首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
In recent years the number of environmental applications of elemental speciation analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. The analytical characteristics, such as extremely low detection limits (LOD) for almost all elements, the wide linear range, the possibility for multi-elemental analysis and the possibility to apply isotope dilution mass spectrometry (IDMS) make ICP-MS an attractive tool for elemental speciation analysis. Two methodological approaches, i.e. the combination of ICP-MS with high performance liquid chromatography (HPLC) and gas chromatography (GC), dominate the field. Besides the investigation of metals and metalloids and their species (e.g. Sn, Hg, As), representing “classic” elements in environmental science, more recently other elements (e.g. P, S, Br, I) amenable to ICP-MS determination were addressed. In addition, the introduction of isotope dilution analysis and the development of isotopically labeled species-specific standards have contributed to the success of ICP-MS in the field. The aim of this review is to summarize these developments and to highlight recent trends in the environmental application of ICP-MS coupled to GC and HPLC.  相似文献   

2.
Anion-exchange chromatography with inductively coupled plasma mass spectrometry (ICP-MS) is often used for the speciation of arsenic (As). In this work, either He or H2 was introduced to the octopole collision/reaction cell to eliminate chloride (Cl) interferences during As speciation by ICP-MS. Polyatomic species, 40Ar35Cl and 38Ar37Cl, which are formed in high chloride matrices interfere with the ICP-MS detection of 75As. These interferences were reduced or eliminated by introducing He or H2 to the collision/reaction cell, with some loss in sensitivity when compared to the standard mode (no gas). For example, the sensitivity of As(V) was 30.4 and 17.7% of that observed in standard mode when introducing He and H2, respectively. Chloride interference was completely eliminated using a flow rate of 3.0 mL min− 1 with H2 as a reaction gas with detection limits in the range of 0.3-0.6 μg L− 1. The developed method was applied to determination of arsenic species in waters containing high concentrations of chloride by following a simple procedure and without modification of the ICP-MS instrument.  相似文献   

3.
Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal operating characteristics of the entire hyphenated system. An isocratic HPLC system, which employs an aqueous mobile phase with organic buffer constituents, is well suited for introduction into the ICP-MS because of the stability of the detector response and high degree of analyte sensitivity attained. Anion and cation exchange HPLC systems, which meet these requirements, were used for the seperation of selenium and arsenic species in crude extracts of biological samples. Furthermore, the signal-to-noise ratios obtained for these incompletely ionized elements in the argon ICP were further enhanced by a factor of four by continously introducing carbon as methanol via the mobile phase into the ICP. Sources of error in the HPLC system (column overload), in the sample introduction system (memory by organic solvents) and in the ICP-MS (spectroscopic interferences) and their prevention are also discussed. The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic speciation in the shrimp sample. With this analytical technique the HPLC retention time in combination with mass analysis of the molecular ions and their collision-induced fragments provide almost conclusive evidence of the identity of the analyte species. The speciation methods are validated by establishing a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed.  相似文献   

4.
Method development and applications of hyphenated techniques as tools for speciation analysis of metal-based pharmaceuticals are summarized within this review. Advantages and limitations of the separation modes-high-performance liquid chromatography (HPLC), capillary electrophoresis (CE), and gas chromatography (GC)-as well as the detection modes-inductively coupled plasma-mass spectrometry (ICP-MS) and electrospray ionization-mass spectrometry (ESI-MS)-are discussed. ICP-MS detection is found to be advantageous for the quantification of drugs containing metals and other heteroatoms. The species-independent sensitivity and multielement capabilities of ICP-MS allow it to be used for quantification even when species-specific standards are not available, as well as to determine the stoichiometry in metallodrug-biomolecule interactions. Molecular information that is totally destroyed when ICP is applied as ionization source and is therefore not obtainable via ICP-MS detection can be accessed by the complementary technique of ESI-MS. Speciation analysis combining both elemental and molecular information is therefore a powerful tool for the analysis of metal-based pharmaceuticals and their metabolites in body fluids and other relevant matrices.  相似文献   

5.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of 3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300 W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover. Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in the plant sample.  相似文献   

6.

