首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
A sensitive and selective liquid chromatography coupled to tandem mass spectrometry (LC‐MS/MS) was developed and validated for the determination of salbutamol in human plasma and urine, and successfully applied to the pharmacokinetic study of salbutamol in Chinese healthy volunteers after inhalation of salbutamol sulfate aerosol. Salbutamol and the internal standard (IS) acetaminophen in plasma and urine were extracted with ethyl acetate, separated on a C18 reversed‐phase column, eluted with mobile phase of acetonitrile–ammonium acetate (5 m m ; 30:70, v/v), ionized by positive ion pneumatically assisted electrospray and detected in the multi‐reaction monitoring mode using precursor → product ions of m/z 240.2 → 148.1 for salbutamol and 152 → 110 for the IS. The lower limits of quantitation of salbutamol in human plasma and urine by this method were 0.02 and 1 ng/mL, respectively. The specificity, matrix effect, recovery, sensitivity, linearity, accuracy, precision and several stabilities were validated for salbutamol in human plasma and urine. In conclusion, the validation results showed that this method is robust, specific and sensitive, and can successfully fulfill the requirement of clinical pharmacokinetic study of salbutamol in healthy Chinese volunteers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
This study describes the development of a rapid and sensitive high‐performance liquid chromatography–electrospray ionization tandem mass spectrometry (LC‐MS/MS) assay for the quantification of [6]‐gingerol in mouse plasma and application to a pharmacokinetic study after dose ranging in mice. The assay involved a protein precipitation step with acetonitrile and an isocratic elution using a mobile phase consisting of acetonitrile and water containing 0.1% formic acid (80:20 v/v). The multiple reaction monitoring was based on the transition of m/z = 277.2 → 177.1 for [6]‐gingerol and 294.2 → 137.1 for nonivamide (internal standard). The assay was validated to demonstrate the specificity, linearity, recovery, accuracy, precision and stability. The calibration curves were linear over the wide concentration range of 10–10,000 ng/mL (r ≥ 0.9988). The lower limit of quantification was 10 ng/mL using a small volume of mouse plasma (20 μL). The method was successfully applied to a pharmacokinetic study in mice after intravenous injection of [6]‐gingerol at 1.5, 3 and 6 mg/kg doses. The pharmacokinetics of [6]‐gingerol were linear over the dose range studied as demonstrated by the linear increase in area under the concentration‐time curve (AUCinf) with no significant change in the systemic clearance (Cls), volume of distribution (Vss) and elimination half‐life (t1/2) as a function of dose. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

4.
A sensitive and rapid liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method has been developed and validated for the determination of asperosaponin VI in beagle dog plasma using glycyrrhizic acid as the internal standard (IS). Plasma samples were simply pretreated with methanol for deproteinization. Chromatographic separation was performed on a Hedera ODS‐2 column using mobile phase of methanol–10 mm ammonium acetate buffer solution containing 0.05% acetic acid (71:29, v/v) at a flow rate of 0.38 mL/min. Asperosaponin VI and the IS were eluted at 2.8 and 1.9 min, respectively, ionized in negative ion mode, and then detected by multiple reaction monitoring. The detection used the transitions of the deprotonated molecules at m/z 927.5 → 603.4 for asperosaponin VI and m/z 821.4 → 645.4 for glycyrrhizic acid (IS). The assay was linear over the concentration range of 0.15–700 ng/mL and was successfully applied to a pilot pharmacokinetic study in beagle dogs. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
Imidol hydrochloride is a novel drug for the treatment of hepatitis B virus infection. A simple, special and sensitive solid‐phase extraction liquid chromatography–tandem mass spectrometry method for determination of imidol in human plasma and urine was developed for the first time and applied to a pharmacokinetic study. The chromatographic separation was achieved on a C18 column (50 × 2.1 mm, 3.5 µm) using gradient elution with acetonitrile and water both containing 0.1% acetic acid at a flow rate of 0.25 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via a positive eletrospray ionization source. The mass transition pairs of m/z 517.8 → 325 and m/z 298 → 174 were used to detect imidol and the (?)‐clausenamide (internal standard), respectively. The retention times of imidol and (?)‐clausenamide were 2.5 and 2.7 min, respectively. Linearity, accuracy, precision, recovery, matrix effect, dilution test and stability were evaluated during method validation over the range of 0.2–500 ng/mL in human plasma and 0.5–500 ng/mL in urine. The method was successfully applied to a clinical pharmacokinetic study of imidol in healthy volunteers following oral administration. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
A sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of sodium cromoglycate (SCG) in human plasma after a nasal dose of 10.4 mg sodium cromoglycate nasal spray, using pravastatin sodium as the internal standard. The method was validated over a linear range of 0.300-20.0 ng/mL. SCG and I.S. were extracted from 1.0 mL of heparinized plasma by C(18) solid-phase extraction cartridges using methanol as eluting solvent. The dried residue was reconstituted with 100 microL of mobile phase, and 10 microL was injected onto the LC-MS/MS system. Chromatographic separation was achieved on a C(18) column (250 x 4.6 mm i.d., 5 microm particle size) with a mobile phase of methanol-acetonitrile-water (containing 2 mmol/L ammonium acetate; 42.5:42.5:15, v/v/v) at a flow rate of 0.4 mL/min. The analytes were detected with a triple quad LC-MS/MS using ESI with positive ionization. Ions monitored in the multiple reaction monitoring mode were m/z 469.0 (precursor ion) to m/z 245.0 (product ion) for SCG and m/z 447.2 (precursor ion) to m/z327.1 (product ion) for pravastatin sodium (internal standard) The average recovery of SCG from human plasma was 94.88% and the lower limit of quantitation was 0.3 ng/mL. Results from a 3-day validation study demonstrated excellent precision and accuracy across the calibration range of 0.3-20 ng/mL. The method was successfully applied to the pharmacokinetic study of SCG in healthy Chinese volunteers. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

