首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A highly selective lead-imprinted polymer was synthesized via a thermal precipitation polymerization technique based on a terpyridine-based ligand as the complexing agent. The synthesized polymer was successfully incorporated in a graphite paste electrode (GPE) as the recognition element for lead ion (Pb2+). Differential pulse anodic stripping voltammetry (DPASV) technique was used to transduce the binding events at the modified electrode. The imprinted polymer nanoparticles (IP-NPs) were synthesized by precipitation polymerization of ethylene glycol dimethacrylate as the cross-linker, 2,2′-azobisisobutyronitrile as the free radical initiator and 2,2′:6′,6″-terpyridine (terpy) as the recognition element. The sensing procedure is based on the accumulation of lead ions at ??1.0 V vs. Ag/AgCl. Afterward, the DPV was recorded by the sweeping potential in a positive direction to oxidize the accumulated ions, leading to the appearance of a significant anodic peak. The constructed IIP–GPE revealed a linear response toward Pb2+ over the concentration range from 0.4 to 10 nM (with the sensitivity of 693.95 nA nM?1 cm?2) and 10 nM to 1.0 µM (with the sensitivity of 580.25 µA µM?1 cm?2). The limit of detection (LOD) was evaluated to be 0.11 nM (for S/N?=?3). The accuracy of the sensor was explored by analysis of a quality control material (QCMs, Seronorm? urine REF NO 1011645) and different water samples. Selectivity studies showed no particular interference for detection of Pb(II).  相似文献   

2.
In this research work, a new approach is developed for the extractive determination of chromium. The principle of this approach is based on the complexation reaction between 4-(4?-chlorobenzylideneimino)-3-methyl-5-mercapto-1,2,4-triazole (CBIMMT) in dichloromethane as a complexing reagent and chromium(III) in presence of potassium iodide to form a yellow coloured complex at room temperature. The 1:2:2 [Cr(III)-CBIMMT-iodide] ternary complex was quantitatively extracted in dichloromethane from 2.5 mol L?1 of hydrochloric acid medium which showed maximum absorption intensity at λmax 411 nm and was stable for more than 72 h. The values of molar absorption coefficient and Sandell’s sensitivity of the complex were found to be 0.7019 × 104 L mol?1 cm?1 and 0.00748 µg cm?2, respectively. The system adheres to Beer’s law from 1.5 to 6.0 µg mL?1; however, Ringbom’s plot suggests optimal concentration range was 1.8–5.8 µg mL?1. The limit of detection and limit of quantification of the approach is 0.26 and 0.79 µg mL?1. This approach was successfully used for the determination of chromium from wastewater effluents from the tannery industries (Kolhapur, MS, India), alloy samples and for separation of it from synthetic mixtures. The present experimental approach is apparently much simpler than the conventional method comprising multistep processes.  相似文献   

3.
A simple and fast voltammetric method based on a new electrode composed of carbon paste electrode/bifunctional hybrid ion imprinted polymer (CPE/IIP) was developed for the quantification of Cd2+ in water samples. The voltammetric measurements by Differential Pulse Voltammetry were performed by using CPE containing 11.0 mg of IIP under phosphate buffer solution at concentration 0.1 mol L?1 and pH 6.5. The electrochemical method was carried out by Cd2+ preconcentration at ?1.2 V during 210 s, followed by anodic stripping. The performance of IIP towards Cd2+ determination was evaluated by comparison to non-imprinted polymer, whose detectability of IIP was much higher (45%). The sensitivity of the sensor was found to be 0.0105 µA/µg L?1. The limits of detection and limits of quantification were found to be 4.95 μg L?1 and 16.4 μg L?1, respectively. The developed method was successfully applied to Cd2+ determination in mineral, tap and lake water samples, whose results are in agreement with thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) used as reference analytical technique. According to achieved results, the developed method can be used for routine analysis of quality control of water samples from different sources.  相似文献   

4.
A sensitive and reliable method is described for the determination of total Sb(III,?V) at traces levels by Osteryoung square-wave anodic stripping voltammery (OSWASV). This method is based on the co-deposition of Sb(III,?V) with Bi(III) onto an edge-plane pyrolytic graphite substrate at an accumulation step. OSWASV studies indicated that the co-deposited antimony was oxidised with anodic scans to give an enhanced anodic peak at about 450?mV vs. Ag/AgCl (sat. KCl). The anodic stripping peak current was directly proportional to the total concentration of antimony in the ranges of 0.01–0.10?µg?L?1, 0.10–1.0?µg?L?1 and 1.0–18.0?µg?L?1 with correlation coefficient higher than 0.995 when 2.0?mol?L?1 hydrochloric acid was used. The detection limits calculated as S/N?=?3 was 5.0?ng?L?1 in 2.0?mol?L?1 hydrochloric acid at 180?s deposition time. The relative standard deviation was 5% (n?=?6) at 0.10?µg?L?1 level of antimony. The analytical results demonstrate that the proposed method is applicable to analyses of real water samples.  相似文献   

