首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g−1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of high-purity materials and environmental samples) is used in order to improve the detection limits of trace elements. Furthermore, the determination of chemical elements in the trace and ultratrace concentration range is often difficult and can be disturbed through mass interferences of analyte ions by molecular ions at the same nominal mass. By applying double-focusing sector field mass spectrometry at the required mass resolution—by the mass spectrometric separation of molecular ions from the analyte ions—it is often possible to overcome these interference problems. Commercial instrumental equipment, the capability (detection limits, accuracy, precision) and the analytical application fields of mass spectrometric methods for the determination of trace and ultratrace elements and for surface analysis are discussed.  相似文献   

2.
Doubly charged diatomic ions MAr2+ where M=Mg, Ca, Sr or Ba have been observed by mass spectrometry with an inductively coupled plasma ion source. Abundance ratios are quite high, 0.1 % for MgAr2+, 0.4 % for CaAr2+, 0.2 % for SrAr2+ and 0.1 % for BaAr2+ relative to the corresponding doubly charged atomic ions M2+. It is assumed that these molecular ions are formed through reactions of the doubly charged metal ions with neutral argon atoms within the ion source. Bond dissociation energies (D0) were calculated and agree well with previously published values. The abundance ratios MAr+/M+ and MAr2+/M2+ generally follow the predicted bond dissociation energies with the exception of MgAr2+. Mg2+ should form the strongest bond with Ar [D0 (MgAr2+)=124 to 130 kJ mol?1] but its relative abundance is similar to that of the weakest bound BaAr2+ (D0=34 to 42 kJ mol?1). The relative abundances of the various MAr2+ ions are higher than those expected from an argon plasma at T=6000 K, indicating that collisions during ion extraction reduce the abundance of the MAr2+ ions relative to the composition in the source. The corresponding singly charged MAr+ ions are also observed but occur at about three orders of magnitude lower intensity than MAr2+.  相似文献   

3.
Abstract

Kinetic studies of uptake of metal ions by the Chelex batch technique were made to determine Cd, Cu and Pb speciation in model solutions, a snow sample and a river surface water sample. Inductively-coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GFAAS) were used for direct determination of these metals. ICP-MS with the solution nebulization technique minimized contamination and adsorption problems involved in the discrete sampling technique of GFAAS, and hence, gave more precise and accurate results. Also, ICP-MS allowed collection of many more data points than GFAAS and was able to resolve components with similar rates of dissociation, which could not always be resolved by GFAAS with its discrete sampling technique. ICP-MS was therefore preferable to GFAAS for kinetic studies of metal speciation. The kinetic data were analyzed by the iterative deconvolution method. The applicability of the Chelex batch technique to metal speciation was validated by analysis of model solutions containing these metal ions with or without EDTA, NTA and fulvic acid. Use of the Chelex batch technique for Cd, Cu and Pb speciation in snow and river surface water samples revealed a number of kinetically distinguishable components of these metals (as complexes) ranging from one to three, probably present as aquo ions or inorganic complexes in the snow sample, and bound to macromolecules/and or colloidal materials in the river surface water sample.  相似文献   

4.
The capability of determining element concentrations at the trace and ultratrace level and isotope ratios is a main feature of inorganic mass spectrometry. The precise and accurate determination of isotope ratios of long-lived natural and artificial radionuclides is required, e.g. for their environmental monitoring and health control, for studying radionuclide migration, for age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, for quality assurance and determination of the burn-up of fuel material in a nuclear power plant, for reprocessing plants, nuclear material accounting and radioactive waste control. Inorganic mass spectrometry, especially inductively coupled plasma mass spectrometry (ICP-MS) as the most important inorganic mass spectrometric technique today, possesses excellent sensitivity, precision and good accuracy for isotope ratio measurements and practically no restriction with respect to the ionization potential of the element investigated—therefore, thermal ionization mass spectrometry (TIMS), which has been used as the dominant analytical technique for precise isotope ratio measurements of long-lived radionuclides for many decades, is being replaced increasingly by ICP-MS. In the last few years instrumental progress in improving figures of merit for the determination of isotope ratio measurements of long-lived radionuclides in ICP-MS has been achieved by the application of a multiple ion collector device (MC-ICP-MS) and the introduction of the collision cell interface in order to dissociate disturbing argon-based molecular ions, to reduce the kinetic energy of ions and neutralize the disturbing noble gas ions (e.g. of 129Xe+ for the determination of 129I). The review describes the state of the art and the progress of different inorganic mass spectrometric techniques such as ICP-MS, laser ablation ICP-MS vs. TIMS, glow discharge mass spectrometry, secondary ion mass spectrometry, resonance ionization mass spectrometry and accelerator mass spectrometry for the determination of long-lived radionuclides in quite different materials.  相似文献   

