首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
A new avenue for making porous frameworks has been developed by borrowing an idea from molecularly imprinted polymers (MIPs). In lieu of the small molecules commonly used as templates in MIPs, soft metal components, such as CuI, are used to orient the molecular linker and to leverage the formation of the network. Specifically, a linear dicarboxylate linker with thioether side groups reacted simultaneously with Ln3+ ions and CuI, leading to a bimetallic net featuring strong, chemically hard Eu3+–carboxylate links, as well as soft, thioether‐bound Cu2I2 clusters. The CuI block imparts water stability to the host; with the tunable luminescence from the lanthanide ions, this creates the first white‐emitting MOF that is stable in boiling water. The Cu2I2 block also readily reacts with H2S, and enables sensitive colorimetric detection while the host net remains intact.  相似文献   

2.
A highly selective molecularly imprinted polymer electrochemical sensor for In3+ detection was proposed. In3+ ion was chelated with alizarin red S to form a complex In‐ARS. The complex was used as the template molecule to prepare a molecularly imprinted polymer (MIP) based sensor. The selectivity of the sensor was improved significantly due to the three‐dimensional specific structure of the complex, and the selective complexation of ligands for metal ions. Moreover, the sensitivity of the proposed sensor was improved by recording the reductive current of ligand in complex. This technique was highly sensitive for quantitative analysis of In3+ in the concentrations ranged from 1×10?8 mol/L to 2.5×10?7 mol/L with a detection limit of 4.7×10?9 mol/L. The proposed sensor has been successfully used in detecting In3+ in real samples.  相似文献   

3.
A novel molecularly imprinted sensor was firstly prepared based on a carbon nanotubes/graphene composite modified carbon electrode (MIPs/CNT/GP/CE) for the selective determination of bovine serum albumin. The molecularly imprinted sensor was tested by differential pulse voltammetry (DPV) to investigate the relationship between the response current and bovine serum albumin concentration. The results showed that a wide linear range (1.0×10?4 to 1.0×10?10 g mL?1) for the detection of bovine serum albumin with a low detection limit of 6.2×10?11 g mL?1 for S/N=3 was obtained. The novel imprinted sensor exhibited high selectivity, sensitivity, and reproducibility, which provided an applicable way for sensor development.  相似文献   

4.
Shabi Abbas Zaidi 《Electrophoresis》2013,34(9-10):1375-1382
To extend the application of molecularly imprinted polymers, the dual‐templates molecularly imprinted monolithic columns were developed in a capillary format. Two templates serotonin and histamine were simultaneously imprinted using two different functional monomers such as methacrylic acid (MAA) and methylenesuccinic acid (MSA) in a mixture of ethylene glycol dimethacrylate (EDMA) as a cross‐linker and AIBN as polymerization initiator dissolved in DMF as porogen. The resulting molecular imprinted polymers (MIPs) were characterized based on their performance in the CEC separation of two imprinted templates. The optimization parameters such as pH, ACN composition, and concentration of the eluent were varied to achieve best resolution and efficiency for CEC separation of templates with each MIP column. It was found that the MIP monolith column fabricated using MSA offered better resolution and separation efficiency compared to column fabricated with MAA. This work utilized the dual‐templates imprinting approach successfully and broadens the scope of multi‐templates imprinting capabilities in capillary format in CEC application.  相似文献   

5.
An imprinted fluorescent sensor was fabricated based on SiO2 nanoparticles encapsulated with a molecularly imprinted polymer containing allyl fluorescein. High fluorine cypermethirin as template molecules, methyl methacrylate as functional monomer, and allyl fluorescein as optical materials synthesized a core‐shell fluorescent molecular imprinted sensor, which showed a high and rapid sensitivity and selectivity for the detection of τ‐fluvalinate. The sensor presented appreciable sensitivity with a limit of 13.251 nM, rapid detection that reached to equilibrium within 3 min, great linear relationship in the relevant concentration range from 0 to 150 nM, and excellent selectivity over structural analogues. In addition, the fluorescent sensor demonstrated desirable regeneration ability (eight cycling operations). The molecularly imprinted polymers ensured specificity, while the fluorescent dyes provided the stabile sensitivity. Finally, an effective application of the sensor was implemented by the detection of τ‐fluvalinate in real samples from vodka. The molecularly imprinted fluorescent sensor showed a promising potential in environmental monitoring and food safety.  相似文献   