5.
This work presents the results obtained on the construction of a potentiometric ion‐selective electrode based on a polypyrrole (PPy) selective membrane to quantify the benzoate ion in nonalcoholic beverages. The electrode modification with benzoate (Benz?1) ion doped‐Ppy was carried out under an imposed potential, while the electrosynthesis optimization was undertaken using the modified Simplex method, such that the film’s sensitivity was maximized toward the benzoate ion. The maximum sensitivity recorded was ?52.02±1.55 mV/decade [Benz?1] using a graphite powder‐araldite resin composite electrode. During the modified electrode’s characterization it was found out that the response and drift were relatively short, namely 2 min and 0.4 mV min?1 respectively, within the 7 to 9 pH range, exhibiting a detection limit of 7×10?4 mol L?1 and a quantification range of 3×10?3 at 10?1 mol L?1. Selectivity coefficients were evaluated with the Matched Potential Method obtaining in all cases values much less than 1. The benzoate concentration in commercially available juices and sweetened beverages was evaluated comparing the results obtained with the proposed ion‐selective electrode and those of HPLC, the usually accepted technique. A statistical analysis of the results led to the conclusion that there exists no meaningful difference between the results obtained with both techniques, which shows the usefulness of the ion‐selective electrode to proceed with the quantification in real samples.  相似文献   

6.
This paper describes the development of a methodology for quantification of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments by anodic stripping voltammetry (ASV) automated by Sequential Injection Analysis (SIA) using a graphite screen printed sensor modified with mercury. Determinations were made by standard addition automated by the SIA system. The limits of detection and quantification were, respectively, 1.3 and 4.3 µg L?1 for Cu(II), 1.4 and 4.6 µg L?1 for Pb(II), 0.6 and 1.8 µg L?1 for Cd(II) and 4.2 and 14 µg L?1 for Zn(II). These limits were obtained for a sample volume of 1000 µL, flow rate of 10 µL s?1 (during the deposition step), and utilizing 3 flow reversals (volume of reversion=950 µL), totalizing a deposition time of 315 s. The potentiostat worked synchronically with the SIA system applying the conditioning potential of ?0.1 V vs. pseudo reference of Ag (100 s), deposition potential of ?1.0 V for Cu(II), Pb(II) and Cd(II) or ?1,3 V for Zn(II), square wave frequency of 100 Hz, potential step of 6 mV and pulse height of 40 mV. For quantification of Zn(II) in sediment extracts, deposition of Ga0 on the working electrode was necessary to avoid the formation of intermetallic between Zn0 and Cu0. The accuracy of the method was assessed by spike and recovery experiments in water samples which resulted recovery rates near 100 % of the spiked concentrations. Recoveries of concentrations in the certified sediment sample CRM‐701 undergoing the three steps sequential extraction procedure of BCR varied from 71.7 % for Zn(II) in the acetic acid extract to 112.4 % for Cu(II) in the oxidisable fraction, confirming that the standard addition approach corrected the matrix effects in the complex samples of sediment extracts.  相似文献   

7.
We describe a new and promising type of selenium film electrode for anodic stripping voltammetry. This method is based on formation of copper selenide onto an in-situ formed selenium-film carbon electrode, this followed by Osteryoung square-wave anodic stripping voltammetry. Copper(II) is also in-situ electroplated in a test solution containing 0.01 mol L-1 hydrochloric acid, 0.05 mol L?1 potassium chloride and 500 µg L?1 Se(IV) at a deposition potential of ?300 mV. The well-defined anodic peak current observed at about 200 mV is directly proportional to the Cu(II) concentration over the range from 1.0 to 100 µg L?1 under the optimized conditions. The detection limit (three sigma level) is 0.2 µg L?1 Cu(II) at 180 s deposition time. Relatively less interferences are shown from most of metal ions except for antimony(III). The method can be applied to analyses of river water and oyster tissue with good accuracy.  相似文献   

