首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work describes the construction, characterization, and application of a three‐electrode‐integrated sensor into a micropipette tip. The three electrodes (working, pseudoreference and counter) are positioned at the end of a micropipette tip. The working electrode (graphite composite or gold microfiber) is placed inside the micropipette tip and the pseudo‐reference and counter electrodes outside (diametrically opposed sides). This approach is candidate for portable applications and allows the analysis and studies in low‐volume solutions (ca. 10 µL) which are useful for waste minimization and development of clean analytical methods. In addition, the three‐electrode‐integrated sensor can be easy used as detector in flow injection system through its direct joining at the end of polyethylene tubing of the FIA system.  相似文献   

2.
设计了一种由2个石墨电极短路相连组成工作电极的新的电化学池装置.操作时首先通过外力按压使极少量固体微粒粘附在其中一个石墨电极表面上,然后在溶液存在下将微粒夹紧并固定在2个石墨电极表面之间进行电化学测定.电化学转化过程中生成的可溶性物质被封闭在2个石墨电极表面之间而得到测定.用该技术对钯沉积在氧化铝上而组成的催化剂的电化学行为以及黄铁矿的电化学行为进行了研究.结果表明,其兼具可电解粘合剂碳糊电极和固体微粒伏安法(voltammetry of microparticles)技术的优点而避免了各自的缺点:即不使用粘合剂,从而消除了粘合剂中杂质产生的氧化或还原电流的影响;可测定电化学转化过程中生成的可溶性物质;分辨率好、易于操作.  相似文献   

3.
A polypyrrole electrode modified with a tetrasulfonated nickel(II) phthalocyanine complex (GCE/PPy/NiPcTs) was used as amperometric electrochemical detector in a flow injection system, in order to determine some antioxidants in foods. The lather were separated by HPLC and detected at the modified electrode. Previous investigations carried out in our laboratory employed this electrode and cyclic voltammetry (CV), obtaining excellent results, due to an electrocatalytic effect on the oxidation of certain alimentary antioxidants, such tert-butylhydroquinone (TBHQ), 3-tert-butyl-4-hydroxyanisole (BHA) and propylgallate (PG). In order to obtain good separation, the chromatographic conditions were optimised. The geometry of the flow injection analysis (FIA) circuit and the reproducibility of the results were also optimised and, finally, the linear relationship between the signal and the concentration was verified. The proposed procedure is more precise and accurate than the conventional voltammetry methods. These results offer new analytical possibilities to this type of modified electrodes. The developed methods were applied to the determination of these antioxidants in commercial food.  相似文献   

4.
A simple and automated methodology for a sensitive electrochemical detection of enzyme immunoassays that employ alkaline phosphatase (AP) as label has been developed. A flow injection system with programmable pump, valve and cell functions, amperometric detection of indigo and screen-printed electrodes (SPEs) are responsible for the advantages of this methodology. Amperometric detection at a low potential of indigo, the product of the enzymatic hydrolysis of the substrate 3-indoxyl phosphate (IP), is combined with a flow injection system. This incorporates in the flow cell a disposable screen-printed board provided with a graphite working electrode. No electrode pretreatment is necessary to obtain reproducible signals. The system was applied to the determination by an enzyme-linked immunosorbent assays (ELISA) of pneumolysin (PLY), a toxin related to respiratory infections. Linear calibration curves for low and high concentration ranges were obtained. These were also performed in a proteic matrix and linearity was also obtained.  相似文献   

5.
Stripping voltammetry in environmental and food analysis   总被引:4,自引:0,他引:4  
The review covers over 230 papers published mostly in the last 5 years. The goal of the review is to attract the attention of researchers and users to stripping voltammetry in particular, its application in environmental monitoring and analysis of foodstuffs. The sensors employed are impregnated graphite, carbon paste, thick film carbon/graphite and thin film metallic electrodes modified in-situ or beforehand. Hanging mercury drop electrodes and mercury coated glassy carbon electrodes are also mentioned. Strip and long-lived sensors for portable instruments and flow through systems are discussed as devices for future development and application of stripping voltammetry.  相似文献   

6.
This work reports the construction and characterization of plastic electrochemical micro‐flow‐cells with integrated injection‐moulded polymer electrodes. The three electrodes (working, auxiliary, and reference) were fabricated by injection‐moulding from a conducting grade of polystyrene loaded with carbon fibers. On‐chip reference electrodes were prepared by coating one of the conducting polymer electrodes with a Ag/AgCl layer (implemented either by e‐beam evaporation of Ag followed by electrochemical formation of AgCl or by applying a Ag/AgCl paste). Working electrodes were either polymer electrodes coated with Au by e‐beam evaporation or bare conducting polymer electrodes. The electrodes were integrated into the micro‐flow‐cells by an over‐moulding process followed by ultrasonic welding. The devices were characterized by optical and electrochemical techniques. Studies by cyclic voltammetry (CV), anodic stripping voltammetry (ASV) and electrochemiluminescence (ECL) demonstrate ‘proof–of‐principle’ of the micro‐flow‐cells as electrochemical sensors.  相似文献   

