首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel concept for stable coating in capillary electrophoresis, based on recrystallization of surface layer proteins on hydrophobized fused silica capillaries, was demonstrated. Surface layer protein A (SlpA) from Lactobacillus acidophilus bacteria was extracted, purified and used for coating pre-silanized glass substrates presenting different surface wettabilities (either hydrophobic or hydrophilic). Contact angle determination on SlpA-coated hydrophobic silica slides showed that the surfaces turned to hydrophilic after coating (53 ± 5°), due to a protein monolayer formation by protein-surface hydrophobic interactions. Visualization by atomic force microscopy demonstrated the presence of a SlpA layer on methylated silica slides displaying a surface roughness of 0.44 ± 0.02 nm. Additionally, a protein layer was visualized by fluorescence microscopy in methylated silica capillaries coated with SlpA and fluorescein isothiocyanate-labeled. The SlpA-coating showed an outstanding stability, even after treatment with 20 mM NaOH (pH 12.3). The electroosmotic flow in coated capillaries showed a partial suppression at pH 7.50 (3.8 ± 0.5 10−9 m2 V−1 s−1) when compared with unmodified fused silica (5.9 ± 0.1 10−8 m2 V−1 s−1). To demonstrate the potential of this novel coating, the SlpA-coated capillaries were applied for the first time for electrophoretic separation, and proved to be very suitable for the isotachophoretic separation of lipoproteins in human serum. The separations showed a high degree of repeatability (absolute migration times with 1.1–1.8% coefficient-of-variation (CV) within a day) and 2–3% CV inter-capillary reproducibility. The capillaries were stable for more than 100 runs at pH 9.40, and showed to be an exceptional alternative for challenging electrophoretic separations at long-term use.  相似文献   

2.
Ionic substances with melting points close to room temperature are referred to as ionic liquids. Because ionic liquids are environmentally benign and are good solvents for a wide range of both organic and inorganic materials, interest for their potential uses in different chemical processes is increasing. In this paper, a capillary electrophoretic method for the analysis of basic proteins including lysozyme, cytochrome c, trypsinoge, and α-chymotyypsinogen A is reported. The method, in which 1-alkyl-3-methylimidazolium-based ionic liquids are used as the running electrolytes, leads to a surface charge reversal on the capillary wall. The effects of the alkyl group, imidazolium counterion, and the concentration of the ionic liquids were discussed. The optimum buffer system was a 90 mM 1-ethyl-3-methylimidazolium tetrafluoroborate (1E-3MI-TFB) solution. The applied voltage was −15 kV and detection was performed by monitoring absorbance at 240 nm. Baseline separation, high efficiencies, and symmetrical peaks of four proteins were obtained. The R.S.D. values of migration times and peak areas were <0.68 and <3.0%, respectively. The separation mechanism seems to involve association between the imidazolium cations and the proteins.  相似文献   

3.
Spermine-graft-dextran (Spe-g-Dex) copolymer was synthesized and used as a non-covalent coating for the separation of proteins and neurotransmitters by capillary electrophoresis. The coating was obtained via flushing the capillary with 1.0% Spe-g-Dex copolymer solution for 2 min. Electroosmotic flow (EOF) was strongly suppressed, ranging from −1.60 × 10−9 to 3.65 × 10−9 m2 V−1 s−1. Effect of experimental conditions, such as the copolymer concentration, the concentration and pH of the background electrolyte (BGE), on the Spe-g-Dex coating was investigated. Separation of lysozyme, cytochrome c, ribonuclease A and α-chymotrypsinogen yielded high separation efficiencies ranging from 141 000 to 303 000 plates/m and recoveries from 85.4% to 98.3% at pH 4.0 (284.0 mM sodium acetate–acetic acid buffer, I = 50 mM). Run-to-run repeatabilities and day-to-day, and capillary-to-capillary reproducibilities were all below 1.7%. In addition, Spe-g-Dex coating allowed the successful separation of five neurotransmitters, 5-hydroxytryptamine, dopamine, epinephrine, isoprenaline, dobuamine at pH 4.0 with high separation efficiencies of 290 000–449 000 plates/m.  相似文献   