8.
Direct electron transfer of immobilized copper, zinc‐superoxide dismutase (SOD) onto electrodeposited nickel‐oxide (NiOx) nanoparticle modified glassy carbon (GC) electrode displays a well defined redox process with formal potential of ?0.03 V in pH 7.4. Cyclic voltammetry was used for deposition of (NiOx) nanoparticles and immobilization of SOD onto GC electrode. The surface coverage (Γ) and heterogeneous electron transfer rate constant (ks) of immobilized SOD are 1.75×10?11 mol cm?2 and 7.5±0.5 s?1, respectively. The biosensor shows a fast amperometric response (3 s) toward superoxide at a wide concentration range from 10 µM to 0.25 mM with sensitivity of 13.40 nA µM?1 cm?2 and 12.40 nA µM?1 cm?2, detection limit of 2.66 and 3.1 µM based on anodically and cathodically detection. This biosensor exhibits excellent stability, reproducibility and long life time.  相似文献   

9.
A nonenzymatic glucose sensor was successfully established by electrochemically decorating cobalt oxides (CoOx) on a nanoporous gold electrode (NPG) using cobalt hexacyanoferrate (CoHCF) as a precursor. It exhibited high sensitivity and long‐term stability as well as satisfactory quantification of glucose concentration in human serum samples. The morphology and surface analysis of the resulting CoOx/NPG were carefully characterized. Two detection methods, cyclic voltammetry and amperometry, were employed to evaluate the performance of CoOx/NPG towards glucose sensing in alkaline solution. Using cyclic voltammetry, at ?0.5 V, the glucose partial oxidation peak current is linear to the glucose concentration up to 14 mM with a sensitivity of 283.7 µA mM?1 cm?2. A linear amperometric response at 0.55 V was obtained in the glucose concentration range from 2 µM to 2 mM with a sensitivity of 2025 µA mM?1 cm?2 and a response time <3 s.  相似文献   

10.
Pt µdisc electrodes have been modified by mesoporous organosilica thin films by electrochemically assisted self‐assembly (EASA) of mercaptopropyltrimethoxysilane (MPTMS), tetraethoxysilane (TEOS), and the surfactant cetyltrimethylammonium bromide (CTAB). The EASA process involves the generation of hydroxide ions at the electrode/solution interface, upon the application of a cathodic current density, leading to TEOS and MPTMS polycondensation around the CTAB template and concomitant growing of a thiol‐functionalized mesoporous film onto the electrode surface. The experimental conditions (current density, deposition time, silane concentration and molar ratio between surfactant template and silane) were optimised to form a thin and permeable film likely to be used in preconcentration electroanalysis. The morphology of the film electrodes were characterised by scanning electron microscopy. The permeability properties of the modified Pt µdisc electrodes have been evidenced by cyclic voltammetry using Ru(NH3)63+ as a redox probe. The best parameters identified for the film preparation are a current density of ? 8 mA cm?2 applied for 15 s in a solution containing 110 mM of hydrolysed silane precursors and 70.4 mM of CTAB. Pt µdisc electrodes modified in these conditions were used for the open‐circuit preconcentration of Hg(II) species prior to their detection by anodic stripping voltammetry in a mercury‐free solution. In the optimized conditions, a sensitivity of 14.3 mA cm?2 µM?1 was obtained for the 0.02–0.08 µM concentration range. The analytical performance of such organosilica films could decay by up to two orders of magnitude for the materials prepared in conditions other than the optimized ones, highlighting the need for a fine control of the deposition parameters to elaborate sensors based on such modified ultramicroelectrodes.  相似文献   

11.
A new composite electrode based on multiwall carbon nanotubes (MWCNT) and silicone‐rubber (SR) was developed and applied to the determination of propranolol in pharmaceutical formulations. The effect of using MWCNT/graphite mixtures in different proportions was also investigated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for electrochemical characterization of different electrode compositions. Propranolol was determined using MWCNT/SR 70 % (m/m) electrodes with linear dynamic ranges up to 7.0 µmol L?1 by differential pulse and up to 5.4 µmol L?1 by square wave voltammetry, with LODs of 0.12 and 0.078 µmol L?1, respectively. Analysis of commercial samples agreed with that obtained by the official spectrophotometric method. The electrode is mechanically robust and presented reproducible results and a long useful life.  相似文献   

