首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Antibody-based therapeutic agents and other biopharmaceuticals are now used in the treatment of many diseases. However, when these biopharmaceuticals are administrated to patients, an immune reaction may occur that can reduce the drug's efficacy and lead to adverse side-effects. The immunogenicity of biopharmaceuticals can be evaluated by detecting and measuring antibodies that have been produced against these drugs, or antidrug antibodies. Methods for antidrug antibody detection and analysis can be important during the selection of a therapeutic approach based on such drugs and is crucial when developing and testing new biopharmaceuticals. This review examines approaches that have been used for antidrug antibody detection, measurement, and characterization. Many of these approaches are based on immunoassays and antigen binding tests, including homogeneous mobility shift assays. Other techniques that have been used for the analysis of antidrug antibodies are capillary electrophoresis, reporter gene assays, surface plasmon resonance spectroscopy, and liquid chromatography-mass spectrometry. The general principles of each approach will be discussed, along with their recent applications with regards to antidrug antibody analysis.  相似文献   

2.
Moser AC  Hage DS 《Electrophoresis》2008,29(16):3279-3295
The use of CE as a tool to conduct immunoassays has been an area of increasing interest over the last decade. This approach combines the efficiency, small sample requirements, and relatively high speed of CE with the selectivity of antibodies as binding agents. This review examines the various assay formats and detection modes that have been reported for these assays, along with some representative applications. Most CE immunoassays in the past have employed homogeneous methods in which the sample and reagents are allowed to react in solution. These homogeneous methods have been conducted as both competitive binding immunoassays and as noncompetitive binding immunoassays. Fluorescent labels are most commonly used for detection in these assays, but enzyme labels have also been utilized for such work. Some additional work has been performed in CE immunoassays with heterogeneous methods in which either antibodies or an analog of the analyte is immobilized to a solid support. These heterogeneous methods can be used for the selective isolation of analytes prior to their separation by CE or to remove a given species from a sample/reagent mixture prior to analysis by CE. These CE immunoassays can be used with a variety of detection modes, such as fluorescence, UV/Vis absorbance, chemiluminescence, electrochemical measurements, MS, and surface plasmon resonance.  相似文献   

3.
The development of express method for detection of endocrine-disrupting chemicals (EDC) such as alkylphenols is required for ecological monitoring. Several attempts have been made to produce antibodies against 4-nonylphenol (NP) in recent years. This work describes the production of new antibodies against NP and also summarizes the characterization of antibodies obtained earlier. Three approaches used to produce alkylphenol-specific antibodies are compared; these are based on: 1. omega-(4-hydroxyphenyl)nonanoic or omega-(4-hydroxyphenyl)heptanoic acid NP derivatives designed to mimic the linear NP isomer; 2. 4-aminophenol, which potentially mimics various substituted phenolic compounds with different side-chain structures at position 4 of the benzene ring; and 3. a mixture of branched NP isomers, conjugated to the carrier protein via a benzene ring by the Mannich reaction, and expected to be the closest mimic of NP structure by preserving its natural alkyl moiety.Fluorescence polarization immunoassays based on different combinations of antibody and labeled antigen for screening detection of NP were developed and structural aspects of assay sensitivity and specificity were investigated. The assays based on the antisera raised against omega-(4-hydroxyphenyl)nonanoic acid and NP conjugate via Mannich reaction are capable of express detection of NP with detection limit of 7 microg mL(-1 )and assay dynamic range of 18-300 microg mL(-1).  相似文献   

4.
An optical biosensor was used to develop both direct and sandwich immunoassays for the detection of proteins from milk, egg, hazelnut, peanut, shellfish, and sesame in food samples. Affinity-purified polyclonal antibodies raised against the proteins were immobilized on the biosensor chip. Food samples were injected and the proteins that bound to the antibodies on the surface were detected by a shift in the resonance angle. By adding a second antibody in a sandwich assay, matrix effects could be overcome and the sensitivity and selectivity enhanced. Detection of allergen levels down to 1-12.5 microg/g in food samples was demonstrated for the various assays. Good agreement of results was also obtained from parallel analysis with alternative immunoassays, including rocket immunoelectrophoresis, enzyme immunoassay, and immunoblotting. The present study demonstrates that the sensitivity of the described biosensor technique is comparable to the most sensitive enzymed-linked immunosorbent assays.  相似文献   

