首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
The influence of temperature in a supported liquid membrane (SLM) extraction of triazole fungicides was investigated. The mass transfer parameters such as diffusion coefficient, flux and apparent viscosity were determined at temperatures ranging from 5 to 40°C. Increase in temperature led to an increase in diffusion coefficient and flux with a flowing acceptor solution. The apparent viscosity also decreased with an increase in temperature. However, the increase in mass transfer parameters did not result in an overall increase in extraction efficiency with a stagnant or circulation acceptor phase. Stripping of the analytes from the membrane into the acceptor phase as well as the configuration of the extraction unit could have limited the influence of temperature on mass transfer. The partition coefficient of analytes from the acceptor solution to the membrane, KA, was found to be much higher than that from the donor solution to the membrane KD, thus triazole compounds preferred to remain in the membrane even with an increased extraction temperature.  相似文献   

2.
Basic studies on carrier-mediated transport as a mechanism to extract polar drugs by hollow fibre-based liquid-phase microextraction are presented for the first time. Hydrophilic alkaline drugs with log P (octanol/water partition coefficient) values less than 1 were selected as model substances. Sodium octanoate served as carrier and was added to the sample solution at pH 7 to form hydrophobic ion-pair complexes with the analytes. The ion-pair complexes were extracted into octanol as liquid membrane immobilised in the pores of the hollow fibre. Further extraction into an aqueous acceptor phase inside the lumen of the hollow fibre was facilitated by counter transport of protons from the acceptor solution to the sample solution. Protons from the acceptor solution released the analytes at the liquid membrane-acceptor interface and neutralized the carrier. The acceptor phase was analysed by capillary electrophoresis. The studies show that high extraction recoveries of ionic hydrophilic drugs can be obtained at a sample-acceptor volume ratio of 10. Linear calibration graphs and clean electropherograms indicate that carrier-mediated transport is a promising technique in microextraction of polar drugs from biological matrices.  相似文献   

3.
A new hollow fibre liquid phase microextraction technology with an ionic liquid as the carrier was developed to determine the fluoroquinolone antibiotics in milk. In this technology, a porous polypropylene hollow fibre was filled with aqueous ionic liquid and the extraction efficiency of different factors, such as the type of hollow fibre membrane carrier, the pH and ionic strength of the donor solution, the pH of the acceptor solution, the stirring rate and the extraction time, were investigated. The optimised extraction condition was: [OMim][BF4] impregnated in the pores of the hollow fibre; 0.1?mol?L?1 of Na2HPO4 (pH 11.0) as the acceptor solution was injected into the lumen of the hollow fibre; 0.1?mol?L?1 H3PO4 (pH 5.0) was used as the donor solution; 600?rpm was selected as the stirring rate; 120?min was the optimum extraction time. The proposed method provided very high factors with 130-fold, 156-fold and 116-fold enrichment of ofloxacin, ciprofloxacin and enrofloxacin, respectively.  相似文献   

4.
This paper describes a simultaneously performed two-/three-phase hollow-fiber-based liquid-phase microextraction (HF-LPME) method for the determination of aromatic amines with a wide range of pKa (−4.25 to 4.6) and log KOW (0.9–2.8) values in environmental water samples. Analytes including aniline, 4-nitroaniline, 2,4-dinitroaniline and dicloran were extracted from basic aqueous samples (donor phase, DP) into the microliter volume of organic membrane phase impregnated into the pores of the polypropylene hollow fiber wall, then back extracted into the acidified aqueous solution (acceptor phase, AP) filling in the lumen of the hollow fiber. The mass transfer of the analytes from the donor phase through the organic membrane phase into acceptor phase was driven by both the counter-coupled transport of hydrogen ions and the pH gradient. Afterwards, the hollow fiber was eluted with 50 μL methanol to capture the analytes from both the organic membrane and the acceptor phase. Factors relevant to the enrichment factors (EFs) were investigated. Under the optimized condition (DP: 100 mL of 0.1 M NaOH with 2 M Na2SO4; organic phase: di-n-hexyl with 8% trioctylphosphine oxide (TOPO); AP: 10 μL of 8 M HCl; extraction time of 80 min), the obtained EFs were 405–2000, dynamic linear ranges were 5–200 μg/L (R > 0.9976), and limits of detection were 0.5–1.5 μg/L. The presence of humic acid (0–25 mg/L dissolved organic carbon) had no significant effect on the extraction efficiency. The proposed procedure worked very well for real environmental water samples with microgram per liter level of analytes, and good spike recoveries (80–103%) were obtained.  相似文献   

