首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L−1 HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g−1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL−1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n = 8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.  相似文献   

2.
A new method that utilizes p-dimethylaminobenzaldehyde-modified nanometer SiO2 (SiO2-p-DMABD) as a solid phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). The preconcentration conditions of analytes were investigated, including the pH value, the shaking time, the mass of sorbent, the sample flow rate and volume, the elution condition and the interfering ions. The adsorption capacity of nanometer SiO2-p-DMABD was found to be (mg g− 1) Cr(III): 6.2, Cu(II): 18.6, Fe(III): 4.7 and Pb(II): 6.0 at pH 4. The adsorbed metals were quantitatively eluted with 4 mL of 1.0 mol L− 1 HCl. According to the definition of IUPAC, the detection limits (3σ) of this method for Cr(III), Cu(II), Fe(III) and Pb(II) were 0.79, 1.27, 0.40 and 1.79 ng mL− 1, respectively. The proposed method achieved satisfied results when it was applied to the determination of trace Cr(III), Cu(II), Fe(III) and Pb(II) in biological and water samples.  相似文献   

3.
Thiacalix[4]arenetetrasulfonate (TCAS) has been examined as a pre-column chelating reagent for the determination of trace metal ions by kinetic differentiation mode (KD) ion-pair reversed-phase high-performance liquid chromatography (HPLC) with spectrophotometric detection. Among 14 kinds of common metal ions tested here, viz. Al(III), Ca(II), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Hg(II), Mg(II), Mn(II), Ni(II), Pb(II), V(V), and Zn(II) ion, only Ni(II) ion was detected as the TCAS chelate in the HPLC separation stage in spite of TCAS forming the chelates with various metal ions except for Al(III), Ca(II), and Mg(II) at the pre-column chelation stage. The undetected metal-TCAS chelates seemed to be dissociated on an HPLC column where no added TCAS was present in the mobile phase because of their kinetic unstability. The calibration graph for Ni(II) ion gave a wide linear dynamic range (40-20,000 nM) with the very low detection limit (DL) (3σ base-line fluctuation) to be 5.4 nM (0.32 ng ml−1). The practical applicability of the KD-HPLC method with TCAS was demonstrated with the determination of trace Ni in coal fly ash.  相似文献   

4.
A new solid phase extractant, sinapinaldehyde (SA) modified SBA-15 mesoporous silica, was developed for selective extraction and preconcentration of trace Pb(II) from aqueous solutions. The successful immobilization of SA on SBA-15 and the strong interaction between SA-SBA-15 and Pb(II) were characterized and confirmed by FTIR spectroscopy and scanning electron microscopy. Parameters such as solution pH, shaking time, eluent condition and sample volume were optimized so that the maximum removal of Pb(II) from solution could be achieved. At pH 4.0, the maximum adsorption capacity of the sorbent for Pb(II) was found to be 33.6?mg?g?1 and the adsorbed Pb(II) could be completely eluted using a mixed solution of 2?M HCl and 5% CS(NH2)2. Some common metal ions such as K(I), Na(I), Mg(II), Ca(II), Cr(III), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II) did not interfere with the adsorption of trace Pb(II). The detection limit of the present method was found to be 1.3?ng?mL?1 and the relative standard deviation was less than 2.0% (n?=?8). These results suggested that this new sorbent is very efficient and selective for the removal of trace Pb(II) in water samples.  相似文献   