6.
A novel sensor for the determination of parathion‐methyl based on couple grafting of functional molecular imprinted polymers (MIPs) was fabricated which is developed by anchoring the MIP layer on surfaces of silica particles embedded CdSe quantum dots by surface imprinting technology. The synthesized molecular imprinted silica nanospheres (CdSe@SiO2@MIP) allow a high selectivity and sensitivity of parathion‐methyl via fluorescence intensity decreasing when the MIP material rebinding the parathion‐methyl molecule. Compared with the MIP fabricated in traditional method, the template of parathion‐methyl was easier to remove from the CdSe@SiO2@MIP imprinted material. Under optimal conditions, the fluorescence intensity of parathion‐methyl at the imprinted sensor was detected by spectrofluorophotometer. The relative fluorescence intensity of CdSe@SiO2@MIP decreased linearly with the increasing concentration of parathion‐methyl ranging from 0.013 mg·kg−1 to 2.63 mg·kg−1 with a detection limit (3δ) of 0.004 mg·kg−1 (S/N=3), which is lower than the MIP in tradition. The imprinted film sensor was applied to detect parathion‐methyl in vegetable samples without the interference of other organophosphate pesticides and showed a prosperous application in the field of food safety.  相似文献   

7.
We have examined the specificity of electrosynthesized poly-o-phenylenediamine as a kind of material molecularly imprinted with metal chelates. Molecularly imprinted polymers (MIPs) were prepared in situ by an electrochemical method. The EDTA chelate complexes of Cu(II), Zn(II), Fe(III) and Cd(II) ions were used as templates of the MIPs deposited on a gold electrode of a quartz crystal microbalance (QCM). The binding ability and specificity of the MIPs were investigated via the frequency response of the QCM to the adsorption of the template chelates and their analogs. Linear relationships are observed between the frequency shift and the concentration of the template chelates over a typical range of ~10?6 to ~10?4?mol·L?1. The results reveal good binding specificity of such MIPs for their templates over structurally related analogs, but the selectivity coefficients are less significant than that for enantiomers. The results also suggest no significant correlation between binding specificity and the ionic (or atomic) radius of the investigated metal ions. The observed specificity is qualitatively attributed to the overall conformational difference of the metal-EDTA complexes resulting from their difference in both ionic radius and electronic structures.
Figure
Schematic Representation of the Molecular Imprinting Procedures. The metal ions chelate with EDTA to form metal-EDTA chelates as the template, then polymerization is initiated by an electrochemical method. After the polymerization, the templates are removed to create cavities in the polymer film which have binding ability and specificity to the templates.  相似文献   

8.
A novel strategy to improve the sensitivity of molecularly imprinted polymer (MIP) sensors was proposed for the determination of β2‐agonists. The imprinted sol‐gel film was prepared by mixing silica sol with a functional monomer of antimony‐doped tin oxide (ATO) and a template of β2‐agonists. ATO, which was embedded in the surface of the molecularly imprinted sol‐gel film, not only provides the excellent conductivity for biosensor but also increases the stability and the surface area of the MIP film. The imprinted sensor was characterised by field emission scanning electron microscope, fourier transform infrared spectroscopy and electrochemical methods. Under the optimal experimental conditions, the peak current was linear with the logarithm of the concentration of clenbuterol (CLB) in the range of 5.5 nM–6.3 µM, and a detection limit of 1.7 nM was obtained. Meanwhile, the electrochemical sensor showed excellent specific recognition of the template molecule among structurally similar coexisting substances. Furthermore, the proposed sensor was satisfactorily applied to determine β2‐agonists in human serum samples. The good results indicated that highly effective molecularly imprinted sol‐gel films doped with ATO can be employed for other analytes.  相似文献   

