首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Evaluation of immunoaffinity columns (IACs) for dioxin serum sample clean-up requires a determination of the recovery of various dioxin congeners. We compared the IAC performance of different monoclonal and polyclonal anti-dioxin antibodies, measuring the recovery of congeners of polychlorinated dibenzo-p-dioxins (PCDDs). In addition, we measured the recovery of congeners of the structurally related polychlorinated dibenzofurans (PCDFs).The polyclonal antibody based IACs evaluated had lower recovery for highly chlorinated dioxin congeners, but were more specific toward 2,3,7,8-TCDD. The resemblance of the hapten to 2,3,7,8-TCDD appeared to play a clear role, but chlorines in the 2-, 3- and 7-positions of the hapten were essential. Recovery of 2,3,7,8-TCDD from the IAC showed some relation to the affinity for the antibody measured by either the Ka from accelerator mass spectrometry (AMS) or with 50% inhibition of color activity (IC50) determined from an ELISA analysis.The IACs prepared from four monoclonal antibodies (Mabs) derived from a common hapten showed differences in their retention patterns of PCDDs/PCDFs. Comparison of IC50 from ELISA with recovery from the IACs indicated that a minimum IC50 of 100 ppb was required for satisfactory recovery from the IAC, but the correlation was poor, indicating other factors were involved. Mab DD3 showed the broadest spectrum of the Mabs and showed satisfactory recoveries of all of the dioxin congeners, except OCDD. In addition, DD3 showed good recovery toward 2,3,4,8-TCDF, 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF but has poor recovery when PCDFs have a chlorine substitution in the 1-position.  相似文献   

2.
A high-performance liquid chromatographic cleanup procedure employing normal-phase alumina and carbon--silica separations was developed for isolating polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) from other polychlorinated pollutants present in fish tissue. The method utilizes a column-switching step where the dioxins and furans are trace enriched onto a carbon-silica column as they are eluted from the alumina column. Interfering components such as polychlorinated biphenyls and chlorinated diphenyl ethers elute through the carbon--silica column. The PCDDs and PCDFs are subsequently recovered by backflushing the carbon--silica column using toluene.  相似文献   

3.
A simultaneous steam distillation-solvent extraction (SDE) procedure was used for determining polychrlorinated biphenyls, polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCBs, PCDDs and PCDFs) at sub-ppb levels in water samples. Recoveries of 39.8–138.7% and a standard deviation of lower than 10% were achieved for the individual coplanar PCB and the 2,3,7,8-substituted PCDD/F congeners. SDE is a fast, clean, inexpensive and reproducible procedure for the determination of individual PCBs, PCDDs and PCDFs in waters at very low concentrations.  相似文献   

4.
Matrix–matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.  相似文献   

5.
Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.  相似文献   

6.
Summary Polychlorinated Dibenzo-p-dioxins (PCDD) and Dibenzofurans (PCDF) in fly ash samples from coalburning power plants in Greece have been determined by high resolution gas chromatography combined with mass spectrometric detection (HRGC-MS) applying the isotopic dilution technique. Concentrations of PCDFs were 20 to 600 fold higher than for PCDDs. The concentrations of PCDDs and PCDFs were in the range of 11–62 and 1254–7180 pg/g respectively. Fly ashes from coal-burning power plants were found to be potential sources of PCDFs.  相似文献   

7.
2014年1月在杭州市选择5个点位采集大气颗粒物PM2.5样品,采用同位素稀释高分辨气相色谱/高分辨质谱测定PM2.5中的二恶英(PCDD/Fs)和多氯联苯(PCBs),对PM2.5的污染状况以及PM2.5中PCDD/Fs和PCBs的污染水平及分布特征进行了研究。PM2.5的质量浓度范围为85~168 μg/m3,PM2.5污染较重,但与2004年同期相比明显降低。PM2.5中PCDD/Fs的毒性当量(TEQ)为0.277~0.488 pg I-TEQ/m3,明显高于2004年同期采集样品。颗粒物中PCDD/Fs以八氯代二苯并-对-二恶英(OCDD)为主,毒性当量主要贡献者为2,3,4,7,8-五氯代二苯并呋喃(2,3,4,7,8-PeCDF)。PM2.5中PCBs的质量浓度范围为2.9~8.1 pg/m3,二恶英类多氯联苯(DL-PCBs)的毒性当量范围为2.6~6.1 fg WHO-TEQ/m3,污染较低。PCBs在颗粒物中分布以PCB-28为主,但对毒性当量贡献最大的为PCB-126。PCDD/Fs和PCBs的气-固分配特征表现为PCDD/Fs主要分布于颗粒物中,而PCBs主要分布于气相中。  相似文献   

