1.
This study focuses on porous silicon (pSi) fabrication methods and properties for desorption ionization on silicon mass spectrometry (DIOS-MS). PSi was prepared using electrochemical etching of n-type silicon in HF-ethanol solution. Porous areas were defined by a double-sided illumination arrangement: front-side porous areas were masked by a stencil mask, eliminating the need for standard photolithography, and backside illumination was used for the backside ohmic contact. Backside illumination improved the uniformity of the porosified areas. Porosification conditions, surface derivatizations and storage conditions were explored to optimize pSi area, pore size and pore depth. Chemical derivatization of the pSi surfaces improved the DIOS-MS performance providing better ionization efficiency and signal stability with lower laser energy. Droplet spreading and drying patterns on pSi were also examined. Pore sizes of 50-200 nm were found to be optimal for droplet evaporation and pore filling with the sample liquid, as measured by DIOS efficiency. With DIOS, significantly better detection sensitivity was obtained (e.g. 150 fmol for midazolam) than with desorption ionization from a standard MALDI steel plate without matrix addition (30 pmol for midazolam). Also the noise that disturbs the detection of low-molecular weight compounds at m/z < 500 with MALDI could be clearly reduced with DIOS. Low background MS spectra and good detection sensitivity at the 100-150 fmol level for pharmaceutical compounds were achieved with DIOS-MS.  相似文献   

2.
The study of low molecular weight compounds by matrix-assisted laser desorption/ionization (MALDI) is difficult because of the presence of ions originating from the matrix in the low-m/z range. In order to resolve these problems, new matrix-free approaches were developed based on laser desorption/ionization from the surface of various materials such as graphite and porous silicon. Our work involves the use of 'desorption ionization on porous silicon mass spectrometry' (DIOS-MS) in the negative ion mode to study fatty acid compounds. The potential of the DIOS-MS technique is shown and an insight into the ionization mechanism provided.  相似文献   

3.
Desorption/ionization on porous silicon (DIOS) is a form of laser desorption mass spectrometry that allows for the direct mass analysis of a variety of analytes without the addition of organic matrix. Protocols are described for the direct analysis of exocrine tissue and single neurons using DIOS-MS. The atrial gland of Aplysia californica was blotted on to porous silicon and analyzed with DIOS-MS in the range m/z 1000-4000. The ability to culture invertebrate neurons directly on porous silicon is also presented. Isolated bag cells regenerated neuronal processes in culture on porous silicon. DIOS-MS allowed the direct detection of the peptides contained in individual cultured neurons indicating that with appropriate protocols, DIOS can be used with biological samples with considerable thickness.  相似文献   

4.
Xu S  Pan C  Hu L  Zhang Y  Guo Z  Li X  Zou H 《Electrophoresis》2004,25(21-22):3669-3676
Desorption/ionization on silicon mass spectrometry (DIOS-MS) is a matrix-free technique that allows for the direct desorption/ionization of low-molecular-weight compounds with little or no fragmentation of analytes. This technique has a relatively high tolerance for contaminants commonly found in biological samples. DIOS-MS has been applied to determine the activity of immobilized enzymes on the porous silicon surface. Enzyme activities were also monitored with the addition of a competitive inhibitor in the substrate solution. It is demonstrated that this method can be applied to the screening of enzyme inhibitors. Furthermore, a method for peptide mapping analysis by in situ digestion of proteins on the porous silicon surface modified by trypsin, combined with matrix-assisted laser desorption/ionization-time of flight-MS has been developed.  相似文献   

