1.
研究了利用玻碳电极吸附伏安法测定痕量硫化物的新方法。在含高铁离子的酸性溶液中,硫化物与对-氨基苯二甲基盐酸盐(p-ADAD)反应生成亚甲基蓝,采用线性扫描伏安法亚甲基蓝于-0.30 V(vs.SCE)在玻碳电极上出现灵敏的还原峰,峰电流与S2-浓度在0~25μg/mL范围内呈良好的线性关系。优化了实验条件,研究了电极反应机理。该方法具有灵敏、简便、快速、避免汞污染等特点。已成功用于多种水样中痕量硫化物的测定,回收率为98.0%~104.6%,结果令人满意。  相似文献   

2.
The present investigation of phenol and chlorophenols is conducted on the surface of glassy carbon by cyclic and square wave stripping voltammetry, and by Fourier‐transform infrared spectroscopy. The surface fouling is accompanied by the appearance of reversible peaks at lower potential range (+0.1 to+0.4 V), that grew up with CV‐cycling and attributed to the electro‐redox reactions of formed polymer film via electropolymerization. The electroanalytical monitoring of formed polymer oxidation peaks improved both sensitivity and detection limit by 35 and 10 times, respectively. The FT‐IR supported semiempirical prediction attributes the electropolymerization to the formation of orthopara and/or orthometa C? C coupled‐system.  相似文献   

3.
《Electroanalysis》2006,18(6):579-585
A new sensitive electrochemical procedure is presented for the determination of Rutin based on the accumulation of Rutin onto the surface of hanging mercury drop electrode for 80 s. Then the preconcentrated Rutin‐complex was analyzed by cathodic stripping square‐wave voltammetry. The effect of various parameters such as pH, concentration of copper, accumulation potential, accumulation time and scan rate on the sensitivity were studied. The optimum conditions for determination of Rutin include pH 6.0, 6.0 ng mL?1 copper(II) concentration, accumulation potential of ?0.30 V and scan rate of 0.40 V s?1. Under the optimum conditions and for an accumulation time of 80 s, the measured peak current at about ?0.03 V is proportional to the concentration of Rutin over the range of 2.0–85.0 nM. The practical limit of detection is 0.5 nM. The relative standard deviations for six replicate analyses of 10 and 50 nM Rutin are 1.8% and 1.7%, respectively. The method was applied to the determination of Rutin in synthetic, tea, and pharmaceutical samples with satisfactory results. The diffusion coefficient, complex formation constant and number of electron transfer of Rutin–Cu(II) complex was also estimated.  相似文献   

4.
Pencil graphite electrode (PGE) modified with MWCNT and Bi3+ (MWCNT/Bi/PGE) was utilized in simultaneous analysis of Pb2+, Cd2+, and Zn2+. Surface and electrochemical characteristics of MWCNT/Bi/PGE were investigated via SEM, cyclic voltammetry, electrochemical impedance spectroscopy, and FTIR measurements. Even though modification with MWCNT did not improve the electroactive surface area, it significantly decreased the charge transfer resistance. Furthermore, modification with Bi3+ significantly increased the sensitivity. Finally, MWCNT/Bi/PGE exhibited the highest sensitivity and reproducibility compared to PGE and PGE modified with only MWCNT. MWCNT/Bi/PGE provided LOD values of 0.27, 0.43, and 1.63 μg L−1, and linear ranges of 1–80, 5–80, and 10–80 μg L−1 for Pb2+, Cd2+, and Zn2+, respectively. Proposed modification method offers effective electroanalytical performance with low time consumption and cost for the analyst.  相似文献   

5.
The voltammetric behavior of Strontium Ranelate (SR) was studied using Cyclic (CV), differential pulse (DPV) and square wave (SWV) voltammetry. CV showed two well‐defined, irreversible, diffusion‐controlled anodic peaks using Britton‐Robinson buffer, pH 2.0 at Pencil graphite (PGE), Carbon paste (CPE) and glassy carbon (GCE) electrodes. The peak current‐concentration relationship was rectilinear over the range 1.0–10.0, 1.0–11.25 and 2.5–24.0 µg/mL at PGE, CPE and GCE respectively, with a minimum detectability of 0.17, 0.24 and 0.39 µg/mL for peak 1 and 0.19, 0.27 and 0.51 µg/mL for peak 2. Recoveries showed the high accuracy of the method; 99.8 %, 99.5 % and 99.7 % at PGE, CPE and GCE respectively for peak 1 and 100.1 %, 99.9 % and 99.7 % at PGE, CPE and GCE respectively for peak 2. Hence DPV and SWV were conducted for the quantitative determination of SR in its pure and pharmaceutical dosage form. the method was validated and the results were in good agreement with those obtained from the reported method.  相似文献   