9.
《Analytical letters》2012,45(7):1117-1131
A molecularly imprinted electrochemical sensor was fabricated based on a gold electrode modified by chitosan-multiwalled carbon nanotube composite (CS-MWCNTs) multilayer films and gold nanoparticles (AuNPs) for convenient and sensitive determination of oxytetracycline (OTC). The multilayer of CS-MWCNTs composites and AuNPs were used to augment electronic transmission and sensitivity. The molecularly imprinted polymers (MIPs) were synthesized using OTC as the template molecule and o-phenylenediamine (OPD) as the functional monomer. They were modified on a gold electrode by electropolymerization. The electrochemical behavior of OTC at the imprinted sensor was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), and amperometry. The molecularly imprinted sensor showed high selectivity and excellent stability toward OTC. The linear range was from 3.0 × 10?8 to 8.0 × 10?5 mol/L, with a limit of detection (LOD) of 2.7 × 10?8 mol/L (S/N = 3). The developed sensor showed good recovery in spiked samples analysis.  相似文献   

10.
This work was designed to develop an electrochemical sensor based on molecular imprinted polyaniline membranes onto reduced graphene oxide (RGO) and gold nanoparticles (AuNPs) modified glassy carbon (GC) electrode for dapsone (DDS) determination. The prepared RGO/AuNPs/PANI‐MIPs nanocomposite was characterized by Ultra‐Violet‐Visible (UV‐Vis), Fourier transform infrared spectroscopy (FT‐IR) and scanning electronic microscopy (SEM) images. The feature of the imprinted electrode was evaluated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and impedance spectroscopy (IS). Throughout this study several analytical parameters, such as incubation time, pH value, concentration of monomer/template molecules and electro‐polymerization cycles were investigated. Under the optimized conditions, the experimental results showed best analytical performances for DDS detection with a sensitivity of 0.188 Ω/mol L?1, a linear range from 1.0×10?7 M to 1.0×10?3 M and a detection limit of 6.8×10?7 M. The bioanalytical sensor was applied to the determination of dapsone in real samples with high selectivity and recovery.  相似文献   

11.
A novel molecularly imprinted polymers (MIPs) coated micro‐stir bar (MSB) for Glibenclamide (GM) was developed. The MIPs, with GM as template molecular and methacrylic acid as functional monomer, were synthesized at the surface of the silylated MSB that was filled with magnetic core as substrate. Computational simulation was used for the optimal selection of functional monomers and porogen. The thickness of MIPs coating for MSB was about 10 μm, the adsorption and desorption time were about 40 and 20 min, respectively. The MIPs coated MSB possessed mechanical stability, high adsorption capacity, and good selectivity for GM. To achieve the optimum extraction performance, several parameters including extraction and desorption time, stirring rate, extraction and desorption solvent were investigated. A method for the determination of GM in herbal dietary supplements by MIPs coated MSB coupled with HPLC‐UV was established. The results exhibited good linear ranges of 10–6250 μg L?1 with the low limit of detection of GM (3.05 μg L?1) and the good recoveries (81.9–101.4%).  相似文献   

12.
An electrochemical sensor for doxycycline hyclate(DC)detection with high sensitivity and good selectivity is reported.The sensor was fabricated by electro-polymerization of molecularly imprinted polymers(MIPs)in the presence of DC onto multi-walled carbon nanotubes modified glassy carbon electrode(MWCNTs/GCE).The MWCNTs can significantly increase the current response of the sensor,leading to enhanced sensitivity.The MIPs provide selective recognition sites for DC detection.The experimental parameters,such as the polymer monomer concentration,supporting electrolyte pH,the time for electro-polymerization and the incubation time of the sensor with DC were optimized.Under optimized experimental conditions,the sensor displayed a linear range of 0.05μmol/L-0.5μmol/L towards DC detection,with the detection limit of 1.3×10^-2μmol/L.The sensor was successfully applied for recovery test of DC in human serum samples.  相似文献   