4.
δ-Gluconolactone was covalently coupled to aminopropyl derivatized capillary,which created hydrophilic brushes on the inner wall of the capillary.The coated capillary was shown to generate a stable electroosmotic flow(EOF) in the investigated pH range of 2.0-9.0 and to suppress effectively the adsorption of proteins.And it enabled separation of some biopolymer mixtures including basic proteins,DNA and tryptic digested bovine serum albumin(BSA) within 15 min with efficiencies up to 450,000 plates/m.The in...  相似文献   

5.
Surfactants such as dioctadecyldimethylammonium bromide (DODAB) form semi-permanent coatings that effectively prevent adsorption of cationic proteins onto the fused silica capillary in capillary electrophoresis (CE). The bilayer coating is generated by flushing the capillary with a 0.1 mM surfactant solution. However, formation of the bilayer is strongly dependent on the coating electrolyte. The effect of counter-ions, electrolyte concentrations and buffer co-ions were monitored based on: the separation of basic model proteins; the adsorption kinetics of DODA+ onto fused silica; and dynamic light scattering (DLS) to determine vesicle size. Low concentrations (≤10.0 mM) and/or weakly associating buffers such as phosphate (pH 3.0), acetate (pH 4.0) and chloride should be used for DODAB coating solutions. Dissolving the surfactant in strongly associating electrolyte, such as phosphate at pH 7.0, results in poor coating of the capillary surface. Effective cationic bilayer coatings are formed if the buffer conditions favor formation of vesicles with diameters < 300 nm. Monitoring turbidity at 400 nm provides a convenient means of verifying vesicle diameter variation of <5 nm; that is, that the coating solution is effective.  相似文献   

6.
Liu H  Shi R  Wan W  Yang R  Wang Y 《Electrophoresis》2008,29(13):2812-2819
A series of well-defined diblock copolymers, poly(ethylene oxide)-block-poly(4-vinylpyridine) (PEO-b-P4VP) used as physical coating of capillaries, were synthesized by atom transfer radical polymerization (ATRP). EOF measurement results showed that all synthesized PEO-b-P4VP diblock copolymer-coated capillaries in this report could suppress EOF effectively compared to the bare fused-silica capillaries, and efficient separations of basic proteins were achieved. The effects of the molecular weight of P4VP block in PEO-b-P4VP and buffer pH on the separation of basic proteins for CE were investigated in detail. Moreover, the relationships between morphologies of PEO-b-P4VP diblock copolymers in buffer, which were studied by transmission electron microscopy, and the separation efficiencies of basic protein with PEO-b-P4VP diblock copolymers coatings were discussed.  相似文献   

7.
This paper presents a capillary electrophoresis method, developed for the detection, in human urine, of beta‐adrenergic agents and phenolalkylamines. The electrophoretic separation is achieved in less than 10 min and is based on the use of CEofix kit, for the dynamic capillary coating. The effects of accelerator buffer pH and separation voltage were investigated. The optimum buffer pH was found to be 2.5 for beta2‐agonists and 6.2 for beta‐blockers and phenoalkylamines with a separation voltage of 15 kV. Urine samples spiked with the compounds here studied were treated according to the standard procedure (SPE and evaporation to dryness) and analyzed by CE interfaced with an UV diode‐array, set at 195 and 210 nm. The quantitative validation results, obtained analyzing samples at three different concentrations, show a good precision of peak areas that do not exceed 5% for intra‐day assays and 10% for inter‐day assays. Good linearity (r2 > 0.995) was obtained within the 50–500 ng/mL concentration range. The qualitative validation data show a relative migration times (MTs) variation lower than 1%. The analytes were clearly distinguishable in urine, with LOD and LOQ in the range of 10–80 and 40–100 ng/mL, respectively.  相似文献   

8.
The article describes synthesis and thermally triggered self‐assembly of a Poly (ethylene oxide)‐block‐poly (N‐insopropylacrylamide) (PEO‐b‐PNIPAm) in aqueous medium. At rt, the polymer remains as unimer, however, at lower critical solution temperature (LCST) of PNIPAm (32 °C), it forms a rather large undefined aggregate which at slightly elevated temperature (~40 °C) converges to well defined polymersome structure (Critical aggregation concentration = 0.45 mg/mL) with hydrodynamic diameter of 40–50 nm. By lowering the temperature, initial swelling of the compact vesicle followed by reversible disassembly to unimer was noticed. The polymersome exhibits encapsulation ability to a hydrophilic dye Calcein which can be spontaneously released by lowering the temperature below cloud point. Likewise a hydrophobic dye namely 8‐Anilino‐1‐naphthalenesulfonic acid (ANS) can also be encapsulated and released by thermal trigger. Detail photoluminescence studies reveal ANS dye can be used as a generalized probe molecule for detecting LCST of a thermoresponsive polymer by “fluorescence on” above LCST even by cursory observation. © 2015 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2015 , 53, 2444–2451  相似文献   