8.
Polychlorinated naphthalenes (PCNs) are candidates for inclusion in the Stockholm Convention on persistent organic pollutants. PCNs are structurally and toxicologically similar to 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) and its analogues. Intake in food is considered to be an important human exposure pathway for PCNs. In this preliminary study, cheese and butter samples were analysed for PCNs, polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) using an isotope dilution gas chromatography high-resolution mass spectrometry method. The aim of this study was to evaluate the PCN concentrations in the cheese and butter samples and to compare them with the PCDD, PCDF and PCB concentrations. The PCN concentrations were 5.6–103 pg g?1 of wet weight in the seven cheese samples tested and 5.0–199 pg g?1 of wet weight in the seven butter samples tested. The mass concentrations of lower chlorinated congeners were greater than those of the higher chlorinated congeners. Congeners of CN45/36, CN27/30 and CN33/34/37 were much more abundant than other congeners found in tetrachlorinated PCNs. Congeners of CN51, CN66/67 and CN73 were determined to be the predominant congeners in penta-, hexa- and heptachlorinated homologs, respectively. The PCNs contributed around 5% of the total PCN, PCDD, PCDF and PCB toxic equivalence (TEQ) values. CN73 was found to be the dominant PCN congener and contributed more than 40% to the PCN TEQ value. Congeners CN66/67, CN69 and CN63 were also found at relatively high levels. The PCB congener CB118 was the predominant congener (by mass-based concentration) of the 12 dioxin-like PCBs (dl-PCBs). The PCBs contributed 53.8% of the total TEQ, and congener CB126 contributed more than any other compound that was analysed to the total TEQ. The PCDDs and PCDFs contributed 11.6% and 29.7% of the total TEQ values, respectively.  相似文献   

9.
Comprehensive Gas Chromatography-Time-of-Flight Mass Spectrometry (GC×GC-TOFMS) methodology has been refined for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in samples with different matrices. This is specifically for application in developing countries where access to gas chromatography-high resolution mass spectrometry (GC-HRMS) and highly skilled personnel is limited. The method, using an Rxi-5 Sil MS column in the first dimension ((1)D) coupled with an Rtx-200 column in the second dimension ((2)D), was used to quantify PCDDs and PCDFs in different environmental sample matrices. The results were compared with those obtained using GC-HRMS and good agreement was observed. The limit of detection (LOD) for the method (300fg on column for spiked soil samples) was determined using an Rxi-XLB ((1)D) column coupled with an Rtx-200 column ((2)D). Preliminary South African sample results are also discussed. Isomer specificity for different tetrachloro dibenzo-p-dioxins (TCDDs) and tetrachloro dibenzofurans (TCDFs) was investigated using a commercial standard. Adequate resolution was achieved. The method as described has great attraction for developing countries being both financially and operationally favourable.  相似文献   

10.
Separations of 12 compound classes, polychlorinated biphenyls (PCBs), diphenyl ethers (PCDEs), naphthalenes (PCNs), dibenzothiophenes (PCDTs), dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), terphenyls (PCTs) and alkanes (PCAs), toxaphene, organohalogenated pesticides (OCPs), and polybrominated biphenyls (PBBs) and diphenyl ethers (PBDEs) by comprehensive two-dimensional gas chromatography were evaluated. Five column combinations, DB-1 x 007-210, DB-1 x HT-8, DB-1 x LC-50, DB-1 x 007-65HT and DB-1 x VF-23ms were used to study, primarily, group-type separations, but attention was devoted also to within-class separation, especially for those classes which were not addressed in much detail before, the PCNs, OCPs, PBBs and PCTs. The DB-1 x 007-210 column set did not offer any extra separation compared to one-dimensional GC. For the DB-1 x HT-8 column combination, the useful principle of congener separation on the basis of number of halogen substituents in a molecule was confirmed (PCBs, toxaphene) and extended (PCTs, PBDEs). No practically useful group-type separation was observed for this column combination. The DB-1 x LC-50 set provides group separation based on planarity: planar compounds such as PCDDs, PCDFs, PCDTs and PCNs are much more retained than, and therefore separated from, non-planar analytes. Within the classes of PCBs, PBBs and PCTs highly useful separation of planar from non-planar compounds was also observed. The DB-1 x 007-65HT column set effectively separates PCAs and PBDEs from all other compound classes, and provides a good separation of brominated and chlorinated analogue classes from each other. This column set was the most efficient one for within-class separation of OCPs and PCNs. Finally, DB-1 x VF-23ms yields excellent within-class separations, especially of non-aromatic compounds, viz. OCPs, toxaphene and PCAs. No group separation was observed here. The applicability of the approach was demonstrated for a sediment extract and a dust extract. In the sediment extract, PCDDs, PCDFs, PCAs and PCNs were identified and their efficient separation was achieved. In the dust sample, separation of PCAs and PBDEs was achieved and several new PBDE congeners were identified.  相似文献   