5.
Chen CS  Baeumner AJ  Durst RA 《Talanta》2005,67(1):205-211
To improve the antigen-binding activity of liposome-coupled antibodies and to develop universal liposomal nanovesicles for immunoassays, protein G was conjugated to dye-loaded liposomal nanovesicles for the preparation of immunoliposomes. Sulfosuccinimidyl-4-(N-maleimidomethyl) cyclohexane-1-carboxylate (sulfo-SMCC), a heterobifunctional cross-linker, was used to modify protein G for conjugation to the liposomal nanovesicles. Liposome immunosorbent assays were used to evaluate the binding ability of protein G after sulfo-SMCC modification, to optimize the protein G density on the liposome surface and to determine the amount of IgG binding to the protein G-liposomal nanovesicles. Test strips coated with a narrow zone of antibodies were used to show the successful conjugation. Immunomagnetic beads were used to demonstrate the feasibility of protein G-tagged universal liposomal nanovesicles for immunoassays. Results indicate that the Fc-binding capacity of protein G decreased by only 5.3% after sulfo-SMCC modification. Antibodies were easily conjugated to universal protein G-liposomal nanovesicles in 30 min. The conjugates (protein G-immunoliposomes) were successfully used in immunomagnetic bead assays for the detection of Escherichia coli O157:H7 with a detection limit of approximately 100 CFU/ml. This work demonstrated that protein G-liposomal nanovesicles are a successful universal reagent for easily coupling antibodies in an active orientation on the liposome surface for use in immunoassays.  相似文献   

6.
We report on a lateral flow microarray that combines multi-spot immunochip technology and immunochromatography. It can serve as a tool for the simultaneous detection of multiple analytes. The test zone of the nitrocellulose support comprises a microarray spotted with up to 32 antigens that can capture labeled gold-antibodies after lateral flow. The detection limits and detectable concentration ranges of the assay were characterized. The method was applied to the determination of drugs of abuse (and their metabolites) in urine, specifically of morphine, amphetamine, methamphetamine, and benzoylecgonine. The assay format is rapid (10 min), and has both a low relative standard deviation (< 9 %) and high recoveries (95–114 %). The detection limits (2–20 ng mL–1 for drugs of abuse) are comparable to those of conventional single-analyte strip methods.
Figure
Lateral flow microarray for simultaneous express detection of numerous compounds and its comparison with traditional lateral flow tests  相似文献   

7.
Protein assays provide direct access to biologically and pharmacologically relevant information. To obtain a maximum of information from the very smallest amounts of complex biological samples, highly multiplexed protein assays are needed. However, at present, cross-reactions of binding reagents restrict the use of such assays to selected cases and severely limit the potential for up-scaling the technology. Here we describe a double-chip format, which can effectively overcome this specificity problem for sandwich immunoassays. This format consists of a capture array and a reference array with fluorescent labeled detection antibodies coupled to the reference array via DNA duplexes. This format allows for the local application of the labeled detection antibodies onto their corresponding specific spots on the capture array. Here we show that this double-chip format allows for the use of cross-reactive antibodies without generating false positive signals, and an assay for the parallel detection of seven different cytokines was set up. Even without further optimization, the dynamic range and the limit of detection for interleukin 8 were found to be comparable to those obtained with other types of multiplexed sandwich immunoassays.  相似文献   

8.
We present a multiplex detection platform based on a microfluidic microparticle array to detect proteins and glucose in serum simultaneously. Multiplex detection of proteins and glucose was performed using biofunctionalized microparticles arrayed on gel-based microstructures integrated in microfluidics. The microparticles immobilized on these microstructures showed high stability under microfluidic flow conditions. With arrays of antibody-coated microbeads, microfluidic quantitative immunoassays for two protein tumor markers, human chorionic gonadotropin (hCG) and prostate specific antigen (PSA) were performed in serum samples with detection limits bellow the cut-off values for cancer diagnosis. Parallel to the immunoassays, quantitative enzymatic assays for glucose in the physiological concentration range were performed. Multiplex detection was achieved by using a spatially encoded microarray. By patterning antibody-coated microbeads and enzyme-containing microparticles on a novel mixed structure array, we successfully demonstrated simultaneous immunoassays (binding based assay) for proteins and an enzymatic assay (reaction kinetic based assay) for glucose. Our microparticle arrays could be potentially used for the detection of multiple categories of biomolecules (proteins, small metabolites and DNA) for clinical diagnostics and other biological applications.  相似文献   