5.
The emission of M2X+ cluster ions in thermal ionization mass spectrometry when graphite is loaded on the heating filaments was studied. The emission model of non-reductive thermal ionization of graphite was preliminarily discussed and factors influencing the thermal emission of M2X+ ions were investigated. The results show that the intensities of M2X+ cluster ions are related to ionic radius and crystal lattice energy, and possibly also to the solvation energies of ions. The intensities of M2Cl+ (M stands for K, Rb, and Cs) cluster ions, the M2Cl+/M+ ratios, and the 37Cl/35Cl ratios determined from M2Cl+ ion measurement usually increase with measurement time. The variation of the 37Cl/35Cl ratios determined from Cs2Cl+ ion measurement is lower than those based on K2Cl+ and Rb2Cl+ ion measurement, indicating the lowest isotopic fractionation.  相似文献   

6.
Two series of small polyatomic ions, HxCO+ and HxN2(+) (x = 1, 2, 3), were systematically characterized using three correlated theoretical techniques: density functional theory using the B3LYP functional, spin-restricted second-order perturbation theory, and singles + doubles coupled cluster theory with perturbative triples. On the basis of thermodynamic data, the existence of these ions in inductively coupled plasma mass spectrometry (ICP-MS) experiments is not surprising since the ions are predicted to be considerably more stable than their corresponding dissociation products (by 30-170 kcal/mol). While each pair of isoelectronic ions exhibit very similar thermodynamic and kinetic characteristics, there are significant differences within each series. While the mechanism for dissociation of the larger ions occurs through hydrogen abstraction, the triatomic ions (HCO+ and HN2(+)) appear to dissociate by proton abstraction. These differing mechanisms help to explain large differences in the abundances of HN2(+) and HCO+ observed in ICP-MS experiments.  相似文献   

7.
本文以电热蒸发电感耦合等离子体质谱(ETV-ICP-MS)为手段,探讨了Cr、Ni、Zr、Nb和Yb在石墨炉中的蒸发/原子化机理;比较了不同化学改进剂存在条件下,Cr、Ni、Zr、Nb和Yb的蒸发行为和在石墨炉原子吸收(GFAAS)中的原子化行为;考察了石墨炉温度和ICP功率等实验参数对上述元素发射强度及轮廓的影响.结果表明,Pd和Mg化合物的存在对Cr、Ni、Zr、Nb和Yb的蒸发/原子化行为没有明显的化学改进作用;然而,以聚四氟乙烯(PTFE)为化学改进剂时,可显著改善Cr、Ni、Zr、Nb和Yb的蒸发行为,避免难熔碳化物的形成,降低待测物的蒸发温度;对Cr和Ni的GFAAS信号强度略有增强;但是,由于Yb、Nb和Zr氟化物的离解键能很高,难以离解/原子化,PTFE的存在反而降低了Yb、Nb和Zr在GFAAS中的信号强度.  相似文献   

8.
Precise and accurate isotope ratio measurements by ICP-MS   总被引:2,自引:0,他引:2  
The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.  相似文献   

9.
电感耦合等离子体质谱技术最新进展   总被引:22,自引:0,他引:22  
李冰  杨红霞 《分析试验室》2003,22(1):94-100
对1998年以来电感耦合等离子体质谱技术(ICP-MS)的最新进展作一简要回顾。内容包括同位素比值分析、双聚焦扇形磁场高分辨ICP-MS、多接收器磁扇形等离子体质谱仪(MC-ICP-MS)、飞行时间等离子体质谱仪(ICP-TOF-MS)、“冷”等离子体及屏蔽炬技术以及动态碰撞/反应池技术等进展。  相似文献   