11.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in slag of fly ash from three municipal solid waste (MSW) incinerators were analyzed to observe any changes in characteristics and distribution of their congeners by melting process. Actual concentration and Toxic Equivalent (TEQ) concentration profiles of 17 major congeners of PCDDs/PCDFs for gas, fly ash and melted slag were compared. The distributions of PCDDs/PCDFs in different streams macroscopically showed similarities with the generally known profiles for emission gas from a municipal waste incinerator. The total concentrations of PCDDs/PCDFs in off-gas and fly ash have been known to be a function of incineration conditions and of air pollution control device utilization; however, their normalized distributions were independent of such conditions. The concentrations of PCDDs/PCDFs in the melted slag of fly ash were not related to the concentrations of PCDDs/PCDFs congeners in fly ash but were rather a function of the melting furnace type and operation. The total amount of PCDDs/PCDFs in the melted slag of fly ash contained almost 150–27,000 times less dioxin than that in fly ash, however, the TEQ of dioxin in the slag was reduced by 435–43,500 times, which could enable them to be utilized as recycled construction materials. In normalized TEQ concentration profiles of 17 congeners of PCDDs/PCDFs, the ratio of PCDFs to PCDDs changed from 1.32 to 2.19 by melting, which showed relatively higher portion of furans left in melted slag than those in fly ash. By comparing reduction ratios of different congeners, PCDDs (dioxins) were relatively easier to destruct than PCDFs (furans) during melting process. The most difficult congener to destruct could be octa-chlorinated dibenzofuran (OCDF) among major congeners. For slag cooling methods, dioxin concentration in TEQ of slow cooled slag by air was four times higher than that of fast cooled slag by water. Thus cooling by water is more appropriate with the added beneficial effect of producing granules/particles, which can be utilized as roadbed materials.  相似文献   

12.
A solid-phase extraction (SPE) method was optimized for accurate determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and coplanar polychlorinated biphenyls (CoPCBs) in humic acid containing surface water. Recovery experiments using humic materials revealed that humic acids permit dioxins to pass through an octadecylsilica (C18) extraction disk by associating with them under weakly alkaline conditions. Acidification of the sample before percolation improved this otherwise insufficient recovery. The analysis of surface water acidified to pH 2 gave better recovery with surrogate standards and lower quantitative values for higher-chlorinated homologues than the sample at pH 9. In all samples, the native octachlorodibenzo-p-dioxin (OCDD) peak abundance showed no difference between at pH 2 and at pH 9, indicating overestimation of the quantitative value of the homologue at pH 9. Acidification of a humic acid containing water sample can avoid overestimation of higher-chlorinated congeners caused by insufficient recovery of their corresponding surrogates.  相似文献   

13.
 The chromatographic behavior of ortho and non-ortho polychlorinated biphenyls (PCBs) on supported carbon columns has been investigated and the structure-affinity relationship of activated carbon towards PCB molecules established. Optimisation of the parameters controlling the elution of PCB congeners through the carbon column led to the development of a solvent scheme for the efficient separation of (i) ortho substituted PCBs, (ii) non-ortho substituted PCBs and (iii) polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in three separate fractions. A method for the extraction, clean-up, fractionation and determination of ortho and non-ortho substituted PCBs by GC-isotope dilution MS was developed and validated by analysis of a certified reference material. Possible losses of PCBs during freeze-drying and interferences of aliphatic hydrocarbons during mass spectrometric determination of ortho substituted PCBs are also discussed. Received: 23 June 1995/Revised: 9 May 1996/Accepted: 25 May 1996  相似文献   