9.
Immunoassays for aflatoxins   总被引:3,自引:0,他引:3  
Immunoassays for aflatoxin analysis have been regarded as valuable supplements to existing and rapidly developing chromatographic techniques. We describe six types of aflatoxin immunogens and their characteristics, reported antibodies against aflatoxins, traditional and novel labeled materials for assay signaling, three immunoassay formats, assay devices (e.g., microtiter plate and reader, lateral flow strip, electronic and optical immunosensors, and a rapid tester dedicated to aflatoxins) and applications of immunoassay in agricultural products. We show trends towards sensitivity, simplification, intelligence and portability. After setting out five challenges in developing immunoassays, we predict that techniques involving novel nanoparticle labels and non-competitive assay may become the main trends in research and that immunoassay devices will be used in many fields.  相似文献   

10.
In the present study, new putative epitopes located in structural (E2) and non-structural (NS3) proteins of GBV-C/HGV were identified by computer-aided prediction of antigenicity and synthesized in solid-phase, following an Fmoc/tBut strategy, for their use in immunoassays. The corresponding synthetic peptides were used as antigens in ELISA assays and in real-time biospecific interaction measurements. This last approach allowed direct detection of GBV-C/HGV-specific antibodies in human sera. Good correlations were obtained between the biospecific interaction analysis and the ELISA. To verify the performance of these new assays in comparison to the existing recombinant E2 protein commercial test, antibodies to synthetic peptides were searched for in different panels of serum samples. The main conclusion of this work is the usefulness of E2 peptides in the detection of antibodies. Moreover, the NS3 peptide could be exploited to improve the sensitivity of the currently available test. Our results offer a new approach to develop new diagnostic peptide based biosensors for serodiagnosis of GBV-C/HGV infection.  相似文献   

11.
Aptamers are synthetic, relatively short (e.g., 20-80 bases) RNA or ssDNA oligonucleotides that can bind targets with high affinity and specificity, similar to antibodies, because they can fold into unique, three-dimensional shapes. For use in various assays and experiments, aptamers have been conjugated with biotin or digoxigenin to form complexes with avidin or anti-digoxigenin antibodies, respectively. In this study, we developed a method to label the 5'' ends of aptamers with cotinine, which allows formation of a stable complex with anti-cotinine antibodies for the purpose of providing another affinity unit for the application in biological assays using aptamers. To demonstrate the functionality of this affinity unit in biological assays, we utilized two well-known aptamers: AS1411, which binds nucleolin, and pegaptanib, which binds vascular endothelial growth factor. Cotinine-conjugated AS1411/anti-cotinine antibody complexes were successfully applied to immunoblot, immunoprecipitation, and flow cytometric analyses, and cotinine-conjugated pegaptanib/anti-cotinine antibody complexes were used successfully in enzyme immunoassays. Our results show that cotinine-conjugated aptamer/anti-cotinine antibody complexes are an effective alternative and complementary technique for aptamer use in multiple assays and experiments.  相似文献   

12.
Recent advances in analytical techniques have enabled the detection of drugs and drug metabolites in oral fluid specimens. Although GC–MS is still commonly used in practice, many laboratories have developed and successfully validated methods for LC–MS(–MS) that can detect a large number of compounds in the limited sample volume available. In addition, several enzyme immunoassays have been commercialized for the detection of drugs of abuse in oral fluid samples, enabling the fast screening and selection of presumably positive samples. A number of concerns are discussed, such as the variability in the volume of sample collected and its implications in terms of quantitative measurements, and the drug recoveries of the many different specimen collection systems on the market. Additional considerations that also receive attention are the importance of providing complete validation data with respect to analyte stability, matrix effect, and the choice of collection method.  相似文献   

13.
With the worldwide use of penicillin antibiotics comes the need for tighter controls. Bacterial resistance is a genuine problem and governmental and international bodies, for example the European Medicines Agency (EMA) and the World Health Organization (WHO), have designed strategies to overcome this unfortunate consequence of antibiotic use. Foodstuffs are monitored to ensure they contain very low quantities of antibiotics, so they are not prejudicial to health and the environment. Detection is based on chromatographic methods. However, screening can be performed by use of simpler, rapid methods of detection, e.g. microbial inhibition test, lateral flow assays, immunoassays, and use of biosensors, to reduce the final number of samples to be analyzed by chromatography. In this review, we have gathered information regarding all such screening methods for the penicillins and have critically assessed their capability and specificity for detection of penicillins.  相似文献   

