首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electroanalysis》2006,18(7):655-661
In this paper, the possibility of analyzing levodopa and carbidopa by differential pulse voltammetry (DPV) utilizing a glassy carbon electrode in 0.1 mol L?1 HClO4 is reported. Cyclic voltammograms of levodopa show a redox couple with anodic and cathodic peak potentials at 0.58 V and 0.52 V (vs. Ag/AgCl), respectively. For carbidopa, there are two oxidation waves with maximum currents at 0.53 V and 1.02 V, without any cathodic counterpart at slow enough scan rate. Since in such conditions, the oxidation product of carbidopa does not undergo reduction, it is possible to analyze levodopa without interference. On the other hand, carbidopa can be determined between 0.85 V and 1.1 V in the presence of levodopa, coating the electrode with a Nafion film, which is selective for carbidopa. The developed methodology was applied to two different commercial samples of pharmaceutical products. The obtained data were compared with the results of the analysis by high performance liquid chromatography (HPLC) with UV detection, showing good correlation (relative errors changing between 0.4% and 3.5%) and absence of interference of the other components that accompanied the pharmaceuticals.  相似文献   

2.
An electrochemical sensor for simultaneous quantification of Levodopa (L‐dopa) and Carbidopa (C‐dopa) using a β‐cyclodextrin/poly(N‐acetylaniline) (β‐CD/PNAANI) modified carbon paste electrode has been developed. Preconcentrating effect of β‐CD as well as its different inclusion complex stability with L‐dopa and C‐dopa was used to construct an electrochemical sensor for quantification of these important analytes. The overlapping anodic peaks of L‐dopa and C‐dopa at 810 mV on bare carbon paste electrode resolved in two well‐defined voltammetric peaks at 450 and 880 mV vs. Ag/AgCl, respectively, with a drastic enhancement of the anodic peak currents. Under optimized conditions, linear calibration curves were obtained in the ranges of 0.5–117 µM and 1.6–210 µM with detection limits down to 0.2 and 0.8 µM for L‐dopa and C‐dopa, respectively. The proposed electrode was successfully applied for the determination of L‐dopa /C‐dopa in pharmaceutical formulations and the results were in close agreement with the labeled values.  相似文献   

3.
Diltiazem (DTZ) hydrochloride, a calcium channel blocker compound, is a very well-known drug used by many clinicians to treat important diseases playing a role in increased morbidity and mortality among adults worldwide, namely hypertension, cardiac arrhythmia, and ischemic heart disease (angina pectoris). These diseases are a common public health concern, implying that the construction of a specific, accurate, and simple sensor for DTZ determination is needed. Herein, an innovative, portable, and sensitive modified carbon paste electrode (MCPE) was seamlessly developed based on the affordable green compound N-bromosuccinimide (NBS) as a sensing material and tricresyl phosphate as a solvent mediator for the voltammetric determination of DTZ. The proposed NBS-MCPE exhibited an excellent electrocatalytic activity towards the oxidation of DTZ molecules in a phosphate buffer solution of pH 5.0 in presence of 20 μM sodium dodecyl sulfate to improve the developed sensor performance. The sensor was found to respond linearly to the DTZ drug over a wide concentration ranging from 1 μM to 300 μM with a low limit of detection. LSV and EIS measurements were also used to scrutinize our sensor, in addition to using scanning electron microscopy and energy dispersive X-ray analysis techniques for its surface morphology inspection before and after soaking in the drug-containing solution. The applicability of the proposed sensor for the rapid, sensitive, and selective determination of DTZ in pharmaceutical preparation and human urine samples was assessed and the obtained results were compared with that of the reported HPLC analytical method.  相似文献   

4.
The electrochemical oxidation of levodopa on the surface of a carbon paste electrode modified with graphene nanosheets, 1‐(4‐bromobenzyl)‐4‐ferrocenyl‐1H‐[1,2,3]‐triazole (1,4‐BBFT) and hydrophilic ionic liquid (n‐hexyl‐3‐methylimidazolium hexafluoro phosphate) as a binder is studied. It has been found that the oxidation of levodopa at the surface of a modified electrode occurs at a potential of about 210 mV less positive than that of an unmodified carbon paste electrode (CPE). The prepared modified electrode exhibits a very good resolution of the voltammetric peaks of levodopa and cabergoline. The electrode has been applied successfully for the determination of levodopa and cabergoline in some real samples.  相似文献   

5.
《Analytical letters》2012,45(13):2701-2718
ABSTRACT

A method based on a partial least-squares calibration (PLS) for the simultaneous spectrophotometric determination of levodopa (I) and benserazide (II) in a commercially available pharmaceutical preparation is proposed. The calibration procedure was developped by using laboratory made mixtures of I and II, and optimized by selecting the most suitable wavelength range and spectral mode. The relative standard error of prediction (RSEP %) was 0.5% and 0.9% with a limiting reproducibility (R) of 4 10?6 M and 1.5 10?6 M for levodopa and benserazide, respectively The proposed method is straightforward, expeditious and precise. Its results are consistent with those provided by HPLC for the two analytes.  相似文献   