5.
Halohydrination of epoxy resins using sodium halides as cationizing agents in matrix-assisted laser desorption/ionization (MALDI) and desorption ionization on porous silicon mass spectrometry (DIOS-MS) were investigated. Different mass spectra were observed when NaClO(4) and NaI were used as the cationizing agents at the highest concentration of 10.0 mM, which is much higher than that normally used in MALDI-MS. MALDI mass spectra of epoxy resins using NaI revealed iodohydrination to occur as epoxy functions of the polymers. The halohydrination also occurred using NaBr, but not NaCl, due to the differences in their nucleophilicities. On the basis of the results of experiments using deuterated CD(3)OD as the solvent, the hydrogen atom source was probably ambient water or residual solvent, rather than being derived from matrices. Halohydrination also occurred with DIOS-MS in which no organic matrix was used; in addition, reduction of epoxy functions was observed with DIOS. NaI is a useful cationizing agent for changing the chemical form of epoxy resins due to iodohydrination and, thus, for identifying the presence of epoxy functions.  相似文献   

6.
In this report, we describe the visible-laser desorption/ionization of biomolecules deposited on gold-coated porous silicon and gold nanorod arrays. The porous silicon made by electrochemical etching was coated with gold using argon ion sputtering. The gold nanorod arrays were fabricated by electrodepositing gold onto a porous alumina template, and the subsequent partial removal of the alumina template. A frequency-doubled/tripled Nd : YAG laser was used to irradiate the gold nanostructured substrate, and the desorbed molecular ions were mass-analyzed by a time-of-flight mass spectrometer. The desorption/ionization of biomolecules for both substrates was favored by the use of the 532-nm visible-laser, which is in the range of the localized surface plasmon resonance of the gold nanostructure. The present technique offers a potential analytical method for low-molecular-weight analytes that are rather difficult to handle in the conventional matrix-assisted laser desorption/ionization (MALDI) mass spectrometry.  相似文献   

7.
A low molecular mass polyester was analyzed by desorption/ionization on porous silicon (DIOS) mass spectrometry. The results were compared with those of matrix-assisted laser desorption ionization (MALDI) mass spectrometry using matrixes of alpha-cyano-4-hydroxycinnamic acid (CHCA) and 10,15,20-tetrakis(pentafluorophenyl)porphyrin (F20TPP). The CHCA matrix was not suitable for characterization of low molecular mass components of the polyester because the matrix-related ions interfered with the component ions. On the other hand, the F20TPP matrix showed no interference because no matrix-related ions appeared below m/z 822. However, the solvent selection for determining optimal conditions of sample preparation was limited, because F20TPP does not dissolve readily in any of the available organic solvents. In the DIOS spectra, the polymer ions were observed at high sensitivity without a contaminating ion. No matrix is needed for DIOS spectra of low molecular mass polyesters, facilitating sample preparation and selectivity of a precursor ion in post-source decay measurements.  相似文献   

8.
Mass discrimination effects in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) were quantitatively investigated using equiweight and equimolar mixtures of uniform polystyrene (PS) oligomers. Uniform PS oligomers were separated by preparative super-critical fluid chromatography (SFC) from commercial standard PS samples. The separated PS oligomers, with degrees of polymerization n = 2–25, have absolutely no molecular weight distributions. Equiweight and equimolar mixtures of uniform PS oligomers were accurately prepared by weighing by microbalance, and their spectra were recorded using a MALDI-TOF mass spectrometer. In the lower molecular weight region (less than about 103) the oligomers with lower molecular weights give lower mass spectral intensities, with no correlation with laser power. In contrast, higher laser powers yield a decrease of mass spectral intensities in the higher molecular weight region. These results clearly show that mass discrimination effects occur at lower and higher molecular weights depending on the laser power, and provide quantitative information about the discrimination. Using the data on equiweight and equimolar mixtures of PS oligomers, it was possible to calibrate the MALDI-TOF mass spectral data for an analysis of molecular weight distribution of a standard monodisperse PS sample with number-averaged molecular weight of 103, and to compare it with the molecular weight distribution measured by analytical SFC. The result from the calibrated MALDI-TOF mass spectrum, however, does not agree perfectly with that from the SFC results, because undetectable peaks in MALDI-TOF mass spectra at lower and higher molecular weights could not be included in the calibration of peak intensities. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

