首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
《Analytical letters》2012,45(6):1083-1095
Abstract

A sensitive electrochemical DNA biosensor based on nano-ZnO/chitosan composite matrix for DNA hybridization detection was developed. The Nano-ZnO was synthesized by the hydrothermal method and dispersed in chitosan, which was used to fabricate the modification of the glassy carbon electrode (GCE) surface. The ZnO/chitosan-modified electrode exhibited good biocompatibility and excellent electrochemical conductivity. The hybridization detection was monitored with differential pulse voltammetry (DPV) measurement using methylene blue (MB) as an indicator. The established biosensor can effectively discriminate complementary target sequence and two-base-mismatched sequence, with a detection limit of 1.09 × 10?11 mol L?1 of complementary target.  相似文献   

3.
本研究以电化学聚合法制备了聚苯胺掺杂乙醇胺修饰电极,并成功固定了DNA探针。文中对修饰电极的制备和DNA的固定杂交条件进行了探讨,并利用循环伏安法测定嵌入双链DNA(dsDNA)分子碱基对中的亚甲基蓝的氧化还原峰电流,识别和测定溶液中互补的单链DNA(ssDNA)片段,从而实现对溶液中不同基因片段的检测。  相似文献   

4.
A DNA probe that was based on methylene blue (MB) imprinted polyvinyl pyridine polymer (MIP) modified carbon paste electrodes were developed for the first time for electrochemical monitoring of DNA. Probes were built up by adsorbing MB onto modified electrodes prior to DNA immobilization. It was shown that DNA strongly immobilizes on MIP modified electrodes when MB was adsorbed in advance of DNA immobilization. The performance of the MB imprinted polymer modified carbon paste electrodes (MIP‐CPE) to rebind the template molecule (MB) were compared to those of control polymer modified (non‐imprinted polymer NIP‐CPE) and bare (CPE) electrodes. Electrochemical signal resulting from the oxidation of guanine moiety of the immobilized probe DNA was high enough on the constructed platform, implicating that probes of this kind could be favorably used for DNA analysis. These probes exhibited high selectivity for its complementary DNA sequences (target). HBV‐DNA hybridization was studied to evaluate the selectivity of the probes for complementary, non‐complementary and mismatch sequences. The detection limit of the probe for the target DNA was 8.72 µg/mL (1.38 µM), which was better than those attained by some earlier DNA sensor studies.  相似文献   

5.
A new electrochemical sequence‐specific DNA detection platform based on primer generation‐rolling circle amplification (PG‐RCA), methylene blue (MB) redox indicator, and indium tin oxide (ITO) electrode is reported. In the presence of a specific target sequence, PG‐RCA, an isothermal DNA amplification technique, produced large amounts of amplicons in an exponential manner. In addition to the standard components, the reaction mixture contained MB, which bound with the PG‐RCA amplicons. End‐point electrochemical measurement by differential pulse voltammetry (DPV) was performed using ITO electrode. The amplicon‐bound MB resulted in a lower DPV signal than free MB due to a smaller diffusion coefficient as well as electrostatic repulsion between the negatively charged amplicon‐bound MB and ITO electrode. With simple assay design (recognition probe) and instrumentation (operating temperature at 37 °C and ITO electrode without the need for probe immobilization), this detection platform is well suited for point‐of‐care and on‐site testing. Real‐time measurement was also achieved by pretreating the ITO electrode with bovine serum albumin.  相似文献   

6.
《Electroanalysis》2004,16(7):577-582
We report a method for the detection of DNA hybridization in connection to lead sulfide (PbS) nanoparticle tags and electrochemical stripping measurement of the lead. A kind of lead sulfide nanoparticle with free carboxyl groups on its surface was synthesized in aqueous solution. The nanoparticle was used as a marker to label a sequence‐known oligonucleotide, which was then employed as a DNA probe for identifying a target ssDNA immobilized on a PPy modified electrode based on a specific hybridization reaction. The hybridization events were monitored by the oxidation dissolution of the lead sulfide anchored on the hybrids and the indirect determination of the lead ions by anodic stripping voltammetry (ASV). The detection limit is 0.3 pmol L?1 of target oligonucleotides. The PbS nanoparticle combining its easy conjugation to the DNA molecule with the highly sensitive stripping voltammetry detection of lead shows its promising application in the electrochemical DNA hybridization analysis assay.  相似文献   

