首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Anodic stripping voltammetry (ASV) determination of Pb2+, Cd2+, and Zn2+ was done using metal catalyst free carbon nanotube (MCFCN) electrodes. Osteryoung square wave stripping voltammetry (OSWSV) was selected for detection. The MCFCNTs are synthesized via Carbo Thermal Carbide Conversion method which leads to residual transition metal free in the CNT structure. The new material shows very good results in detecting heavy metal ions, such as Pb2+, Cd2+, and Zn2+. The calculated limits of detection were 13 nM, 32 nM and 50 nM for Pb2+, Cd2+ and Zn2+, respectively with a deposition time of 150 s.  相似文献   

2.
Nanostructured magnesium silicate hollow spheres, one kind of non-conductive nanomaterials, were used in heavy metal ions (HMIs) detection with enhanced performance for the first time. The detailed study of the enhancing electrochemical response in stripping voltammetry for simultaneous detection of ultratrace Cd2+, Pb2+, Cu2+ and Hg2+ was described. Electrochemical properties of modified electrodes were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The operational parameters which have influence on the deposition and stripping of metal ions, such as supporting electrolytes, pH value, and deposition time were carefully studied. The anodic stripping voltammetric performance toward HMIs was evaluated using square wave anodic stripping voltammetry (SWASV) analysis. The detection limits achieved (0.186 nM, 0.247 nM, 0.169 nM and 0.375 nM for Cd2+, Pb2+, Cu2+ and Hg2+) are much lower than the guideline values in drinking water given by the World Health Organization (WHO). In addition, the interference and stability of the modified electrode were also investigated under the optimized conditions. An interesting phenomenon of mutual interference between different metal ions was observed. Most importantly, the sensitivity of Pb2+ increased in the presence of certain concentrations of other metal ions, such as Cd2+, Cu2+ and Hg2+ both individually and simultaneously. The proposed electrochemical sensing method is thus expected to open new opportunities to broaden the use of SWASV in analysis for detecting HMIs in the environment.  相似文献   

3.
Hydrogen evolution bothers stripping analysis significantly. Dioctyl phthalate-based carbon paste electrode exhibits extremely wide cathodic potential window. It is explored as a powerful substrate electrode to solve the problem of hydrogen evolution and further improve reproducibility for stripping analysis using bismuth-coated electrodes for the first time. It was successfully applied to the simultaneous determination of Zn2+, Cd2+, and Pb2+. Linear responses are obtained for Zn2+ in the range of 10–100 μg L−1 and for Pb2+ and Cd2+ in the range of 5–100 μg L−1. The detection limits for Zn2+, Cd2+, and Pb2+ are 0.1 μg L−1, 0.22 μg L−1 and 0.44 μg L−1, respectively. The method has been successfully applied to the determination of Zn2+, Cd2+, and Pb2+ in waste water samples. The detection strategy based on the combination of dioctyl phthalate-based carbon paste electrode and bismuth-coated electrodes holds great promise for stripping analysis.  相似文献   

4.
A sensitive voltammetric method for detection of trace heavy metal ions using chemically modified carbon nanotubes (CNTs) electrode surfaces is described. The CNTs were covalently modified with cysteine prior to casting on electrode surfaces. Cysteine is an amino acid with high affinities towards some heavy metals. In this assay, heavy metals ions accumulated on the cysteine‐modified CNT electrode surfaces prior to being subjected to differential pulse anodic stripping voltammetry analysis. The resulting peak currents were linearly related to the concentrations of the metal ions. The method was optimized with respect to accumulation time, reduction time and reduction potential. The detection limits were found to be 1 ppb and 15 ppb for Pb2+ and Cu2+ respectively. The technique was used for the detection of Pb2+ and Cu2+ in spiked lake water. The average recoveries of Pb2+ and Cu2+ were 96.2% and 94.5% with relative standard deviations of 8.43% and 7.53% respectively. The potential for simultaneous detection of heavy metal ions by the modified CNTs was also demonstrated.  相似文献   

