首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Summary Velocity-difference induced focusing (V-DIF) of analytes by a dynamic pH junction represents a simple yet effective on-line preconcentration method to improve concentration sensitivity in capillary electrophoresis (CE). Differences in buffer type, pH and conductivity between sample and background electrolyte (BGE) segments of the capillary are properties used to optimize purine focusing within a multi-section electrolyte system. This method permits the injection of large volumes of sample (up to 450 nL or about 18% of capillary length), resulting in over a 50-fold improvement in sensitivity with baseline resolution. The limit of detection (S/N=3) for xanthine is determined to less than 4.0×10−8 M under optimum conditions when using UV detection. Analysis of micromolar amounts of xanthine in pooled urine is also demonstrated without sample pretreatment. A dual mechanism involving dynamic pH and isotachophoretic modes is proposed to enhance analyte focusing performance when employing buffer pH junctions based on different types of electrolyte co-ions.  相似文献   

2.
Complementary on-line preconcentration strategies are needed when analyzing different classes of solutes in real samples by capillary electrophoresis (CE) with UV detection. The performance of three different on-line preconcentration (focusing) techniques under alkaline conditions was examined in terms of their selectivity and sensitivity enhancement for a group of steroids, including classes of androgens, corticosteroids and estrogens. Electrokinetic focusing of large sample injection plugs (up to 28% of effective capillary length or 22.1 cm) directly on-capillary can be tuned for specific classes of steroids based on changes in their mobility (velocity) using a multi-section electrolyte system in CE. A dynamic pH junction was applied for the selective resolution and focusing of weakly acidic estrogens using borate, pH 11.0 and pH 8.0 in the background electrolyte and the sample, respectively. Sweeping, using an anionic bile acid surfactant and neutral gamma-cyclodextrin (gamma-CD) under alkaline conditions (pH 8), resulted in focusing and separation of the moderately hydrophobic (non-ionic) classes of steroids, such as androgen and corticosteroids. Optimal focusing and resolution of all test steroids under a single buffer condition was realized by a dynamic pH junction-sweeping format using borate, pH 11.0 and bile acid surfactant with gamma-CD in the BGE, whereas the sample is devoid of surfactant at pH 8.0. The design of selective on-line focusing strategies in CE is highlighted by the analysis of microgram amounts of ethynyl estradiol derived from a female contraceptive pill extract using the dynamic pH junction method, which resulted in over a 100-fold enhancement in concentration sensitivity.  相似文献   

3.
We report on the investigation of electropreconcentration phenomena in micro-/nanofluidic devices integrating 100 μm long nanochannels using 2D COMSOL simulations based on the coupled Poisson–Nernst–Planck and Navier–Stokes system of equations. Our numerical model is used to demonstrate the influence of key governing parameters such as electrolyte concentration, surface charge density, and applied axial electric field on ion concentration polarization (ICP) dynamics in our system. Under sufficiently extreme surface-charge-governed transport conditions, ICP propagation is shown to enable various transient and stationary stacking and counter-flow gradient focusing mechanisms of anionic analytes. We resolve these spatiotemporal dynamics of analytes and electrolyte ICP over disparate time and length scales, and confirm previous findings that the greatest enhancement is observed when a system is tuned for analyte focusing at the charge, excluding microchannel, nanochannel electrical double layer (EDL) interface. Moreover, we demonstrate that such tuning can readily be achieved by including additional nanochannels oriented parallel to the electric field between two microchannels, effectively increasing the overall perm-selectivity and leading to enhanced focusing at the EDL interfaces. This approach shows promise in providing added control over the extent of ICP in electrokinetic systems, particularly under circumstances in which relatively weak ICP effects are observed using only a single channel.  相似文献   