12.
The simultaneous determination of Zn and Cu by anodic stripping voltammetry (ASV) is prone to errors due to the formation of Cu‐Zn intermetallic compounds. The main aim of this work was to study the possibility of simultaneous determination of Zn and Cu, together with Hg and Pb, using a mercury‐free solid gold microwire electrode. The multi‐element detection was carried out by differential pulse anodic stripping voltammetry (DPASV), in a chloride medium (0.5 M NaCl) under moderate acid conditions (HCl 1.0 mM) in the presence of oxygen, where the gold microwire electrode was used as stationary or vibrating working electrode during the deposition step. Under these conditions, no formation of Cu‐Zn intermetallic compounds were found for concentrations usually determined in surface waters. In addition, quantification of Zn and Cu, together with Hg and Pb, can be performed in a wide range of concentrations (about two orders of magnitude) using the same sample, in a very short period of time. The detection limits for Cu, Hg, Pb and Zn, using a vibrating electrode and 30 s of deposition time, were 0.2 µg L?1 for Hg, 0.3 µg L?1 for Pb and 0.4 µg L?1 for Zn and Cu, respectively. The proposed DPASV methods were successfully applied to the determination of Cu, Hg, Pb, and Zn in a certified reference fresh water, river, tap and coastal sea waters. These results proved the applicability and versatility of the proposed methods for the analysis of different water matrices and showed that a gold microwire electrode is a suitable choice to determine simultaneously Zn and Cu.  相似文献   

13.
《Analytical letters》2012,45(3):507-520
Abstract

This work is aimed at the elucidation of the oxidation mechanism for the tricyclic antidepressant imipramine using electrochemical and quantum chemical studies. The excellent response obtained with the use of a rigid graphite‐polyurethane composite electrode (GPU) provided the development of a new electroanalytical methodology, in 0.10 mol/L BR buffer (pH 7.0), employing square wave voltammetry. Detection and quantification limits of 4.60×10?9 mol/L(1.5 µg L) and 3.04×10?7 mol/L (96 µg L) were obtained. This methodology was tested in a commercial formulation of Tofranil® and excellent recoveries were achieved by electrochemical (97.60±0.90%) and spectrophotometrical (87.10±0.90%) methods.  相似文献   

14.
Diphenylamine (DPA) monomers have been electropolymerized on the amino‐functionalized multiwalled carbon nanotube (AFCNT) composite film modified glassy carbon electrode (GCE) by cyclic voltammetry (CV). The surface morphology of PDPA‐AFCNT was studied using field‐emission scanning electron microscopy (FE‐SEM). The interfacial electron transfer phenomenon at the modified electrode was studied using electrochemical impedance spectroscopy (EIS). The PDPA‐AFCNT/GCE represented a multifunctional sensor and showed good electrocatalytic behavior towards the oxidation of catechol and the reduction of hydrogen peroxide. Rotating‐disk electrode technique was applied to detect catechol with a sensitivity of 1360 µA mM?1 cm?2 and a detection limit of 0.01 mM. Amperometric determination of hydrogen peroxide at the PDPA‐AFCNT film modified electrode results in a linear range from 10 to 800 µM, a sensitivity of 487.1 µA mM?1 cm?2 and detection limit of 1 µM. These results show that the nano‐composite film modified electrode can be utilized to develop a multifunctional sensor.  相似文献   

15.
Fluorine? tin oxide (FTO) nanostructure was developed on the surface of a glass plate using spray payroliziz method. A new electrochemical biosensor was fabricated based on a layer by layer process. In this process chitosan? Fe3O4 (CH? Fe3O4) nanocomposite film was prepared at the surface of FTO electrode by dip? coating method. In the next step, the glucose oxidase (GOx) was immobilized on the CH? Fe3O4/FTO nanocomposite electrode. The GOx/CH? Fe3O4/FTO bioelectrode has a linear range of 10–270 µM and a detection limit of 5 µM. The highest sensitivity was obtained at 1.2 µA mM?1 cm?2.  相似文献   

16.
A novel sensor based on carbon black‐gold nanoparticle nanocomposite modified screen‐printed electrode (CB‐AuNPs/SPE) for the detection of As(III) has been developed. The sensor was prepared modifying the SPE with CB and AuNPs by a drop casting automatable deposition. The As(III) was detected by CB‐AuNPs/SPE using anodic stripping voltammetry, with a high sensitivity (673±6 µA µM?1 cm?2) and reaching a LOD of 0.4 ppb. Finally, CB‐AuNPs/SPE has been applied to As(III) trace analysis in drinking water, obtaining satisfactory recovery values (99±9 %).  相似文献   