5.
The present work has for the first time described and verified a theoretical model of the analytical extraction process electro-membrane extraction (EME), where target analytes are extracted from an aqueous sample, through a thin layer of 2-nitrophenyl octylether immobilized as a supported liquid membrane (SLM) in the pores in the wall of a porous hollow fibre, and into an acceptor solution present inside the lumen of the hollow fibre by the application of an electrical potential difference. The mathematical model was based on the Nernst-Planck equation, and described the flux over the SLM. The model demonstrated that the magnitude of the electrical potential difference, the ion balance of the system, and the absolute temperature influenced the flux of analyte across the SLM. These conclusions were verified by experimental data with five basic drugs. The flux was strongly dependent of the potential difference over the SLM, and increased potential difference resulted in an increase in the flux. The ion balance, defined as the sum of ions in the donor solution divided by the sum of ions in the acceptor solution, was shown to influence the flux, and high ionic concentration in the acceptor solution relative to the sample solution was advantageous for high flux. Different temperatures also led to changes in the flux in the EME system.  相似文献   

6.
A three‐phase hollow fiber liquid‐phase microextraction method coupled with CE was developed and used for the determination of partition coefficients and analysis of selected nitrophenols in water samples. The selected nitrophenols were extracted from 14 mL of aqueous solution (donor solution) with the pH adjusted to pH 3 into an organic phase (1‐octanol) immobilized in the pores of the hollow fiber and finally backextracted into 40.0 μL of the acceptor phase (NaOH) at pH 12.0 located inside the lumen of the hollow fiber. The extractions were carried out under the following optimum conditions: donor solution, 0.05 M H3PO4, pH 3.0; organic solvent, 1‐octanol; acceptor solution, 40 μL of 0.1 M NaOH, pH 12.0; agitation rate, 1050 rpm; extraction time, 15 min. Under optimized conditions, the calibration curves for the analytes were linear in the range of 0.05–0.30 mg/L with r2>0.9900 and LODs were in the range of 0.01–0.04 mg/L with RSDs of 1.25–2.32%. Excellent enrichment factors of up to 398‐folds were obtained. It was found that the partition coefficient (Ka/d) values were high for 2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2,4‐dinitrophenol and 2,6‐dinitrophenol and that the individual partition coefficients (Korg/d and Ka/org) promoted efficient simultaneous extraction from the donor through the organic phase and further into the acceptor phase. The developed method was successfully applied for the analysis of water samples.  相似文献   

7.
Transport behaviour of Lu(III) across a polypropylene hollow fibre‐supported liquid membrane containing di(2‐ethylhexyl)phosphoric acid (DEHPA) in dihexyl ether as a carrier has been studied. The donor phase was LuCl3 in the buffer solution consisting of 0.2 M sodium acetate at pH 2.5–5.0. A miniaturised system with a single hollow fibre has been operated in a batch mode. The concentration of Lu(III) was determined by indirect voltammetric method using Zn–EDTA complex. The effect of pH and volume of the donor phase, DEHPA concentration in the organic (liquid membrane) phase, the time of extraction and the content of the acceptor phase on the Lu(III) extraction and stripping behaviour was investigated. The results were discussed in terms of the pertraction and removal efficiency, the memory effect and the mean flux of Lu(III). The optimal conditions for the removal of 177Lu(III) from labelled 177Lu‐radiopharmaceuticals were discussed and identified. The removal efficiency of Lu(III) greater than 99% was achieved at pH of the donor phase between 3.5 and 5.0 using DEHPA concentration in the organic phase of 0.47 M and the ratio of the donor to the acceptor phase of 182.  相似文献   