7.
巯基乙酸自组装膜DNA电化学传感器对转基因NOS的定量检测   总被引:5,自引:1,他引:5  
以转基因植物中常用的根癌农杆菌终止子(NOS)为检测对象, 将巯基乙酸自组装于金电极表面形成巯基乙酸自组装单分子膜, 再利用乙基-(3-二甲基氨丙基)碳二亚胺盐酸盐(EDC)和N-羟基琥珀酰亚胺(NHS)的活化作用将NOS探针ssDNA序列固定于金电极表面形成NOS电化学生物传感器, 以亚甲基蓝(MB)为杂交指示剂, 对NOS靶基因相关序列进行了定量检测.  相似文献   

8.
This article summarizes the sensor performance of four electrochemical DNA sensors that exploit the recently developed displacement-replacement sensing motif. In the absence of the target, the capture probe is partially hybridized to the signaling probe at the distal end, positioning the redox label, methylene blue (MB), away from the electrode. In the presence of the target, the MB-modified signaling probe is released; one type of probe is capable of assuming a stem-loop probe (SLP) conformation, whereas the other type adopts a linear probe (LP) conformation. Independent of the sensor architecture, all four sensors showed “signal-on” sensor behavior. Unlike the previous report, here we focused on elucidating the effect of the redox label tether length and flexibility on sensor sensitivity, specificity, selectivity, and reusability. For both SLP and LP sensors, the limit of detection was 10 pM for sensors fabricated using a signaling probe with three extra thymine (T3) bases linked to the MB label. A limit of detection of 100 pM was determined for sensors fabricated using a signaling probe with five extra thymine (T5) bases. The linear dynamic range was between 10 pM and 100 nM for the T3 sensors, and between 100 pM and 100 nM for the T5 sensors. When compared to the LP sensors, the SLP sensors showed higher signal enhancement in the presence of the full-complement target. More importantly, the SLP-T5 sensor was found to be highly specific; it is capable of discriminating between the full complement and single-base mismatch targets even when employed in undiluted blood serum. Overall, these results highlight the advantages of using oligo-T(s) as a tunable linker to control flexibility of the tethered redox label, so as to achieve the desired sensor response.  相似文献   

9.
We present a new strategy for the label‐free electrochemical detection of DNA hybridization based on gold nanoparticles (AuNPs)/poly(neutral red) (PNR) modified electrode. Probe oligonucledotides with thiol groups at the 5‐end were covalently linked onto the surface of AuNPs/PNR modified electrode via S‐Au binding. The hybridization event was monitored by using differential pulse voltammetry (DPV) upon hybridization generates electrochemical changes at the PNR‐solution interface. A significant decrease in the peak current was observed upon hybridization of probe with complementary target ssDNA, whereas no obvious change was observed with noncomplementary target ssDNA. And the DNA sensor also showed a high selectivity for detecting one‐mismatched and three‐mismatched target ssDNA and a high sensitivity for detecting complementary target ssDNA, the detection limit is 4.2×10?12 M for complementary target ssDNA. In addition, the DNA biosensor showed an excellent reproducibility and stability under the DNA‐hybridization conditions.  相似文献   

10.
In this work, we report on the preparation of a simple, sensitive DNA impedance sensor. Firstly gold nanoparticles were electrodeposited on the surface of a gold electrode, and then probe DNA was immobilized on the surface of gold nanoparticles through a 5′‐thiol‐linker. Electrochemical impedance spectroscopy (EIS) was used to investigate probe DNA immobilization and hybridization. Compared to the bare gold electrode, the gold nanoparticles modified electrode could improve the density of probe DNA attachment and the sensitivity of DNA sensor greatly. The difference of electron transfer resistance (ΔRet) was linear with the logarithm of complementary oligonucleotides sequence concentrations in the range of 2.0×10?12 to 9.0×10?8 M, and the detection limit was 6.7×10?13 M. In addition, the DNA sensor showed a fairly good reproducibility and stability during repeated regeneration and hybridization cycles.  相似文献   