17.
Herein, we have demonstrated a preparation of palladium nanoparticles on electroactivated graphite nanosheets modified screen printed carbon electrode (PdNPs‐EGNS/SPCE) by a simple electrochemical method. The well‐prepared electrocatalyst was potentially applied to the high performance electrocatalytic oxidation of hydrazine in neutral medium. The PdNPs‐EGNS novel composite was characterized by scanning electron microscope (SEM) and the average diameter and thickness of PdNPs and EGNS were found to be ~38 nm and 85 nm, respectively. The high performance electrocatalytic determination of hydrazine was performed by the amperometric i‐t method. The fabricated sensor displayed irreversible electrocatalytic oxidation of hydrazine with diffusion‐controlled electrode process. The oxidation of hydrazine at PdNPs‐EGNS/SPCE showed wider linear range 0.05–1415 µM and high sensitivity 4.382 µA µM?1 cm?2. The as‐prepared electrocatalyst achieved quick response towards hydrazine with a lower detection limit 4 nM.  相似文献   

18.
The voltammetric behavior of two genotoxic nitro compounds (4‐nitrophenol and 5‐nitrobenzimidazole) has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam electrode (p‐AgSAE), a mercury meniscus modified silver solid amalgam electrode (m‐AgSAE), and a mercury film modified silver solid amalgam electrode (MF‐AgSAE). The optimum conditions have been evaluated for their determination in Britton‐Robinson buffer solutions. The limit of quantification (LQ) for 5‐nitrobenzimidazole at p‐AgSAE was 0.77 µmol L?1 (DCV) and 0.47 µmol L?1 (DPV), at m‐AgSAE it was 0.32 µmol L?1 (DCV) and 0.16 µmol L?1 (DPV), and at MF‐AgSAE it was 0.97 µmol L?1 (DCV) and 0.70 µmol L?1 (DPV). For 4‐nitrophenol at p‐AgSAE, LQ was 0.37 µmol L?1 (DCV) and 0.32 µmol L?1 (DPV), at m‐AgSAE it was 0.14 µmol L?1 (DCV) and 0.1 µmol L?1 (DPV), and at MF‐AgSAE, it was 0.87 µmol L?1 (DCV) and 0.37 µmol L?1 (DPV). Thorough comparative studies have shown that m‐AgSAE is the best sensor for voltammetric determination of the two model genotoxic compounds because it gives the lowest LQ, is easier to prepare, and its surface can be easily renewed both chemically (by new amalgamation) and/or electrochemically (by imposition of cleaning pulses). The practical applicability of the newly developed methods was verified on model samples of drinking water.  相似文献   

19.
A new chemically modified bismuth film electrode coated with an ionic liquid [(1‐ethyl‐3‐methylimidazolium tetracyanoborate (EMIM TCB)] and Nafion was developed for the simultaneous determination Pb2+ and Cd2+ by anodic stripping voltammetry. Compared with conventional bismuth film electrodes, this electrode exhibited greatly improved electrochemical activity for Pb2+ and Cd2+ detection due to the unique properties of Nafion polymer and ionic liquid. The key experimental parameters related to the fabrication of the electrode and the voltammetric measurements were optimized on the basis of the stripping signals, where the peak currents increased linearly with the metal concentrations in a range of 10–120 µg L?1 with a detect limit of 0.2 µg L?1 for Pb2+, and 0.5 µg L?1 for Cd2+ for 120s deposition. High reproducibility was indicated from the relative standard deviations (1.9 and 2.5 %) for nine repetitive measurements of 20 µg L?1 Pb2+ and Cd2+, respectively. In addition, the surface characteristics of the modified BiFE were investigated by scanning electron microscopy (SEM), and results showed that fibril‐like bismuth nanostructures were formed on the porous Nafion polymer matrix. Finally, the developed electrode was applied to determine Pb2+ and Cd2+ in water samples, indicating that this electrode was sensitive, reliable and effective for the simultaneous determination of Pb2+ and Cd2+.  相似文献   

20.
The determination of KRAS was performed using electrochemical sensing devices based on graphite and graphene pastes, modified with a phthalocyanine-boron dipyrromethene (BODIPY) and azulenes dyes. The limits of quantification for KRAS were 1.54?×?10?4?µg/mL using the sensor based on the phthalocyanine-BODIPY dye and graphite, 2.64?×?10?7?µg/mL using the sensor based on 2,6-bis((E)-2-(furan-2-yl)vinyl)-4-(4,6,8-trimethylazulen-1-yl)pyridine/TiO2Pt/reduced graphene oxide, and 3.84?×?10?3?µg/mL using the sensor based on 2,6-bis((E)-2-(thiophen-3-yl)vinyl)-4-(4,6,8-trimethylazulen-1-yl)pyridine/TiO2Pt/reduced graphene oxide. Recovery measurements demonstrated the suitable analytical performance of these sensors for the early detection of colon cancer by the analysis of whole blood samples.  相似文献   