8.
《Analytical letters》2012,45(15):2343-2356
The influence of temperature on the extraction and selectivity of naproxen, ibuprofen, and triclosan by a thin-walled hollow fiber silicone rubber membrane was investigated. Determination of the diffusion coefficients and flux values at 25, 40, and 60 degrees Celsius was undertaken. The diffusion coefficient and flux were found to increase with temperature. It was also observed that at higher temperatures, mass transfer was influenced by the amount extracted in the acceptor phase. However, diffusion from the bulk donor phase through the hollow fiber silicone rubber membrane was shown to control the transport of analytes at lower temperatures. When applied to wastewater, the hollow fiber silicone rubber showed remarkable selectivity toward the analytes. However, at high temperatures, the amount of matrix components extracted also increased slightly. The amount extracted nearly doubled when extraction was performed at 40 degrees Celsius compared to 25 degrees Celsius, indicating that temperature increased the efficiency of the hollow fiber silicone rubber membrane. The application of the technique to municipal wastewater showed remarkable selectivity and reproducibility. The concentrations of these compounds were from 18.4 (1.37 percent) micrograms per liter for triclosan to 1.1 (0.16 percent) micrograms per liter for naproxen in the influent and 2.7 (0.29 percent) micrograms per liter for triclosan to 0.4 (0.01 percent) micrograms per liter for naproxen in the effluent.  相似文献   

9.
An automated hollow fibre membrane extraction technique was developed for the GC-MS determination of pharmaceutical and endocrine disrupting compounds in water samples. Enrichment was carried out inside a porous polypropylene hollow fibre membrane, which separated the aqueous and organic phases and regulated the transfer of analytes. n-Octanol placed inside the hollow fibre was used as the acceptor solution. A water-solvent ratio of about 300:1 was used to concentrate the analytes. After 1 hour's extraction of the water sample under magnetic stirring, 1 microl of the n-octanol phase was automatically injected from the hollow fibre into the GC-MS. Development work included examining the influence of different sample matrices, volumes, extraction times and extraction solvents. The detection limits, linearity and standard deviations of the method were determined using drugs such as ibuprofen, phenazone and carbamazepine as well as the endocrine disrupting compounds. technical nonylphenols, bisphenol A, 17alpha-ethinylestradiol and tonalide by way of example.  相似文献   

10.
A new method based on negligible depletion hollow fiber-protected liquid-phase microextraction coupled with high-performance liquid chromatography (HPLC) was developed for the simultaneous determination of partitioning coefficients (KOW) and acid dissociation constants (pKa), by using phenol, 4-chlorophenol and 2,4-dichlorophenol as model compounds. A 37-mm length polypropylene hollow fiber membranes (600 μm inner diameter, 200 μm wall-thickness, 0.2 μm pore size, ∼70% porosity) with two-end sealed were filled with 1-octanol by ultrasonic agitation to prepare the extraction device. The extraction device was deployed in sample solutions, prepared by spiking target analytes in 1-octanol saturated aqueous solutions (500 mL), for negligible depletion extraction. After equilibrium was reached (∼5 h), the 1-octanol in the lumen of the hollow fiber membrane was collected for HPLC determination of the target analytes. As the depletion of the analytes in aqueous samples was negligible, the distribution coefficient (DOW) could be calculated based on the measured equilibrium concentration in 1-octanol (CO) and the initial concentration (CW) in the aqueous sample of the target analyte (DOW = CO/CW). The DOW values measured at various pH values were nonlinearly regressed with pH to obtain the KOW and pKa values of a compound. Results showed that the measured values of the KOW and pKa of these model compounds agreed well with literature data.  相似文献   