6.
This work describes the development of a biosensor for paracetamol (PAR) determination based on a glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT) and laccase enzyme (LAC), which was immobilized by means of covalent crosslinking using glutaraldehyde. Voltammetric investigations were carried out by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV). The biosensor was characterized by Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FT‐IR). The results showed that the use of MWCNT/LAC composite increased the sensor sensitivity, compared to bare glassy carbon electrode. Factors affecting the voltammetric signals such as pH, ionic strength, scan rate and interferents were assessed. Linear range, limit of detection (LOD) and limit of quantitation (LOQ) obtained were 10–320 μmol L?1, 7 μmol L?1 and 10 μmol L? 1, respectively. The developed biosensor was successfully applied to PAR determination in urine and pharmaceutical formulations samples, with recovery varying from 99.96 to 106.20 % in urine samples and a relative standard deviation less than 1.04 % for PAR determination in pharmaceutical formulations. Therefore, the MWCNT‐LAC/GCE exhibits excellent sensitivity and can be used to PAR determination as a viable alternative in clinical analyzes and quality control of pharmaceutical formulations, through a simple, fast and inexpensive methodology.  相似文献   

7.
《Electroanalysis》2017,29(2):423-432
In the present paper, a stable and selective non‐enzymatic sensor is reported for determination of glucose (Glc) by using a carbon paste electrode modified with multiwall carbon nanotubes and Ni(II)‐SHP complex as modifier in an alkaline solution. This modified electrode showed impressive activity for oxidation of glucose in NaOH solution. Herein, Ni(II)‐SHP acts as a suitable platform for oxidation of glucose to glucolactone on the surface of the modified electrode by decreasing the overpotential and increasing in the current of analyte. Under the optimum conditions, the rate constant and electron transfer coefficient between electrode and modifier, were calculated to be 1.04 s−1 and 0.64, respectively. The anodic peak currents indicated a linear dependency with the square root of scan rate and this behavior is the characteristic of a diffusion controlled process. So, the diffusion coefficient of glucose was found to be 3.12×10−6 cm2 s−1 due to the used number of transferred electron of 1. The obtained results revealed two linear ranges (5 to 190.0 μM (R2=0.997), 210.0 to 700.0 μM (R2=0.999)) and the detection limit of 1.3 μM for glucose was calculated by using differential pulse voltammetry (DPV) method. Also, the designed sensor was used for determination of glucose in the blood serum and urine samples. Some other advantages of Ni(II)‐SHP/CNT/CPE sensor are remarkable reproducibility, stability and selectivity which can be related to using nanomaterial of carbon nanotubes due to enhancement of electrode surface area.  相似文献   

8.
《Analytical letters》2012,45(12):2267-2286
Abstract

A simple and highly sensitive method is described for voltammetric determination of leucine in blood and urine samples; namely, a glassy carbon electrode with an effective method is modified with multiwall carbon nanotubes (MWNTs). The cyclic voltammetric results indicated that MWNTs remarkably enhanced electrocatalytic activity toward the oxidation of leucine. Under the optimum condition the calibration curve was linear in the concentration range 9.0 × 10?6 ? 1.5 × 10?3 mol L?1, with the detection limit of 3.0 × 10?6 mol L?1 and a relative standard deviation (RSD%) lower than 3.0% (n = 5). Also, some kinetic parameters were determined and a multistep mechanism for oxidation of leucine was proposed.  相似文献   

9.
In the present work, the electrochemical behavior of an antimigraine drug, almotriptan malate (ALM), on a multiwalled carbon nanotube (MWCNT) film modified glassy carbon electrode under cyclic voltammetry was described for the first time. A significant enhancement in the oxidation peak current of ALM was noticed at MWCNT‐GCE. This property was exploited to develop a simple, sensitive and time‐saving differential pulse voltammetric method for the determination of ALM in bulk and pharmaceutical samples. A linear relationship was observed between concentration and peak current with a correlation coefficient of 0.9915 in the range of 0.25–37.5 µM ALM.  相似文献   