5.
Soliman EM  Saleh MB  Ahmed SA 《Talanta》2006,69(1):55-60
Dimethyl sulfoxide (DMSO) was simply immobilized to neutral alumina via quite strong hydrogen bonding between sulfoxide oxygen and surface alumina hydroxo groups. The produced alumina-modified dimethyl sulfoxide (AMDMSO) solid phase (SP)-extractor experienced high thermal and medium stability. Moreover, the small and compact size of DMSO moiety permit high surface coverage evaluated to be 2.1 ± 0.1 mmol g−1 of alumina. Hg(II) uptake was 1.90 mmol g−1(distribution coefficient log Kd = 5.658) at pH 1.0 or 2.0, 1.68 mmol g−1 (log Kd = 4.067) at pH 3.0 or 4.0 while the metal ions Ca(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Pb(II) showed low values 0.513-0.118 mmol g−1 (log Kd < 3.0) in the pH range 4.0-7.0. A mechanism was suggested to explain the unique uptake of Hg(II) ions by binding as neutral and chloroanionic species predominate at pH values ≤ 3.0 of a medium rich in chloride ions. A direct and fast batch separation mode was achieved successfully to retain selectively Hg(II) in presence of other eight coexisting metal ions. Thus, Hg(II) was completely retained; Ca(II), Co(II), Ni(II) and Cd(II) were not retained, while Pb(II), Cu(II), Zn(II) and Fe(III) exhibited very low percentage retention evaluated to be 0.42, 0.49, 1.4 and 5.43%, respectively. The utility of the new modified alumina sorbent for concentrating of ultratrace amounts of Hg(II) was performed by percolating 2 l of doubly distilled water, drinking tap water, and Nile river water spiked with 10 ng/l over 100 mg of the sorbent packed in a minicolumn used as a thin layer enrichment bed prior to the determination by CV-AAS. The high recovery values obtained (98.5 ± 0.5, 98.5 ± 0.5 and 103.0 ± 1.0) based on excellent enrichment factor 1000, along with a good precision (R.S.D.% 0.51-0.97%, N = 3) demonstrate the accuracy and validity of the new modified alumina sorbent for preconcentrating ultratrace amounts of Hg(II) with no matrix interference.  相似文献   

6.
Silica gel-bound amines phase modified with p-dimethylaminobenzaldehyde (p-DMABD) was prepared based on chemical immobilization technique. The product (SG-p-DMABD) was used as an adsorbent for the solid-phase extraction (SPE) Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The uptake behaviors of SG-p-DMABD for extracting these metal ions were studied using batch and column procedures. For the batch method, the optimum pH range for Cr(III) and Ni(II) extraction was ≥ 3, for Cu(II), Pb(II) and Zn(II) extraction it was ≥ 4. For simultaneous enrichment and determination of all the metals on the newly designed adsorbent, the pH value if 4.0 was selected. All the metal ions can be desorbed with 2.0 mL of 0.5 mol L− 1 of HCl. The results indicate that SG-p-DMABD has rapid adsorption kinetics using the batch method. The adsorption capacity for these metal ions is in the range of 0.40-1.15 mmol g− 1, with a high enrichment factor of 125. The presence of commonly coexisting ions does not affect the sorption capacities. The detection limits of the method were found to be 1.10, 0.69, 0.99, 1.10 and 6.50 μg L− 1 for Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 5.0% (n = 8) for all metal ions. The method was applied to the preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) from the certified reference material (GBW 08301, river sediment) and water samples with satisfactory results.  相似文献   

7.
It is the first time that triphenylmethane was used as an adsorbent to preconcentrate and separate trace amount of molybdenum in water samples. The effects of different parameters, such as acidity, stirring time and various metal ions, the amounts of triphenylmethane and salicyl fluorine, etc. on the enrichment yield of molybdenum have been studied to optimize the experimental conditions. Under the optimum conditions, molybdenum can be adsorbed on the surface of microcrystalline triphenylmethane loaded with salicyl fluorone by the intermolecular action strength. The possible reaction mechanism for the enrichment of molybdenum was discussed in detail in this paper. Mo(VI) can be completely separated from Pb(II), Co(II), Cu(II), Cr(III), Ni(II), Hg(II), Zn(II), Cd(II), Fe(III) and Al(III) in the solution. The proposed method was successfully applied to the determination of trace amount of molybdenum in various water samples by spectrophotometry after preconcentration using microcrystalline triphenylmethane. The preconcentration factor is from 83 (500 ml water sample was enriched to 6.0 ml) to 166 (1000 ml water sample was enriched to 6.0 ml). The detection limit is 1.3 × 10−5 mg l−1 and the linearity is maintained in the concentration range 3.8 × 10−3 to 0.36 mg l−1 with a correlation coefficient of 0.9998. The recoveries are in the range of 93.5-104%. The relative standard deviation is 1.8-2.9%. Analytical results obtained with this novel method are very satisfactory.  相似文献   

