首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The octadecylamine-capped gold nanoparticles (ODA-Au-NPs) were prepared and directly used to coat the capillary wall. The hydrophobic coating acted as the stationary phase for open-tubular gas chromatography (OTGC). The ODA-Au-NPs can be adsorbed tightly onto the inner surface of fused silica capillary column via electrostatic interaction and enhanced interaction of van der Waals between gold nanoparticles and the capillary wall. Thus, the modification of the inner surface of capillary column by ODA-Au-NPs can be achieved simply by flushing the capillary with a solution of ODA-Au-NPs and the resulted ODA-Au-NPs coating is very stable. No perceptible degradation in the ODA-Au-NPs-based separation was observed after ∼1900 sample runs. This type of columns also provided excellent chromatographic performances: high number of theoretical plates, outstanding run-to-run and column-to-column reproducibility, and high selectivity for a wide range of test mixtures. An efficiency of 2474 theoretical plates per meter for chlorobenzene was obtained on an ODA-Au-NPs-modified 1.6 m × 100 μm i.d. fused silica capillary column.  相似文献   

2.
Wu R  Zou H  Fu H  Jin W  Ye M 《Electrophoresis》2002,23(9):1239-1245
The mixed mode of reversed phase (RP) and strong cation-exchange (SCX) capillary electrochromatography (CEC) based on a monolithic capillary column has been developed. The capillary monolithic column was prepared by in situ copolymerization of 2-(sulfooxy)ethyl methacrylate (SEMA) and ethylene dimethacrylate (EDMA) in the presence of porogens. The sulfate group provided by the monomer SEMA on the monolithic bed is used for the generation of the electroosmotic flow (EOF) from the anode to the cathode, but at the same time serves as a SCX stationary phase. A mixed-mode (RP/SCX) mechanism for separation of peptides was observed in the monolithic column, comprising hydrophobic and electrostatic interaction as well as electrophoretic migration at a low pH value of mobile phase. A column efficiency of more than 280,000 plates/m for the unretained compound has been obtained on the prepared monoliths. The relative standard deviations observed for t(0) and retention factors of peptides were about 0.32% and less than 0.71% for ten consecutive runs, respectively. Effects of mobile phase compositions on the EOF of the monolithic column and on the separation of peptides were investigated. The selectivity on separation of peptides in the monolithic capillary column could be easily manipulated by varying the mobile phase composition.  相似文献   

3.
Dong X  Wu R  Dong J  Wu M  Zhu Y  Zou H 《Electrophoresis》2008,29(18):3933-3940
An approach of immobilizing mobile crystalline material (MCM)-41 mesoporous silica nanoparticles on the inner wall of an open-tubular (OT) capillary as the support for coating chiral selector of cellulose tris(3,5-dimethylphenyl-carbamate) (CDMPC) was carried out. By taking advantage of the improved phase ratio of OT capillary with the immobilization of MCM-41 mesoporous material, the cellulose derivative of CDMPC as the chiral selector was simply coated on the MCM-41 nanoparticle layer via the hydrogen-bonding interaction, and the enantioseparation was successively carried out. Eight pairs of acidic, neutral and basic enantiomers were resolved in capillary electrochromatography or capillary liquid chromatography mode. The concentration of CDMPC for coating was systematically investigated to obtain the optimized chromatographic properties on enantioseparation by controlling the supposed film thickness of CDMPC on MCM-41 nanoparticle layer. Comparing with a bare fused silica capillary column coated with CDMPC under the same coating procedure as MCM-41-modified capillary did, the MCM-41-modified capillary column offered much higher enantioselectivity. This result indicated the significance of using the mesoporous nanoparticles as the electrochromatographic support to enhance the phase ratio of OT capillary column in capillary electrochromatography and capillary liquid chromatography. For investigating the effect of experimental conditions on the enantioseparation with this prepared OT capillary column, the content of organic modifier acetonitrile in the mobile phase was thus extensively evaluated to achieve a better chiral separation.  相似文献   

4.
A novel open‐tubular capillary electrochromatography column coated with β‐cyclodextrin was prepared using the sol‐gel technique. In the sol‐gel approach, owing to the three‐dimensional network of sol‐gel and the strong chemical bond between the stationary phase and the surface of capillary columns, good chromatographic characteristics and unique selectivity in separating enantiomers were shown. The influences of capillary inner diameter, coating time, organic modifier, buffer pH, and buffer concentration on separation were investigated. The sol‐gel‐coated β‐cyclodextrin column has shown improved enantioseparation efficiency of chlorphenamine, brompheniramine, pheniramine, zopiclone in comparison with the sol‐gel matrix capillary column. The migration time relative standard deviation of the separation of the enantiomers was less than 0.89% over five runs and 2.9% from column to column. This work confirmed that gold nanoparticles are promising electrochromatographic support to enhance the phase ratio of open‐tubular capillary electrochromatography column in capillary electrochromatography.  相似文献   