14.
Summary A procedure is described for the selective separation of 2,3,7,8-TCDD from all other PCDDs and PCDFs. For this purpose the mixture of PCDDs and PCDFs is fractionated on Alumina Woelm B Super I in such a manner that all PCDDs and PCDFs are eluted prior to 2,3,7,8-TCDD. This procedure allows a more sensitive quantitative determination of 2,3,7,8-TCDD in samples which contain 2,3,7,8-TCDD only as a very minor fraction of the other TCDDs or PCDDs and PCDFs. Determination of 2,3,7,8-TCDD in pentachlorophenol and in a waste sample from 2,4-dichlorophenol production by this procedure is described.
Selektive Bestimmung von 2,3,7,8-Tetrachlordibenzo-p-dioxin in Gegenwart eines großen Überschusses anderer polychlorierter Dibenzodioxine und polychlorierter Dibenzofurane
Zusammenfassung Ein Verfahren wird beschrieben, das die selektive Abtrennung von 2,3,7,8-TCDD aus einer Mischung von allen PCDDs und PCDFs erlaubt. Dies geschieht durch Fraktionierung an Alumina Woelm B Super I, wodurch eine getrennte Elution aller PCDDs und PCDFs von 2,3,7,8-TCDD erreicht werden kann. Dieses Verfahren erlaubt die quantitative Bestimmung von 2,3,7,8-TCDD mit höherer Nachweisempfindlichkeit in Proben, die andere TCDDs bzw. PCDDs und PCDFs in extremen Überschüssen im Vergleich zu 2,3,7,8-TCDD enthalten. Am Beispiel der Bestimmung von 2,3,7,8-TCDD in Pentachlorphenol und in einem Produktionsrückstand von 2,4-Dichlorphenol wird die praktische Anwendbarkeit nachgewiesen.


This work was supported by the Ministerium für Ernährung, Landwirtschaft, Umwelt und Forsten, Baden-Württemberg.The skilfull technical assistance of Roland Kerzenmacher is acknowledged.  相似文献   

15.
The efficiency of hot alkaline digestion of a sample matrix was investigated for determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and coplanar polychlorinated biphenyls (CoPCBs) in biological samples. Results of recovery tests of octachlorodibenzofuran (OCDF) after spiking into lean tuna showed degradation of OCDF and the production of a large quantity of lower-chlorinated dibenzofurans (LoCDFs) when the sample was digested with hot ethanolic KOH. However, it was also confirmed that pyrogallol (PG) prevented dechlorination of OCDF. The accuracy of the hot alkaline digestion method with PG was demonstrated by analyzing PCDD/Fs-spiked lean tuna. The proposed method is more suitable than conventional versions for the determination of dioxins in biological samples in terms of savings in time, adequate digestion of matrix and high degree of recovery of internal standards.  相似文献   

16.
Gas chromatography coupled to ion trap tandem mass spectrometry (CG-MS-MS) has been evaluated for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) in vegetable oil samples containing different concentration levels (0.2-6 pg WHO-TEQ g(-1) for both PCDD/Fs and dl-PCBs) of the 29 toxic congeners of PCDD/F and dioxin-like PCBs. The effect of potential interfering compounds such as polychlorinated naphthalenes (PCNs), polychlorinated biphenyls (PCBs) and polychlorinated diphenylethers (PCDEs) on the quantification of mono-ortho PCBs has been investigated. In addition, the influence of the clean-up procedure on the final determination by CG-MS-MS was studied, showing that the quality of the results depends to a great extent on this analytical step. Quality parameters have been established and good precisions (CV: 3-19%) and low limits of detection for PCDD/Fs (0.04-0.20 pg g(-1) oil) and dl-PCBs (0.08-0.64 pg g(-1) oil) were obtained. The method was validated by a comparison of the CG-MS-MS results with those obtained by GC-HRMS.  相似文献   

17.
Method validation was performed on the collection and extraction procedures for an analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DLPCBs) in flue gas. The adoption of the rapid pressurized liquid extraction (PLE) technique was evaluated for extraction from polyurethane foam plugs (PUFPs) and fly ash. With respect to extraction from PUFPs, dichloromethane PLE showed an extraction efficiency equivalent to that of conventional acetone Soxhlet, while toluene PLE was found to have a lower extraction efficiency from fly ash than toluene Soxhlet. The collection ability of three sampling methods, employed in the Japanese standard analytical method JIS K0311 (revised in 2005) was evaluated by evaluating the distribution of gaseous PCDD/Fs and DLPCBs in each collection compartment in sampling trains. A DiOANA® fibrous alumina filter and a PUFP, newly employed trapping devices in the revised JIS method, were found to trap gaseous analytes effectively. The validation of the two newly employed sampling methods (DiOANA and PUFP) was tested by parallel measurements of the methods with a conventional five-impinger method, and good agreements on the PCDD/Fs and DLPCBs quantities were demonstrated.  相似文献   