13.
A sensitive molecularly imprinted electrochemical sensor was created for selective detection of a tricyclic antidepressant imipramine by combination of Au nanoparticles (Au-NPs) with a thin molecularly imprinted film. The sensor was fabricated onto the indium tin oxide (ITO) electrode via stepwise modification of Au-NPs by self-assembly and a thin film of molecularly imprinted polymers (MIPs) via sol-gel technology. It was observed that the molecularly imprinted film displayed excellent selectivity towards the target molecule imipramine. Meanwhile, the introduced Au-NPs exhibited noticeable catalytic activities towards imipramine oxidation, which remarkably enhanced the sensitivity of the imprinted film. Due to such combination, the as-prepared sensor responded quickly to imipramine, within only 1 min of incubation. The differential voltammetric anodic peak current was linear to the logarithm of imipramine concentration in the range from 5.0 × 10−6 to 1.0 × 10−3 mol L−1, and the detection limits obtained was 1.0 × 10−9 mol L−1. This method proposed was successfully applied to the determination of imipramine in drug tablets, and proven to be reliable compared with conventional UV method. These results reveal that such a sensor fulfills the selectivity, sensitivity, speed and simplicity requirements for imipramine detection, and provides possibilities of clinical application in physiological fluids.  相似文献   

14.
Despite the increasing number of applications of molecularly imprinted polymers (MIPs) in analytical chemistry, the construction of a biomimetic potentiometric sensor remains still challenging. In this work, a biomimetic potentiometric sensor, based on a non‐covalent imprinted polymer was fabricated for the recognition and determination of cetirizine. The MIP was synthesized by precipitation polymerization, using cetirizine dihydrochloride as a template molecule, methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross linking agent. The sensor showed high selectivity and a sensitive response to the template in aqueous system. The MIP‐modified electrode exhibited Nernstian response (28.0±0.9 mV/decade) in a wide concentration range of 1.0×10?6 to 1.0×10?2 M with a lower detection limit of 7.0×10?7 M. The electrode has response time of ca. 20 s, high performance, high sensitivity, and good long term stability (more than 5 months). The method was satisfactory and used to the cetirizine assay in tablets and biological fluids.  相似文献   

15.
Molecularly imprinted polymers (MIPs) for citrinin (Cit) with 1‐hydroxy‐2‐naphthoic acid (HNA) as mimic template were prepared and the molecularly imprinted SPE method was developed for the detection of Cit in rice with HPLC. The adsorption properties of HNA and Cit on the MIPs and nonimprinted polymers were investigated. It proved that MIPs showed higher selectivity adsorption to HNA and Cit than nonimprinted polymers were. The recoveries of Cit in rice were in the range of 86.7–97.7%. The spiked rice samples and five rice samples in Beijing market were detected using molecularly imprinted SPE method and satisfied results were obtained as discussed in this article.  相似文献   

16.
A novel metal‐ion‐mediated complex‐imprinted‐polymer‐coated solid‐phase microextraction (SPME) fiber used to specifically recognize thiabendazole (TBZ) in citrus and soil samples was developed. The complex‐imprinted polymer was introduced as a novel SPME coating using a “complex template” constructed with Cu(II) ions and TBZ. The recognition and enrichment properties of the coating in water were significantly improved based on the metal ion coordination interaction rather than relying on hydrogen bonding interactions that are commonly applied for the molecularly imprinting technique. Several parameters controlling the extraction performance of the complex‐imprinted‐polymer‐coated fiber were investigated including extraction solvent, pH value, extraction time, metal ion species, etc. Furthermore, SPME coupled with HPLC was developed for detection of TBZ, and the methods resulted in good linearity in the range of 10.0–150.0 ng/mL with a detection limit of 2.4 ng/mL. The proposed method was applied to the analysis of TBZ in spiked soil, orange, and lemon with recoveries of 80.0–86.9% and RSDs of 2.0–8.1%. This research provides an example to prepare a desirable water‐compatible and specifically selective SPME coating to extract target molecules from aqueous samples by introducing metal ions as the mediator.  相似文献   