9.
A new capillary electrophoretic (CE) method was developed for the rapid and simple determination of glutaraldehyde in photographic developing solutions. The proposed system is based on the selective pre-capillary derivatization of glutaraldehyde with sulfite and CE determination of anionic glutaraldehyde-bisulfite adduct formed. Since the developing solutions contain large amounts of sulfite ions, the only procedure required for derivatization is a dilution of the sample with carrier electrolyte. For separations of sulfite, acetate, glutaraldehyde-bisulfite and hydroquinone sulfonate anions, capillaries coated with poly(diallyldimethylammonium chloride) prior to analysis were used. Separation of four anions was accomplished in less than 3 min in 5 mmol l−1p-hydroxybenzoate-imidazole (p-HB) electrolyte at pH 6.0 using indirect UV detection at 254 nm. The optimal conditions for the derivatization reaction were established by varying concentration of sulfite, pH and reaction time. The recovery tests established for photographic developer samples were within the range 94.0-98.4%.  相似文献   

10.
A brush-like copolymer consisting of poly(ethylene glycol) methyl ether methacrylate and N,N-dimethylacrylamide (PEGMA-DMA) was synthesized and used as a novel static physically adsorbed coating for protein separation by capillary electrophoresis for the first time, in order to stabilize electroosmotic flow (EOF) and suppress adsorption of proteins onto the capillary wall. Very stable and low EOF was obtained in PEGMA-DMA-coated capillary at pH 2.2-7.8. The effects of molar ratio of PEGMA to DMA, copolymer molecular mass, and pH on the separation of basic proteins were discussed. A comparative study of bare capillary with PEGMA-DMA-coated capillary for protein separation was also performed. The basic proteins could be well separated in PEGMA-DMA-coated capillary over the investigated pH range of 2.8-6.8 with good repeatability and high separation efficiency because the copolymer coating combines good protein-resistant property of PEG side chains with excellent coating ability of PDMA-contained backbone. Finally, the coating was successfully applied to the fast separation of other protein samples, such as protein mixture and egg white, which reveals that it is a potential coating for further proteomics analysis.  相似文献   

11.
《Electrophoresis》2017,38(24):3104-3110
Overcoming proteins adsorption on the inner surface of capillary has attracted increasing attention recently. By using the unique photochemistry reaction of diazoresin (DR), a new covalent capillary coating was prepared on the fused‐silica capillary through layer‐by‐layer self‐assembly of DR with polyglycerol (PG) dendrimer. The separation performance of covalently DR/PG‐dendrimer coated capillary noticeably exceeded the bare capillary and the noncovalently linked DR/PG‐dendrimer capillary. A baseline separation of lysozyme, myoglobin, bovine serum albumin, and ribonuclease A was achieved using CE within 20 min. Besides, the covalently linked DR/PG‐dendrimer coating has the remarkable stability and reproducibility. Especially, compared with the traditional method which use highly toxic and moisture‐sensitive silane coupling agent, this method seems to be a simple and environmental friendly way to prepare the covalently coated capillaries for CE.  相似文献   

12.
Huang X  Wang Q  Huang B 《Talanta》2006,69(2):463-468
A coated capillary modified with a coupled chitosan (COCH) was developed by using a simple and fast (60 min) process that could be easily automated in capillary electrophoresis instrument. The COCH coating was achieved by first attaching chitosan to the capillary inner wall, and then coupling with glutaraldehyde, and rinsing chitosan again to react with glutaraldehyde. The COCH coating was stable and showed amphoteric character over the pH range of 1.8-12.0. When the pH value was lower than 4.5, the capillary surface possessed positive charges, which caused a reversal in the direction of the electroosmotic flow (EOF). The normal EOF direction could be obtained when the pH value was higher than 4.5. The COCH coating showed strong stability against 0.1 mol/L HCl, 0.1 mol/L NaOH and other solvents compared with conventional chitosan coating. The relative standard deviation of the run-to-run, day-to-day and capillary-to-capillary coating was all below 2% for the determination of EOF. The COCH-modified capillary was applied to acidic and basic proteins analyses and high efficiency could be attained. The comparison between unmodified capillary, chitosan-modified and COCH-modified capillary for the separation of real sample, extract from Elaphglossum yoshinagae with water, was also studied. Better results could be obtained on COCH-modified capillary than the other two capillaries.  相似文献   