7.
Stripping voltammetry in environmental and food analysis   总被引:1,自引:0,他引:1  
The review covers over 230 papers published mostly in the last 5 years. The goal of the review is to attract the attention of researchers and users to stripping voltammetry in particular, its application in environmental monitoring and analysis of foodstuffs. The sensors employed are impregnated graphite, carbon paste, thick film carbon/graphite and thin film metallic electrodes modified in-situ or beforehand. Hanging mercury drop electrodes and mercury coated glassy carbon electrodes are also mentioned. Strip and long-lived sensors for portable instruments and flow through systems are discussed as devices for future development and application of stripping voltammetry. Received: 30 March 2000 / Revised: 30 May 2000 / Accepted: 6 June 2000  相似文献   

8.
A new conducting composite flexible material prepared from cellulose acetate (CA) polymer and graphite has been developed and used for the fabrication of electrodes, which were then characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Scanning electron microscopy (SEM) was used to provide information concerning the morphology of the composite electrode surface. The potential window, background currents and capacitance were evaluated by cyclic voltammetry in the pH range from 4.6 to 8.2. The voltammetry of model electroactive species demonstrates a close to reversible electrochemical behaviour, under linear diffusion control. The electroactive area of the composite electrodes increases after appropriate electrode polishing and electrochemical pre-treatment. The electrodes were used as substrate for the electropolymerisation of the phenazine dye neutral red, for future use as redox mediator in electrochemical biosensors. The composite electrodes were also successfully used for the amperometric detection of ascorbate at 0.0 V vs. SCE, and applied to the measurement of ascorbate in Vitamin C tablets; the sensor exhibits high sensitivity and a low detection limit of 7.7 μM. Perspectives for use as a versatile, mechanically flexible and robust composite electrode of easily adaptable dimensions are indicated.  相似文献   

9.
Carbon nanofibres (CNFs) and graphite flake microparticles were added to thermoplastic polystyrene polymer with the aim of making new conductive blends suitable for 3D‐printing. Various polymer/carbon blends were evaluated for suitability as printable, electroactive material. An electrically conducting polystyrene composite was developed and used with commercially available polystyrene (HIPS) to manufacture electrodes suitable for electrochemical experiments. Electrodes were produced and evaluated for cyclic voltammetry of aqueous 1,1’‐ferrocenedimethanol and differential pulse voltammetry detection of aqueous Pb2+ via anodic stripping. A polystyrene/CNF/graphite (80/10/10 wt%) composite provides good conductivity and a stable electrochemical interface with well‐defined active geometric surface area. The printed electrodes form a stable interface to the polystyrene shell, give good signal to background voltammetric responses, and are reusable after polishing.  相似文献   

10.
This work presents a comparative study between two different methods for the preparation of mediator-modified screen-printed electrodes, to be used as detectors in a reliable flow injection system for the determination of the nicotinamide adenine dinucleotide (NADH) coenzyme. The best strategy was selected for the final development of compact biosensors based on dehydrogenase enzymes. For the first immobilisation strategy, different redox mediators were electropolymerised onto the SPE surface. The second immobilisation strategy was carried out using polysulfone–graphite composites, which were deposited by screen-printing technology onto the screen-printed electrode (SPE) surface. Both methods achieved an effective and reliable incorporation of redox mediators to the SPE configuration. Finally, a flow system for ammonium determination was developed using a glutamate dehydrogenase (GlDH)-Meldola's Blue (MB)-polysulfone-composite film-based biosensor.

The stability of the redox mediators inside the composite films as well as the negligible fouling effect observed on the electrode surface improve the repeatability and reproducibility of the sensors, important features for continuous analysis in flow systems. Furthermore, the optimised bio/sensors, incorporated in a flow injection system, showed good sensitivities and short response times. Such a good analytical performance together with the simple and fast sensor construction are interesting characteristics to consider the polysulfone-composite films as attractive electrochemical transducer materials for the development of new dehydrogenase-based SPEs.  相似文献   