4.
We report a capillary isoelectric focusing system based on a sequential injection method for simplified chemical mobilization. This system was coupled to an ion trap mass spectrometer with an electrokinetically pumped nanoelectrospray interface. The nanoelectrospray emitter employed an acidic sheath electrolyte. To simplify focusing and mobilization, a plug of ammonium hydroxide was first injected into the capillary, followed by a section of mixed sample and ampholyte. During focusing, the NH3H2O section worked as catholyte. As focusing progressed, the NH3H2O section was titrated to lower pH by the acidic sheath electrolyte. Chemical mobilization started automatically once the ammonium hydroxide was consumed by the acidic sheath flow electrolyte, which then acted as the mobilization solution. In this report, the lengths of the NH3H2O section and sample were optimized. With a 1 m long capillary, a relative short plug of the NH3H2O section (3 cm) produced both fast migration and reasonable separation resolution. The simplified capillary isoelectric focusing mass spectrometry system produced base peak intensity relative standard deviation of 8.5% and migration time relative standard deviation ≤0.6% for myoglobin and cytochrome C in triplicate runs.  相似文献   

5.
Mohan D  Lee CS 《Electrophoresis》2002,23(18):3160-3167
A microdialysis junction is employed as the interface for on-line coupling of capillary isoelectric focusing with transient isotachophoresis-zone electrophoresis in a two-dimensional separation system. Capillary isoelectric focusing not only provides high-resolution separation of tryptic peptides based on their differences in isoelectric point, but also potentially allows the analysis of low-abundance proteins with a typical concentration factor of 50-100 times. Carrier ampholytes, employed for the creation of a pH gradient during focusing, are further utilized as the leading electrolyte in the second separation dimension, transient isotachophoresis-zone electrophoresis. Many peptides which have the same isoelectric point would most likely have different charge-to-mass ratios, and thus different electrophoretic mobilities in zone electrophoresis. Two-dimensional separation of proteolytic peptides is demonstrated using standard proteins, including cytochrome c, ribonuclease A, and carbonic anhydrase II. The maximum peak capacity is estimated to be around approximately 1600 and can be significantly increased by simply increasing the capillary column length and manipulating the range of pH gradient in isoelectric focusing. In addition to enhanced separation efficiency and resolution, this two-dimensional electrokinetic separation system permits sensitive and comprehensive analysis of peptide fragments, especially when integrated with electrospray ionization mass spectrometry for peptide/protein identification.  相似文献   

6.
This study concentrates on development of instrumentation for focusing and separation of analytes in continuous flow. It is based on bidirectional ITP working in wide pH range with separation space of closed void channel of trapezoidal shape and continuous supply of sample. The novel instrumentation is working with electrolyte system formulated previously and on the contrary to devices currently available, it allows preparative separation and concentration of cationic, anionic, and amphoteric analytes simultaneously and in wide pH range. The formation of sharp edges at zone boundaries as well as low conductivity zones are avoided in suggested system and thus, local overheating is eliminated allowing for high current densities at initial stages of focusing. This results in high focusing speed and reduction of analysis time, which is particularly advantageous for separations performed in continuous flow systems. The closed void channel is designed to avoid basic obstacles related to liquid leakage, bubbles formation, contacts with electrodes, channel height and complicated assembling. The performance of designed instrumentation and focusing dynamics were tested by using colored low molecular mass pH indicators for local pH determination, focusing pattern, and completion. In addition, feasibility and separation efficiency were demonstrated by focusing of cytochrome C and myoglobin. The collection of fractions at instrument output allows for subsequent analysis and identification of sample components that are concentrated and conveniently in form of solution for further processing. Since the instrumentation operates with commercially available simple defined buffers and compounds without need of carrier ampholytes background, it is economically favorable.  相似文献   

7.
A rapid, simple method is proposed here for the identification of the experimental conditions that lead to satisfactory preparative-scale isoelectric focusing enantiomer separations in continuous free-flow electrophoretic units. The method first calls for the use of a commercially available, full-column imaging capillary electrophoretic system to find the background electrolyte composition that generates the largest pI difference between the bands of the enantiomers. The method then calls for the finding of the minimum residence time that permits full development of the pH gradient across the separation chamber of the continuous free-flow electrophoretic unit by measuring the pH in the sample-free carrier electrolyte fractions collected during these runs. Finally, the quality of the predicted preparative-scale separation is verified by analyzing the enantiomer-containing collected fractions by capillary electrophoresis using a 14-sulfated, single-isomer cyclodextrin as resolving agent. The pI difference values and production rate values observed in this work agree well with the literature values that were obtained by much more time-consuming methods.  相似文献   