11.
以乙二胺为手臂分子制备的DNA修饰电极及其伏安性能   总被引:5,自引:0,他引:5  
Carboxyl was formed on the surface of glassy carbon electrode(GCE) by electrochemical oxidation. Ethylenediamine(En) was used as the arm molecule to link carboxyl with dsDNA using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC) and N- hydroxysuccinimide (NHS) as the activators to prepare dsDNA modified electrode(dsDNA/En/GCE). It was shown that dsDNA couM be covalently immobilized on the surface of GCE. ssDNA modified electrode(ssDNA/En/GCE) was obtained via the thermal denaturation of dsDNA/En/GCE. The dsDNA/En/GCE and ssDNA/En/GCE were characterized by voltammetry with methylene blue(MB) as the indicator. The results indicated that the currents of the redox peaks of MB at ssDNA/En/GCE were larger than those at dsDNA/En/GCE, and the currents of the redox peaks at En/GCE were the smallest. The peak-currents of MB at the DNA modified electrode had good reproducibility after multi-denaturation and hybridization cycles.  相似文献   

12.
A novel sensitive and simple electrochemical DNA sensor is reported for the determination of p53 tumor suppressor gene. A gold nanoparticle/graphene nanocomposite-modified glassy carbon electrode was prepared and methylene blue was used as the hybridization redox indicator. Scanning electron microscopic and electrochemical characterization demonstrated that the gold nanoparticles and graphene were present on the electrode. The resulting sensor provided suitable electrochemical response to the p53 tumor suppressor gene with a linear dynamic range from 0.1 to 1000?nM. The limit of detection was 0.012?nM. The sensor was able to differentiate a complete complementary DNA sequence, single-base mismatched DNA sequence, and a three-base mismatched DNA sequence. The precision of the device was satisfactory, with a relative standard deviation of 4.1% for 11 measurements. The combination of gold nanoparticles and a graphene nanocomposite provided enhanced capabilities for the determination of DNA for clinical applications.  相似文献   

13.
基于纳米金胶标记DNA探针的电化学DNA传感器研究   总被引:6,自引:0,他引:6  
以纳米金胶为标记物,将其标记于人工合成的5-端巯基修饰的寡聚核苷酸片段上,制成了具有电化学活性的金胶标记DNA电化学探针;在一定条件下,使其与固定在玻碳电极表面的靶序列进行杂交反应,利用ssDNA与其互补链杂交的高度序列选择性和极强的分子识别能力,以及纳米金胶的电化学活性,实现对特定序列DNA片段的电化学检测以及对DNA碱基突变的识别.  相似文献   

14.
应用旋转圆盘电极和电化学阻抗法研究了二茂铁在Tris-NaC l(pH=7.2)缓冲溶液中于旋转玻碳电极上的电化学阻抗行为及其与DNA的相互作用.结果表明,二茂铁于旋转电极的伏安曲线呈现明显的极限电流平阶,而其交流阻抗谱则出现两个电容弧.二茂铁与DNA的作用,若受扩散过程控制则其极限扩散电流随DNA浓度增大而减小,而在电化学控制过程中则表现为电化学反应电阻随DNA浓度增大而增大.根据旋转圆盘电极和电化学阻抗谱测试,表明由这两种方法数据拟合求得的二茂铁条件电位速率常数能够很好地相互吻合,但如存在DNA时,则其条件电位速率常数有一定程度的减小.  相似文献   

15.
Palladium nanoparticles, in combination with multi‐walled carbon nanotubes (MWCNTs), were used to fabricate a sensitivity‐enhanced electrochemical DNA biosensor. MWCNTs and palladium nanoparticles were dispersed in Nafion, which were used to modify a glassy carbon electrode (GCE). Oligonucleotides with amino groups at the 5′ end were covalently linked onto carboxylic groups of MWCNTs on the electrode. The hybridization events were monitored by differential pulse voltammetry (DPV) measurement using methylene blue (MB) as an indicator. Due to the ability of carbon nanotubes to promote electron‐transfer and the high catalytic activities of palladium nanoparticles for electrochemical reaction of MB, the sensitivity of presented electrochemical DNA biosensors was remarkably improved. The detection limit of the method for target DNA was 1.2×10?13 M.  相似文献   

16.
Oxidative damage of DNA was assessed with glassy carbon electrode (GCE) coated with electropolymerized Methylene Blue (MB). For this purpose, DNA solution was first mixed with an oxidant (Fenton reagent, H2O2 alone and in the presence of Cu(II) ions) and then placed on the polymeric film surface. After washing, the cyclic voltammogram was recorded in buffer solution and the anodic peak potential measured against that before the contact with DNA. Oxidative DNA damage resulted in remarkable decrease of the anodic peak potential which depended on the oxidant nature and incubation period. Specificity of the DNA – MB interactions was confirmed by surface plasmon resonance (SPR) measurements. Similar experiment performed with polymerized Methylene Green (MG) and Neutral Red (NR) showed lower selectivity of the response toward various sources of reactive oxygen species. The protocol of the DNA damage detection was tested on the estimation of antioxidant properties of green tea extract and red table wine.  相似文献   