11.
A method using flow injection (FI) with amperometric detection at anodized boron-doped diamond (BDD) thin films has been developed and applied for the determination of tetracycline antibiotics (tetracycline, chlortetracycline, oxytetracycline and doxycycline). The electrochemical oxidation of the tetracycline antibiotics was studied at various carbon electrodes including glassy carbon (GC), as-deposited BDD and anodized BDD electrodes using cyclic voltammetry. The anodized BDD electrode exhibited well-defined irreversible cyclic voltammograms for the oxidation of tetracycline antibiotics with the highest current signals compared to the as-deposited BDD and glassy carbon electrodes. Low detection limit of 10 nM (signal-to-noise RATIO = 3) was achieved for each drug when using flow injection analysis with amperometric detection at anodized BDD electrodes. Linear calibrations were obtained from 0.1 to 50 mM for tetracycline and 0.5–50 mM for chlortetracycline, oxytetracycline and doxycycline. The proposed method has been successfully applied to determine the tetracycline antibiotics in some drug formulations. The results obtained in percent found (99.50–103.01%) were comparable to dose labeled.  相似文献   

12.
Brainina KZ 《Talanta》1971,18(5):513-539
Film stripping voltammetry is a new electrochemical analytical method consisting in concentrating the test substance in the form of a metal or a sparingly soluble compound on the electrode surface and subsequently recording the current for electrodissolution of the deposit. The method has been worked out for determination of metal ions, anions and variable valence ions, with sensitivities as low as 10(-9)M. As indicator electrodes, solid, usually graphite, electrodes and stationary mercury electrodes are used.  相似文献   

13.
In this work, carbon electrodes modified with aminophenols were developed for the production of pesticides biosensors based on acetylcholinesterase. The polymers were potentiodynamically deposited on a graphite electrode surface by the oxidation of monomers, 2-aminophenol, 3-aminophenol and 4-aminophenol. The electrochemical behaviour and surface analysis of the electrodes modified by polyaminophenols non-immobilized and immobilized on acetylcholinesterase were studied by cyclic voltammetry, electrochemical impedance spectroscopy and atomic force microscopy. Roughness values obtained for graphite electrodes modified with poly(4-aminophenol) and poly(4-aminophenol)/acetylcholinesterase were 174 and 86 nm, respectively. The acetylcholinesterase enzyme was immobilized on a graphite and a graphite modified with poly(4-aminophenol), and these electrodes were coupled in the flow system. Potentiometric response due to hydrogen ions generated by an enzymatic system in the presence of acetylcholine chloride substrate was evaluated. The results showed that the graphite/poly(4-aminhophenol) sensor presents high sensitivity to hydrogen ions when compared with other graphite/polyaminophenols sensors. The biosensor coupled in a continuous flow system was employed for the detection of dichlorvos. The detection and quantification limits were 0.8 and 2.4 μmol L−1 dichlorvos, respectively. This sensor reveals an efficient and promising material for biomolecules immobilization.  相似文献   

14.
A novel flow-injection amperometric method was proposed for the sensitive and enzymeless determination of hydrogen peroxide based on its electrocatalytic reduction at a palladium nanoparticle-modified pretreated pencil graphite electrode in a laboratory-constructed electrochemical flow cell. Cyclic voltammograms of the unmodified and modified electrodes were recorded in pH 7.0 phosphate buffer containing 0.10 M KCl at a scan rate of 50?mV s?1 for the investigation of electrocatalytic reduction of hydrogen peroxide at the palladium nanoparticle-modified pretreated pencil graphite electrode. Cyclic voltammograms of the pretreated pencil graphite electrode revealed an irreversible oxidation peak and a weak reduction peak of hydrogen peroxide at +1100?mV and –450?mV vs. an Ag/AgCl/KCl saturated reference electrode. However, the reduction of hydrogen peroxide was observed at –100?mV with an increase in current in the cyclic voltammograms of the palladium nanoparticle-modified pretreated pencil graphite electrode compared to the unmodified electrode. These results indicate that the palladium nanoparticle-modified pretreated pencil graphite electrode exhibits efficient electrocatalytic activity for the reduction of hydrogen peroxide. A linear concentration range was obtained between .01 and 10.0?mM hydrogen peroxide with a detection limit of 3.0 µM from flow injection amperometric current–time curves recorded in pH 7.0 phosphate buffer at –100?mV and a 2.0?mL min?1 flow rate. The novelty of this work relies on its use of a laboratory-constructed flow cell constructed for the pencil graphite electrode using these inexpensive, disposable, and electrochemically reactive modified electrodes for the amperometric determination of hydrogen peroxide in a flow injection analysis system.  相似文献   