10.
In the present work, the cathodic stripping voltammetric methodology using a hanging mercury drop electrode was described for simultaneous determination of lead and zinc in different real samples. The method is based on adsorption of metal ions on mercury electrode using carbidopa as a suitable complexing agent. The potential was scanned to the negative direction and the differential pulse stripping voltammograms were recorded. Optimal conditions were found to be: accumulation time; 70 s, accumulation potential; 50 mV versus Ag/AgCl, scan rate; 40 mV s?1, supporting electrolyte; 0.01 M ammonia buffer at pH 8.5, and concentration of carbidopa; 8.0 μM. The relationship between the peak current versus concentration was linear over the range of 0.1–210 and 0.2–170 nM for lead and zinc, respectively. The detection limits are 0.09 and 0.15 nM for lead and zinc ions respectively. The relative standard deviations at a concentration level of 70 nM of both metal ions are found 1.08 and 1.24% for lead and zinc ions respectively.  相似文献   

11.
Amr Lotfy Saber 《Electroanalysis》2013,25(12):2707-2714
The present article reports for the first time the use of Aliquat 336S‐atorvastatin as an electroactive material in a poly(vinyl chloride) matrix membrane sensor plasticized with ortho‐nitrophenyl‐octylether (o‐NPOE) or dioctylphthalate (DOP) for determination of atorvastatin in biological samples (human plasma) and in pharmaceutical preparations. The sensor shows fast, stable and reproducible response over the concentration range of 1.0×10?7–1.0×10?2 mol L?1 atorvastatin with anionic slopes of 60.94±0.2 and 58.22±0.2 and pH range of 5.0–9.0 for o‐NPOE and DOP plasticized based membrane sensors, respectively. The response time of the sensor is stable and fast (10 s). Results were achieved with average recoveries of 99.5 % and 99.3 % and mean standard deviations of ±1.1 % and ±1.4 % for o‐NPOE and DOP plasticized based membrane sensors, respectively. The sensor exhibits high selectivity towards atorvastatin in the presence of many anions, drug excipients and diluents. Validation of the method according to the quality assurance standards shows suitability of the proposed sensors for use in the quality control assessment of the drug.  相似文献   

12.
Amr L. Saber 《Electroanalysis》2010,22(24):2997-3002
Simple, selective and accurate sensors were developed for the determination of melatonin and oxomemazine in biological samples (urine) and in pharmaceutical preparations. Potentiometric measurements were based on bismus tetraiodate‐drug ion‐pair as novel electroactive materials incorporating a plasticized PVC membrane with o‐nitrophenyl octyl ether or dioctyl phthalate. Each sensor was conditioned for at least two days in 0.1 M drug solution before use. It exhibited fast and stable Nernstian response for melatonin and oxomemazine over the concentration range of 1.0×10?6–1.0×10?2 M and 1.0×10?5–1.0×10?2 M, pH range of 3.0–6.5 and 3.5–6.0 for melatonin and oxomemazine sensors, respectively. Results with an average recovery not more than 101 % and a mean standard deviation less than 1.0 % of the nominal were obtained for the four sensors. The sensors showed reasonable selectivity towards investigated drugs in presence of many cations.  相似文献   

13.
A multicomponent electrochemical sensor, with two nanometer-scale components in sensing matrix/electrode, was used to simultaneous determination of levodopa (LD) and tyramine (TR) in pharmaceutical and diet samples. Multiwall carbon nanotubes (MWCNTs) were used as carbonaceous materials in the electrode construction. 5-amino-3',4'-dimethoxy-biphenyl-2-ol (5ADMB) was used as electron mediator and Pt nanoparticles (nPt) as a catalyst. The 5ADMB catalyzes the oxidation of LD to the corresponding catecholamine, which is electrochemically reduced back to LD. Preparation of this electrode was very simple and modified electrode showed good properties at electrocatalytic oxidization of LD and TR. Using differential pulse voltammetry (DPV), a highly selective and simultaneous determination of LD and TR has been explored at the modified electrode. Differential pulse voltammetry peak currents of LD and TR increased linearly with their concentrations at the ranges of 0.50–100.0 μM and 0.60–100.0 μM, respectively. Also, the detection limits for LD and TR were 0.31 and 0.52 μM, respectively. The electrode exhibited an efficient catalytic response with good reproducibility and stability.  相似文献   

14.
The present work discuses new findings in the electrochemistry of naproxen over graphite electrodes. This new approach, allows the proposal of a simple and competitive low‐cost method to carry out naproxen’s voltammetric quantification. Naproxen’s indirect quantification through an adsorption anodic wave was performed at a graphite bar electrode using differential pulse voltammetry. An anodic current maximum was recorded at a potential of ?0.3 V referred to a saturated Ag/AgCl reference electrode. The calibration plot having a correlation coefficient of 0.990, sensibility of 4.19±0.62 µA cm3 µg?1, with detection and quantification limits of 0.68 and 3.3 µg cm?3, respectively.  相似文献   