8.
Huang T  Pawliszyn J 《Electrophoresis》2002,23(20):3504-3510
A simple microfabrication technique for the preparation of a tapered microchannel for thermally generated pH gradient isoelectric focusing (IEF) has been demonstrated. The tapered channel was cut into a plastic sheet (thickness was 120 microm), and the channel was closed by sandwiching the plastic sheet between two glass microscope slides. The length of the microchannel was 5 cm. The width of the separation channel was 0.4 mm at the narrow end and 4 mm at the wide end. The channel was coated with polyacrylamide to prevent electroosmotic flow (EOF) during focusing. Two electrolyte vials were mounted on top of each end of the channel with the wide end of the channel connected to the cathodic vial and the narrow to the anodic vial. The feasibility of the thermally generated pH gradient in a tapered channel was demonstrated. Important parameters that determined the feasibility of using a thermally generated pH gradient in a tapered channel were analyzed. Parameters to be optimized were control of EOF and hydrodynamic flow, selection of power supply mode and prevention of local overheating and air bubble formation. Tris-HCl buffer, which has a high pK(a) dependence with temperature, was used both to dissolve proteins and as the electrolyte. The thermally generated pH gradient separation of proteins was tested by focusing dog, cat and human hemoglobins with a whole column detection capillary IEF (CIEF) system.  相似文献   

9.
Dynamic pH junction is an online focusing method in CE based on the electrophoretic mobility difference of analytes in the sample matrix and the background electrolyte. An advantage of this method over the conventional CE is that the sensitivity can be significantly improved. By injecting a long sample plug in the capillary and focusing the analytes at the pH boundary between the background electrolyte and sample matrix, the LOD can be improved by 10–100 folds. The dynamic pH junction method can be easily coupled with ESI‐MS. In this work, we used this method for the analysis of microcystins (MCs). The detection limits and dynamic ranges were studied. The separation was optimized by adjusting the injection time, and concentrations and pH values of the background electrolyte. The optimization of analyte focusing leads to enhanced detection response compared to conventional injections, achieving 200–400 fold higher averaged peak heights for four microcystin (MC) variants. More importantly, this method was successfully used for the quantitative analysis of microcystins (MCs) in crude algae samples from natural water bodies, making it promising for practical applications.  相似文献   

10.
11.
Multicompartment electrolyzers with isoelectric Immobiline membranes are used for large-scale preparative protein purification. A series of isoelectric membranes, of defined pI values, is utilized for keeping any desired species isoelectric within each compartment of the electrolyzer. It is preferable to have electrode disks of the same surface area as the membranes for a proper performance of the instrument because electrolyte solutions of low conductivity are used. The use of Pt disks would be quite expensive; we therefore propose using Zr as a cathode and Ti/IrO2 as an anode in the electrodic compartments. This pairing of electrodes seems to give the same performance as Pt wires. Also, conventional isoelectric focusing, as well as isoelectric focusing in immobilized pH gradients, both requiring a good contact area between gel and electrodes, would benefit by using flat laminae of these metals as electrodes.  相似文献   

12.
The optimization of background electrolyte compositions for capillary zone electrophoresis in combination with conductivity detection focusing on maximal detector response is discussed. A theoretical approach pointing out the influence of the electrolyte co- and counter-ion mobilities on the detector signal has been developed. Using this model, running buffer compositions providing optimum S/N ratios for the selected analytes could be calculated. The results derived from these examinations have been verified by experimental investigations, namely the determination of inorganic and organic anionic solutes.  相似文献   

13.
Colored, low molecular weight pI markers have been developed for isoelectric focusing (IEF) in acidic pH range. Their isoelectric points (pIs) were determined by direct measurement of the pH of the focused bands after completion of IEF on polyacrylamide gels. The practicable suitability of the proposed pI markers as pI standards for IEF was tested by applying gel IEF. The acidic pH gradient was created either by commercial synthetic carrier ampholytes or by mixture of simple buffers consisting of acids (non-ampholytes) and ampholytic buffers. By applying simple acids, it was possible to extend the acidic pH range beyond those achievable with commercial synthetic carrier ampholytes. By using an experimental arrangement without electrode electrolyte reservoirs with electrodes creating the fixed end of the gel, the strongly acidic pH gradient was stable even for prolonged focusing time.  相似文献   