9.
Atmospheric pressure laser desorption/ionization on porous silicon   总被引:3,自引:0,他引:3  
A recently developed commercial atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) source (MassTech, Inc.) was modified to adopt commercially available DIOS plates (Mass Consortium Corp.) for the studies of laser desorption from the surface of porous silicon under atmospheric pressure conditions. The feasibility of atmospheric pressure laser desorption/ionization from the surface of porous silicon (AP-DIOS) was demonstrated. The advantages of this new AP-DIOS technique include reasonably good sensitivity (subpicomole range for standard peptide mixtures), simplicity of sample preparation, uniformity of target spots and the absence of matrix peaks in the spectra. The AP-DIOS source was interfaced with a commercial ion trap (LCQ Classic, Thermo Finnigan) which additionally provides a unique MS(n) capability. The AP-DIOS spectrum of 250 fmol of unseparated tryptic digest of bovine serum albumin (BSA) was compared with that of AP-MALDI for the same compound. AP-DIOS offers significantly better coverage for the digest components in the mass range 200-1000 Da. The combined data of both techniques enabled us to nearly double the number of matched peaks in BSA digest analysis compared with AP-DIOS or AP-MALDI analysis separately.  相似文献   

10.
Electrospray droplet impact (EDI)/secondary ion mass spectrometry (SIMS) is a new desorption/ionization technique for mass spectrometry in which highly charged water clusters produced from the atmospheric‐pressure electrospray are accelerated in vacuum by several kV and impact the sample deposited on the metal substrate. In this study, several industrial synthetic polymers, e.g. polystyrene (PS) and polyethylene glycol (PEG) were analyzed by EDI/SIMS mass spectrometry. For higher molecular weight analytes, e.g. PS4000 and PEG4600, EDI/SIMS mass spectra could be obtained when cationization salts are added. For the polymers of lower molecular weights, e.g. PEG300 and PEG600, they could be readily detected as protonated ions without the addition of cationization agents. Anionized PS was also observed in the negative ion mode of operation when acetic acid was added to the charged droplet. Compared to matrix‐assisted laser desorption/ionization (MALDI), ion signal distribution with lower background signals could be obtained particularly for the low‐molecular weight polymers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
MALDI质谱检测蛋白质与富勒醇的非共价复合物   总被引:4,自引:0,他引:4  
基质辅助激光解吸电离(MALDI)质谱由于受到酸性基质、样品制备、激光诱导聚合和基质加合物的形成等条件的限制而难以用于非共价复合物的检测.本文以芥子酸为基质,观察到蛋白质与富勒醇的特殊相互作用,一些质谱特征,如质量数迁移、宽的加合峰和定量结合比表明,在蛋白质和富勒醇之间形成了特殊的非共价复合物.其中,血红蛋白与富勒醇的结合比是1:4,而肌红蛋白与富勒醇的结合比是1:1.实验结果表明:富勒醇可用来保护血红蛋白,有在酸性介质中防止其分解的作用.因此,通过在基质组份中添加特性有机化合物保护被测样品,有可能实现用MALDI质谱测定四级结构蛋白质的分子量.  相似文献   

12.
The applicability of the matrix-free laser desorption/ionization on silicon mass spectrometry (DIOS-MS) to measuring serum drug levels was examined by analyzing serum salicylic acid. The optimized and simple solid-phase extraction (SPE) allowed good recovery, 88.9 +/- 5.8%, for 1.4 mM (200 mg/L) of salicylic acid in serum. The negative ion MS allowed measurements of deprotonated molecules without interference from other signals. Using a deuterium-labeled internal standard, good linearity was obtained in the 0.14 to 4.2 mM (20-600 mg/L) range, which was sufficient for monitoring the therapeutic anti-inflammatory dose. SPE followed by DIOS-MS is anticipated to be a method of measuring drug levels in blood and may allow high throughput analysis.  相似文献   