14.
Kiening M  Niessner R  Weller MG 《The Analyst》2005,130(12):1580-1588
The selection of suitable antibodies is a critical step in immunoassay development, since the final assay performance is predetermined by this decision to a large extent. Particularly, the screening for matching pairs in sandwich immunoassays is difficult, if both antibodies are derived from one species or when monoclonal antibodies are only available as cell supernatants. Several microplate-based approaches for in situ labeling of detection antibodies were tested, in order to avoid time consuming purification of antibodies for enzyme conjugate synthesis. We investigated labeling with anti-species antibodies and Fab fragments thereof, labeling with protein G and biotinylation of cell supernatants without prior purification. Antibodies against peanut proteins were used as a model and signal-to-blank ratios were used in all cases as a measure of the antibody pair performance. Amongst the investigated approaches, preincubation of the detection antibody with labeled anti-species antibody turned out to be most suitable under our conditions. Diagrams, showing the performance of all possible antibody combinations, were generated with this method and were compared to results obtained with covalently labeled detection antibodies. Finally, a flowchart is presented, suggesting an efficient strategy for the development of highly sensitive sandwich immunoassays.  相似文献   

15.
Finding a general solution for optimizing the grafting of antibody on solid surfaces is difficult due to the variety of material, grafting principles and chemistries or surface formats available (beads, microplates, fibers, etc.). Pre-screening methods able to assess grafting efficiency (GE) and specific activity (SA) are required. In this context, we present here two colorimetric assays that can be used on a wide variety of surface format, chemistry, etc. The first one, ADECA (Amino Density Estimation by Colorimetric Assay) allows a rapid estimation of grafted antibodies and allows calculating the GE. The second one, A2HRP (Antibody Anti-HorseRadish Peroxidase) provides a measure of the amount of active antibody, which, combined to ADECA, is used to determine the SA of grafted antibody. Analytical parameters (limit of detection, repeatability, linearity, etc.) of these two colorimetric assays are presented. Using two commercially available microplates, we demonstrated that, when used in parallel, these rapid and sensitive methods are well adapted to pre-screening of antibody grafting performances.  相似文献   

16.
During the last decade, there has been a rapidly growing trend toward the use of cellphone-based devices (CBDs) in bioanalytical sciences. For example, they have been used for digital microscopy, cytometry, read-out of immunoassays and lateral flow tests, electrochemical and surface plasmon resonance based bio-sensing, colorimetric detection and healthcare monitoring, among others. Cellphone can be considered as one of the most prospective devices for the development of next-generation point-of-care (POC) diagnostics platforms, enabling mobile healthcare delivery and personalized medicine. With more than 6.5 billion cellphone subscribers worldwide and approximately 1.6 billion new devices being sold each year, cellphone technology is also creating new business and research opportunities. Many cellphone-based devices, such as those targeted for diabetic management, weight management, monitoring of blood pressure and pulse rate, have already become commercially-available in recent years. In addition to such monitoring platforms, several other CBDs are also being introduced, targeting e.g., microscopic imaging and sensing applications for medical diagnostics using novel computational algorithms and components already embedded on cellphones. This report aims to review these recent developments in CBDs for bioanalytical sciences along with some of the challenges involved and the future opportunities.
Figure
The universal Rapid Diagnostic Test (RDT) reader developed at UCLA. It can read various lateral flow assays for point-of-care and telemedicine applications  相似文献   

17.
This paper describes the original synthesis of a functionalized derivative of the fungicide picoxystrobin and the generation of the first reported monoclonal antibodies against this strobilurin pesticide. The synthetic hapten was prepared by total synthesis from commercial chemicals and incorporating the spacer arm through a carbon-carbon single bond. Also, to obtain the immunogen, an uncommon hapten activation strategy based on N,N'-disuccinimidyl carbonate was employed, affording high activation yields and clean and reproducible coupling results. With these immunoreagents, two enzyme-linked immunosorbent assays (ELISAs) were developed: a competitive one-step assay using the antibody-coated direct ELISA format and a competitive two-step assay with the conjugate-coated indirect ELISA procedure. Both immunoassays were characterized in terms of sensitivity, selectivity, tolerance to solvents and matrix effects, achieving limits of detection below 0.2 μgL(-1). The optimized assays were used for the determination of picoxystrobin residues in beer, with recovery values ranging between 90 and 121% for the direct assay and from 79 to 122% for the indirect assay.  相似文献   