5.
Qin S  Zhou C  Zhu Y  Ren Z  Zhang L  Fu H  Zhang W 《色谱》2011,29(9):942-946
将表面分别被改性成C18和氨基的磁性纳米颗粒按照不同比例混合,制备成具有不同分离选择性的混合固定相,进一步采用动态磁涂覆的方法制备开管毛细管电色谱柱。通过考察这种色谱柱中不同种类固定相表面物理化学性质对电渗流的综合影响,从理论上说明了其电渗流的特征。分别在不同固定相配比及不同涂覆长度条件下进行实验,理论与实验结果相符,证实通过调节固定相配比或磁铁对数可以便捷地调节电渗流的大小。  相似文献   

6.
Zhu Y  Zhou C  Qin S  Ren Z  Zhang L  Fu H  Zhang W 《Electrophoresis》2012,33(2):340-347
A novel open‐tubular capillary electrochromatography (OT‐CEC) with modified core/shell magnetic nanoparticles coating as stationary phase was introduced using external magnetic force to fix magnetic nanoparticles. The magnetic nanoparticles coating inside the capillary columns could be easily regenerated by removing and re‐applying the external magnetic field. Magnetic field intensity, concentration and flow rate of nanoparticles suspension were investigated to achieve simple and stable preparation. Mixture of five organic acids was used as the marker sample to evaluate the OT‐CEC system, and the relative column efficiency of anthranilic acid reaches 220 000 plates/m. The excellent within‐column and between‐column repeatability has been testified with the RSDs of retention time of less than 1.51 and 5.29%, respectively. The aqueous extract of rhizoma gastrodiae was analyzed by the OT‐CEC system, and 23 peaks were eluted in 30 min. Compared with conventional open‐tubular capillary column, this new system shows faster separation speed and higher column efficiency from the larger surface area of nanoparticles. It has great potential in the method development for the analysis of complex samples, since magnetic coating can effectively prolong the column life by expediently replacing stationary phase to eliminate the pollution or irreversible adsorption.  相似文献   

7.
Xu L  Sun Y 《Journal of chromatography. A》2008,1183(1-2):129-134
The use of a phenylalanine (Phe) functionalized tentacle-type polymer coated capillary column for protein separation by open tubular capillary electrochromatography (OTCEC) was demonstrated in this work. The tentacle-type stationary phase was prepared from silanized fused-silica capillaries of 50 microm I.D. by glycidyl methacrylate graft polymerization and subsequent Phe functionalization. Due to the amphoteric functional groups of the Phe bonded on the tentacle-type polymer stationary phase, protein separation in the prepared column can be performed under both cathodic and anodic electroosmotic flow (EOF) by varying the pH values of the mobile phase. Model proteins including ribonuclease A (RNase A), myoglobin, transferrin, insulin were baseline separated under cathodic EOF with a mobile phase of pH 8.8. Comparison between the separation result of the four proteins under conditions of OTCEC and capillary zone electrophoresis indicates that the migration behavior of the four proteins in the prepared column was the result of the interplay of chromatographic retention and electrophoretic migration. Besides, three basic proteins including RNase A, cytochrome c (Cyt-c) and lysozyme (Lys) were fully resolved under anodic EOF with an acidic running buffer (pH 2.5). The elution order was the same as the isoelectric point values of the proteins (RNase A相似文献   

8.
Huang HY  Chiu CW  Huang IY  Yeh JM 《Electrophoresis》2004,25(18-19):3237-3246
Five common food preservatives were analyzed by capillary electrochromatography, utilizing a methacrylate ester-based monolithic capillary as separation column. In order to optimize the separation of these preservatives, the effects of the pore size of the polymeric stationary phase, the pH and composition of the mobile phase on separation were examined. For all analytes, it was found that an increase in pore size caused a reduction in retention time. However, separation performances were greatly improved in monolithic columns with smaller pore sizes. The pH of the mobile phase had little influence on separation resolution, but a dramatic effect on the amount of sample that was needed to be electrokinetically injected into the monolithic column. In addition, the retention behaviors of these analytes were strongly influenced by the level of acetonitrile in the mobile phase. An optimal separation of the five preservatives was obtained within 7.0 min with a pH 3.0 mobile phase composed of phosphate buffer and acetonitrile 35:65 v/v. Finally, preservatives in real commercial products, including cold syrup, lotion, wine, and soy sauces, were successfully determined by the methacrylate ester-based polymeric monolithic column under this optimized condition.  相似文献   