13.
Iminodiacetic acid (IDA)-1,2-epoxy-9-decene has been synthesized and covalently linked to the surface of porous silicon wafer through a photochemical reaction. The negatively charged carboxylic acid groups on the porous silicon wafer are capable of binding oppositely charged species from sample solutions through electrostatic interactions. This allows the removal of contaminants prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) by simply washing the porous silicon surface. The carboxylic acid end groups on porous silicon can be used to selectively bind and concentrate target species in sample solutions. Furthermore, Fe(3+)-IDA-derivatized porous silicon was prepared to specifically and effectively concentrate phosphopeptides from the tryptic digests of phosphoproteins, followed by MALDI-MS analysis.  相似文献   

14.
A matrix-free, high sensitivity, nanostructured silicon surface assisted laser desorption/ionization mass spectrometry (LDI-MS) method fabricated by metal-assisted etching was investigated. Effects of key process parameters, such as etching time, substrate resistance and etchant composition, on the nanostructured silicon formation and its LDI-MS efficiency were studied. The results show that the nanostructured silicon pore depth and size increase with etching time, while MS ion intensity increases with etching time to 300 s then decreases until 600 s for both low resistance (0.001–0.02 Ω cm) and high resistance (1–100 Ω cm) silicon substrates. The nanostructured silicon surface morphologies were found to directly affect the LDI-MS signal ion intensity. By characterizing the nanostructured silicon surface roughness using atomic force microscopy (AFM) and sample absorption efficiency using fluorescence microscopy, it was further demonstrated that the nanostructured silicon surface roughness was highly correlated to the LDI-MS performance.  相似文献   

15.
A new solvent-free sample preparation method using silver trifluoroacetate (AgTFA) was developed for the analysis of low molecular weight paraffins and microcrystalline waxes by laser desorption/ionization time-of-flight mass spectrometry (LDI-TOFMS). Experiments show that spectral quality can be enhanced by dispersing AgTFA directly in liquid paraffins without the use of additional solvents. This preparation mixture is applied directly to the MALDI probe. Solid waxes could be examined by melting prior to analysis. The method also provides sufficiently reproducible spectra that peak area ratios between mono- and bicyclic alkane peaks indicated variations in the cycloalkane content of paraffin samples. Dehydrogenation of hydrocarbons observed during the desorption/ionization process was studied by analysis of alkane standards.  相似文献   

16.
Glancing angle deposition (GLAD) was used to fabricate nanostructured silicon (Si) thin films with highly controlled morphology for use in laser desorption/ionization mass spectrometry (DIOS‐MS). Peptides, drugs and metabolites in the mass range of 150–2500 Da were readily analyzed. The best performance was obtained with 500 nm thick films deposited at a deposition angle of 85°. Low background mass spectra and attomole detection limits were observed with DIOS‐MS for various peptides. Films used after three months of dry storage in ambient conditions produced mass spectra with negligible low‐mass noise following a 15 min UV‐ozone treatment. The performance of the Si GLAD films was as good as or better than that reported for electrochemically etched porous silicon and related materials, and was superior to matrix‐assisted laser desorption/ionization (MALDI)‐MS for analysis of mixtures of small molecules between 150–2500 Da in terms of background chemical noise, detection limits and spot‐to‐spot reproducibility. The spot‐to‐spot reproducibility of signal intensities (100 shots/spectrum) from 21 different Si GLAD film targets was ±13% relative standard deviation (RSD). The single shot‐to‐shot reproducibility of signals on a single target was ±19% RSD (n = 7), with no indication of sweet spots or mute spots. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
Porous poly(butyl methacrylate-co-ethylene dimethacrylate), poly(benzyl methacrylate-co-ethylene dimethacrylate), and poly(styrene-co-divinylbenzene) monoliths have been prepared on the top of standard sample plates used for matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and the modified plates were used for laser desorption/ionization mass spectrometry (LDI-MS). The hydrophobic porous surface of these monoliths enables the transfer of sufficient energy to the analyte to induce desorption and ionization prior to TOFMS analysis. Both UV and thermally initiated polymerization using a mask or circular openings in a thin gasket have been used to define spot locations matching those of the MALDI plates. The desorption/ionization ability of the monolithic materials depends on the applied laser power, the solvent used for sample preparation, and the pore size of the monoliths. The monolithic matrices are very stable and can be used even after long storage times in a typical laboratory environment without observing any deterioration of their properties. The performance of the monolithic material is demonstrated with the mass analysis of several small molecules including drugs, explosives, and acid labile compounds. The macroporous spots also enable the archiving of samples.  相似文献   