18.
This article reviews recent literature on the analysis of industrial contaminants in indoor air in the framework of the REACH project, which is mainly intended to improve protection of human health and the environment from the risks of more than 34 millions of chemical substances. Industrial pollutants that can be found in indoor air may be of very different types and origin, belonging to the volatile organic compounds (VOCs) and semivolatile organic compounds (SVOCs) categories. Several compounds have been classified into the priority organic pollutants (POPs) class such as polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins and furans (PCDD/PCDFs) and related polychlorinated compounds, and polycyclic aromatic hydrocarbons (PAHs). Many of these compounds are partially associated to the air gas phase, but also to the suspended particulate matter. Furthermore, settled dust can act as a concentrator for the less volatile pollutants and has become a matrix of great concern for indoors contamination. Main literature considered in this review are papers from the last 10 years reporting analytical developments and applications regarding VOCs, aldehydes and other carbonyls, PCBs, PCDDs, PCDFs, and PAHs in the indoor environment. Sample collection and pretreatment, analyte extraction, clean-up procedures, determination techniques, performance results, as well as compound concentrations in indoor samples, are summarized and discussed. Emergent contaminants and pesticides related to the industrial development that can be found in indoor air are reviewed in a second part in this volume.  相似文献   

19.
A method consisting of automated supercritical fluid extraction (SFE) with simultaneous cleanup by a solid-phase trap was developed for fast analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil. SFE was optimised to replace conventional liquid-based methods in routine analyses of PCDD/PCDFs in sawmill soil contaminated by a chlorophenol formulation. PCDD/PCDFs were quantitatively extracted in 60 min using CO2 at 400 atm and 100 degrees C without a modifier. A trap containing a small amount of activated carbon mixed with Celite efficiently collected PCDD/PCDFs after SFE. After SFE co-extracted impurities were eluted out from the trap with 4 ml of hexane and PCDD/PCDFs were eluted with 10 ml of toluene. The concentrations and TCDD-equivalent of PCDD/PCDFs corresponded to the results of traditional solvent extraction method (Soxhlet) in six sawmill soils tested. The performance of the trap was maintained over a long period of time (nearly 100 extractions).  相似文献   

20.
Pressurized liquid extraction with an integrated carbon trap (PLE-C) has recently been developed for fast and efficient analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in food and feed. The method has also been tested, but not verified, for use on more complex soil samples, such as soil, sediment and fly ash. Hence, the primary aim of this study was to verify that PLE-C can produce reliable data for PCDDs/PCDFs in various abiotic matrixes. A second aim was to find a replacement for the previously used AX21 active carbon that is currently not commercially available. The performance of the PLE-C was evaluated using both single congener concentrations and toxic equivalency potentials (TEQ-pot) of three (soil, sediment and fly ash) certified reference materials. The results clearly show that PLE-C can be used for abiotic samples and that a commercially available carbon (Norit SA 4PAH HF) can replace the AX-21 carbon in the carbon trap. The TEQ-pot values obtained for the soil and sediment samples were within the uncertainty limits of the corresponding certified values, as were the determinations of single congener concentrations. PLE-C therefore has great potential for determination of PCDDs/PCDFs in soil and sediment samples. The TEQ-pot result for the fly ash was slightly lower than the certified TEQ-pot value, but it is still within the uncertainty limits of the certified value. Out of the single congener concentrations all but four (out of 17) agreed well with the values. Hence, PLE-C may potentially be used also for fly ash—after slight modifications. The integrated PLE-C and cleanup procedure is less labour-intensive than traditional methods such as Soxhlet extraction followed by a multistep cleanup, and consumes smaller quantities of ultrapure solvents than the commonly used Power-Prep system. In addition, PLE-C is capable of larger sample throughputs than the conventional methods. Thus, PLE-C is a promising alternative to the currently used sample preparation procedures for dioxins in abiotic samples. Figure PLE with integraded carbon trap for rapid PCDD/Fs analysis Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号