9.
Poly(styrene-divinylbenzene) encapsulated silica (PS-DES) was synthesized and its characteristics as capillary electrochromatography stationary phase were studied. On capillary columns packed with this stationary phase, the effects of acetonitrile concentration as well as pH values on electroosmotic flow, and the effect of the latter on column efficiency were evaluated. Aromatic hydrocarbons, polar and basic medicinal compounds were successfully separated by using reversed-phase elution. It was evident that selectivity based on pi-pi electronic interaction between solute and stationary phase molecules contributed to the separation. Peaks in the chromatograms obtained were generally symmetrical. At a pH of the mobile phase as high as 11.2, the stationary phase was still stable after more than 160 h of exposure.  相似文献   

10.
Ye F  Xie Z  Wu X  Lin X  Chen G 《Journal of chromatography. A》2006,1117(2):170-175
A novel stationary phase phenylaminopropyl silica (PhA-silica) monolith was successfully prepared for pressure assisted capillary electrochromatography (pCEC). The monolithic silica matrix from a sol-gel process was chemically modified by using [3-(phenylamino)propyl]trimethoxysilane as surface modification reagent to produce the phenylaminoporpyl function. The secondary amino groups on the surface of the monolithic stationary phase contributed to the generation of anodic electroosmotic flow (EOF) under acidic conditions. The phenyl group together with the spacer (-(CH(2))(3)-) in PhA-silica provides sufficient hydrophobic properties. To evaluate the column performance, effects of buffer pH and mobile phase composition on the mobile phase linear velocity and the retention factors of alkylbenzenes, phenols and anilines were investigated in pCEC mode. The monolithic stationary phases exhibit typical reversed-phase (RP) electrochromatographic behavior toward neutral solutes. Hydrophobic as well as electrophoretic migration process within the monoliths was observed for the separation of basic solutes such as anilines without peak tailing.  相似文献   

11.
赵震震  瞿其曙  张欣欣  谷雪  王彦  阎超 《色谱》2009,27(4):431-435
制备了用于色谱的微米纯金颗粒并键合上十八烷基(C18)官能团;对其进行了扫描电镜、红外光谱、元素分析、氮气吸附分析等表征。测得衍生的金颗粒的粒径、孔径以及比表面积分别为3.5 μm、5.0 nm、49.0 m2/g;红外光谱表明C18官能团已键合在金颗粒表面上;衍生后的金颗粒的含碳量为0.56%。通过电填充法得到长度为36 cm(固定相填充长度为19 cm)、内径为100 μm的毛细管色谱柱。利用极端pH的流动相(80%甲醇,pH 1.0以及pH 12.0)冲洗该色谱柱140 h,比较冲洗前后分析物的保留因子,以考察色谱柱的耐酸耐碱性能。结果表明,冲洗前后分析物的保留因子没有明显的变化,说明该色谱柱有良好的耐酸耐碱性。在毛细管液相色谱模式下,用该柱分离尿嘧啶、苯、萘、2-甲基萘、苊以评价色谱柱的一般性能;在碱性条件下分离咖啡因、茶碱、洛贝林以测定色谱柱分离碱性物质的能力。其分离结果表明,该色谱柱的柱效超过了50000理论塔板/m,且色谱峰形较好。在毛细管加压电色谱模式下,施加+5 kV和~5 kV的电压均可以使苯甲酸和苯胺分离,但电场方向不同时,二者的出峰顺序不同。  相似文献   

12.
A novel monolithic silica column with zwitterionic stationary phase was prepared by in-situ covalent attachment of phenylalanine to a 3-glycidoxypropyltriethoxysilane-modified silica monolith. Due to the zwitterionic nature of the resulting stationary phase, the density and sign of the net surface charge, and accordingly the direction and magnitude of electroosmotic flow in this column during capillary electrochromatography could be manipulated by adjusting the pH values of the mobile phase. CEC separations of various acidic and basic compounds were performed on the prepared column in anodic and weakly cathodic EOF modes, respectively. The peak tailing of basic compounds in CEC on a silica column could be alleviated at optimized buffer compositions. Besides the electrophoretic mechanism and weak hydrophobic interaction, weak cation- and anion-exchange interactions are also involved in the separations of acids and bases, respectively, on the zwitterionic column.  相似文献   