8.
Candir S  Narin I  Soylak M 《Talanta》2008,77(1):289-293
A cloud point extraction (CPE) procedure has been developed for the determination trace amounts of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions by using flame atomic absorption spectrometry. The proposed cloud point extraction method was based on cloud point extraction of analyte metal ions without ligand using Tween 80 as surfactant. The surfactant-rich phase was dissolved with 1.0 mL 1.0 mol L−1 HNO3 in methanol to decrease the viscosity. The analytical parameters were investigated such as pH, surfactant concentration, incubation temperature, and sample volume, etc. Accuracy of method was checked analysis by reference material and spiked samples. Developed method was applied to several matrices such as water, food and pharmaceutical samples. The detection limits of proposed method were calculated 2.8, 7.2, 0.4, 1.1, 0.8 and 1.7 μg L−1 for Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II), respectively.  相似文献   

9.
Zhifeng Tu  Lijun Zhang  Qun He  Jianping Shi  Ru Gao 《Talanta》2010,80(3):1205-1747
A new method that utilizes 1-(2-aminoethyl)-3-phenylurea-modified silica gel as a solid-phase extractant has been developed for preconcentration of trace Sc(III) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace level of Sc(III) were optimized using batch and column procedures in detail. The optimum pH value for the separation of Sc(III) on the new sorbent was 4 and complete elution of Sc(III) from the sorbent surface was carried out using 1.0 mL of 0.1 mol L−1 HCl. Common coexisting ions did not interfere with the separation and determination of the analyte. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 32.5 mg g−1 while the time of 95% adsorption was less than 2 min. The detection limit of present method was found to be 0.091 μg g−1, and the relative standard deviation (RSD) was lower than 3.0% (n = 8). The method was successfully applied for the preconcentration of trace Sc(III) in the environmental samples with satisfactory results.  相似文献   

10.
A new Fe(III)-imprinted amino-functionalized silica gel sorbent was prepared by a surface imprinting technique for selective solid-phase extraction (SPE) of Fe(III) prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Compared with non-imprinted polymer particles, the ion-imprinted polymers (IIPs) had higher selectivity and adsorption capacity for Fe(III). The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Fe(III) was 25.21 and 5.10 mg g−1, respectively. The largest selectivity coefficient of the Fe(III)-imprinted sorbent for Fe(III) in the presence of Cr(III) was over 450. The relatively selective factor (αr) values of Fe(III)/Cr(III) were 49.9 and 42.4, which were greater than 1. The distribution ratio (D) values of Fe(III)-imprinted polymers for Fe(III) were greatly larger than that for Cr(III). The detection limit (3σ) was 0.34 μg L−1. The relative standard deviation of the method was 1.50% for eight replicate determinations. The method was validated by analyzing two certified reference materials (GBW 08301 and GBW 08303), the results obtained is in good agreement with standard values. The developed method was also successfully applied to the determination of trace iron in plants and water samples with satisfactory results.  相似文献   

11.
Huang MR  Rao XW  Li XG  Ding YB 《Talanta》2011,85(3):1575-1584
A novel membrane electrode for Pb(II) ion detection based on semi-conducting poly(m-phenylenediamine) microparticles as a unique solid ionophore was fabricated. The electrode exhibited significantly enhanced response towards Pb(II) over the concentration range from 3.16 × 10−6 to 0.0316 M at pH 3.0-5.0 with a low detection limit of 6.31 × 10−7 M, a high sensitivity displaying a near-Nernstian slope of 29.8 mV decade−1 for Pb(II). The electrode showed a long lifetime of 5 months and a short response time of 14 s. A systematical investigation on the effect of anion excluder and various foreign ions on the selectivity of the electrode by a fixed interference method suggests that all other metal ions hardly ever interfere with the determination of Pb(II) except high concentration Hg(II). The electrode was successfully used as an indicator electrode in the potentiometric titration of Pb(II) with EDTA. Furthermore, the electrode has been used to satisfactorily analyze four types of real-world samples like spiked human urine, spiked tap water, and river water containing interfering ions like Na(I), Ca(II), Mg(II), Zn(II), Pd(II), Fe(III), K(I), Cu(II) and Hg(II) up to 8.04 × 10−4 M, demonstrating fast response, high selectivity, good recovery (96.6-121.4%), good repeatability (RSD 0.31-6.45%), and small relative error (5.0%).  相似文献   

