 (August 1998)  相似文献   

8.
The diffusion of 18O in α-Hf was studied in the 723–923 K temperature range by using ion implantation and nuclear resonance techniques. The measurements show that the diffusion coefficients follows an Arrhenius behavior D(T)=D0e(-Q/RT), where D0=(5±3)×10-9 m2s-1 and Q=162±5 kJ/mol. A comparison of the present results with previous ones is also done. PACS 66:30 Jt; 85:40 Ry  相似文献   

9.
PurposeThis study sought to monitor the dynamic process of lymph node (LN) metastasis with intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI), and to investigate the impact of disease course on the detection of metastatic LNs by IVIM-DWI.MethodsTwenty female New Zealand rabbits with 2.5–3.0 kg body weight were studied. VX2 cells and egg yolk emulsion were randomly inoculated into one thigh to induce metastatic and inflammatory popliteal LNs, respectively. Eight rabbits underwent IVIM-DWI (14 b values, 0–2000 s/mm2) 2 h prior to, and 14, 21, and 28 days after inoculation (D0, D14, D21, D28). The apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) were measured and compared between the metastatic and the inflammatory groups at each time point. Three rabbits randomly chosen from the remaining twelve rabbits were sacrificed at each time point to perform hematoxylin and eosin staining and histologic evaluation.ResultsThe patterns of dynamic change of D*, ADC, and D were different between the metastatic and the inflammatory LNs. The metastatic group had a lower D* value at D14 (p = .003), and greater ADC and D values at both D21 (p = .001, p = .001) and D28 (p = .021, p = .001), compared to the inflammatory group. The f value of the metastatic group was greater than that of the inflammatory only at D28 (p = .001).ConclusionsIVIM-DWI can reflect the dynamic process of LN metastasis, and disease course has a significant influence on the ability of IVIM-DWI to detect metastatic nodes.  相似文献   

10.
Ignition delay times and OH concentration time-histories were measured during n-dodecane oxidation behind reflected shocks waves using a heated, high-pressure shock tube. Measurements were made over temperatures of 727-1422 K, pressures of 15-34 atm, and equivalence ratios of 0.5 and 1.0. Ignition delay times were measured using side-wall pressure and OH emission diagnostics, and OH concentration time-histories were measured using narrow-linewidth ring-dye laser absorption near the R-branchhead of the OH A-X (0, 0) system at 306.47 nm. Shock tube measurements were compared to model predictions of four current n-dodecane oxidation detailed mechanisms, and the differences, particularly in the low-temperature negative-temperature-coefficient (NTC) region where the influence of non-ideal facility effects can be significant, are discussed. To our knowledge, the current measurements provide the first gas-phase shock tube ignition delay times (at pressures above 13 atm) and quantitative OH concentration time-histories for n-dodecane oxidation under practical engine conditions, and hence provide benchmark validation targets for refinement of jet fuel detailed kinetic modeling, since n-dodecane is widely used as the principal representative for n-alkanes in jet fuel surrogates.  相似文献   

11.
A parametric method for spatially resolved measurements for velocity autocorrelation functions, R(u)(tau) = , expressed as a sum of exponentials, is presented. The method is applied to a granular flow system of 2-mm oil-filled spheres rotated in a half-filled horizontal cylinder, which is an Ornstein-Uhlenbeck process with velocity autocorrelation function R(u)(tau) = e(- ||tau ||/tau(c)), where tau(c) is the correlation time and D = tau(c) is the diffusion coefficient. The pulsed-field-gradient NMR method consists of applying three different gradient pulse sequences of varying motion sensitivity to distinguish the range of correlation times present for particle motion. Time-dependent apparent diffusion coefficients are measured for these three sequences and tau(c) and D are then calculated from the apparent diffusion coefficient images. For the cylinder rotation rate of 2.3 rad/s, the axial diffusion coefficient at the top center of the free surface was 5.5 x 10(-6) m(2)/s, the correlation time was 3 ms, and the velocity fluctuation or granular temperature was 1.8 x 10(-3) m(2)/s(2). This method is also applicable to study transport in systems involving turbulence and porous media flows.  相似文献   