14.
Chen Y  Zhang L  Cai Z  Chen G 《The Analyst》2011,136(9):1852-1858
In this paper, we developed a simple and effective on-line focusing technique combining dynamic pH junction and sweeping by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. Dynamic pH junction-sweeping is defined when the sample has a different buffer pH (dynamic pH junction condition) and is devoid of micelles (sweeping condition) relative to the background electrolyte (BGE). This hyphenated focusing mode was applied to the sensitive and selective focusing of four dipeptides: Tyr-Phe, Tyr-Leu, Trp-Gly, and Ala-Gln. Picomolar detectability of these dipeptides by CE-LIF detection was demonstrated through effective focusing of large sample volumes (up to 39% capillary length) using the dual pH junction-sweeping focusing mode. 25 mmol L(-1) sodium dihydrogen phosphate, pH 2.5 was used as the sample matrix, and 100 mmol L(-1) borate, 21 mmol L(-1) sodium dodecylsulfate (SDS), 16 mmol L(-1) Brij35, pH 9.0 as the background solution (BGS). The concentration detection limits (S/N = 3) of the four dipeptides were in the range of 1.0-5.0 pmol L(-1). The developed method has been successfully used for the determination of dipeptides in human serum samples.  相似文献   

15.
This article describes for the first time the combination of electrophoretic focusing on inverse electromigration dispersion (EMD) gradient, a new separation principle described in 2010, with electrospray-ionization (ESI) mass spectrometric detection. The separation of analytes along the electromigrating EMD profile proceeds so that each analyte is focused and concentrated within the profile at a particular position given by its pKa and ionic mobility. The proposed methodology combines this principle with the transport of the focused zones to the capillary end by superimposed electromigration, electroosmotic flow and ESI suction, and their detection by the MS detector. The designed electrolyte system based on maleic acid and 2,6-lutidine is suitable to create an inverse EMD gradient of required properties and its components are volatile enough to be compatible with the ESI interface. The characteristic properties of the proposed electrolyte system and of the formed inverse gradient are discussed in detail using calculated diagrams and computer simulations. It is shown that the system is surprisingly robust and allows sensitive analyses of trace amounts of weak acids in the pKa range between approx. 6 and 9. As a first practical application of electrophoretic focusing on inverse EMD gradient, the analysis of several sulfonamides in waters is reported. It demonstrates the potential of the developed methodology for fast and high-sensitivity analyses of ionic trace analytes, with reached LODs around 3 × 10−9 M (0.8 ng mL−1) of sulfonamides in spiked drinking water without any sample pretreatment.  相似文献   

16.
The separation of a complex mixture of inorganic and organic anions by ion chromatography–capillary electrophoresis using a cationic polymer added to the background electrolyte and indirect UV detection has been studied. The addition of unmodified polymer to an electrolyte suitable for indirect detection resulted in the appearance of a system peak due to the counter-anion on the polymer and while the position of the analytes relative to this system peak could be changed, this was found to be an unacceptable approach for mixtures of large numbers of analytes. Although conversion of the polymer to replace the counter-ion with the indirect UV detection probe ion simplified the system, this approach restricted the flexibility of the system because the probe and polymer concentration were necessarily linked. This limitation could be overcome by selecting the appropriate type of probe ion, with probes having a low ion-exchange selectivity coefficient providing greater retention of analytes than probes with a high ion-exchange selectivity coefficient. Three electrolyte systems with different probes (benzoate, chromate and phthalate) were modelled using a previously derived migration equation and this was used to optimise the electrolyte composition to enable the separation of a mixture of 24 inorganic and organic anions within 7 min. The electrolyte composition was then optimised for the analysis of anions in Bayer liquor with the final separation selectivity being substantially improved for selected key analytes.  相似文献   