13.
A capillary electrochromatographic (CEC) method was applied to the simultaneous separation of barbiturates (barbital, phenobarbital, secobarbital and thiopental) and benzodiazepines (nitrazepam, diazepam and triazolam). The separation was performed in a 75 microm i.d. capillary, packed with 3-(1,8-naphthalimido)propyl-modified silyl silica gel (NAIP), studying the effects of buffer pH and mobile phase composition. Using an applied voltage of 20 kV and the short-end injection method (9 cm capillary effective length), the mobile phase of 1.0 mM citrate buffer (pH 5.0) containing 45% methanol provided the baseline separation of seven toxic drugs in less than 9 min. In CEC with NAIP, the benzodiazepines were separated by the combination of hydrophobic and pi-pi interactions, whereas the separation of the barbiturates was based on the hydrophobic interaction.  相似文献   

14.
《Electrophoresis》2018,39(7):941-947
In this paper, β‐cyclodextrin (β‐CD) modified gold nanoparticles (AuNPs) coated open tubular column (OT column) was prepared for capillary electrochromatography. The open tubular column was constructed through self‐assembly of gold nanoparticles on 3‐mercaptopropyl‐trimethoxysilane (MPTMS) prederivatized capillary and subsequent modification of thiols β‐cyclodextrin (SH‐β‐CD). Scanning electron microscopy (SEM), transmission electron microscopy (TEM) and ultraviolet visible spectroscopy were carried out to characterize the prepared open tubular column and synthesized gold nanoparticles. By comparing different coating times of gold nanoparticles and thiols β‐cyclodextrin, we got the optimal conditions for preparing the open tubular column. Also, the separation parameters were optimized including buffer pH, buffer concentration and applied voltage. Separation effectiveness of open tubular column was verified by the separation of four pairs of drug enantiomers including bifonazole, fexofenadine, omeprazole and lansoprazole, and satisfactory separation results were achieved for these analytes studied. In addition, the column showed good stability and repeatability. The relative standard deviation values less than 5% were obtained through intra‐day, inter‐day, and column‐to‐column investigations.  相似文献   

15.
Kang J  Wistuba D  Schurig V 《Electrophoresis》2002,23(7-8):1116-1120
A method for the preparation of a silica monolithic capillary electrochromatography (CEC) column for the separation of enantiomers has been developed. The porous silica monolith was fabricated inside a fused-silica capillary column by using the sol-gel process. After gelation for 24 h, hydrothermal treatment at 100 degrees C for 24 h was performed to prevent the sol-gel matrix from cracking. The prepared monolith was then coated with Chirasil-beta-Dex which represents a chiral polymer prepared by grafting permethyl-beta-cyclodextrin to polymethylsiloxane with an octamethylene spacer. Immobilization of Chirasil-beta-Dex was performed by heat treatment at 120 degrees C for 48 h to give a nonextractable coating. The column performance was evaluated by using racemic hexobarbital as a model compound. The efficiency of 9.2 x 10(4) theoretical plates/m for the first eluted enantiomer of hexobarbital was obtained at an optimal flow rate of the mobile phase. The effect of mobile phase composition on enantiomeric separation of hexobarbital was also investigated. The column proved to be stable for more than one hundreds of runs during a two-months period. The enantiomers of several neutral and negatively charged chiral compounds were baseline separated on this column.  相似文献   

16.
Hsieh YL  Chen TH  Liu CP  Liu CY 《Electrophoresis》2005,26(21):4089-4097
A novel column made through the condensation reaction of TiO2 nanoparticles (TiO2 NPs) with silanol groups of the fused-silica capillary is described. EOF measurements under various buffer constitutions were used to monitor the completion of reactions. The results indicated that the EOF was dependent on the interactions between buffers and the bonded TiO2 NPs. With formate/Tris buffer, EOF reversal at pH below 5 and cathodic EOF at pH above 5 were indicated. The pI of the bonded TiO2 NPs was found at approximately ph 5. Only cathodic EOF was illustrated by substituting the mobile phase with either glutamate or phosphate buffer. It was elucidated that both glutamate and phosphate buffer yield a negative charge layer on the surface of TiO2 NPs attributable to the formation of a titanium complex. The CEC performance of the column was tested with angiotensin-type oligopeptides. Some parameters that would affect the retention behavior were investigated. The interactions between the bonded phases and the analytes were explicated by epitomized acid-base functional groups of the oligopepetides and the speciation of the surface oxide in different pH ranges. The average separation efficiencies of 3.1 x 10(4) plates/m is readily achieved with a column of 70 cm (50 cm) x 50 mum ID under an applied voltage of 15 kV, phosphate buffer (pH 6.0, 40 mM), and UV detection at 214 nm.  相似文献   