6.
In this paper, an electrochemical application of bismuth‐film electrode (BiFE) fabricated via ex‐situ electrodeposition onto a glassy carbon electrode for testosterone determination was investigated in aqueous and aqueous/surfactant solutions. In cyclic voltammetry, the compound showed one irreversible and adsorption‐controlled reduction peak. The BiFE revealed good linear response in the examined concentration range of 1 to 45 nmol L?1 testosterone in Britton? Robinson buffer, pH 5.0 containing 3 mmol L?1 cetyltrimethylammonium bromide. The limit of detection was 0.3 nmol L?1 (0.09 ng mL?1). Finally, the BiFE was satisfactorily applied for quantitation of testosterone in both pharmaceutical (oil‐based ampoule) and biological (human urine) samples.  相似文献   

7.
以玻碳电极为工作电极,研究了邻苯二胺(OPD)为底物伏安法检测辣根过氧化物酶(HRP)及其标记物的方法。HRP能够催化H_2O_2氧化OPD,其反应产物在玻碳电极上于-0.42V(vs.Ag/Agcl)左右产生一个灵敏的还原峰,峰电流随着HRP浓度的增大而增大,借助此还原电流可以测定HRP,并进而可用于以HRP为标记物的电化学酶免疫分析。用方波伏安法对酶催化反应条件和酶催化反应产物的测定条件进行了详细的研究,在最佳条件下测定游离HRP的线性范围是1.0×10~(-10)~4.0×10~(-9)g/mL,检出限为8.5×10~(-11)g/mL;对游离的酶标记物(IgG-HRP)的测定最大稀释比为1:2000000。  相似文献   

8.
《Analytical letters》2012,45(13):2247-2258
Abstract

The electrochemical behavior of the quercetin (Q) at a carbon paste electrode (CPE) containing 15% paraffin oil is investigated. Square wave anodic stripping voltammetric (SWASV) was used to determine quercetin in the presence of 0.04 M phosphate buffer (pH ~4) containing 0.1 M KCl with 15 s accumulation time at 25±1°C. Under the optimal experimental conditions, the adsorbed form is oxidized irreversibly. The linear concentration ranged from 67.66 to 338.3 ppb quercetin. The detection limit of 6.77 ppb Q (r=0.9997), with 15 s accumulation time and the relative standard deviation of 0.45 (n=5) was calculated. The interferences of some metal ions and some amino acids were studied. The method was applied to the analysis of spiked urine, with recovery of 99.9±0.5, and the relative standard deviation of 3.2%. Results were compared with the reported methods.  相似文献   

9.
本文建立了在铋膜修饰电极上采用方波吸附溶出伏安法同时测定纺织品中痕量Co2+和Ni2+的方法.以NH3-NH4Cl作为缓冲液,在丁二酮肟浓度为10 μmol/L的体系中,Co2和Ni2+的还原峰电位分别为-1.13 V和-1.03 V.当缓冲溶液pH为9.2,富集电位为-0.7V,富集时间为200 s时,C02 +和Ni2+在0.5~50 μg/L范围呈现良好的线性关系,相关系数R2>0.99,其检出限分别为0.79 μg/L和0.96 μg/L,其它金属离子的干扰较小.采用标准加入法测定纺织品中Co>和Ni2+,回收率在94.88%~104.14%之间.  相似文献   

10.
嗪草酮在玻碳电极上的伏安行为及测定   总被引:1,自引:0,他引:1  
用循环伏安法及微分脉冲阴极溶出伏安法,在玻碳电极(GCE)上研究了嗪草酮在不同底液中的伏安特性,发现在B-R(Britton-Robinson)电解质溶液(pH2)中于-0.524V(vs.SCE)左右产生1个尖锐的阴极还原峰。嗪草酮的浓度在1.0×10-6~1.0×10-4mol/L范围内与峰电流呈良好的线性关系(r=0.9987)。对其反应机理作了初步探讨。  相似文献   