5.
Disulfide based receptor was prepared using single step condensation reaction and suspended into organic nanoparticles to extend its practical application in aqueous samples. The prepared nanoparticles were used for the simultaneous recognition of three different metallic species (Cu2+, Cd2+, and Pb2+) in aqueous media through voltammetric studies. These metals can be determined simultaneously and without interferences from any of the other potential interferent metal ions, as different signals are displayed in cyclic as well as differential pulse voltammograms, with a detection limit of 193.0 nM for Cu2+, 52.0 nM for Cd2+ and 32.0 nM for Pb2+. The study was extended to real sample analysis by preparing the artificial mixtures of said metal ions.  相似文献   

6.
《Analytical letters》2012,45(10):1746-1757
Bifunctional combination of carbon nanotubes and ionophore is introduced for anodic stripping analysis of lead (Pb2+). Carbon nanotubes are employed to improve the detection sensitivity due to their excellent electrical conductivity and strong adsorption ability. An ionophore is utilized for its excellent selectivity toward Pb2+. The proposed carbon nanotubes/ionophore modified electrode shows improved sensitivity and selectivity for Pb2+. Low detection limit (1 nM), wide linear range (5 nM–8 µM) and excellent selectivity over other metal ions (Cd2+, Cu2+, and Hg2+) was obtained. The practical application has been carried out for determination of Pb2+ in real water samples.  相似文献   

7.
Mesoporous SBA-16 was synthesized using tetraethoxysilane as silicon source and a ternary system consisting of surfactant F127, water and butanol. Owing to the excellent properties of SBA-16 such as lager surface area and strong accumulation ability, the stripping peak current of Cd2+ and Pb2+ remarkably increases at the SBA-16 modified carbon paste electrode. Moreover, the peak current of Cd2+ and Pb2+ further enhances after the addition of I?. Under the joint enhancement effects of SBA-16 and I?, the detection sensitivity of Cd2+ and Pb2+ is greatly improved. The influences of concentration of I?, amount of SBA-16, accumulation potential and time were investigated. As a result, a new electrochemical method with high sensitivity was developed for the simultaneous determination of Cd2+ and Pb2+. The limit of detection is 0.6 nM for Cd2+ and 1 nM for Pb2+. It was used to determine Cd2+ and Pb2+ in waste water sample, and the results consisted with the values that obtained by atomic absorption spectrometry.  相似文献   

8.
The efficiencies and performances of silver nanoparticle loaded activated carbon modified with 2-(4-isopropylbenzylideneamino)thiophenol (IPBATP-Ag-NP-AC) and activated carbon modified with IPBATP (IPBATP-AC), as new sorbents, were evaluated for separation and preconcentration of Cu2+, Zn2+, Co2+, Cd2+ and Pb2+ ions from real environmental samples. The retained metals content was reversibly eluted using 5?mL of CH3COOH (6.0?mol?L?1) and/or 10?mL of 4.0?mol?L?1 HNO3 for IPBATP-Ag-NP-AC and IPBATP-AC, respectively. The experimental parameters influence the recoveries of metal ions including pH, amounts of ligand and supports, condition of eluents, sample and eluent flow rates of has been investigated. The preconcentration factors were found to be 100 for Zn2+, Cd2+, Co2+, Cu2+ and 50 for Pb2+ ions using IPBATP-Ag-NP-AC, and 50 for Zn2+, Cd2+, Co2+, Cu2+ and 25 for Pb2+ ions using IPBATP-AC. The detection limit of both SPE-based sorbents was between 1.6–2.5?ng?mL?1 for IPBATP-AC and 1.3–2.5?ng?mL?1 for IPBATP-Ag-NP-AC. The proposed methods have been successfully applied for the extraction and determination of the understudy metal ions content in some real samples with extraction efficiencies higher than 90% and relative standard deviations (RSD) lower than 2.4%.  相似文献   

9.
A simple, low cost and sensitive voltammetric sensor was developed for the simultaneous detection of Pb2+, Cd2+, and Zn2+ based on a disposable carbon fiber rod (CFR). The important factors to enhance the sensing property were creation of a clean surface by dealing with CFR at a high potential and electrochemical deposition of Bi film to improve the accumulation of heavy metal ions.  相似文献   