A method is presented for arsenic speciation analysis of an oyster sample using ion chromatography coupled with an inductively coupled plasma mass spectrometry (ICP-MS) instrument. A strong anion exchange resin was employed with a step gradient elution of 0.1 mM/0.1 M K 2 SO 4 at pH 10.2. Arsenobetaine and dimethylarsinic acid were determined following extraction based on trypsin enzymolysis with 95-100% extraction efficiency. Limits of detection in the range 0.1-0.3 mg kg m 1 of arsenic were obtained for organic arsenic species. No inorganic arsenic was detected. Validation was performed using TORT-2 as a certified reference material. Although high performance liquid chromatography (HPLC) coupled to ICP-MS is an effective method for speciation analysis it is not always necessary to obtain such a detailed picture. A simple liquid chromatographic separation technique based upon mini-column technology is presented. It was developed to obtain a fast, efficient and reliable separation of inorganic from organic, i.e. assumed toxic from non-toxic, arsenic and selenium species suitable for use as an initial screening method for environmental analysis. Two types of strong anion exchange resin were tested. Excellent separation was obtained for both min-column resins and analysis times were within 7 min. Limits of detection obtained for inorganic arsenic, organic arsenic, selenomethionine, Se IV and Se VI were 1.6, 1.8, 66, 32 and 22 µg kg m 1 , respectively.  相似文献   

7.
Donais MK  Henry R  Rettberg T 《Talanta》1999,49(5):3089-1050
The speciation of inorganic chromium in environmental samples is required for accurate assessment of pollution levels. Of the two chromium oxidation states, Cr (VI) is a known carcinogen, while Cr (III) is an essential element. Total chromium measurement cannot be used to determine actual environmental impact due to the considerable difference in toxicity of the two elemental forms. An automated liquid handling system, the PrepLab™, can be used with an inductively coupled plasma-mass spectrometer (ICP-MS) to quantify Cr (III) and Cr (VI) in liquid samples. An autosampler is used to introduce discrete sample volumes into a solid-phase chelation resin column. The Cr (III) and Cr (VI) species are separated and are introduced on-line into the VG PlasmaQuad 3 ICP-MS for detection. The chromatographic data are collected in time resolved analysis mode with the capability of simultaneous multiple-isotopic detection.  相似文献   

8.
An analytical procedure for selenium speciation of analysis of selenourea (SeU), selenoethionine (SeE), selenomethionine (SeM), Se(VI), Se(IV), dimethylselenide (dMeSe) and dimethyldiselenide (dMedSe) was developed, based on two complementary liquid chromatography (LC) techniques coupled with inductively coupled plasma-mass spectrometry (ICP-MS). Specifically, strong anion exchange (SAX) chromatography coupled with ICP-MS was used for the separation and quantification of all the earlier mentioned Se compounds, except for the two methyl selenides, which could be separated and determined by reversed phase chromatography coupled with ICP-MS. This procedure was applied to a soil sample from the warm springs area of Thermopyles (Greece). For leaching the Se species from the soil sample, four extraction methods, using water at ambient temperature, hot water, methanol and 0.5 M HCl, were tested for their efficiency of extracting the different Se species. The speciation results obtained by the LC-ICP-MS methods were compared with those obtained by voltammetric techniques. The determination of total selenium in the sample was achieved by graphite furnace atomic absorption spectrometry, as well as by ICP-atomic emission spectrometry, after suitable digestion of the sediment sample.  相似文献   