17.
A sensitive molecularly imprinted electrochemical sensor with specific recognition ability for oleanolic acid was synthesized by modification of multiwalled carbon nanotubes (MWNTs) decorated with tin oxide nanoparticles (nano‐SnO2/MWNTs) and polypyrrole‐imprinted polymer on a carbon electrode. The morphology and electrochemical performance of the imprinted sensor were investigated by using scanning electron microscope (SEM), X‐ray diffraction (XRD), cyclic voltammetry (CV), linear sweep voltammetry (LSV) and amperometric it curve. The results showed that the imprinted sensor displayed excellent selectivity toward oleanolic acid. A linear relationship between the response currents and oleanolic acid concentrations ranging from 5.0×10?8 g/L to 2.0×10?5 g/L was obtained for the imprinted sensor. The limit of detection (LOD) of the imprinted sensor toward oleanolic acid was calculated as 8.6×10?9 g/L at a signal to noise ratio (S/N) of 3. This imprinted sensor was successfully applied to the determination of oleanolic acid in Acitinidia deliciosa root samples.  相似文献   

18.
A novel electrochemical sensor for diisononyl phthalate (DINP) analysis was investigated. The sensor was modified on a glassy carbon electrode (GCE) with DINP molecularly imprinted polymer particles (MIPs). The electrode was assembled by the mixture of MIPs and agarose in proportion. The MIPs were formed by bulk polymerization via non-covalent multiple interactions, which were further characterized by scanning electron microscopy (SEM). The linear response range of the MIP sensor was between 50 and 1000 nM, and the limit of detection (LOD) was 27 nM. The proposed system has the superiority of high-speed real-time detection capability, no sample pretreatment, simple operation process, little detection cost, short detection time, high sensitivity, low interference and good stability. Therefore, it shows the potential for application in food safety supervision of DINP.  相似文献   

19.
The proposed L ‐histidine sensing system composed of a molecularly imprinted solid‐phase microextraction component combined with a molecularly imprinted polymer sensor was used to determine critical levels of test analyte in a complex matrix of highly diluted human blood serum without any non‐specific sorption and false‐positive contributions. The molecularly imprinted polymer was a zwitterionic polymer brush derived from the disodium salt of EDTA and chloranil, grafted to solid‐phase microextraction material. The hyphenated approach was able to detect L ‐histidine quantitatively with a limit of detection as low as 0.0435 ng/mL (RSD = 0.2%, S/N = 3).  相似文献   

20.
A novel nanocomposite of molecularly imprinted polymers and graphene sheets was fabricated and used to obtain a highly conductive acetylene black paste electrode with high conductivity for the detection of bisphenol A. The two‐dimensional structure and the chemical functionality of graphene provide an excellent surface for the enhancement of the sensitivity of the electrochemical sensor and the specificity of molecularly imprinted polymers to improve detection of bisphenol A. The synergistic effect between graphene and molecularly imprinted polymers confers the nanocomposite with superior conductivity, broadened effective surface area and outstanding electrochemical performance. Factors affecting the performance of the imprinted sensor such as molecularly imprinted polymers concentration, foster time and scan rate are discussed. The sensor successfully detects bisphenol A with a wide linear range of 3.21 × 10?10 to 2.8 × 10?1 g/L (R = 0.995) and a detection limit of 9.63 × 10?11g/L. The fabricated sensor also possessed high selectivity and stability and exhibits potential for environmental detection of contaminants and food safety inspection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号