12.
PurposeTo explore the application of histogram analysis in preoperative T and N staging of gastric cancers, with a focus on characteristic parameters of apparent diffusion coefficient (ADC) maps.Materials and methodsEighty-seven patients with gastric cancers underwent diffusion weighted magnetic resonance imaging (b = 0, 1000 s/mm2), which generated ADC maps. Whole-volume histogram analysis was performed on ADC maps and 7 characteristic parameters were obtained. All those patients underwent surgery and postoperative pathologic T and N stages were determined.ResultsFour parameters, including skew, kurtosis, s-sDav and sample number, showed significant differences among gastric cancers at different T and N stages. Most parameters correlated with T and N stages significantly and worked in differentiating gastric cancers at different T or N stages. Especially skew yielded a sensitivity of 0.758, a specificity of 0.810, and an area under the curve (AUC) of 0.802 for differentiating gastric cancers with and without lymph node metastasis (P < 0.001). All the parameters, except AUClow, showed good or excellent inter-observer agreement with intra-class correlation coefficients ranging from 0.710 to 0.991.ConclusionCharacteristic parameters derived from whole-volume ADC histogram analysis could help assessing preoperative T and N stages of gastric cancers.  相似文献   

13.
The approaching glass transition in polystyrene/toluene solutions leads to a sharp decay of both the collective diffusion coefficient D and the thermal diffusion coefficient D(T) at concentrations above 0.2 g/cm(3). The Soret coefficient S(T) = D(T)/D follows power-law scaling from semidilute to concentrated and is not influenced by the slowing down of the dynamics associated with the glass transition. Both D and D(T) are governed by the same friction coefficient. The scaling behavior of S(T) with concentration on approach of the glass transition is compared to the divergence of S(T) near a consolute critical point.  相似文献   

14.
PurposeTo assess the MRI performance in differentiating pancreatic ductal adenocarcinomas (PDACs), from solid pseudopapillary neoplasms (SPNs) and pancreatic neuroendocrine tumors (PNETs) using non-gaussian diffusion-weighted imaging models.MethodsThis was a retrospective study of patients diagnosed with PDACs (01/2015–06/2019) or with PNETs or SPNs diagnosed (01/2011–12/2019) at our hospital. The lesions were randomized 1:1 to the primary and validation cohorts. The regions of interest (ROIs) were manually drawn on each slice at DWI (b = 1500 s/mm2) from 3 T MRI. D (diffusion coefficient), D* (pseudodiffusion coefficient), f (perfusion fraction), distributed diffusion coefficient (DDC), α (diffusion heterogeneity index), mean diffusivity (MD) and mean kurtosis (MK) were obtained. The parameters with largest performance for differentiation were used to establish a diagnostic model.ResultsThere were 148, 56, and 60 patients with PDAC, PNET, and SPN, respectively. For differentiating PDACs from SPNs, f and MK values were used to establish a diagnostic model with areas under the receiver operating characteristic curves (AUCs) of 0.92 and 0.89 in the primary and validation groups, respectively. For distinguishing PDACs from PNETs, α and MK values were used to establish a diagnostic model with AUCs of 0.87 and 0.86 in the primary and validation groups, respectively. The accuracy rate of the subjective evaluation with the assistance of non-gaussian DWI models for differentiating PDAC from SPNs and PNETs were higher than that of subjective diagnosis alone (P < 0.05).ConclusionsThe non-gaussian DWI models could assist radiologists in accurately differentiating PDACs from PNETs and SPNs.  相似文献   

15.
Most statistical theories of anomalous diffusion rely on ensemble-averaged quantities such as the mean squared displacement. Single molecule tracking measurements require, however, temporal averaging. We contrast the two approaches in the case of continuous-time random walks with a power-law distribution of waiting times psi(t) proportional to t{-1-alpha}, with 0相似文献   

16.