10.
The substituent effect on the reactivity of the C-N bond of molecular ions of 4-substituted N-(2-furylmethyl)anilines toward two dissociation pathways was studied. With this aim, six of these compounds were analyzed by mass spectrometry using electron ionization with energies between 7.8 and 69.9 eV. Also, the UB3LYP/6-31G (d,p) and UHF/6-31G (d, p) levels of theory were used to calculate the critical energies (reaction enthalpies at 0 K) of the processes that lead to the complementary ions [C(5)H(5)O](+) and [M - C(5)H(5)O](+), assuming structures that result from the heterolytic and homolytic C-N bond cleavages of the molecular ions, respectively. A kinetic approach proposed in the 1960s was applied to the mass spectral data to obtain the relative rate coefficients for both dissociation channels from ratios of the peak intensities of these ions. Linear relationships were obtained between the logarithms of the relative rate coefficients and the calculated critical energies and other thermochemical properties, whose slopes showed to be conditioned by the energy provided to the compounds within the ion source. Moreover, it was found that the dissociation that leads to [C(5)H(5)O](+) is a process strongly dependent upon the electron withdrawing or donating properties of the substituent, favored by those factors that destabilize the molecular ion. On the contrary, the dissociation that leads to [M - C(5)H(5)O](+) is indifferent to the polar electronic effects of the substituent. The abundance of both products was governed by the rule of Stevenson-Audier, according to which the major ion is the one of less negative electronic affinity.  相似文献   

11.
The photo ionization of furan by an intense 25 ns Nd:YAG 532 nm laser has been studied by time-of-flight mass spectrometry. At the laser intensity of 1010~1011 W/cm2, multi-charged ions Can+ (n=2~4) and Ohm+ (m=2~3) appeared in the mass spectra when argon was used as the carrier gas. From the peak splitting and the numeric analysis, the most probable kinetic energies of C2+, C3+ and C4+ were confirmed to be 21、63 and 100 eV respectively, and the most probable kinetic energies of O2+ and O3+ were confirmed to be 20 and 40 eV respectively. It is proposed that the multi-charged ions come from the Coulomb explosion of furan cluster ions produced by multi photon ionization of neutral furan cluster.  相似文献   

12.
The interaction of C2H5X, 1-C3H7X, 1-C4H9X, where X = I, Br, Cl, with strong (1 x 10(13)-1.2 x 10(14) W/cm2) 35 ps laser pulses at 1064 nm is studied by means of time-of-flight mass spectrometry. The multielectron ionization following the C-X bond elongation has been verified for the studied molecules. By combination of the intensity dependence of the ion yields, the estimated kinetic energies of the released fragment ions, and their angular distributions, we have identified the different dissociation channels of the transient multiply charged parent ions. From the dependence on the laser intensity of the ratio of the doubly charged halogen ions to the singly charged ones, it is concluded that the molecular coupling with the laser field increases with the molecular size.  相似文献   

13.
The photoionization of methyl iodide beam seeded in argon and helium is studied by time-of-flight mass spectrometry using a 25 ns, 532 nm Nd-YAG laser with intensities in the range of 2 × 1010–2 × 1011 W/cm2. Multiply charged ions of Iq+ (q = 2–3) and C2+ with tens of eV kinetic energies have been observed when laser interacts with the middle part of the pulsed molecular beam, whose peak profiles are independent on the laser polarization directions. Strong evidences show that these ions are coming from the Coulomb explosion of multiply charged CH3I clusters, and laser induced inverse bremsstrahlung absorption of caged electrons plays a key role in the formation of multiply charged ions.  相似文献   

14.
The energetics and dynamics of collision-induced dissociation of O2- with Ar and Xe targets are studied experimentally using guided ion-beam tandem mass spectrometry. The cross sections and the collision dynamics are modeled theoretically by classical trajectory calculations. Experimental apparent threshold energies are 2.1 and 1.1 eV in excess of the thermochemical O2- bond dissociation energy for argon and xenon, respectively. Classical trajectory calculations confirm the observed threshold behavior and the dependence of cross sections on the relative kinetic energy. Representative trajectories reveal that the bond dissociation takes place on a short time scale of about 50 fs in strong direct collisions. Collision-induced dissociation is found to be remarkably restricted to the perpendicular approach of ArXe to the molecular axis of O2-, while collinear collisions do not result in dissociation. The higher collisional energy-transfer efficiency of xenon compared with argon is attributed to both mass and polarizability effects.  相似文献   

15.
《Chemical physics letters》1987,134(3):214-219
A method is described for the production of large cluster ions by direct laser vaporization in a low-pressure FTMS. Production of high-mass carbon cluster ions (Cn+; 40 <n < 180) and bismuth-antimony (BixSby+) cluster ions containing up to five metal atoms are reported. The observed distributions are compared with those obtained previously by both direct laser vaporization and molecular beam sources. Details of the mechanism for formation of these larger cluster ions by direct laser vaporization are discussed. The mass selectivity and long ion residence times obtainable in the FTMS may now be utilized in the study of these cluster ions. Results are presented from a limited study of the ion/molecule reactions and collision induced dissociation of the high-mass carbon cluster ions.  相似文献   