13.
We present a method for finely adjustable electroosmotic flow (EOF) velocity in cathodic direction for the optimization of separations in capillary electrophoresis. To this end, we use surface modification of the separation fused silica capillary by the covalently attached copolymer of acrylamide (AM) and 2-acrylamido-2-methyl-1-propanesulfonate (AMPS), that is, poly(AM-co-AMPS) or PAMAMPS. Coatings were formed by the in-capillary polymerization of a mixture of the neutral AM and anionic AMPS monomers premixed in various ratios in order to control the charge density of the copolymer. EOF mobility varies in the 0 to ∼40 × 10−9 m2 V−1 s−1 interval for PAMAMPS coatings ranging from 0 to 60 mol.% of charged AMPS monomer. For EOF in PAMAMPS-treated capillaries, we observed (i) a negligible dependence on pH in the 2–10 interval, (ii) a minor variance among background electrolytes (BGEs) in function of their components and (iii) its standard decrease with increasing ionic strength of the BGE. Interest in variable cathodic EOF was demonstrated by the amelioration of separation of two kinds of isomeric anionic analytes, that is, monosaccharides phosphates and helquat enantiomers, in counter-EOF mode.  相似文献   

14.
《Electrophoresis》2017,38(3-4):477-485
An indirect UV detection method based on CE was developed and validated to determinate 12 metal cations, including alkali, alkaline earth, transition metal, and ammonium. In this paper, a new electrolyte system (pH 4.22) contained 20 mM benzimidazole (as co‐ion), 75 mM acetic acid (as a counter‐ion) as well as 0.6 mM 18‐crown‐6 ether was applied. The metal ions were completely separated within 8 min under hydrodynamic mode injection with a running voltage of 20 kV at 25 ± 0.1°C. Additional use of the dynamic double coating method enabled to get an excellent repeatability of migration times and quantitative parameters for all analytes. The repeatability of migration times for analytes were less than 0.9% and peak areas and peak heights ranged from 3.7 to 7.2 and 3.9 to 7.7%, respectively (n = 6). The proposed technique proved to be definitely faster and less expensive in comparison to currently employed methods. In this work, we discuss also the linear range, method detection limits as well as precision and accuracy. The applicability of the elaborated method was authenticated by the quantification of metal ions in commercially available mineral water, tap water, and selected medical injection samples.  相似文献   

15.
Two new methods of inner capillary coating with poly(vinyl alcohol) (PVAL) have been investigated and evaluated by performing DNA capillary electrophoresis (CE) using PVAL as a separation medium and by measuring the electroosmotic flow (EOF) mobility. The treatment of capillaries with a silanol-group modified PVAL (PVAL-Si) has been found to give good coating effects for improving the resolution of DNA CE and for reducing the EOF. This coating must be effectively achieved by combining the adsorptive property of PVAL chains onto silica with the reaction between the silanol groups of PVAL-Si and the silica surface. The adsorption of PVAL onto silica has been observed by using atomic force microscopy (AFM) for PVAL-Si as well as for a nonmodified PVAL as a control. The coating with PVAL that links to the capillary wall surface with more hydrolytically stable bonding, -Si-C-, has been formed by performing the Grignard reaction, followed by in-capillary polymerization of vinyl acetate (VAc) and hydrolysis. This coating has been found to be effective for improving the resolution of DNA CE and for reducing the EOF.  相似文献   

16.
Novel double hydrophilic block copolymers with amine pendant chains were synthesized by polymerization of 4-vinyl benzylamine hydrochloric salt using 4,4′-azo-bis[4-cyanopentanoate poly(ethylene glycol) ester] as macroazoinitiator. The structures of the copolymers were characterized by ^1H NMR, FTIR spectra and acid-base titration, GPC-MALS techniques.  相似文献   