High temperature Raman and Brillouin light scattering experiments have been combined with molecular dynamics simulations to provide a comprehensive study of the superionic state of BaF 2 ( x v mol% LaF 3 ) over a particularly wide range of LaF 3 dopant concentrations from x =0 to 50. Room temperature Raman spectra for x =0, 5 and 10 show the usual T 2g symmetry mode at 241 v cm m 1 , but for samples with x =20, 30 and 50 the dominant Raman mode is at higher frequencies and of E g symmetry. The temperature dependence of the Raman line-widths show initial near linear increases followed by substantial increases above temperatures ( T c ) at 1200, 850, 800, 975, 950 and 920 v K for x =0, 5, 10, 20, 30 and 50. In the Brillouin scattering experiments, the acoustic modes respectively related to elastic constants C 11 and C 44 initially showed a quasi-linear decrease in frequency with increasing temperature. Above the same characteristic values of T c , where the Raman line-widths show marked increases, there are substantial decreases in the elastic constant C 11 for all samples with x =0 to 50. Only the doped samples showed significant decreases in C 44 at corresponding values of T c . Molecular dynamics (MD) simulations have been carried out on the same systems. From the calculated mean square displacements, the diffusion coefficients ( D ) of the mobile fluorine ions were calculated as a function of temperature for each of the samples. Substantial increases in the values of D occur above the respective values of T c determined in the light scattering experiments. The MD simulations also provide details of the mechanisms of diffusion of the mobile fluorine ions. The results emphasize the role of motional effects as an explanation of the mechanisms responsible and provide a self-consistent explanation of the dominant processes in the superionic phase of doped fluorites.  相似文献   

17.
Diffusion of ferric ions in ferrous sulfate (Fricke) gels represents one of the main drawbacks of some radiation detectors, such as Fricke gel dosimeters. In practice, this disadvantage can be overcome by prompt dosimeter analysis, and constraining strongly the time between irradiation and analysis, implementing special dedicated protocols aimed at minimizing signal blurring due to diffusion effects. This work presents a novel analytic modeling and numerical calculation approach of diffusion coefficients in Fricke gel radiation sensitive materials. Samples are optically analyzed by means of visible light transmission measurements by capturing images with a charge-coupled device camera provided with a monochromatic filter corresponding to the XO-infused Fricke solution absorbance peak. Dose distributions in Fricke gels are suitably delivered by assessing specific initial conditions further studied by periodical sample image acquisitions. Diffusion coefficient calculations were performed using a set of computational algorithms based on inverse problem formulation. Although 1D approaches to the diffusion equation might provide estimations of the diffusion coefficient, it should be calculated in the 2D framework due to the intrinsic bi-dimensional characteristics of Fricke gel layers here considered as radiation dosimeters. Thus a suitable 2D diffusion model capable of determining diffusion coefficients was developed by fitting the obtained algorithm numerical solutions with the corresponding experimental data. Comparisons were performed by introducing an appropriate functional in order to analyze both experimental and numerical values. Solutions to the second-order diffusion equation are calculated in the framework of a dedicated method that incorporates finite element method. Moreover, optimized solutions can be attained by gradient-type minimization algorithms. Knowledge about diffusion coefficient for a Fricke gel radiation detector is helpful in accounting for effects regarding elapsed time between dosimeter irradiation and further analysis. Hence, corrections might be included in standard dependence of optical density differences and actual, non-diffused, absorbed dose distributions. The obtained values for ferric ion diffusion coefficient are around 0.65 mm2 h?1, being in good agreement with previous works corresponding to similar Fricke gel dosimeter compositions. Therefore, more accurate 2D and 3D dose mapping might be attained, thus constituting valuable improvements in Fricke gel dosimetry, and parallely a high precision method of diffusion modeling and calculation has been developed.  相似文献   