9.
In this study, selenium species from Se containing proteins in mushrooms (Agaricus bisporus and Lentinula edodes) were investigated with size-exclusion liquid chromatography coupled to UV and inductively coupled plasma mass spectrometry (ICP-MS). Different protein extraction protocols were investigated. Variability of the fractionation patterns with three extraction media (0.1M NaOH, 30 mM Tris-HCl, and enzymatic digestions) was evaluated for both mushroom types. A 24 h Tris-HCl extraction followed by acetone addition was found to be optimal for protein precipitation. Presumably protein bound selenoamino acids were released using enzymes (proteinase K, protease XIV and trypsin). The selenium speciation of the proteolytic extract of the water soluble proteins fraction was carried out by using reversed-phase ion-pairing high performance liquid chromatography (RP-HPIPC) coupled on-line to ICP-MS for selenium specific detection. Selenocystine, selenomethionine, methylselenocysteine and inorganic selenium were established in both samples utilizing retention time standards and standard additions to the sample.  相似文献   

10.
《Analytical letters》2012,45(9):1511-1523
Anion and cation exchange high-performance liquid chromatography (HPLC) combined with inductively coupled plasma-mass spectrometry (ICP-MS) were used for speciation of selenium in supplements. All the parameters in the extraction, separation, and determination procedures were optimized. Recovery studies for the selenium species from the anion and cation exchange columns were performed and there were no analyte losses. Limits of detection for selenium(IV), selenium(VI), Se in selenomethionine, and Se in selenocystine were 0.85, 0.68, 0.84, and 0.99 nanogram per milliliter, respectively. Six brands were analyzed to identify and quantify the selenium species present, and the results found were compared with the values given on the labels. The selenium species matched the labeled species for four brands, whereas two brands were found to contain inorganic Se(VI) in contrast with the labeled claim of selenomethionine.  相似文献   

11.
A new method for the simultaneous separation and determination of four arsenic species [As(III), As(V), monomethylarsonic acid and dimethylarsinic acid], three selenium species [Se(IV), Se(VI) and selenomethionine] as well as Sb(III) and Sb(V) is presented. The speciation was achieved by on-line coupling of anion exchange high-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). Chromatographic parameters such as the composition and pH of the mobile phase were optimised. Limits of detection are below 4.5 μg L–1 (as element) for Sb(III) and the selenium species and below 0.5 μg L–1 for the other species. Precisions of retention times were better than 2% RSD and of peak areas better than 8% RSD for all the species investigated.  相似文献   

12.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of 3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300 W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover. Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in the plant sample. Received: 4 September 1996 / Accepted: 12 December 1996  相似文献   

13.
Chen B  He M  Mao X  Cui R  Pang D  Hu B 《Talanta》2011,83(3):724-731
Room-temperature ionic liquids (RTILs) improved reversed-phase high performance liquid chromatography (RP-HPLC) on-line combined with inductively coupled plasma mass spectrometry (ICP-MS) was developed for selenium speciation. The different parameters affecting the retention behaviors of six target selenium species especially the effect of RTILs as mobile phase additives have been studied, it was found that the mobile phase consisting of 0.4% (v/v) 1-butyl-3-methylimidazolium chloride ([BMIM]Cl), 0.4% (v/v) 1-butyl-2,3-dimethylimidazolium tetrafluroborate ([BMMIM]BF4) and 99.2% (v/v) water has effectively improved the peak profile and six target selenium species including Na2SeO3 (Se(IV)), Na2SeO4 (Se(VI)), l-selenocystine (SeCys2), d,l-selenomethionine (SeMet), Se-methylseleno-l-cysteine (MeSeCys), seleno-d,l-ethionine (SeEt) were separated in 8 min. In order to validate the accuracy of the method, a Certified Reference Material of SELM-1 yeast sample was analyzed and the results obtained were in good agreement with the certified values. The developed method was also successfully applied to the speciation of selenium in Se-enriched yeasts and clover. For fresh Se-enriched yeast cells, it was found that the spiked SeCys2 in living yeast cells could be transformed into SeMet. Compared with other ion-pair RP-HPLC-ICP-MS approaches for selenium speciation, the proposed method possessed the advantages including ability to regulate the retention time of the target selenium species by selecting the suitable RTILs and their concentration, simplicity, rapidness and low injection volume, thus providing wide potential applications for elemental speciation in biological systems.  相似文献   

