共查询到20条相似文献,搜索用时 234 毫秒
1.
用苯基硅烷键合硅胶为填充剂的色谱柱,流动相A为水(用甲酸调节pH2.7),流动相B为乙腈;线性梯度洗脱,高效液相色谱法测定头孢西丁钠中的有关物质。本法专属性良好。 相似文献
2.
茶多酚中儿茶素类的HPLC分析 总被引:1,自引:0,他引:1
建立一种用高效液相色谱法(HPLC)测定茶叶中儿茶素类的方法,建立了同时分离测定了5种儿茶素组分(EGC、C、EGCG、EC、ECG)及咖啡碱(CAF)的方法,得到的最佳色谱条件为:ODS( 5μm,4.6mm×250mm)色谱柱,流动相A:0.1%的磷酸甲醇溶液;流动相B:0.1%的磷酸水溶液;流速为1.0mL/min;柱温为30℃;UV检测波长278nm.儿茶素单体及咖啡碱在给定的浓度范围内线性关系良好,方法精密度和重复性的相对标准偏差在5%以内,测定样品中各标准品的平均加标回收率为98.20%-100.64%.与国标法GB/T 8313-2008相比,本方法解决了国标法中EC和EGCG难分离的问题. 相似文献
3.
4.
5.
建立高效液相色谱法测定罗氟司特的有关物质.采用Shimadzu VP-ODS C18色谱柱,甲醇-醋酸铵缓冲液(pH 4.5)(60∶40)为流动相,检测波长为245nm,柱温25℃.罗氟司特检出限为9.3×10-10g·mL^-1,主成分与其相邻杂质峰分离良好.本方法简便、准确、灵敏度高、专属性好,可用于罗氟司特有关物质的测定. 相似文献
6.
7.
8.
9.
建立了高效液相色谱法同时测定养心草中没食子酸、槲皮素和山萘酚的含量。采用Hypersil C18色谱柱(4.6mm×200mm,5μm),流动相为甲醇(A)-0.2%磷酸水溶液(B),梯度洗脱,流速1.0mL/min;柱温25℃;检测波长260nm。在选定色谱条件下没食子酸、槲皮素和山萘酚线性关系良好;没食子酸、槲皮素和山萘酚加标回收率分别为98.37%、99.61%、97.81%,RSD分别为2.32%、2.15%、2.20%。方法简便快速,结果准确可靠,可用于控制中药养心草的质量。 相似文献
10.
11.
建立高效液相色谱法测定硫酸氢氯吡格雷中的有关物质的方法。其分解产物的检测,采用SinoChrom ODS-BP(200mm×4.6mm,5μm)色谱柱,以1%(V/V)三乙胺(pH=4.0)-乙腈(25∶75)为流动相,检测波长225nm,流速1.0mL/min。硫酸氢氯吡格雷在0.48—0.72μg范围内线性关系良好(r=0.9999),定量下限为3ng,检出限为0.6ng,各种破坏性样品的分离度符合规定。其光学纯度的测定采用ULTRON ES-OVM(Analytical)手性柱(150mm×4.6mm,5μm),色谱填料为L57。以磷酸盐缓冲液(pH=4.67)-乙腈(75∶25)为流动相,检测波长为220nm。硫酸氢氯吡格雷相关物质B分离度均大于2.5,符合要求。本方法简便,灵敏,准确,专属性强,能够满足硫酸氢氯吡格雷对有关物质测定的要求。 相似文献
12.
13.
14.
15.
利用超高效液相色谱串联质谱技术检测啤酒原料麦芽中的赤霉酸(Gibberellic acid,GA3)。样品由乙腈/水(80/20)提取后,经Oasis MAX固相萃取柱净化,以甲醇-甲酸水为流动相,梯度洗脱下,经选择离子模式(SIR)检测。结果表明,赤霉酸在ACQUITY UPLCTMBEH C18色谱柱上(2.1mm×100mm,1.7μm)得到较好分离,回收率为70%—78%,检出限0.6μg/L,RSD≤8.9%,该方法适用于麦芽等复杂体系中微量赤霉酸的检测。 相似文献
16.
Composition of mobile phase can greatly influence the success of electrospray ionization (ESI)-interfaced liquid chromatography-mass spectrometry analysis. To investigate the relationship between formic-acid-based modification of mobile phase and ESI nebulizing conditions, an API 4000 ESI source and a TSQ Quantum one were compared under the same chromatographic conditions. Ginkgo terpene lactones and flavonols were measured in plasma, which involved using ascorbic acid to circumvent cross-interference between the analytes. ESI responses to using formic acid included changes in signal intensity, matrix effect, and upper limit of quantification. Significant disparities in the responses were observed between the two ESI sources, suggesting that the use of electrolyte modifier in liquid chromatography mobile phase and the pneumatic nebulization for ESI should be properly balanced to accomplish optimal ESI-based analysis. The distribution of unpaired ions toward the surface of the initial droplet was assumed to be an important step in the pneumatic ESI process. When using the electrolyte in mobile phase, a too fast droplet reduction by rapid-heating-assisted pneumatic nebulization could negatively decrease the time available for the unpaired ions to migrate from droplet interior to its surface. Ascorbic acid was identified as a major interfering substance for the bioanalytical assay; the interference mechanism might be associated with hindering the unpaired analyte ions from distributing toward the droplet surface rather than outcompeting the analyte ions for the limited excess charge on droplets surface. The current work extends the knowledge base of pneumatic ESI, which has implication for optimal use of the ESI-interfaced liquid chromatography-mass spectrometry technique. 相似文献
17.
冷却水中异味污染物的LC-GC/FTIR联用分析 总被引:2,自引:0,他引:2
利用在线式高效液相色谱-毛细管气相色谱/傅里叶变换红光谱联用方法分析了某冷却水中的异味污染物。结果表明,污染系苯酚类化合物所致。 相似文献
18.
19.
20.
高效液相色谱法测定油炸南瓜饼中的丙烯酰胺 总被引:1,自引:0,他引:1
建立了一种利用高效液相色谱法测定油炸南瓜饼中丙烯酰胺含量的方法。样品经正己烷脱脂后用水作提取剂,提取液经高速离心处理后,上层清液用自制中性氧化铝小柱净化,高效液相色谱法测定,色谱条件:流动相为水;流速0.6mL/min;进样量5μL;保留时间6.6min;检测波长199.1nm;柱温30℃。方法的检出限为0.001μg/mL,回收率在87.50%—94.11%之间,相对标准偏差低于5%(n=6)。 相似文献