17.
An electrochemical DNA biosensor for human papillomavirus (HPV) 16 detection has been developed. For this proposed biosensor, l-cysteine was first electrodeposited on the gold electrode surface to form l-cysteine film (CYSFILM). Subsequently, HPV16-specific probe was immobilized on the electrode surface with CYSFILM. Electrochemistry measurement was studied by differential pulse voltammetry method (DPV). The measurement was based on the reduction signals of methylene blue (MB) before and after hybridization either between probe and synthetic target or extracted DNA from clinical samples. The effect of probe concentration was analyzed and the best results were seen at 1000 nM. The hybridization detection presented high sensitivity and broad linear response to the synthetic-target concentration comprised between 18.75 nM and 250 nM as well as to a detection limit of 18.13 nM. The performance of this biosensor was also investigated by checking probe-modified electrode hybridization with extracted DNA from samples. The results showed that the biosensor was successfully developed and exhibited high sensitivity and satisfactory selectivity to HPV16. These results allow for the possibility of developing a new portable detection system for HPVs and for providing help in making an effective diagnosis in the early stages of infection.  相似文献   

18.
We report the application of 4‐nitrophenyl diazonium modified electrodes towards the electrochemical detection of NADH. Selective activation of individual electrodes on a 5 element array by electro‐addressable conversion of nitro groups to amines and subsequent EDC/NHS crosslinking to the NADH oxidant, pyrroloquinoline quinone (PQQ), is demonstrated. Inactivated electrodes retained nitro functionality and were protected against non‐specific adsorption and mild chemical reactions. Electrodeposition conditions were used to control nitrophenyl film thickness and showed that while increased film thickness leads to greater functionalization density of PQQ, it also results in decreased electron transfer kinetics. The electrodeposition protocol can therefore serve as a method to control electrode functionalization density and film electron transfer kinetics. We believe this simple technique for selective electrode functionalization may facilitate the development of next generation multianalyte electrochemical sensors.  相似文献   

19.
《Electroanalysis》2006,18(21):2107-2114
Gold electrodes were modified with submonolayers of mercaptoacetic acid (RSH) and further reacted with poly(amidoamine) (PAMAM) dendrimers (generation 4.0) to obtain thin films, on which DNA probe was later immobilized to afford a stable recognition layers. The characterization of the PAMAM/RSH‐modified electrode was investigated by cyclic voltammetry (CV) and electrochemical impedance measurement. Differential pulse voltammogram (DPV) measurement was used to monitor DNA hybridization with daunomycin (DNR) as indicator. Experiments carried out with these novel materials not only showed an improved DNA attachment quantity on the dendrimers‐modified electrodes compared to DNA sensors with oligonucleotides directly immobilized on Au electrodes, but also exhibited a high selectivity, sensitivity and stability for the measurement of DNA hybridization.  相似文献   

20.
A novel assay for the voltammetric detection of 18-bases DNA sequences relating to Chronic Myelogenous Leukemia (CML, Type b3a2) using methylene blue (MB) as the hybridization indicator was reported. DNA was covalently attached onto a glassy carbon electrode (GCE) through amines of the DNA bases using N-hydroxysulfosuccinimide (NHS) and N-(3-dimethylamion)propyl-N′-ethyl carbodiimidehydrochloride (EDC). The covalently immobilized single-stranded DNA (ssDNA) could selectively hybridize with its complementary DNA (cDNA) in solution to form double-stranded DNA (dsDNA) on the surface. A significant increase of the peak current for methylene blue upon the hybridization of immobilized ssDNA with cDNA in the solution was observed. This peak current change was used to monitor the recognition of CML DNA sequence. This electrochemical approach is sequence specific as indicated by the control experiments in which no peak current change was observed if a non-complementary DNA sequence was used. Factors, such as DNA target concentration and hybridization conditions determining the sensitivity of the electrochemical assay were investigated. Under optimal conditions, this sensor has a good calibration range between 1.25 × 10−7 and 6.75 × 10−7 M, with CML DNA sequence detection limit of 5.9 × 10−8 M.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号