15.
A new linear sweep voltammetric method for quantitative lamotrigine (LMT) determination based on an electrochemically pre-treated pencil graphite electrode (PGE*) is presented. Response characteristics of the PGE* toward the mentioned compound were investigated by cyclic voltammetry and linear sweep voltammetry. The quantitative determination of LMT revealed a wide linear range of 2.5 ⋅ 10−5–1.0 ⋅ 10−3 M with a detection limit of 1.94 ⋅ 10−5 M. The method was used successfully for LMT determination in a pharmaceutical formulation.  相似文献   

16.
A carbon‐paste electrode modified with 2,7‐bis(ferrocenyl ethyl)fluoren‐9‐one and carbon nanotubes was used for the sensitive voltammetric determination of levodopa (LD). The electrochemical response characteristics of the modified electrode toward LD, uric acid (UA) and folic acid (FA) were investigated. The results showed an efficient catalytic activity of the electrode for the electrooxidation of LD, which leads to lowering its overpotential by more than 320 mV. The modified electrode exhibits an efficient electron mediating behavior together with well‐separated oxidation peaks for LD, UA and FA. Also, the modified electrode was used for determination of LD in some real samples.  相似文献   

17.
This study introduces modified carbon paste electrodes with carbon nitride nanosheets (CNNS) and outlines their application for the determination of hydroxychloroquine sulfate (HCQ) in tablets and synthetic urine samples. CNNS were synthesized by hydrothermal route (200 °C, 10 h) using melamine and citric acid as their precursors. The carbon nitride nanosheets-based electrode (CNNS/E) presented a linear dynamic range for HCQ (LDR), ranging from 10.0 nmol l−1 to 6.92 μmol l−1, and detection (LOD) and quantification limits (LOQ) of 0.16 nmol l−1 and 0.52 nmol l−1, respectively. LOD and LOQ were calculated by the equations: LOD=3(Sd/b), and LOQ=10(Sd/b). The modified sensor presented excellent relative standard deviations for parameters such as repeatability (2.39 % and 1.87 %) and reproducibility (3.22 % and 2.32 %) in HCQ oxidation peaks (1 and 2). The CNNS/E has not shown significant variations in its anodic signal intensity in the presence of some organic and inorganic substances. It is worth bearing in mind that CNNS/E can be easily manufactured and the sensor has the lowest HCQ detection limits reported so far. The proposed sensor was successfully applied for HCQ determination in tablets and synthetic urine, showing good recovery values and an error of 0.60 % about comparative method in tablet samples, assuring the quality of the method.  相似文献   

18.
Development of nanocomposite based electrochemical sensors for detection of toxic chemicals describes an environmentally benign strategy for monitoring the health of ecosystem. Herein, we reported in situ preparation of graphitic carbon nitride (g-C3N4) decorated Ag2S/NiFe2O4 nanocomposite sensor by facile precipitation method. The electrochemical studies demonstrated efficient electrocatalytic activity of ternary nanocomposite pasted glassy carbon electrode (g-C3N4@Ag2S/NiFe2O4/GCE) for selective detection of formaldehyde. Moreover, fabricated sensor exhibit rapid amperometric response with excellent selectivity, remarkable sensitivity (1681 μA mmol L−1 cm−2) and lower detection limit (LOD: 1.63 μmol L−1). It is noteworthy to mention that sensor exhibits good operational and long-term storage stability.  相似文献   

19.
A potentiometric carbon paste sensor was fabricated for determination of clarithromycin based on incorporation of the ion association complex of the clarithromycin‐phosphotungstate. The proposed sensor exhibited a Nernstian slope of 59.2±0.3 mV per decade for clarithromycin over a wide concentration range of 7.4×10?7 to 1.5×10?3 M, with a low detection limit of 5.0×10?7 M. The proposed sensor manifested advantages of very fast response, long life time and, most importantly, excellent selectivity for clarithromycin relative to a wide variety of common foreign inorganic cation, and also biological species. The sensor was successfully applied to determine clarithromycin in clarithromycin tablet, blood serum and urine samples. The inclusion complex formation between β‐cyclodextrin and clarithromycin was studied by the proposed sensor. The influence of the temperature on the response of the sensor was investigated and the temperature coefficient of the sensor was calculated.  相似文献   

20.
以单壁碳纳米管作为电极材料,基于减压过滤和电聚合方法制备了一种薄膜型一氧化氮(NO)电化学传感器。扫描电镜、红外光谱和电化学交流阻抗表征表明,减压过滤可以制备出导电性好、电分析性能优良的薄膜电极,而罗丹明B能通过电聚合在其表面形成高比表面的纳米敏感结构。这种薄膜型电化学传感器对NO具有灵敏的电化学响应,其安培氧化电流与NO浓度在7.2×10-8~2.5×10-5mol/L范围内呈良好的线性关系,检出限(S/N=3)达3.6×10-8mol/L。将该传感器紧贴在麻醉豚鼠的肝脏表面,成功实现了肝组织细胞在L-精氨酸刺激下NO释放的实时监测。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号