7.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of ziprasidone (ZIP) in human plasma was developed. ZIP and N-methyl ziprasidone as internal standard (IS) were extracted from alkalinized plasma using tert- butyl methyl ether. Separation was performed isocratically on a C8 column with 90% acetonitrile containing 2 mmol/L ammonium acetate as a mobile phase with a total run time of 2.5 min. MS/MS transitions of m/z 413 --> 194 and m/z 427 --> 177 of the analyte and internal standard were used for quantification. Confirmatory ions of m/z 413 --> 177 and m/z 427 --> 180 were collected as well. The calibration curve based on peak-area ratio was linear up to at least 200 ng/mL with a detection limit of 0.1 ng/mL. The method showed satisfactory reproducibility with a coefficient of variation of less than 5%. The method was successfully applied to the analysis of ZIP in spiked human plasma.  相似文献   

8.
A sensitive and selective liquid chromatography mass spectrometry method for determination of curdione in rabbit plasma was developed. After addition of tramadol as internal standard (IS), protein precipitation by acetonitrile was used for sample preparation. Chromatographic separation was achieved on a Zorbax SB‐C18 (2.1 × 50 mm, 3.5 µm) column with acetonitrile–0.1% formic acid as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive‐ion mode; selective ion monitoring was used for quantification using target fragment ions m/z 237 for curdione and m/z 264 for the IS. Calibration plots were linear over the range of 20–4000 ng/mL for curdione in plasma. The lower limit of quantification for curdione was 20 ng/mL. Mean recovery of curdione from plasma was in the range 94.3–98.4%. The RSD of intra‐day and inter‐day precision were both less than 9%. This method is simple and sensitive enough to be used in pharmacokinetic research for the determination of curdione in rabbit plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
A method has been developed for the simultaneous quantification of metformin (I) and glipizide (II) in human plasma. It is based on high-performance liquid chromatography with electrospray ionization tandem mass (LC-ESI-MS/MS) spectrometric detection in positive ionization mode. Phenformin (III) and gliclazide (IV) were used as internal standards for I and II, respectively. The MS/MS detection was performed in multiple reaction monitoring (MRM) mode. The precursor-product ion combinations of m/z 130 --> 71, 446 --> 321, 206 --> 60 and 324 --> 127 were used to quantify I, II, III and IV, respectively. This method was validated in the concentration ranges of 0.02-4 microg/mL for I and 0.004-0.8 microg/mL for II. It was utilized to support a clinical pharmacokinetic study after single dose oral administration of a combination of I and II.  相似文献   