10.
Mercury microelectrodes were prepared by ex situ deposition of Hg onto Pt microdiscs. By exploiting the known properties of microelectrodes in stripping analysis, an absolute method based on a simple equation derived from the stripping charge and the microelectrode steady-state current was assessed for the simultaneous quantification of Cd2+, Pb2+ and Cu2+ concentrations. The method was tested with synthetic solutions containing known amounts of Cd2+, Pb2+ and Cu2+. Then, it was used to determine the labile and total fractions of these metal ions in rain samples. The labile fractions were measured from samples at their natural pH while the total concentrations were determined from samples at pH=2.  相似文献   

11.
A 2,2′‐azinobis (3‐ethylbenzothiazoline‐6‐sulfonate) diammonium salt (ABTS)‐multiwalled carbon nanotubes (MWCNTs) nanocomposite/Bi film modified glassy carbon (GC) electrode was constructed for the differential pulse stripping voltammetric determination of trace Pb2+ and Cd2+. This electrode was more sensitive than ABTS‐free Bi/GC and Bi/MWCNTs/GC electrodes. Linear responses were obtained in the range from 0.5 to 35 μg L?1 for Cd2+ and 0.2 to 50 μg L?1 Pb(II), with detection limits of 0.2 μg L?1 for Cd2+ and 0.1 μg L?1 for Pb2+, respectively. This sensor was applied to the simultaneous detection of Cd2+ and Pb2+ in water samples with satisfactory recovery.  相似文献   

12.
The sonochemically facilitated, mercury free detection of Pb2+ at a copper electrode has been investigated as a means of simplifying the quantification of this important analyte and to minimise the interference of copper ion. The procedure relies upon maximising the formation of Pb-Cu intermetallic compounds leading to the emergence of a single, easily quantifiable stripping signal. Linear responses to Pb2+ were obtained with a sensitivity comparable to that obtained at a bare glassy carbon electrode. Interference from Cu2+, Zn2+ and Cd2+ was assessed on the copper electrode with no appreciable change in the Pb2+ voltammetric profile observed. In contrast, bare glassy carbon showed a significant change in Pb2+ voltammetric profile as Cu2+ was added, due to the formation of intermetallic species.  相似文献   

13.
Carbon nanotubes (CNTs) have attracted intense interest due to their excellent properties, such as increased electrode surface area, fast electron transfer rate, significant mechanical strength and good chemical stability. CNT threads, spun from shorter CNTs, inherit the advantages of CNTs, while avoiding the potential toxicity caused by individual CNTs. In this work, microelectrodes based on CNT threads were used to detect trace zinc by anodic stripping voltammetry with an estimated detection limit of 1.4 nM without mercury or bismuth films. CNT threads showed promise for measuring trace metals in small sample volumes without stirring such as encountered in some in vivo and in vitro applications.  相似文献   

14.
A novel chemically modified electrode for stripping determination of cadmium is presented in this paper, based on carbon nanotube‐hydroxyapatite (CNT‐HAP) nanocomposite, which can be prepared by an easy and effective one‐step sonication. The newly synthesized nanocomposite was characterized with FTIR, TEM, and electrochemical methods. Due to the combination of the strong absorption ability of HAP and excellent electroanalytical properties of CNTs, the GC/CNT‐HAP electrode has been successfully used for determination of Cd2+ by anodic stripping voltammetry with a linear range of 20 nM–3 μM. The sensitivity and detection limit are 25.6 μA/μM and 4 nM, respectively. The practical application of the proposed electrode has been carried out for the determination of trace levels of Cd2+ in real water samples.  相似文献   

15.
A new sensor has been developed for the simultaneous detection of cadmium, lead, copper and mercury, using differential pulse and square wave anodic stripping voltammetry (DPASV and SWASV) at a graphite–polyurethane composite electrode with SBA‐15 silica organofunctionalized with 2‐benzothiazolethiol as bulk modifier. The heavy metal ions were preconcentrated on the surface of the modified electrode at ?1.1 V vs. SCE where they complex with 2‐benzothiazolethiol and are reduced to the metals, and are then reoxidized. Optimum SWASV conditions lead to nanomolar detection limits and simultaneous determination of Cd2+, Pb2+, Cu2+ and Hg2+ in natural waters was achieved.  相似文献   