11.
In this study we on-line coupled hollow fiber liquid–liquid–liquid microextraction (HF-LLLME), assisted by an ultrasonic probe, with high-performance liquid chromatography (HPLC). In this approach, the target analytes – 2-chlorophenol (2-CP), 3-chlorophenol (3-CP), 2,6-dichlorophenol (2,6-DCP), and 3,4-dichlorophenol (3,4-DCP) – were extracted into a hollow fiber (HF) supported liquid membrane (SLM) and then back-extracted into the acceptor solution in the lumen of the HF. Next, the acceptor solution was withdrawn on-line into the HPLC sample loop connected to the HF and then injected directly into the HPLC system for analysis. We found that the chlorophenols (CPs) could diffuse quickly through two sequential extraction interfaces – the donor phase – SLM and the SLM – acceptor phase – under the assistance of an ultrasonic probe. Ultrasonication provided effective mixing of the extracted boundary layers with the bulk of the sample and it increased the driving forces for mass transfer, thereby enhancing the extraction kinetics and leading to rapid enrichment of the target analytes. We studied the effects of various parameters on the extraction efficiency, viz. the nature of the SLM and acceptor phase, the compositions of the donor and acceptor phases, the fiber length, the stirring rate, the ion strength, the sample temperature, the sonication conditions, and the perfusion flow rate. This on-line extraction method exhibited linearity (r2 ≥ 0.998), sensitivity (limits of detection: 0.03–0.05 μg L−1), and precision (RSD% ≤ 4.8), allowing the sensitive, simple, and rapid determination of CPs in aqueous solutions and water samples with a sampling time of just 2 min.  相似文献   

12.
A method for sample preparation of methoxy-s-triazine herbicides using supported liquid membrane extraction has been developed. The analytes were selectively extracted from the donor solution of pH 7.0 into a porous polytetrafluoroethylene (PTFE) membrane impregnated with di-n-hexyl ether. After diffusion through the hydrophobic membrane the analytes were irreversibly trapped in the acidic acceptor phase of pH 1.0. The donor waste was monitored for estimating the amount of sample trapped at certain time intervals. Comparison of the selectivity with solid-phase extraction has been performed. A low detection limit, ca. 15 ng/l, has been obtained with liquid membrane extraction.  相似文献   

13.
Mulugeta M  Megersa N 《Talanta》2004,64(1):101-108
Supported liquid membrane (SLM) method for preconcentration and enrichment of the two bipyridilium herbicides, namely diquat and paraquat, from environmental water samples has been developed. The permanently charged cationic herbicides were extracted from a flowing aqueous solution to a stagnant acidic acceptor solution across a liquid membrane containing 40% (v/v) di-(2-ethylhexyl) phosphoric acid dissolved in di-n-hexyl ether. The mass transfer of analytes is driven by the counter-coupled transport of hydrogen ions from the acceptor to the donor phase. The efficiency of the extraction process depends on the donor solution pH, the amount of the mobile carrier added to the liquid membrane and the concentration of the counter ion in the acceptor solution. The applicability of the method for extraction of these quaternary ammonium herbicides from environmental waters was also investigated by spiking analyte sample solutions in river water. With 24 h sample enrichment concentrations of diquat and paraquat down to ca. 10 ng/L could be detected in environmental waters.  相似文献   