15.
Erdoğdu G  Karagözler AE 《Talanta》1997,44(11):2011-2018
Electrodes modified by the electrodepozition of conducting organic polymers such as poly(3-methylthiophene)(PMT), polypyrrole (PPY) and polyaniline (PAN) were used as chemical sensors for voltammetric analysis and flow injection detection of some organic and biological molecules. The electrochemical behaviors of catechol, ascorbic acid, hydroquinone, dopamine, epinephrine, acetaminophen and p-aminophenol were examined by differential pulse voltammetry. The electrochemical behavior of these molecules at different electrodes was compared and the effects on behavior of electrolyte type and its pH and the film thickness were systematically examined. The results showed that the proposed modified surface catalyzes the oxidation of these compounds. Electrocatalytic 'efficiency' decreases in order of poly-3-methylthiophene, polypyrrole and polyaniline. Voltammetric peak positions were affected by the nature of the electrolyte and its pH. Also, the effect of increasing film thickness was to observe increased peak heights. Polymer coated electrodes were also used in an amperometric detector for flow injection analysis of most of the these compounds. The responses of the polymer electrode were 5-15 times larger as compared with those of bare platinum. PMT showed improved performance as an amperometric detector for flow injection analysis systems over other types of polymer electrodes. Detection limits as low as 10(-8)-10(-9) M were achieved using the PMT, compared with 10(-6)-10(-8) M using platinum electrodes. In the flow injection analysis, with increasing molecular weight of analyte molecules was to observe decreased peak heights.  相似文献   

16.
《Analytical letters》2012,45(7):1231-1246
ABSTRACT

Strategies to modify screen-printed electrodes (SPE) for lead determination are reported. Dithizone was mixed with graphite ink to obtain a modified screen-printed strip to detect ppb levels of lead(II) (detection limit 12 μg/l) using square wave anodic stripping voltammetry (SWASV). In addition, screen-printed electrodes were also modified by casting a few μl of a Nafion® solution onto the working electrode surface. In this case, ppb levels of lead were detected (detection limit 15 μg/1), using potentiometric stripping analysis (PSA). The addition of an ionophore to Nafion® polymer was also investigated, but this did not yield a significant improvement.  相似文献   

17.
《Analytical letters》2012,45(7):1055-1068
Abstract

Tyrosinase-modified carbon paste electrodes were prepared using lyophilised powder of the enzyme purchased from different companies. The selectivity of these electrodes for nine phenolic compounds, including six substituted catechols, has been studied. The signals obtained for catechol were always higher than those found for other phenolic compounds. Cyclic voltammetry and flow injection measurements indicated that the response of the tyrosinase-modified carbon paste electrodes was limited by the rate of the enzymatic oxidation of catechols. Different approaches of paste electrode preparation have been studied and compared. Direct mixing of enzyme into the graphite powder doped with the osmium based mediator, resulted in the highest sensitivity for the studied substrates. However, substrate selectivity was found to be dependent on the source of enzyme used for electrode preparation.  相似文献   

18.
Spectrographic graphite electrodes were modified through adsorption with laccase from Trametes versicolor. The laccase-modified graphite electrode was used as the working electrode in an amperometric flow-through cell for monitoring phenolic compounds in a single line flow injection system. The experimental conditions for bioelectrochemical determination of catechol were studied and optimized. The relative standard deviation of the biosensor for catechol (10 μM, n=12) was 1.0% and the reproducibility for six laccase-modified graphite electrodes, prepared and used different days was about 11%. The optimal conditions for the biosensor operation were: 0.1 M citrate buffer solution ( at pH 5.0), flow rate of 0.51 ml min−1 and a working potential of −50 mV versus Ag|AgCl. At these conditions the responses of the biosensor for various phenolic compounds were recorded and the sensor characteristics were calculated and compared with those known for biosensors based on laccase from Coriolus hirsutus, cellobiose dehydrogenase (CDH) from Phanerochaete chrysosporium and horseradish peroxidase (HRP).  相似文献   

19.
A microvolume electrochemical cell was designed that allows voltammetric measurements to be conducted in less than 10-μl volumes of solutions. The cell body consists of a stainless-steel needle functioning as both the reference and auxiliary electrodes. A cylindrical graphite fiber microelectrode, inserted into the needle, serves as the working electrode. Microliter samples of solution can be aspirated into the cell by means of an Eppendorf micropipet attached to the needle. The performance of the microvolume cell was investigated by conducting square-wave anodic stripping voltammetry of lead and cadmium and square-wave voltammetry of epinephrine, both in solutions containing dissolved oxygen. The cell functioned very well in both methods; however, a needle preplated with mercury was found to improve the performance of the cell in anodic stripping voltammetry.  相似文献   

20.
A general approach using principal component analysis was applied to amperometric data obtained from flow injection analysis (FIA) to select conducting electroactive polymers (CEPs) and applied potential waveforms for discrimination of potassium and methylamine. The results were compared with the selection from the application of the PCA approach for cyclic voltammetry data in our previous research. Good agreement between the two methods of selection was found, which indicates that within the general qualitative limits of the approach, PCA can be applied for selection of chemical and electrochemical parameters for FIA detection/discrimination using CEP sensor arrays detector for a range of analytes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号