16.
We report herein a pseudo-crown based fluorescent receptor (1) for the selective detection of Cu2+ cation. Receptor 1 can detect Cu2+ even in 5 μM level in acetonitrile-water (9:1 v/v). Compound 1 is very effective for the detection of Cu2+ amongst the series of metal ions studied (Li+, Na+, K+, Ca2+, Mg2+, Ba2+, Pb2+, Fe3+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Hg2+ and Mn2+).  相似文献   

17.
High performance reduced graphene oxide (RGO)‐Nafion (N) thin film electrodes coated on silicon (Si) substrates (RGO‐N/Si) were successfully developed through thermal reduction of GO‐N without delamination from the substrates. The restoration of the RGO‐N nanostructure upon the addition of Nafion was proven by Raman spectroscopy (RS) and field emission scanning electron microscopy, and the restoration mechanism of the RGO‐N nanostructure was proposed. Through the investigation using x‐ray photoelectron spectroscopy (XPS), the polyfluorocarbon from Nafion possessed a function that could prevent the delamination of the RGO sheets from the substrates during the thermal reduction. The RGO‐N/Si samples were later used for the determination of trace heavy metals, such as divalent lead, cadmium and copper ions (Pb2+, Cd2+ and Cu2+, respectively) using square wave anodic stripping voltammetry in a 0.1 M acetate buffer solution (pH 5). Based on the electroanalytical measurements, the RGO‐N/Si samples exhibited a highly linear behavior in the detection of Cd2+, Pb2+ and Cu2+ over the concentration range of 50 nM to 300 nM with detection limits at nM levels. In addition, the RGO‐N/Si samples presented good recoveries of target metals in tap water samples.  相似文献   

18.
ZnO nanoparticles (ZnO-NP) were prepared by a facile precipitation technique using di-isopropyl amine as precipitating agent. The morpho-structure and porosity of the as-prepared nano-powder were investigated by FT-IR analysis, X-ray diffraction (XRD), scanning electron microscopy (SEM), and BET analysis. By drop-casting, a composite film was deposited to obtain ZnO-NP-Nafion/GCE modified electrode. The modified electrode was investigated by cyclic voltammetry, electrochemical impedance spectroscopy, and square wave anodic stripping voltammetry (SWASV) for the detection of Pb2+, Cd2+, Cu2+, and Fe3+, and it was successfully applied for the detection of Pb2+ and Cu2+ in real water samples.  相似文献   

19.
《Electroanalysis》2017,29(8):1903-1910
This paper describes the electrochemical behaviors of Cd2+ and Pb2+ on the proposed mesoporous carbon microspheres/mefenamic acid/nafion modified glassy carbon electrode (MC/MA/Nafion/GC) studied by square wave anodic stripping voltammetry (SWASV). The prepared material is characterized by XRD, SEM, FTIR, RAMAN and BET analysis. Experimental parameters, such as the deposition potential and time, the pH value of buffer solution were optimized. Under the optimized conditions, the electrode responded linearly to Cd2+ and Pb2+ in the concentration range from 50 to 300 nM, and the detection limits were 24.2 and 11.26 nM respectively. The sensitivity determined was 0.0623 μA/nM (Cd2+) and 0.192 μA/nM (Pb2+). Multiple metal ion detection with clear demarcation of peaks was produced by the electrode. Moreover, the modified electrode has possessed good selectivity and reproducibility of Cd2+ and Pb2+ detection. We also investigated the interference of various anions and surfactants for the detection of Cd2+ and Pb2+ ions. Finally the modified electrode was used to detect the presence of metal ions in practical samples and the results obtained are comparatively good with respect to AAS.  相似文献   

20.
A microcell for batch injection stripping voltammetry of trace metals with the use of a rotating disk working electrode has been developed and tested for samples of 0.2–0.3 mL. The detection limits for Pb2+, Cd2+ and Zn2+ are 0.03 ppb and 0.3 for a deposition time of 5.0 and 0.5 min, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号