14.
In this paper, extraction kinetics was investigated experimentally and theoretically in hollow fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) with the basic drugs droperidol, haloperidol, nortriptyline, clomipramine, and clemastine as model analytes. In HF-LPME, the analytes were extracted by passive diffusion from an alkaline sample, through a (organic) supported liquid membrane (SLM) and into an acidic acceptor solution. In EME, the analytes were extracted by electrokinetic migration from an acidic sample, through the SLM, and into an acidic acceptor solution by application of an electrical potential across the SLM. In both HF-LPME and EME, the sample (donor solution) was found to be rapidly depleted for analyte. In HF-LPME, the mass transfer across the SLM was slow, and this was found to be the rate limiting step of HF-LPME. This finding is in contrast to earlier discussions in the literature suggesting that mass transfer across the boundary layer at the donor–SLM interface is the rate limiting step of HF-LPME. In EME, mass transfer across the SLM was much more rapid due to electrokinetic migration. Nevertheless, mass transfer across the SLM was rate limiting even in EME. Theoretical models were developed to describe the kinetics in HF-LPME, in agreement with the experimental findings. In HF-LPME, the extraction efficiency was found to be maintained even if pH in the donor solution was lowered from 10 to 7–8, which was below the pKa-value for several of the analytes. Similarly, in EME, the extraction efficiency was found to be maintained even if pH in the donor solution increased from 4 to 11, which was above the pKa-value for several of the analytes. The two latter experiments suggested that both techniques may be used to effectively extract analytes from samples in a broader pH range as compared to the pH range recommended in the literature.  相似文献   

15.
Surfactant‐assisted electromembrane extraction coupled with cyclodextrin‐modified capillary electrophoresis was developed for the separation and determination of Tranylcypromine enantiomers in biological samples. This combination would provide a new strategy for selective and sensitive determination of target analytes. The addition of surfactant in the donor solution improved the analyte transport into the lumen of hollow fiber that resulted in an enhancement in the analytes migration into acceptor solution. Optimization of the variables, affecting proposed method, was carried out and best results were achieved with a 175 V potential as driving force of the electromembrane extraction, 2‐nitrophenyloctylether as the supported liquid membrane, donor solution containing 0.2 mM Triton X‐100 with pH 3 and 0.1 M HCl for acceptor solution. Then, the extract was analyzed using cyclodextrin‐modified capillary electrophoresis method for separation of Tranylcypromine enantiomers. The best results were obtained with a phosphate running buffer (100 mM, pH 2.0) containing 7% w/v hydroxypropyl‐α‐cyclodextrin. Under the optimum conditions, a low limit of detection (3.03 ng/mL), good linearity (R2 > 0.9953), and relative standard deviations below 4.0% (n = 5) were obtained. Finally, this procedure was applied to determine the concentration of Tranylcypromine enantiomers in urine samples with satisfactory results.  相似文献   

16.
A simple and solvent-minimized sample preparation technique based on two-phase hollow fiber-protected liquid-phase microextraction has been developed and used for the determination of partition coefficient and analysis of selected pesticides in environmental water samples. The analysis was performed by gas chromatography–electron capture detector. Three pesticides namely hexaconazole, quinalphos, and methidathion were considered as target analytes. Extraction conditions such as solvent identity, salt concentration, stirring speed, extraction time, length of the hollow fiber, and volume of donor phase were optimized. The analytes were extracted from a donor phase (water sample) through 3 μL of an organic solvent immobilized in the pores of a porous polypropylene hollow fiber and then into the acceptor phase present inside the hollow fiber. Excellent extractions of the analytes were achieved under the optimized conditions, with relative standard deviations of 4.6–7.9%, correlation coefficients (r 2) of 0.9954–0.9986 and limits of detection of 3–7 ng L?1. The proposed method provided good average enrichment factors of up to 250-fold. The partition coefficients of the analytes determined were found to be directly correlated with the enrichment factor. The present methodology also confirms the robustness of microextraction for monitoring trace levels of pesticides in environmental water samples.  相似文献   