14.
Inductively coupled plasma-MS (ICP-MS) and its combined use with molecular mass spectrometric techniques have become the most promising detection techniques in speciation studies. High sensitivity and element specificity of ICP-MS has the advantage of detecting trace amounts of the species of interest in complex matrices. This review is divided into two parts. In the first part, suitable use of ICP-MS either online or offline with currently used separation techniques such as HPLC, CE, and gel electrophoresis in speciation analysis is briefly discussed. In the second part, recent applications (1999-2005) of phosphorus speciation is presented to elucidate the importance of ICP-MS in separation methods and to illustrate its importance in nonmetal detection.  相似文献   

15.
Enantioseparation and determination of selenomethionine enantiomers in selenized yeast was investigated using chiral separation techniques based on different principles, coupled on-line to inductively coupled plasma mass spectrometry (ICP-MS) for selenium-specific detection. High performance liquid chromatography (HPLC) on a beta-cyclodestrin (beta-CD) column, cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC), gas chromatography (GC) on a Chirasil-L-Val column, and HPLC on a Chirobiotic T column have been investigated as the chiral separation techniques. For HPLC separation on the beta-CD column, and also for CD-MEKC, selenomethionine enantiomers were derivatized with NDA/CN(-). For chiral separation by GC, selenomethionine enantiomers were converted into their N-trifluoroacetyl (TFA)-O-alkyl esters. The developed hybridation methodologies are compared with respect to enantioselectivity, sensitivity and analysis time. The usefulness of the best-suited method [HPLC (Chirobiotic T)-ICP-MS] was demonstrated by its application to the successful chiral speciation of selenium and D-and L-selenomethionine content determination in selenized yeast.  相似文献   

16.
The use of inductively coupled plasma mass spectrometry (ICP-MS) coupled with separation techniques for the purpose of elemental speciation has recently gained a lot of attention. Much of this is due to ever improving separation capabilities of Chromatographic techniques, the high sensitivity of ICP-MS, and the continuing development of better interface techniques. Additionally, there is a growing awareness of the need to monitor various species of an analyte, rather than just total analyte concentrations, due to their often varying natures. For the sake of learning from different elemental speciation approaches, this review brings together some selected types of elemental speciation which have been recently seen in literature. These include separations using various forms of liquid chromatography, such as reversed phase, reversed phase ion pairing, micelle, ion exchange, and size exclusion. Elemental speciation employing gas Chromatographie separations and supercritical fluid separations are discussed as well as elemental speciation using capillary electrophoresis.  相似文献   

17.
A new method for the simultaneous separation and determination of four arsenic species [As(III), As(V), monomethylarsonic acid and dimethylarsinic acid], three selenium species [Se(IV), Se(VI) and selenomethionine] as well as Sb(III) and Sb(V) is presented. The speciation was achieved by on-line coupling of anion exchange high-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). Chromatographic parameters such as the composition and pH of the mobile phase were optimised. Limits of detection are below 4.5 μg L–1 (as element) for Sb(III) and the selenium species and below 0.5 μg L–1 for the other species. Precisions of retention times were better than 2% RSD and of peak areas better than 8% RSD for all the species investigated. Received: 13 January 1999 / Accepted: 4 March 1999  相似文献   