18.
Antibody-based methods for surfactant screening   总被引:1,自引:0,他引:1  
This brief overview summarises the immunoassay-based results obtained in the course of two years of the European INCO-Copernicus project BIOTOOLS. The project is aimed at simplifying the procedures for detection of surface active compounds (SAC) using, among others, antibody-based methods, i.e., microtiter plate-based enzyme-linked immunosorbent assays (ELISA), polarisation fluoro immunoassays (PFIA), and enzyme flow injection immunoassays (FIIA). Thirty-three rabbits were immunised with five different sulphophenyl moieties and three p-hydroxyphenyl moieties conjugated to protein immunogens to produce analytical antibodies against linear alkylbenzene sulphonates (LAS) and nonylphenol (NP). Although most of the antibodies exhibited binding reaction in indirect ELISA, only a few showed the required assay sensitivity. The best antibodies for LAS exhibited a 50% binding inhibition at IC50 19.8 microg L(-1) in indirect ELISA. Similar inhibition was observed for direct ELISA using peroxidase tracers. Antibodies against NP allowed the establishment of an indirect assay operating in the mg L(-1) range. A rapid and simple protocol for the screening of NP and LAS using homogeneous PFIA is described. The assay time for 10 samples was 7 minutes, thus allowing fast detection of the selected SAC at the mg L(-1) level. A generic competitive FIIA system, using a protein G column for separation of free and antibody-bound beta-galactosidase (beta-Gal) tracer, was developed for the screening of LAS, NP, and nonylphenol decaethoxylate (NPEO10). The FIIA had a sample throughput (STP) of 5-10 samples per hour, with limits of detection (LOD) for LAS, NP, and NPEO10 of 19.5, 52, and 2.4 microg L(-1), respectively. The developed FIIAs were applied to spiked rain and surface water.  相似文献   

19.
Enzyme-linked immunosorbent assays are routinely used in laboratories around the world and ensure highly specific protein detection. Often, more than one analyte needs to be determined in a single sample and numerous protein arrays for multianalyte detection of a single sample have been developed to address this problem. They have the potential to analyze several dozen or even more analytes in an assay volume of usually around 100 μL. However, due to the presence of numerous different antibodies, these multianalyte sandwich immunoassays suffer from undesired cross-reactivities between the antibodies which lead to a loss of assay specificities. Here, we present an assay principle which allows, e.g., a detection of an analyte in a sample volume of only 1 μL in a normal 96-microtiter well plate, so that up to 100 analytes can be determined from a 100 μL sample volume, but in separate wells. This eliminates antibody cross-reactivities. The assay is based on the biotinylated time-resolved fluorophore EuLH used as a PEG11-dye conjugate in combination with ExtrAvidin® to ensure high signal-to-background ratios. The model protein epidermal growth factor (EGF) was detected with the established sandwich immunoassay and showed assay parameters comparable to commercially available ones. Furthermore, the assay principle enables a spatial resolution of the assay signal. Here, we demonstrated the application of the new detection system for universal imaging-based analysis of individual spots in one single 96-microtiter well by applying it to multisample and also multianalyte detections. In the case of the multisample analysis approach, a considerable reduction of the required sample volume to only 1 μL in a single 96 microtiter well could be achieved.  相似文献   

20.
Today, immunoassays and several chromatographic methods are in use for drug screening in clinical and forensic toxicology and in doping control. For further proof of the authors’ new metabolite-based liquid chromatography-mass spectrometry (LC-MSn) screening concept, the detectability of drugs of abuse and their metabolites using this screening approach was studied. As previously reported, the corresponding reference library was built up with MS2 and MS3 wideband spectra using a LXQ linear ion trap with electrospray ionization in the positive mode and full scan information-dependent acquisition. In addition to the parent drug spectra recorded in methanolic solution, metabolite spectra were identified after protein precipitation of urine from rats after administration of the corresponding drugs and added to the library. This consists now of data of over 900 parent compounds, including 87 drugs of abuse, and of over 2,300 metabolites and artifacts, among them 436 of drugs of abuse. Recovery, process efficiency, matrix effects, and limits of detection for selected drugs of abuse were determined using spiked human urine, and the resulting data have been acceptable. Using two automatic data evaluation tools (ToxID and SmileMS), the intake of 54 of the studied drugs of abuse could be confirmed in urine samples of drug users after protein precipitation and LC separation. The following drugs classes were covered: stimulants, designer drugs, hallucinogens, (synthetic) cannabinoids, opioids, and selected benzodiazepines. The presented LC-MSn method complements the well-established gas chromatography-mass spectroscopy procedure in the authors’ laboratory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号