18.
This review summarizes various approaches for the analysis of low molecular weight (LMW) compounds by different laser desorption/ionization mass spectrometry techniques (LDI-MS). It is common to use an agent to assist the ionization, and small molecules are normally difficult to analyze by, e.g., matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) using the common matrices available today, because the latter are generally small organic compounds themselves. This often results in severe suppression of analyte peaks, or interference of the matrix and analyte signals in the low mass region. However, intrinsic properties of several LDI techniques such as high sensitivity, low sample consumption, high tolerance towards salts and solid particles, and rapid analysis have stimulated scientists to develop methods to circumvent matrix-related issues in the analysis of LMW molecules. Recent developments within this field as well as historical considerations and future prospects are presented in this review.  相似文献   

19.
We have developed surface-assisted laser desorption/ionization mass spectrometry using zinc oxide (ZnO) nanoparticles with anisotropic shapes (ZnO-SALDI-MS). The mass spectra showed low background noises in the low m/z, i.e. less than 500 u region. Thus, we succeeded in SALDI ionization on low molecular weight organic compounds, such as verapamil hydrochloride, testosterone, and polypropylene glycol (PPG) (average molecular weight 400) without using a liquid matrix or buffers such as citric acids. In addition, we found that ZnO-SALDI has advantages in post-source decay (PSD) analysis and produced a simple mass spectrum for phospholipids. The ZnO-SALDI spectra for synthetic polymers of polyethylene glycol (PEG), polystyrene (PS) and polymethylmethacrylate (PMMA) showed the sensitivity and molecular weight distribution to be comparable to matrix-assisted laser desorption/ionization (MALDI) spectra with a 2,5-dihydroxybenzoic acid (DHB) matrix. ZnO-SALDI shows good performance for synthetic polymers as well as low molecular weight organic compounds.  相似文献   

20.
Chemically modified silicon nanoparticles were applied for the laser desorption/negative ionization of small acids. A series of substituted sulfonic acids and fatty acids was studied. Compared to desorption ionization on porous silicon (DIOS) and other matrix-less laser desorption/ionization techniques, silicon nanoparticle-assisted laser desorption/ionization (SPALDI) mass spectrometry allows for the analysis of acids in the negative ion mode without the observation of multimers or cation adducts. Using SPALDI, detection limits of many acids reached levels down to 50 pmol/μl. SPALDI of fatty acids with unmodified silicon nanoparticles was compared to SPALDI using the fluoroalkyl silylated silicon powder, with the unmodified particles showing better sensitivity for fatty acids, but with more low-mass background due to impurities and surfactants in the untreated silicon powder. The fatty acids exhibited a size-dependent response in both SPALDI and unmodified SPALDI, showing a signal intensity increase with the chain length of the fatty acids (C12-C18), leveling off at chain lengths of C18-C22. The size effect may be due to the crystallization of long chain fatty acids on the silicon. This hypothesis was further explored and supported by SPALDI of several, similar sized, unsaturated fatty acids with various crystallinities. Fatty acids in milk lipids and tick nymph samples were directly detected and their concentration ratios were determined by SPALDI mass spectrometry without complicated and time-consuming purification and esterification required in the traditional analysis of fatty acids by gas chromatography (GC). These results suggest that SPALDI mass spectrometry has the potential application in fast screening for small acids in crude samples with minimal sample preparation.  相似文献   