12.
A new method that uses solid phase extraction (SPE) coupled with FTIR spectroscopy to detect Hg(II) in aqueous samples is described. The technique is envisioned for on-site, field evaluation rather than lab-based techniques. This paper presents the “proof of principle” of this new approach toward measurements of Hg(II) in water and identifies mass transport issues that would need to be overcome in order to migrate from a lab based method to field operation. The SPE material supported on a Si wafer is derivatized with an acylthiosemicarbazide, which undergoes a reaction in the presence of aqueous Hg(II) to form an oxadiazole ring. The progress of the reaction is monitored by IR spectroscopy. Following EPA guidelines, the method of detection limit (MDL) for the SPE/IR was 5 μg of Hg(II) cm−2. In a 1 L sample and a 1 cm2 Si wafer, this translates to a detection limit of 5 ppb. This system shows a high selectivity toward aqueous Hg(II) over other thiophilic heavy metal ions such as Pb(II), Cd(II), Fe(III), and Zn(II) and other metal ions such as Ni(II), Mn(II), Co(II), Cu(II), In(III), Ru(III), Na(I), and Ag(I) in aqueous solutions.  相似文献   

13.
Matsumiya H  Iki N  Miyano S 《Talanta》2004,62(2):337-342
Sulfonylcalix[4]arenetetrasulfonate (SO2CAS) has been examined as a pre-column chelating reagent for ultratrace determination of metal ions by ion-pair reversed-phase high-performance liquid chromatography with spectrophotometric detection. Metal ions were converted into the SO2CAS chelates in an acetic buffer solution (pH 4.7). The chelates were injected onto a n-octadecylsilanized silica-type Chromolith™ Performance RP-18e column and were eluted using a methanol (50 wt.%)-water eluent (pH 5.6) containing tetra-n-butylammonium bromide (7.0 mmol kg−1), acetate buffer (5.0 mmol kg−1), and disodium ethylendiamine-N,N,N′,N′-tetraacetate (0.10 mmol kg−1). Under the conditions used, Al(III), Fe(III), and Ti(IV) were selectively detected among 21 kinds of metal ions [Al(III), Ba(II), Be(II), Ca(II), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Ga(III), Hf(IV), In(III), Mg(II), Mn(II), Mo(VI), Ni(II), Pb(II), Ti(IV), V(V), Zn(II), and Zr(IV)]. The detection limits on a 3σ blank basis were 8.8 nmol dm−3 (0.24 ng cm−3) for Al(III), 7.6 nmol dm−3 (0.42 ng cm−3) for Fe(III), and 17 nmol dm−3 (0.80 ng cm−3) for Ti(IV). The practical applicability of the proposed method was checked using river and tap water samples.  相似文献   

14.
2-Thiophenecarboxaldhyde is chemically bonded to silica gel surface immobilized monoamine, ethylenediamine and diethylenetriamine by a simple Schiff’s base reaction to produce three new SP-extractors, phases (I-III). The selectivity properties of these phases toward Hg(II) uptake as well as eight other metal ions: Ca(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Pb(II) were extensively studied and evaluated as a function of pH of metal ion solution and equilibrium shaking time by the batch equilibrium technique. The data obtained clearly indicate that the new SP-extractors have the highest affinity for retention of Hg(II) ion. Their Hg(II) uptake in mmol g−1 and distribution coefficient as log Kd values are always higher than the uptake of any other metal ion along the range of pH used (pH 1.0-10.0). The uptake of Hg(II) using phase I was 2.0 mmol g−1 (log Kd 6.6) at pH 1.0 and 2.0. 1.8 mmol g−1 (log Kd 4.25), 1.6 mmol g−1 (log Kd 3.90) and 1.08 mmol g−1 (log Kd 3.37) at pH 3.0, 5.0 and 8.0, respectively. Selective separation of Hg(II) from the other eight coexisting metal ions under investigation was achieved successfully using phase I at pH 2.0 either under static or dynamic conditions. Hg(II) was completely retained while Ca(II), Co(II) and Cd(II) ions were not retained. Ni(II), Cu(II), Zn(II), Pb(II) and Fe(III) showed very low percentage retention values to be 0.74, 0.97, 3.5 and 6.3%, respectively. Moreover, the high recovery values (95.5 ± 0.5, 95.8 ± 0.5 and 99.0% ± 1.0) of percolating two liters of doubly distilled water, drinking tap water and Nile river water spiked with 5 ng/l of Hg(II) over 100 mg of phase I packed in a minicolumn and used as a thin layer enrichment bed demonstrate the accuracy and validity of the new SP-extractors for preconcentration of the ultratrace amount of spiked Hg(II) prior to the determination by borohydride generation atomic absorption spectrometry (AAS) with no matrix interference. The detection limit (3σ) for Hg(II) based on enrichment factor 1000 was 4.75 pg/ml. The precision (R.S.D.) obtained for different amounts of mercury was in the range 0.52-1.01% (N = 3) at the 25-100 ng/l level.  相似文献   