17.
A simple liquid-liquid-liquid microextraction with automated movement of the acceptor and the donor phase (LLLME/AMADP) technique is described for the quantitative determination of five phenoxyacetic acids in water using a disposable and ready to use hollow fiber. The target compounds were extracted from the acidified sample solution (donor phase) into the organic solvent residing in the pores of the hollow fiber and then back extracted into the alkaline solution (acceptor phase) inside the lumen of the hollow fiber. The fiber was held by a conventional 10-microl syringe. The acceptor phase was sandwiched between the plunger and a small volume of the organic solvent (microcap). The acceptor solution was repeatedly moved in and out of the hollow fiber assisted by a programmable syringe pump. This repeated movement provides a fresh acceptor phase to come in-contact with the organic phase and thus enhancing extraction kinetics leading to high enrichment of the analytes. The microcap separates the aqueous acceptor phase and the donor phase in addition of being partially responsible for mass transfer of the analytes from donor solution (moving in and out of the hollow fiber from the open end of the fiber) to the acceptor solution. Separation and quantitative analyses were then performed using liquid chromatography (LC) with ultraviolet (UV) detection at 280 nm. Various parameters affecting the extraction efficiency viz. type of organic solvent used for immobilization in the pores of the hollow fiber, extraction time, stirring speed, effect of sodium chloride, and concentration of donor and acceptor phases were studied. Repeatability (RSD, 3.2-7.4%), correlation coefficient (0.996-0.999), detection limit (0.2-2.8 ng ml(-1)) and enrichment factors (129-240) were also investigated. Relative recovery (87-101%) and absolute recoveries (4.6-13%) have also been calculated. The developed method was applied for the analysis of river water.  相似文献   

18.
A new organic solvent-free microextraction technique termed liquid-gas-liquid microextraction (LGLME) was developed. In this technique, a small amount (6 microl) of aqueous acceptor solution (0.5M NaOH) is introduced into the channel of a 2.65 cm polypropylene hollow fiber. The hollow fiber is then immersed in an aqueous sample donor solution. The aqueous acceptor phase in the channel of the hollow fiber is separated from the sample solution by the hydrophobic microporous hollow fiber wall with air inside its pores. The analytes (phenols) passed through the microporous hollow fiber membrane by gas diffusion and were then trapped by the basic acceptor solution. After extraction, the acceptor solution was withdrawn into a microsyringe and injected into a capillary electrophoresis sample vial for subsequent analysis. Limits of detection of between 0.5 and 10 microg/l for eight phenols could be achieved. The relative standard deviations (n=6) of this technique between 2.7 and 7.6%. The technique also provides good enrichment factors for all the eight analytes.  相似文献   

19.
Liquid-liquid-liquid microextraction with automated movement of the acceptor and the donor phase technique is described for the extraction of six hydroxyaromatic compounds in river water using a disposable and ready to use hollow fiber. Separation and quantitative analyses were performed using LC with UV detection at 254 nm. Analytes were extracted from the acidified sample solution (donor phase) into the organic solvent impregnated in the pores of the hollow fiber and then back extracted into the alkaline solution (acceptor phase) inside the lumen of the hollow fiber. The fiber was held by a conventional 10 microL LC syringe. The acceptor phase was sandwitched between the plunger and a small volume of the organic solvent (microcap). The acceptor solution was repeatedly moved in and out of the hollow fiber using a syringe pump. This movement provides a fresh acceptor phase to come in contact with the organic phase and thus enhancing extraction kinetics thereby leading to the improvement in enrichment of the analytes. The microcap separates the acceptor phase and the donor phase in addition to being partially responsible for mass transfer of the analytes from the donor solution to the acceptor solution. Under stirring, a fresh donor phase will enter through the open end of the fiber that will also contribute to the mass transfer. Various parameters affecting the extraction efficiency viz type of organic solvent, extraction time, stirring speed, effect of sodium chloride, and concentration of donor and acceptor phases were studied. RSD (3.9-5.6%), correlation coefficient (0.995-0.997), detection limit (2.0-51.2 ng/mL), enrichment factor (339-630), relative recovery (93.2-97.9%), and absolute recovery (33.9-63.0%) have also been investigated. The developed method was applied for the analysis of river water.  相似文献   

20.
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4 mL, pH 4.5 KH2PO4 with 2 M Na2SO4; acceptor phase: 25 μL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1–0.4 μg/L, RSD ≤ 5%) and good linear range (1–2000 ng/mL, R2 ≥ 0.999) were obtained for all the analytes. The presence of humic acid (0–25 mg/L dissolved organic carbon) and bovine serum albumin (0–100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2–103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号