18.
Speciation of mercury in salmon egg cell cytoplasm was investigated by surfactant-mediated high-performance liquid chromatography/inductively coupled plasma mass spectrometry (HPLC/ICP-MS), where an ODS (octadecylsilica) column coated with a bile acid derivative, CHAPS (3-[(3-cholamidopropyl)-dimethylammonio]-1-propane sulfonate), was used for species separation. Prior to the speciation analysis, total Hg in the cell cytoplasm was determined by ICP-MS at m/z 202 in a flow injection mode. For the precise measurement, salmon egg cell cytoplasm was diluted five-fold with 0.1 M Tris (Tris(hydroxymethyl)aminomethane)-HNO3 buffer solution, and the standard addition method was employed. Thus, the total concentration of Hg in cell cytoplasm was estimated to be 12.4 ng g−1 on the wet weight basis. Next, the cell cytoplasm diluted five-fold with 0.1 M Tris-HNO3 buffer solution was analyzed by surfactant-mediated HPLC with the dual detection system of a UV absorption detector and an ICP-MS instrument. Two peaks corresponding to some proteins and small molecules were mainly observed in those chromatograms. When salmon egg cell cytoplasm was diluted five-fold with 0.01 M Tris buffer solution or pure water, some precipitates appeared probably because of precipitation of hydrophobic proteins in cytoplasm. After the precipitates were eliminated with a membrane filter, the filtrate was subjected to the analysis by surfactant-mediated HPLC/UV/ICP-MS. As a result, the peaks for small molecular species of Hg were clearly observed at the retention time near 4.0 min (corresponding to low-molecular weight zone) in the chromatograms with UV absorption detection as well as with Hg- and S-specific ICP-MS detections. The small molecule bound with Hg was identified as cysteine through the cysteine-spiked experiment. In addition, the protein fraction on the chromatogram obtained by using the CHAPS-coated ODS column was further analyzed by SEC (size exclusion chromatography). Consequently, several protein peaks with molecular weight of 300, 50 and 12 kDa were observed in all the detections of UV absorption, Hg and Se, although two peaks among them were coincident in the case of S. These results indicate that Hg in salmon egg cell cytoplasm binds with proteins containing selenocysteine and/or cysteine residues in proteins.  相似文献   

19.
A detailed comparison of the performance of inductively coupled plasma mass spectrometry (ICP-MS), with quadrupole and double-focusing instruments for the speciation of selenium in urine has been carried out. Selenium sensitivity about 23-59 times higher with double-focusing ICP-MS detection was observed, but limits of detection were only 1-8.7 times better because of background noise. Selenium species separation has been carried out by both reversed-phase and vesicle-mediated high-performance liquid chromatography (HPLC), coupled on-line with the detector via conventional nebulization and via on-line focused microwave digestion-hydride generation. A remarkable improvement in sensitivity (28-110 times better for (77)Se depending on the chromatographic system) and elimination of interference problems from the urinary matrix or the components of the mobile phases were achieved when an on-line microwave digestion-hydride generation interface was used, but the background noise was much higher than with conventional nebulization. Therefore, the limits of detection were not as low as expected from such improvement in the sensitivity. More selenocompounds can be separated, and a slight improvement in the sensitivity and limits of detection was obtained when the vesicle-mediated HPLC system was used as compared with reverse-phase chromatography. However, the use of several complementary chromatographic systems, such as reverse-phase HPLC, is recommended to bring some light on the selenocompounds present in basal human urine. Comparative data of rat urine speciation are also given.  相似文献   

20.
Selenium is an essential element for human health. It has been recognized as an antioxidant and chemopreventive agent in cancer. Selenium is known to develop its biological activity via selenocysteine residue in the catalytically active centre of selenoproteins. The main source of selenium in human beings is the diet. However, in several regions of the world the content of selenium in diet has been estimated insufficient for a correct expression of the proteins. The beneficial effects of selenium on human health are strongly dependent on its chemical form and concentration. This review critically evaluated the state-of-the art of selenium speciation in biological matrices mainly focused in nutritional and food products. Besides the number of publications related to selenium speciation, isolation and accurate characterization and quantification of selenium species is still a challenge. Hyphenated techniques based on coupling chromatography separation with inductively coupled plasma spectrometry (ICP-MS) and its combination with molecular mass spectrometry (ESI-MS, ESI-MS-MS and MALDI-TOF) and isotopic dilution allow identification, quantification and structural characterization of selenium species. Particular attention is paid in the development of Se-enriched food and nutritional products and how the application of the techniques mentioned above is mandatory to get reliable results on selenium metabolisms in these particular matrices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号