15.
The extraction of In(III) from HCl, H2SO4, and HNO3 media using a 0.20 mol l−1 Cyanex 923 solution in toluene is investigated. In(III) is quantitatively extracted over a fairly wide range of HCl molarity while from H2SO4 and HNO3 media the extraction is quantitative at low acid concentration. The extracted metal ion has been recovered by stripping with 1.0 mol l−1 H2SO4. The stoichiometry of the In(III): Cyanex 923 complex is observed to be 1:2. The extraction of In(III) is insignificantly changed in diluents namely toluene, n-hexane, kerosene (160-200 °C), cyclohexane, and xylene having more or less the same dielectric constants, whereas, it decreases with increasing polarity of diluents such as cyclohexanone and chloroform. The extractant is stable towards prolonged acid contact and there is a negligible loss in its extraction efficiency even after recycling for 20 times. The extraction behavior of some commonly associated metal ions namely V(IV), Ti(IV), Al(III), Cr(III), Fe(III), Ga(III), Sb(III), Tl(III), Mn(II), Fe(II), Cu(II), Zn(II), Cd(II), Pb(II), and Tl(I) has also been investigated. Based on the partition data the conditions have been identified for attaining some binary separations of In(III). These conditions are extended for the recovery of pure indium from zinc blend, zinc plating mud, and galena. The recovery of the metal ions is around 95% with purity approximately 99%.  相似文献   

16.
Jie Mao  Qun He  Weisheng Liu 《Talanta》2010,80(5):2093-432
An “off-on” rhodamine-based fluorescence probe for the selective signaling of Fe(III) has been designed exploiting the guest-induced structure transform mechanism. This system shows a sharp Fe(III)-selective fluorescence enhancement response in 100% aqueous system under physiological pH value and possesses high selectivity against the background of environmentally and biologically relevant metal ions including Al(III), Cd(II), Fe(II), Co(II), Cu(II), Ni(II), Zn(II), Mg(II), Ba(II), Pb(II), Na(I), and K(I). Under optimum conditions, the fluorescence intensity enhancement of this system is linearly proportional to Fe(III) concentration from 6.0 × 10−8 to 7.2 × 10−6 mol L−1 with a detection limit of 1.4 × 10−8 mol L−1.  相似文献   

17.
Chromium may exist in environmental waters as Cr(III) and Cr(IV), the latter being the toxic and carcinogenic form. Since atomic absorption spectrometry (AAS) and inductively coupled plasma atomic emission spectrometry can only yield information on total Cr concentration, a polymer resin bearing O,O-donor chelating groups such as the maleic acid-functionalized XAD(CO)CHCHCOOH resin was synthesized to selectively retain Cr(III) at pH 4.0-5.5. The dynamic breakthrough capacity of the resin for Cr(III) at pH 5.0 was 7.52 mg g−1, and the preconcentration factor extended to 250-300. Chromium(III) in the presence of 250-fold Cr(VI)—which was not retained—could be effectively preconcentrated on the NH4+-form of the resin and determined by AAS or diphenylcarbazide (DPC) spectrophotometry. When Cr(VI) was reduced to Cr(III) with Na2SO3 solution brought to pH 1 by the addition of 1 M H2SO4, and preconcentrated on the resin, total Cr could be determined. The developed method was validated with a blended coal sample CRM-1632. Since the adsorption behavior as a function of pH of possible interferent metal ions, e.g. Ni(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Fe(III), was similar to that of Cr(III), selective elution of Cr(III) from the resin was realized using a mixture of 1 wt.% H2O2+1 M NH3. The eluate containing Cr as chromate could be directly analyzed by diphenyl carbazide spectrophotometry without any adverse effect from the common interferents of this method, i.e. Fe(III), Cu(II) Hg(II), VO3, MoO42− and WO42−. Various synthetic waste solutions typical of electroplating bath effluents containing Cr, Cu, Ni, Zn, Na, Ca, cyanide (and chemical oxidation demand (COD), achieved by glucose addition) were subjected to pretreatment procedures such as hypochlorite oxidation (of cyanide) and catalytic oxidation (of COD) with peroxodisulfate. Chromium determination gave satisfactory results. The combined column preconcentration—selective elution—diphenylcarbazide spectrophotometric determination was also successfully applied to the determination of Cr in artificial and real seawater.  相似文献   