11.
Sulfamethoxazole (SMZ), an antibacterial sulfonamide drug, has been selectively determined using poly‐1,5‐diaminonaphthalene (p‐DAN) modified glassy carbon electrode (GCE). The modified sensor was characterized by field emission scanning electron microscopy (FE‐SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). SMZ showed linear response in the concentration range of 0.5–150 µM by using square wave voltammetry (SWV) and the detection limit was found to be 0.05 nM with sensitivity of 0.085 µA µM?1. The proposed sensor has been successfully employed to determine SMZ in the pharmaceutical tablets and human urine samples.  相似文献   

12.
《Electroanalysis》2004,16(3):231-237
The electrochemical oxidation of antipsychotic drug amisulpride (AMS) has been studied in pH range 1.8–11.0 at a stationary glassy carbon electrode by cyclic, differential pulse and square‐wave voltammetry. Two oxidation processes were produced in different supporting electrolyte media. Both of the oxidation processes were irreversible and exhibited diffusion controlled. For analytical purposes, very resolved voltammetric peaks were obtained using differential pulse and square‐wave modes. The linear response was obtained in the range of 4×10?6 to 6×10?4 M for the first and second oxidation steps in Britton‐Robinson buffer at pH 7.0 and pH 3.0 (20% methanol v/v), respectively, using both techniques. These methods were used for the determination of AMS in tablets. The first oxidation process was chosen as indicative of the analysis of AMS in biological media. The methods were successfully applied to spiked human serum, urine and simulated gastric fluid samples.  相似文献   

13.
A laponite modified carbon paste electrode was prepared, characterized and applied for the 2,4-dichlorophenol (2,4-DCP) voltammetric determination. It takes advantage of the ability of laponite to adsorb phenols, as well as of its availability and very low cost. Kinetic and equilibrium data for 2,4-DCP adsorption by laponite in aqueous dispersions demonstrated that the adsorption process obeyed a pseudo first order kinetic model and was consistent with the formation of adsorbed multilayers on a surface with heterogeneous pore distribution. The composite paste electrode exhibited a heterogeneous surface with 65 % increased surface area and 27 % enhanced catalytic activity compared to the unmodified one. The adsorptive stripping voltammetric determination of 2,4-DCP at an electrode with an optimized graphite:laponite ratio of 55 : 15 w% using a 3 min accumulation time at pH 5.5 was found to be suitable for its quantification in the linear concentration range extended up to 50 μmol L−1 with a sensitivity of 0.56 μA L μmol−1 and a LOD of 0.2 μmol L−1 (S/N=3).The 2,4-DCP electrochemical response was not affected by the presence of some structurally similar phenols, like catechol and p-nitrophenol, while resorcinol, 2-chlorophenol, and 4-chlorophenol presented interferences. The results were validated by 2,4-DCP determination in spiked tap water.  相似文献   

14.
Electrochemical properties of proguanil were investigated by a voltammetric method (SWV) using a renewable silver amalgam film electrode. The influence of buffer pH as well as potential amplitude, frequency, and step potential was studied. The repeatability, precision and recovery of the developed method were examined. The reduction peak current was used for proguanil voltammetric determination in the range 1×10?7–6×10?6 mol L?1, LOD=2.9×10?8 mol L?1, LOQ=9.7×10?8 mol L?1. The standard addition method was used to determine proguanil in a commercial formulation (Malarone) and in spiked urine.  相似文献   

15.
A simple and reliable method based on adsorptive stripping at an electrochemically pretreated glassy carbon electrode (GCE) was proposed for simultaneous or individual determination of guanine and adenine in DNA. The detection sensitivity of guanine and adenine was improved greatly by activating the GCE electrochemically. After accumulation on pretreated GCE at open circuit for 5 min or at the potential of +0.3 V for 120 s, guanine and adenine produced well-defined oxidation peaks at about +0.8 and +1.1 V, respectively in pH 5 phosphate buffer. The detection limit for individual measurement of guanine and adenine was 4.5 ng ml−1 (3×10−8 mol l−1) and 4 ng ml−1 (3×10−8 mol l−1), respectively. Acid-denatured DNA showed two oxidation peaks corresponding to guanine and adenine residues in the same buffer. The proposed method can be used to estimate the guanine and adenine contents in DNA with good selectivity in a linear range of 0.25-5 μg ml−1.  相似文献   