16.
Threshold collision-induced dissociation of M(+)(adenine) with xenon is studied using guided ion beam mass spectrometry. M(+) includes all 10 first-row transition metal ions: Sc(+), Ti(+), V(+), Cr(+), Mn(+), Fe(+), Co(+), Ni(+), Cu(+), and Zn(+). For the systems involving the late metal ions, Cr(+) through Cu(+), the primary product corresponds to endothermic loss of the intact adenine molecule, whereas for Zn(+), this process occurs but to form Zn + adenine(+). For the complexes to the early metal ions, Sc(+), Ti(+), and V(+), intact ligand loss competes with endothermic elimination of purine and of HCN to form MNH(+) and M(+)(C(4)H(4)N(4)), respectively, as the primary ionic products. For Sc(+), loss of ammonia is also a prominent process at low energies. Several minor channels corresponding to formation of M(+)(C(x)H(x)N(x)), x = 1-3, are also observed for these three systems at elevated energies. The energy-dependent collision-induced dissociation cross sections for M(+)(adenine), where M(+) = V(+) through Zn(+), are modeled to yield thresholds that are directly related to 0 and 298 K bond dissociation energies for M(+)-adenine after accounting for the effects of multiple ion-molecule collisions, kinetic and internal energy distributions of the reactants, and dissociation lifetimes. The measured bond energies are compared to those previously studied for simple nitrogen donor ligands, NH(3) and pyrimidine, and to results for alkali metal cations bound to adenine. Trends in these results and theoretical calculations on Cu(+)(adenine) suggest distinct differences in the binding site propensities of adenine to the alkali vs transition metal ions, a consequence of s-dsigma hybridization on the latter.  相似文献   

17.
To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP-MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar+ and the molecular ions of argon ArX+ (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP-MS ("Platform ICP", Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio 80Se/ 40Ar2+ was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios 44Ca/ 40Ca and 56Fe/57Fe in 10 microg L(-1) solution nebulized by means of a USN and for 78Se/80Se in 100 microg L(-1) solution nebulized by means of a Meinhard nebulizer.  相似文献   

18.
Matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) and electrospray ionization mass spectrometry (ESI-MS) are used to evaluate the alkali metal ion binding selectivities of a series of calixarenes. Each calixarene of interest is mixed with one or more alkali metal salts (1:100 ratio of calixarene to metal), either in the ESI solution or on the MALDI probe surface, and the relative binding selectivities are directly determined from the intensities of the calixarene/metal complexes in the mass spectra. For t-butylcalix[4]arene-tetraacetic acid tetraethyl ester (calixarene 1), complexation of Na+ is favored over complexation of K+, in agreement with prior solution results obtained by conventional methods. For the three calixarenes that do not have t-butyl groups on the upper rims, the calixarenes preferentially bind K+ over Na+, thus demonstrating that size selective complexation can be probed with both the ESI and MALDI methods. Collision-activated dissociation results indicate that the phenyl oxygens, but not necessarily the ethoxy ethyl oxygens of the lower rims, are the primary binding sites for the alkali metal ions.  相似文献   

19.
Detection efficiencies of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), defined as the ratio of ions reaching the detector and atoms released by LA were measured. For this purpose, LA of silicate glasses, zircon, and pure silicon was performed using nanosecond (ns) as well as femtosecond (fs) LA. For instance, ns-LA of silicate glass using helium as in-cell carrier gas resulted in detection efficiencies between approximately 1E-7 for low and 3E-5 for high mass range elements which were, in addition, almost independent on the laser wavelength and pulse duration chosen. In contrast, the application of argon as carrier gas was found to suppress the detection efficiencies systematically by a factor of up to 5 mainly due to a less efficient aerosol-to-ion conversion and ion transmission inside the ICP-MS.  相似文献   

20.
The application of mass spectrometric methods in the determination of isotopic abundance and of trace elements in highly enriched187Os is described. The capability of ICP-MS in comparison with solid-state mass spectrometric techniques (SIMS, SNMS and GDMS) for the precise isotopic analysis of highly-enriched osmium has been investigated. The formation of cluster ions in several plasma types has been measured, and the problems of possible interferences from molecular and cluster ions is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号