18.
Detailed measurements of water diffusion within the prostate over an extended b-factor range were performed to assess whether the standard assumption of monoexponential signal decay is appropriate in this organ. From nine men undergoing prostate MR staging examinations at 1.5 T, a single 10-mm-thick axial slice was scanned with a line scan diffusion imaging sequence in which 14 equally spaced b factors from 5 to 3,500 s/mm(2) were sampled along three orthogonal diffusion sensitization directions in 6 min. Due to the combination of long scan time and limited volume coverage associated with the multi-b-factor, multidirectional sampling, the slice was chosen online from the available T2-weighted axial images with the specific goal of enabling the sampling of presumed noncancerous regions of interest (ROIs) within the central gland (CG) and peripheral zone (PZ). Histology from prescan biopsy (n=9) and postsurgical resection (n=4) was subsequently employed to help confirm that the ROIs sampled were noncancerous. The CG ROIs were characterized from the T2-weighted images as primarily mixtures of glandular and stromal benign prostatic hyperplasia, which is prevalent in this population. The water signal decays with b factor from all ROIs were clearly non-monoexponential and better served with bi- vs. monoexponential fits, as tested using chi(2)-based F test analyses. Fits to biexponential decay functions yielded intersubject fast diffusion component fractions in the order of 0.73+/-0.08 for both CG and PZ ROIs, fast diffusion coefficients of 2.68+/-0.39 and 2.52+/-0.38 microm(2)/ms and slow diffusion coefficients of 0.44+/-0.16 and 0.23+/-0.16 um(2)/ms for CG and PZ ROIs, respectively. The difference between the slow diffusion coefficients within CG and PZ was statistically significant as assessed with a Mann-Whitney nonparametric test (P<.05). We conclude that a monoexponential model for water diffusion decay in prostate tissue is inadequate when a large range of b factors is sampled and that biexponential analyses are better suited for characterizing prostate diffusion decay curves.  相似文献   

19.
A mathematical model proposed for diffusion in spherical particles can be solved on a digital computer. The model includes particle size distribution and variable diffusion coefficient of the form D = DoeαC, where D is the diffusion coefficient, D0 and α are constants, and C is the moisture content. Isothermal experimental measurements were made gravimetrically on a Cahn electrobalance by vacuum sorption techniques. The model adequately predicts the absorption characteristics of water vapor in starch granules. Although swelling is neglected in the model, it does contribute to sorption characteristics.  相似文献   

20.

Fluorescence correlation spectroscopy (FCS) has been widely used to investigate molecular diffusion behavior in various samples. The use of the maximum entropy method (MEM) for FCS data analysis provides a unique means to determine multiple distinct diffusion coefficients without a priori assumption of their number. Comparison of the MEM-based FCS method (MEM-FCS) with another method will reveal its utility and advantage as an analytical tool to investigate diffusion dynamics. Herein, we measured diffusion of fluorescent probes doped into nanostructured thin films using MEM-FCS, and validated the results with single molecule tracking (SMT) data. The efficacy of the MEM code employed was first demonstrated by analyzing simulated FCS data for systems incorporating one and two diffusion modes with broadly distributed diffusion coefficients. The MEM analysis accurately afforded the number of distinct diffusion modes and their mean diffusion coefficients. These results contrasted with those obtained by fitting the simulated data to conventional two-component and anomalous diffusion models, which yielded inaccurate estimates of the diffusion coefficients. Subsequently, the MEM analysis was applied to FCS data acquired from hydrophilic dye molecules incorporated into microphase-separated polystyrene-block-poly(ethylene oxide) (PS-b-PEO) thin films characterized under a water-saturated N2 atmosphere. The MEM analysis revealed distinct fast and slow diffusion components attributable to molecules diffusing on the film surface and inside the film, respectively. SMT studies of the same materials yielded trajectories for mobile molecules that appear to follow the curved PEO microdomains. Diffusion coefficients obtained from the SMT data were consistent with those obtained for the slow diffusion component detected by MEM-FCS. These results highlight the utility of MEM-FCS and SMT for gaining complementary information on molecular diffusion processes in heterogeneous material systems.

Graphical Abstract
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号