10.
A sensitive and selective liquid chromatography tandem mass spectrometry method for determination of azasetron hydrochloride in rabbit plasma was developed. After addition of doxapram hydrochloride as internal standard (IS), protein precipitation by 10% trichloroacetic acid was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB-C(18) (2.1 × 50 mm, 3.5 μm) column with acetonitrile-water as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used to quantification using target fragment ions m/z 349.9 → 223.5 for azasetron hydrochloride and m/z 378.9 → 291.8 for the IS. Calibration plots were linear over the range of 6-1000 ng/mL for azasetron hydrochloride in plasma. The lower limit of quantitation for azasetron hydrochloride was 6 ng/mL. The mean recovery of azasetron hydrochloride from plasma was in the range 85.6-92.7%. The RSDs of intra-day and inter-day precision were both less than 12%. This method is simple and sensitive enough to be used in pharmacokinetic research for determination of azasetron hydrochloride in rabbit plasma.  相似文献   

11.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of nicorandil in human plasma. Nicorandil was extracted from human plasma using solid-phase extraction technique. Imipramine was used as the internal standard. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection at nanogram levels. The proposed method has been validated for a linear range of 1.0-500.0 ng/mL with a correlation coefficient of > or =0.9993. The intra-run and inter-run precision and accuracy was within 10.0%. The overall recovery for nicorandil was 63.81%. The total run time was just 3.0 min.  相似文献   

12.
A rapid and sensitive LC/MS/MS assay was developed and validated for the determination of clopidogrel in human plasma. Clopidogrel was extracted by single liquid-liquid extraction with pentane, and chromatographic separations were achieved on a C(18) column. The method was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), stability, accuracy and precision. The multiple reaction monitoring was based on m/z transition of 322.2 --> 211.9 for clopidogrel and 264.1 --> 125.1 for ticlopidine (internal standard). The total analytical run time was relatively short (3 min), and the LLOQ was 10 pg/mL using 0.5 mL of human plasma. The assay was linear over a concentration range from 10 to 10,000 pg/mL (r > 0.999). The intra- and inter-day accuracies were 101.3-108.8 and 98.4-103.5%, respectively, and the intra- and inter-day assay precisions were 1.9-5.5 and 4.4-8.1%, respectively. The developed assay method was applied to a pharmacokinetic study in human volunteers after oral administration of clopidogrel at a dose of 150 mg.  相似文献   

13.
A quantitative analysis of polyamines in urine and serum by liquid chromatography-tandem mass spectrometry (LC-MS/MS) is described. The polyamines were carbamylated with isobutyl chloroformate, extracted with diethyl ether under pH 9.0, and analyzed by LC-MS/MS with single reaction monitoring mode. The limit of quantification was 1 ng/mL based on a signal-to-noise ratio>3, and the correlation coefficient (r2) for the calibration curves was >0.99 for both urine and serum samples. The present method was applied to urine and serum samples from 30 breast cancer patients and 30 normal female controls. There was no significant difference in the urinary polyamine levels between breast cancer patients and controls. However, 1,3-diaminopropane, putrescine, spermine and N-acetylspermidine levels in serum increased in breast cancer patients. These four serum polyamines may be a good index to study both production and metabolism of polyamines, and a useful tool in assessment of the polyamine status of breast cancer patients.  相似文献   

14.
A specific, sensitive and rapid method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC‐MS/MS) was developed for the determination of pseudo‐ginsenoside GQ in human plasma. Liquid–liquid extraction was used to isolate the analyte from biological matrix followed by injection of the extracts onto a C8 column with isocratic elution. Detection was carried out on a triple quadrupole tandem mass spectrometer (API‐4000 system) in multiple reaction monitoring mode using negative electrospray ionization. The mobile phase consisted of methanol–10 mm ammonium acetate (90:10, v/v) and the flow rate was 0.3 mL/min. The method was validated over the concentration range of 5.0–5000.0 ng/mL for plasma. Inter‐ and intra‐day precisions (relative standard deviation) were all within 15% and the accuracy (relative error) was ≤9.4%. The lower limit of quantitation was 5.0 ng/mL. The pseudo‐ginsenoside GQ was stable after 8 h at room temperature, 24 h at autosampler and three freeze–thaw cycles (from ?30 to 25 °C). The method was successfully applied to the pharmacokinetic study of pseudo‐ginsenoside GQ in healthy Chinese volunteers. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
A sensitive liquid chromatographic-tandem mass spectrometry(LC-MS/MS) method was developed for the determination of rizatriptan in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax XDB C8 column (150 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an electrospray ionization interface. Zomitriptan was used as the internal standard. The method had a lower limit of quantitation of 50 pg/mL for rizatriptan, which showed more sensitivity and speed of analysis compared with reported methods. The within- and between-day precision was measured to be below 11.71% and accuracy between -5.87 and 0.86% for all quality control samples. This quantitation method was successfully applied to the evaluation of the pharmacokinetic profiles of rizatriptan after single oral administration of 5, 10 and 15 mg rizatriptan tablets to 10 healthy volunteers (five males and five females).  相似文献   