17.
The separation of the basic drug lidocaine and six of its metabolites has been investigated both by using volatile aqueous electrolyte system, at low pH and by employing non-aqueous electrolyte systems. In aqueous systems, the best separation of the compounds under the investigated conditions was achieved by using the electrolyte 60 mM trifluoroacetic acid (TFA)/triethylamine (TEA) at pH 2.5 containing 15% methanol. With this electrolyte, all seven compounds were well separated with high efficiency and migration time repeatability. The separations with bare fused-silica capillaries and polyacrylamide-coated capillaries were compared with higher separation efficiency with the latter. On the other hand, near baseline separation of all the seven compounds was also obtained by employing the non-aqueous electrolyte, 40 mM ammonium acetate in methanol and TFA (99:1, v/v), with comparable migration time repeatability but lower separation efficiency relative to the aqueous system.  相似文献   

18.
Analytical aspects of carrier ampholyte-free isoelectric focusing   总被引:2,自引:0,他引:2  
The applicability of carrier ampholyte-free isoelectric focusing (CAF-IEF) for analyses of ampholytes is demonstrated. The suggested method is based on the principle of both side regulated ionic matrix in CAF-IEF. A sharp step of pH is created in the column filled with a sample dissolved in a background electrolyte by influence of current and solvolytic fluxes. Here, ampholytes are focused upon. The magnitude of the step, its velocity and direction of its movement can be regulated electrically. In this manner, favorable separation properties of the system can be set up, even during the run. This brings several advantages over conventional methods. The principles of the separation can be easily changed, permitting selective pre-concentration (trapping) of minor components by processing large amounts of a sample to be preformed, effective isotachophoresis or IEF pre-separation and final electrophoretic analysis in one run. Advantages of these combinations are discussed together with the right choice of the working electrolyte. A 1000-fold increase in amount of substance in a column can be achieved for both isotachophoresis and capillary zone electrophoresis combined with CAF-IEF pre-concentration at reasonable working conditions. It enables a limit of detection at the nmol/l level with a concentration factor of about 10(7) to be reached.  相似文献   

19.
J.P. Zheng  P.C. Goonetilleke  D. Roy 《Talanta》2009,78(3):1056-7537
Carbon nanotube (CNT) electrodes in combination with ionic liquid (IL) electrolytes are potentially important for energy storage systems. We report electrochemical investigation of such a system involving a paper-electrode of multi-wall CNT (MWCNT) in the IL of 1-ethyl-3-methyl imidazolium ethylsulfate (EMIM-EtSO4). Our study concentrates on the analytical aspects of cyclic voltammetry (CV) to probe the double layer capacitance of these relatively unconventional systems (that involve rather large charge-discharge time constants). Both theoretical and experimental aspects of CV for such systems are discussed, focusing in particular, on the effects of Faradaic side-reactions, electrolyte resistance and voltage scan speeds. The results are analyzed using an electrode equivalent circuit (EEC) model, demonstrating a method to account for the typical artifacts expected in CV of CNT-IL interfaces.  相似文献   

20.
Kubán P  Kubán P  Kubán V 《Electrophoresis》2003,24(12-13):1935-1943
A simple and inexpensive flow injection-capillary electrophoresis (FI-CE) system with contactless conductivity detection (CCD) for automated quantitative analysis of chloride, nitrate, and sulfate in various water samples is demonstrated. A glass bottle containing the background electrolyte that is raised above the FI-CE interface generates a pulse-free, highly reproducible flow of the electrolyte through the FI-CE interface. The system operates at a flow rate of 300 microLmin(-1) with an injection volume of only 4 microL. The repeatability of peak areas (n = 18) was better than 0.81% RSD and the sample throughput was 90 samples per hour using the background electrolyte containing 12 mM L-histidine adjusted to pH 4.00 with acetic acid. The limits of detection were better than 125 microgL(-1) and were comparable to those obtained by conventional CE systems with CCD. Various calibration methods for FI-CE system with electrokinetic injection were tested and their suitability for the analysis of anions in real samples was evaluated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号