17.
A new type of capillary column for open-tubular electrochromatography   总被引:1,自引:0,他引:1  
Zhao Y  Zhao R  Shangguan D  Liu G 《Electrophoresis》2002,23(17):2990-2995
A new type of open-tubular C(18) ester-bonded electrochromatographic column was prepared with sol-gel technology, followed by an on-column octadecyl silylation reaction. Glycidoxypropyltrimethoxysilane, a widely used and important silane agent, was used as the sol-gel precursor to form a thin coating layer on the wall of the fused-silica capillary. The C(18) groups were introduced into the coating layer by on-column esterification reaction with stearic acid. The electrochromatography behavior of the column was evaluated in terms of the separation of peptides. A high efficiency of 4.8x10(5) plates/m was achieved for a basic pentapeptide using the C(18 )ester-bonded column. In comparison with bare capillaries and glycidoxypropyltrimethoxysilane sol-gel-coated capillaries, the C(18) ester-bonded column showed the best separation of a mixture of seven pentapeptides under identical conditions of buffer, pH, and applied voltage.  相似文献   

18.
Microemulsion electrokinetic chromatography (MEEKC) coupled with a diode-array detector was developed for the simultaneous analysis of natural steroidal compounds, withanolides including withaferin A, withacnistin and iochromolide. Optimal resolution was obtained with a microemulsion consisting of 70 mM octane, 800 mM 1-butanol, 100 mM sodium dodecyl sulfate (SDS), and 10 mM phosphate-borate buffer (pH 7) using a fused-silica capillary at 25 kV and 40 degrees C. Since this technique is not compatible with mass spectrometry detection, a capillary electrochromatographic method was developed to separate the investigated withanolides. The effects of mobile phase composition and pH were systematically investigated. Complete separation was obtained with a capillary electrochromatography (CEC) Hypersil C18 bonded silica column (packed length, 25 cmx100 microm ID and 375 microm OD), packed with 3 microm particles. The mobile phase consisted of formic acid-ammonia, pH 8 / acetonitrile (40/60 v/v); the voltage was set at 25 kV and the temperature at 20 degrees C. Under these conditions, resolution of these closely related compounds, including the critical pair withacnistin and iochromolide, was achieved in less than 5 min. The separations by MEEKC and CEC were compared with that obtained by reversed-phase liquid chromatography and showed similar retention order, indicating the analogy of the retention mechanism of these techniques. To further improve specificity and sensitivity, the developed CEC method was interfaced with electrospray ionization mass spectrometry using a Teflon connection between the CEC column and a void fused-silica capillary. Finally, the described methods were applied to the qualitative analysis of withanolides in Iochroma gesnerioides plant extract.  相似文献   

19.
A neutral, nonpolar monolithic capillary column was evaluated as a hydrophobic stationary phase in pressurized CEC system for neutral, acidic and basic solutes. The monolith was prepared by in situ copolymerization of octadecyl methacrylate and ethylene dimethacrylate in a binary porogenic solvent consisting of cyclohexanol/1,4‐butanediol. EOF in this hydrophobic monolithic column was poor; even the pH value of the mobile phase was high. Because of the absence of fixed charges, the monolithic capillary column was free of electrostatic interactions with charged solutes. Separations of neutral solutes were based on the hydrophobic mechanism with the pressure as the driving force. The acidic and basic solutes were separated under pressurized CEC mode with the pressure and electrophoretic mobility as the driving force. The separation selectivity of charged solutes were based on their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase, and no obvious peak tailing for basic analytes was observed. Effects of the mobile phase compositions on the retention of acidic compounds were also investigated. Under optimized conditions, high plate counts reaching 82 000 plates/m for neutral compounds, 134 000 plates/m for acid compounds and 150 000 plates/m for basic compounds were readily obtained.  相似文献   

20.
瞿其曙  周瑜  彭生微  胡效亚  阎超 《色谱》2010,28(3):260-263
制备了1 μm无孔硅胶颗粒。通过电动填充法得到总长度为45 cm(固定相填充长度为20 cm)、内径为100 μm的毛细管色谱柱。以乙腈-水体系作为流动相,详细考察了碱性化合物在该色谱柱上的加压电色谱(pCEC)分离性能,讨论了流动相比例、缓冲液浓度、pH值及操作电压等因素对分离的影响。实验结果表明,裸硅胶柱在乙腈-水体系分离碱性样品中表现出典型的反相色谱分离性能;缓冲液浓度的改变则对分离影响不大。当pH值改变时,碱性化合物的解离程度发生变化,它们与固定相之间的作用力发生变化,使得分离度发生相应的变化。分离柱效随施加电压的增加而增加,在1 kV电压下,裸硅胶柱对邻甲苯胺的柱效为35000理论塔板/m。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号