16.
A sensitive, rapid and specific high‐performance liquid chromatography tandem mass spectrometry method (HPLC‐MS/MS) was developed to determine ecliptasaponin A in rat plasma and tissues after oral administration. Ginsenoside Rg1 was used as the internal standard (IS). The plasma and tissues samples were prepared by liquid‐liquid extraction with ethyl acetate and separated on an Eclipse Plus C18 column (2.1 mm × 150 mm, 5 µm) at a flow rate of 0.4 mL/min using acetonitrile and water (containing 0.05% acetic acid) as the mobile phase. The tandem mass detection was carried out with eletrospray ionization in negative mode. Quantification was performed by using multiple reaction monitoring (MRM), which monitored the fragmentation of m/z 633.4→587.2 for ecliptasaponin A and m/z 859.4→637.4 for the IS. The calibration curves obtained were linear in different matrices, and the lower limit of quantification (LLOQ) achieved was 0.5 ng/mL both for rat plasma and tissues. The intra‐ and inter‐day precisions were below 15%. This method was successfully applied to pharmacokinetic study of ecliptasaponin A in rat plasma and tissues after oral administration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
We developed a LC‐MS/MS method for the determination of esculetin contents in medicinal plants. The analysis was performed using multiple reaction monitoring in negative mode, and an XBridge? C18 column (2.1 × 100 mm, 3.5 µm) was used. Methanol and 0.1% formic acid were used for gradient analysis. The calibration curve showed good linearity (r2 > 0.9993). The limits of detection and quantitation were 0.02 and 0.07 ng/mL, respectively. The intra‐day and inter‐day precisions were 1.5–6.8 and 2.0–5.3%, respectively, and the accuracy was 102.0–110.2%. The contents of esculetin in 35 different plants were determined, and Fraxini Cortex showed the highest content of esculetin (761–5475 mg/kg). In Mori Folium and Artemisiae Capillaris Herba, 5.2–21.5 and 7.0–17.6 mg/kg of esculetin were found, respectively. In other medicinal plants, no esculetin was detected, or it was present at a concentration less than 10 mg/kg. The analysis method appears to be simple, sensitive and reproducible. Contrary to expectations based on traditional medical knowledge, although Artemisiae Capillaris Herba contains a large amount of esculetin, it appears from this study that Fraxini Cortex contains a greater amount. The pharmacological effects of esculetin isolated from medicinal plants should be investigated as part of new medicines development. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
Sodium tanshinone IIA sulfonate (STS) is a water-soluble derivative of tanshinone IIa, an important lipophilic component contained in Salvia miltiorrhizae. A simple, sensitive and robust quantification method for STS based on LC-ESI-MS/MS was developed and validated, and has been successfully applied to the pharmacokinetic study. Liquid-liquid extraction was used for extracting STS from biological samples, with a satisfactory recovery exceeding 75% at all test concentrations. Isocratic mobile phase consisted of 75% acetonitrile and 25% water containing 0.005% ammonia acetate (pH 3). Good retention and baseline separation for STS and the selected internal standard, diclofenac sodium, were obtained on a Shim-pack VP-ODS analytical column under this condition. The method was linear in the concentration range of 1-500 ng/mL. The intra- and inter-day precisions (RSD%) were within 9.0%. The deviation of the assay accuracies was within +/-10.0%. STS was proved to be stable during all sample storing, preparation and analytic procedures. With a lower limit of quantitation at 1 ng/mL, this method has been proved to be sensitive enough for the pharmacokinetic study of STS. The plasma profile of STS followed a single intravenous dosing was well fitted to a three compartmental model.  相似文献   

19.
A simple, sensitive, selective and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of atorvastatin and its active metabolites ortho-hydroxyatorvastatin and para-hydroxyatorvastatin in human plasma using rosuvastatin as internal standard (IS). Following simple liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 559/440 for atorvastatin, m/z 575/466 for ortho-hydroxyatorvastatin, m/z 575/440 for para-hydroxyatorvastatin and m/z 482/258 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for atorvastatin and its two metabolites in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of atorvastatin, ortho-hydroxyatorvastatin, para-hydroxyatorvastatin and the IS from spiked plasma samples were 54.2 +/- 3.2, 50.1 +/- 3.8, 65.2 +/- 3.6 and 71.7 +/- 2.7%, respectively. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

20.
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号