17.
Protein adsorption to the inner capillary wall hinders the use of kinetic capillary electrophoresis (KCE) when studying noncovalent protein-ligand interactions. Permanent and dynamic capillary coatings have been previously reported to alleviate much of the problems associated with protein adsorption. The characteristic limitations associated with permanent and dynamic coatings motivated us to look at a third type of coating - semipermanent. Here, we demonstrate that a semipermanent capillary coating, designed by Lucy and co-workers, comprised of dioctadecyldimethylammonium bromide (DODAB) and polyoxyethylene (POE) stearate, greatly reduces protein adsorption at physiological pH - a necessary requirement for KCE. The coating (i) does not inhibit protein-DNA complex formation, (ii) prevents the adsorption of the analytes, and (iii) supports an electoosmotic flow required for many applications of KCE. The coating was tested in three physiological buffers using a well-known DNA aptamer and four proteins that severely bind to bare silica capillaries as standards. For every protein, a condition was found under which the semipermanent coating effectively suppresses protein adhesion. While no coating can completely prevent the adsorption of all proteins, our findings suggest that the DODAB/POE stearate coating can have a broad impact on CE at large, as it prevents the absorption of several well studied, highly adhesive proteins at physiological pH.  相似文献   

18.
CE is a promising technique for the analysis of glycosylated proteins, especially at the intact level. In the present study, the utility of CE for the separation of protein glycoforms is developed by using methyl chitosan as capillary coating. Methyl chitosan, in contrast to the polymers commonly used for coating, bears different types of amine groups, allowing for tunable charge states for various applications. The addition of methyl chitosan in background electrolyte can modulate the EOF and improve the separation performance. The methyl chitosan-coated capillary provided good separation of acidic or basic glycosylated proteins. Five ribonuclease B glycoforms were resolved by CE in less than 18 min, and the profile was essentially in agreement with that obtained by MALDI-TOF MS. The recombinant human erythropoietin glycoforms were well separated within 9 min. The developed method shows a great potential in protein glycoform analysis.  相似文献   

19.
A new type of block copolymer, which was synthesized by styrene and maleic anhydride, P(MAn‐alt‐St)119‐b‐PSt558, was successfully developed as the capillary coatings in open tubular CEC. It is interesting that the covalently bonded coatings are porous and the coatings can play the role of surfactants in the separation of aromatic amines when the buffer solution was composed of 30.0 mM ammonium acetate at pH 7.7 with 20% THF. Thus, successful baseline separation of five kinds of aromatic amines has been achieved. As validated by both artificially prepared solutions of aromatic amines and four real samples of commercially available permanent hair dyes, this proposed method was successfully applicable to the quantitative analysis of p‐phenylenediamine (PPD) and o‐phenylenediamine (OPD) ingredients in these commercial products, with a linear range between 8.3 μM and 6.0 mM, correlation coefficient above 0.990 and recovery between 83.5 and 110.9%. The detection limit obtained from calculations based on signal‐to‐noise ratio (S/N=3) was 4.2 μM for PPD and 6.0 μM for OPD, respectively. Furthermore, the role of the surfactants played by the block copolymer coatings has been primarily explored.  相似文献   

20.
Y Li  L Qi  J Qiao  Y Shen  H Yan  P Xin  H Ma 《Electrophoresis》2012,33(13):2019-2027
A novel series of diblock copolymers, poly(butyl methacrylate)(n) -block-poly(glycidyl methacrylate)(m) [P(BMA)(n) -b-P(GMA)(m) ], were synthesized by atom transfer radical polymerization and developed as covalent coating of capillaries. The excellent performance of this coating in separation of three 1,4-dihydropyridines (DHPs) derivatives (amlodipine, nicardipine, nitrendipine) was achieved when the diblock copolymers self-assembled into micelles, which was confirmed by transmission electron microscopy, dynamic light scattering, and atom force microscopy. Meanwhile, the effects of block ratio n/m, pH value, buffer concentration, and organic solvents on the separation of 1,4-DHPs were investigated in detail. Then, the relationship between the morphologies of copolymers and the separation resolutions of 1,4-DHPs was discussed. Furthermore, the proposed method exhibited good run-to-run and column-to-column precision with relative standard deviations of electroosmotic flow less than 3.0%. It was also validated with linearity of three 1,4-DHPs in the range of 0.01-1.80 mM (r(2) ≥ 99.7%), efficient recovery (94-103%), and good repeatability (≤ 3.8%). In addition, three 1,4-DHPs were successfully separated in the spiked human serum sample, which indicated the potential utility of this method in biological sample analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号