18.
The adsorption of cerium from aqueous solutions on lead dioxide has been investigated and optimized as a function of pH, equilibration time, sorbate and sorbent concentrations. The effect of other anions and cations on its adsorption has also been studied. Citrate, EDTA, tartrate, oxalate, U(VI), Th(IV), Pb(II), Cr(III) and Al(III) drastically reduce the adsorption. Adsorption of other metal ions on the same oxide has been measured under identical conditions. The distribution coefficient indicates that cerium can be separated from Fe(III), Tc(VII), In(III), Ag(I), Hg(II) and Ta(V). The data fitted very well to Freundlich as well as Dubinin-Raduskevich (D-R) isotherms. A mean free energy of sorption 11.62±0.2 kJ·mol–1 was calculated, using the D-R equation and corresponds to an ion exchange reaction.  相似文献   

19.
For the first time, the formation of a luminescent hexanuclear cluster has been used for the selective determination of copper. In aqueous solutions, the non-luminescent ligand N-ethyl-N′-methylsulfonylthiourea (EMT) forms an intensely red luminescent hexanuclear Cu(I)-cluster with an emission maximum at 663 nm only with Cu(II) ions. The intensity of the luminescence is proportional to the Cu(II) concentration and allows for selective Cu determinations in the μg l−1-range. Ubiquitous metal ions such as Fe(III), Al(III), Ca(II), Mg(II), and alkaline metal ions, as well as other heavy metal ions, e.g. Co(II), Ni(II), Zn(II), Cd(II), Hg(II), and Pb(II) are tolerated in concentrations up to 50 mg l−1. The detection limit for Cu(II) in aqueous solution, calculated according to Funk et al. [Qualitätssicherung in der Analytischen Chemie, Verlag Chemie, Weinheim, 1992], is 113 μg l−1. The cluster formation has been used for the quantitative analysis of copper in tap water and in industrial water, as well as for the localization of copper adsorbed by activated-sludge flocs.  相似文献   

20.
Silica gel was firstly functionalized with aminopropyltrimethoxysilane obtaining the aminopropylsilica gel (APSG). The APSG was reacted subsequently with curcumin yielding curcumin-bonded silica gel (curcumin-APSG). This new bonded silica gel was used for separation, pre-concentration and determination of Cu(II), Fe(III), Zn(II) in biological and natural water samples by inductively coupled plasma optical emission spectrometry (ICP-OES). Experimental conditions for effective adsorption of trace levels of metal ions were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the newly sorbent was 4.0. Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 2.0 mL of 0.1 mol L− 1 of HCl. Common coexisting ions did not interfere with the separation and determination at pH 4.0. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 0.63, 0.46 and 0.37 mmol g− 1 for Cu(II), Fe(III) and Zn(II) respectively. The time for 95% sorption for Cu(II) Fe(III) and Zn(II) was less than 2 min. The detection limits of the method defined by IUPAC was found to be 0.12, 0.15 and 0.40 ng mL− 1 for Cu(II), Fe(III) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was lower 3.0% (n = 5). The procedure was validated by analyzing the certified reference river sediment material (GBW 08301, China), the results obtained were in good agreement with standard values. This sorbent was successfully employed in the separation and pre-concentration of trace Cu(II), Fe(III) and Zn(II) from the biological and natural water samples yielding 75-fold concentration factor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号