16.
《Electroanalysis》2006,18(11):1081-1089
This paper describes the voltammetric behavior of As(III) at the hanging mercury drop electrode (HMDE) in the presence of sodium diethyl dithiocarbamate (SDDC) and a new voltammetric method for the determination of As(III) at trace levels. The method is based on the adsorptive deposition of a As(III) complex with SDDC at ?0.45 V (vs. Ag/AgCl) on the HMDE in acidic medium of 0.01 mol L?1 HCl (pH 2.0) and its cathodic stripping during the potential scan (100 mV s?1). The linear range for the determination of As(III) in the presence of SDDC (4 μmol L?1) in water samples was between 1 and 10 μg L?1 for a deposition time of 300 s (r=0.994) and between 10 and 100 μg L?1 for a deposition time of 60 s (r=0.999). For the determination of As(III) in dialysis concentrate samples, the linear range was between 5 and 25 μg L?1 for a deposition time of 180 s (r=0.992) and between 10 and 100 μg L?1 for a deposition time of 60 s (r=0.996). Detection limits of 0.3 and 2.2 μg L?1 in water and dialysis concentrate samples were calculated for the method using a deposition time of 300 and 180 s, respectively. Recovery values between 93.0 and 110.0% for As(III) added to deionized, mineral, seawater (synthetic and real) and dialysis concentrate samples prove the satisfactory accuracy and applicability of the procedure.  相似文献   

17.
A new carbon‐based mercury thin‐film electrode consisting of screen‐printed carbon on a low temperature co‐fired ceramic substrate was made. Ex‐situ mercury deposition in a potassium thiocyanate solution was used. This approach an electrode with high long‐term stability (>500 measurement cycles) and reproducibility (≤2 %) for sensitive determination of ultra trace heavy metals, using differential pulse anodic stripping voltammetry. The detection limits were 0.25, 0.08 and 5.5 ng mL?1 for Cd(II), Pb(II), and Zn(II), respectively. The method was applied to the determination of the analytes in water, wastewater, lake water, and certified reference material samples with satisfactory results.  相似文献   

18.
By incorporation of synthesized magnetite nanoparticles (Fe3O4 NPs) coated with a new Schiff base into carbon paste electrode, a novel modified electrode was constructed for simultaneous determination of ultra trace amounts of Cd(II), Cu(II) and Hg(II). The complexation reaction of Schiff base with metal ions was studied spectrophotometrically. Under optimal conditions a detection limit of 0.20, 0.90 and 1.00 ng mL?1 for Cd(II), Cu(II) and Hg(II), respectively, was obtained. We take the advantages of the proposed method for simple, rapid, sensitive and selective simultaneous determination of trace amounts of hazardous Cd(II), Cu(II) and Hg(II) in water and foodstuff samples.  相似文献   

19.
《Electroanalysis》2003,15(3):230-234
A detailed study of the electrochemistry of ambroxol at a glassy carbon electrode was carried out in the pH range 1.8–11.0 in aqueous solution using cyclic and differential pulse voltammetry. The compound was oxidized irreversibly at high positive potentials resulting in the formation of a chemical product at less positive potentials, which was more readily oxidized than the parent compound. In addition, a differential pulse voltammetric method was proposed for the determination of the drug in different pharmaceutical formulations, and in drug dissolution studies.  相似文献   

20.
《Electroanalysis》2004,16(21):1745-1754
This works reports the use of adsorptive stripping voltammetry (AdSV) for the trace determination of chromium on a rotating‐disk bismuth‐film electrode (BFE). During the reductive accumulation step, all the chromium species in the sample were reduced to Cr(III) which was complexed with cupferron and the complex was accumulated by adsorption on the surface of a preplated BFE. The stripping step was carried out by using a square‐wave (SW) potential‐time voltammetric signal. Electrochemical cleaning of the bismuth film was employed, enabling the same bismuth film to be used for a series of measurements in the presence of dissolved oxygen. The experimental variables as well as potential interferences were investigated and the figures of merit of the method were established. Using the selected conditions, the 3σ limit of detection for chromium was 100 ng L?1 (for 120 s of preconcentration) and the relative standard deviation was 3.6% at the 2 μg L?1 level (n=8). Finally, the method was applied to the determination of chromium in real samples with satisfactory results.  相似文献   